Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIO NS OF PERMIT BLRE-09 -22-7813 Schettler Family Joint Rev. Trust New Single-Family Dwelling w/ attached garage 47 Yalley View Pl., Parachute Battlement Creek V¡llage, Sec. 2, Block 3, Lot ó 1) ALL WORK SHALL COMply W|TH THE 2015 INTERNATIONAL RESIDENTIAL CODE (r.R.c,)AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l.E,C.C,) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS", NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL PERMtTTtNG AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH.IN APPROVAL IS REOUIRED AT FRAME INSPECTION, ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT, 5) OPEN-HOLE SOTLS REPORT REOUTRED AT FOOTING INSPECTION TO VERIFy 1.2O0 PsF SOII BEARING CAPACITY. PROVIDE COPY OF ENGINEER'S REPORT FOR BUILDING INSPECTOR REVIEW AT FOOTING INSPECTION. ó) PREFABRICATED ROOF TRUSSES. HAVE ENGINEERING FOR INSPECTOR ATTIME OF FRAME INSPECTION. 40 PSF TCLL 7) A LOT IMPROVEMENT CERTIFICATE, SEALED BY A COLORADO LICENSED SURVEYOR, IS REOUIRED AT FOUDATION INSPECTION TO VERIFY STRUCTURE - INCLUDING ROOF OVERHANGS, DECKS AND OTHER PROJECTIONS - IS IN COMPLIANCE WITH MINIMUM SETBACKS AND/OR BUILDING ENVELOPE REOUIREMENTS. s) tT SHALL BE AT GARFTELD COUNTY BUILDING INSPECTOR',S DISCRETION TO REOUIRE FURTHER ENGINEERED WET STAMPED DETAILS ATTIME OF FRAMING INSPECTION.