Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIO NS OF PERMIT BLRE -07 -22-7 698 Surprise Valley 1, LLC New Single-Family Dwelling w/ Attached Garage TBD CR 237, S¡It Sec.24, T.05, R.92 - 212724400382 1) ALL WORK SHALL COMply W|TH THE 2015 INTERNATIONAL RESIDENTIAL CODE (t.R.c.)AND 2009 TNTERNATTONAL ENERGY CONSERVATION CODE (l.E,C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL PERMtTTtNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTI FICATE OF OCCUPANCY. 4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT, 5) OPEN HOLE SOTLS REPORT tS REOUTRED ATTIME OF FIRST FOOTING INSPECTION. HAVE REPORT READY FOR THE BUILDING INSPECTOR. SOIL BEARING AND COMPACTION AS SPECIFIED BY GEOTECHNICAL ENGINEER, ó) ON-SITE WASTEWATER TREATMENT SYSTEM (OWTS)TO BE INSPECTED BY A PROFESSIONAL ENGINEER LICENSED IN THE STATE OF COLORADO. PROVIDE ENGINEER'S FINAL REPORT PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY. 7) OFFTCE #109 tS NOT APPROVED FOR FUTURE USE AS A SLEEPING BEDROOM, CONTAINS NO EMERGENCY ESCAPE & RESCUE OPENING. SUBJECT OFFICE #109 SHALL BE MECHANICALLY VENTILATED PER 2015 IRC SECTION R303,