HomeMy WebLinkAboutPermit Card
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 000 Mustang Mesa Tr Rifle, CO _ Parcel No.: _217721401003
Owner Name: Tara and Dennis Booth Owner Phone: (603) 630-0467
Designed By: High Country Engineering Designer Phone: (970) 945-8676
Number of Bedrooms: _3_ Minimum Tank Capacity: 1,000-gallon Minimum Absorption: 525 ft 2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-7619_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _09/26/2022____________________ Expiration Date_09/26/2023_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by High Country Engineering dated June 15, 2022. Changes to the design and permit must
be approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new three-bedroom residence. The system will consist of a new, two-
compartment 1,000-gallon septic tank set level with access to grade. Effluent will gravity flow to an
distribution box that will distribute effluent to 525 ft2 of STA. The new STA will consist of three
gravelless chamber trenches, each trench consisting of 13 chambers per trench (39 chambers total).
Inspection ports are to be installed at each end of each trench. Maintain all setbacks and elevations
as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
09/25/2022
Issued By: Garfield County Environmental Health
Department
Date