HomeMy WebLinkAboutConditions of Permitco NDITIONS OF PERMIT
BLRE-09-22-7795
RAYMUNDO BENCOMO
NEW 1,200 SO FT PRE ENGINEERED STEEL STORAGE BUILDING, "COLD
STORAGE, PRIVATE USE ACCESSORY TO THE RESIDENCE".
31 ó33 HWY 6 & 24, SILT CO
217905400592
1) ALL WORK SHALL COMPTY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)
AND 2009 TNTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C.)
2) pROPOSED IMPROVEMENTS ARE SUBJECT TO ALLAPPLICABLE ITEMS CONTAINED lN THE
ATTACH ED "GARFI ELD COU NTY BU I LDING REOU I REM ENTS". NU M BER REFERENCES
NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) NO PLUMBING, MECHANICAL OR ELECTRICAL WORK IS REPRESENTED BY THE OWNER
UNDER THIS CURRENT BUILDING PERMIT.
4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL
FIRE DISTRICÏ.
5) STRUCTURE tS APPROVED AS A DETACHED RESIDENTIAL ACCESSORY BUILDING, TYPE ll-8,
coNSTRUCTION (NON-SPRIN KLERED) OCCU PANCY G ROU P'U" UTI LITY.
ó) ALL HtcH-STRENGTH BOLTTNG AND FrELD WELDTNG REOUIRES SPECIAL INSPECTOR AS
PER I.B.C. CHAPTER 17. PROVIDE COPY OF APPROVAL REPORT AT FINAL BUILDING
INSPECTION & CERTIFICATE OF OCCUPANCY.
7l A WALK-THROUGH S|DE-HTNGED DOOR (MlN, SIZE 3ó |NCH WIDE BY 80 INCH HIGH) lS
REOUIRED FOR EGRESS FROM THE BULDING INTERIOR
8) OPEN HOLE SOILS REPORT REOUIRED AT FOOTING INSPECTION, 1,500 PSF
9) THE BUtLDtNG pERMtT tS TSSUED FOR AN UNHEATED BUILDING SHELL ONLY. SUBSEOUENT
CONSTRUCTION AT BUILDING INTERIOR _ INCLUDING INSULATION, HEATING SYSTEM,
INTERIOR FINISH OR PARTITION WALLS - REOUIRES THAT THE PROPERTY OWNER SUBMIT
AMENDED PLANS TO BHE BUILDING DEPT. FOR REVIEW & APPROVAL.
10) tF BUtLDtNc tS TO BE HEATED - NOW OR rN THE FUTURE - INSULATION AÏ THERMAL
ENVELOPE SHALL COMPLYWITH 2OO9 I.E.C.C. TABLE 4A2.2.5INCLUDING RIGID
INSULATION AT CONCRETE SLAB EDGE AND FOUNDATION PERIMETER PER I.E.C.C.
SECTION 4A2.2.8. FOR MECHANICAL& HEATING SYSTEM REOUIREMENTS REFERENCE
trEMS #58, 59, 62, 63, ó4 ó5 AND 71.
11) TH|S BUILDtNc tS APPROVED FOR USE AS NON-HABITABLE UNHEATED GARAGE /
STORAGE ONLY (ACCESSORY TO THE MAIN RESIDENCE). ANY FUTURE CHANGE(S) IN
BUILDING OCCUPANCY OR USE SHALL FIRST REOUIRE SUBMISSION OF A NEW BUILDING
APPLICATION AND A COMPLETE REVIEW FOR BUILDING & LAND USE CODES IN EFFECT AÏ
TIME OF FUTURE WORK.