Loading...
HomeMy WebLinkAboutFireplace SpecsWARNOCK HERSEY LISTING LABEL FIREROCK LISTED MASONRY FIREPLACE SYSTEM MODEL FIREROCK coNVENTToNAL f]go nse Zqz n+s tNcH MoDULAR FtREpLAcE cALrF coNV n go n ge flqz ! ¿s tNcH MoDULAR FtREpLAcE CERTIFIED TO UL 127 WHI. B U I L D I N G M AT E R IA L S US 1" 1" 16" 12" 1" 29" CLEARANCE TO COMBUSTIBLES UNIT TO SIDE ENCLOSURE UNIT TO FACE ENCLOSURE OPENING TOP TO COMBUSTIBLE MANTLE OPENING TO COMBUSTIBLE FACEWALL UNIT TO BACK ENCLOSURE UNIT TO CEILING JOISTS OPENING TO SIDEWALLlntertek wN 13350 HEARTH EXTENSION BEYOND FRONT: 20" HEARTH EXTENSION BEYOND SIDES: 8" INSULATION FROM FIREBOX: 3" SEE FIRE ROCK'S INSTALLATION AND OPERATING INSTRUCTIONS FOR THIS MODEL REFER TO THE INTERTEK DIRECTORY OF BUILDING PRODUCTS (HTTPS://BPDI RECTORY.INTERTEK.COM) FOR DETAI LED lN FORMATION. ***wARNINGS**r a a a a a USE SOLID WOOD, PROCESSED SOLID FUEL FIRE LOGS, NATURAL GAS, PROPANE, OR COAL FUEL ONLY DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS NOT SPECIFIED FOR USE WITH THIS PRODUCT THIS FIREPLACE HAS NOT BEEN TESTED WITH GLASS DOORS TO REDUCE RISK OF FIRE OR INJURY DO NOT INSTALL GLASS DOORS WHEN BURNING GAS IN THE FIREPLACE, ADJUST DAMPER TO FULLY OPEN POSITION ONLY VENTED GAS LOG SETS WHICH ARE LISTED ARE TO BE INSTALLED IN THIS FIREPLACE. DO NOT OPERATE AN UNVENTED GAS LOG SET IN THIS FIREPLACE. MANUFACTURED BY: FIRE ROCK PRODUCTS, LLC; 3620 AVENUE G; BIRMINGHAM, AL 35064 ÌËn 10 FIREPLACE DIMENSIONS -G- E J DIMENSION 30"36"42"48" A OVERALLWIDTH 38"44"50"56 OVERÂLL DEPTH 28.5"28.5"28.5"28.5" c FIREBOXHEIGHT 37.5"37.5"5 /.J D SMOKE CHAMBER HEIGHT zz.5 / )31.5"3t.5"40.75" E OPENING WIDTH*32.5"38.5"44.5"50.5" F OPENINGHEIGHT*33.75"J3./)55./)35./J G WIDTH AT CHIMNEY BA.SE LO zo 32 32" H FIREBOXDEPTH 22.5"22.5"zz.)22.5" J WIDTHATREAR 22 28"40" I C *b efore firebrick lining FIGURE 1.1 FIGURE 1.4FIGURE 1.3 42" CONVENTIONAL J, FIGURE 1.2 36" CONVENTIONAL i1 48" CONVENTIONAL CLEARANCE TO COMBUSTIBLES Opening to Side wall Opening to Combustible T?im Opening to Combustible Mantle with 8" Depth Noncombustible Hearth Extension 2O" front,8" each side Firebox and Smoke Chamber to Combustibles or Framing 28" I2' r6" MANTLE TILE/MARBLE 1," HEARTH EXTENSION FIGURE 2.1 ¿J Iqôø 2f¡"12" -{,!3 Smoke Chamber to Front Wall and Smoke Chamber Top to Wood Framing l" ¡¡rilFFllllltã Failure to maintain stated minimum clearance to combustibles may result in a fire or explosion, causing property damage, personal iryury or loss of life. NOTE: "Combustibles" are defined as "normal construction materials" and are considered to be: wood framing materials, par-ticle board, millboard, plywood sub-flooring, p\wood paneling, wood flooring, and drywall. The fireplace must sit on a concrete pad or slab that is designed to bear the total weight of the fìreplace and chimney. This pad or slab should provide for the noncombustible hearth extension substrate needed to suppoft the code required noncombustible hearth extension finish materials. This fireplace can be installed on a combustible surface only when using the LiteRock installation method (refer to pages 28-30). All fireplaces should have a noncombustible hearth that extends 20" beyondthe front of the fìrebox and B" to either side. Approved noncombustible materials include brick, tile, or stone that is properþ supported, with no combustible material against the underside. t¡rrrnïNlNtt Do not pack required air spaces with insulation or other materials.lJsing insulation or other materials in required air spaces may result in a fire or explosion, causing property damage, personal injury, or loss of life. L1" 12 FIGURE 2.2 MONTIGO/ r, I t:. I i .:: I ;{ìî rdl ¡? EII tÒ Standard t COOL-Pack glass system a rl ¡ Ò ì Multi-color LED lightingIataìlntake dampers rot :1,.:' Choice of glass media Single Sidecj See through Options :l t- a : -: o(, F o E Speckled stones driftwood t L ENSIONS lndoor-Outdoor seal kit for see through units I cgrcxûM Black reflective glasst ,, Flue gas dampers ¡1¡n1 ¡ r iirrtrì.Ui!t fLl/\;ri l,;! [ .ii^iì4 J,\,I Ii'/'fl.;\ll Ftìq,',4 Ut\l I :jìli;,¡ I i! ltrf l:AØVq 42V¡52%. 54Vt 641h 661./4 76Vq 78th 88V4 9ø1,h 10Øth 1Ø2|t¡ I i,r:ii I 23t/4 263Áø 23V¿ 263/ta 23Y4 263/tø 23Ya 263hø 231/d 263hs 23V¿ 26JAa 3!, I)¡ I'l ti 19Ta 19Yq 191/a 19V4 19'1/s 19Vq 19'1/s 19Vq '19'1/s 19%197/8 19Yq iltri llr "l9tt'u I U I'ro 19r! lU/u1u lg)t lUl'¡o 19tt'¿ "ltll\ø 19û'¿ l ul'r¡19t'B lU/r1o r/1l.rl,rn¡(l 36xH 48 x l'l 6øxH 84xþl ' Standard ¡n PC420 PC520 PC620 PC820 ù Plus glass heightUn¡t d¡mens¡ons do not include mounting flanges BTI,J L ISTIi..JG PC**3**N* 40¡000 Pc--4--N- 50,000 PC*'5."N^ 75,000 PC**6**N* 88,000 PC**7**N* 1 00,000 PC.^8.-N^ r r 2,000 72xH PC**3**L* 31,000 PC--4-.L- 52,000 PC^^5^-L* 64,000 96XH PC**6**L* 78,000 105,000 Pc¡^81^Ll ,l 20,000 Unit Specifications ooÉ, Co u ts c.F co oIo c acG o ô- '=ú: =Fó ı(, ñ oz ft-6 Øc Fñ ;c(, oJñ C co'Þñ _9 o:E 14o (_.,) ofr o oc co gorov!u,iÆs '.OoÉ ^CVo c.!lcç ! ó o cô o.:fgo 1Ø', 1ø" 1Ø" 1Ø" 12', co E a).: o CJ ã .9 utr 2Ø8-24Ø VAC Single Phase 15 Amp 2Ø8-24Ø VAC Single Phase 15 Amp 2Ø8-24øVACSingle Phase 15 Amp 2Ø8-24Ø VAC Single Phase 15 Amp 2Ø8-24Ø VAC Single Phase 15 Amp 2Ø8-24Ø VAC Single Phase 15 Amp PCSBFPV-Rø3-ø8 PCSBFPV-RØ3.']Ø PCSBFPV-Rø3-1ø PCSBFPV-Rø3-1ø PCSBFPV-RØ3-1ø PCSBFPV.RØ3-']2 PCB BU RNER STYLE tr irllt I¡v', Irir:,lr i¡:n, lrìr:1ii !orn' I rÍ,:t ir ir.,r r ìlr blr ri PCSBFPV-Wø3-ø8 PCSBFPV-Wø3-1ø PCSBFPV-WØ3-1ø PCSBFPV-WØ3-1ø PCSBFPV-Wø3-1ø PCSBFPV-WØ3-12 o .-c ; o o 3 À PCINGPV-Lø3-ø8 PCINGPV-LØ3-'Iø PCINGPV-Lø3-iø PCINGPV-LØ3.1 Ø PCINGPV-Lø3-1ø PCINGPV-LØ3-12 56.52 sq.inches 1ØØ.48 sq.inches 1øø.48 sq.inches 'iØØ.48 sq.inches 1ØØ.48 sq.inches 157 sq. inches oJñ .= 'ı ao ooo ı o oF ìı =ccl CJì è PC+*3x*** 4Ø,ØØø 31,ØØØ 2x6" PC*x4**** 5ø,ØØØ 52,ØØØ 2x8" Pcxxsx*x* 75,ØØØ 64,ØØø 2x8" PC*+6**** 88,ØØØ 78,øøØ 2x8" PC**7*x*x 1øø,øøø 1Ø5,ØØØ 2x8" PC*+8x+** 112,øØØ 12Ø,Øøø 2 x 1Ø" Matte black Top Top both sides see chart Natural gas of propane oo ı co o! oo Eoô As low as 11s'F (46'C) On/Offwall switch, multifunction LED remote R¡BBON BURNER HIGH.LOW BURNER 5ø' 5Ø'x2 PRODIGY QUICKSHIP The following units are stocked and feature premium Glacìer fìrestones and pre-installed black reflect¡ve glass panels. Natural gas only. PC42O PC52O PC62O PC82O PC3 BU R NER STYLE tibl-,or¡ iilrLron riblrcrrr t i1:,irLrn r il-¡lrtrn PC4 BURNER STYLE iriglt lcvr l;ic1h lort lìiçllì lLrvf lriqlt loti' ril:¡lroit PC5 BU RN ER STYLE llì¡rii lr¡n¡ liirll-i Ìot,, hicllt iot,,, l¡ioli t¡r¡ r ii: fr¡;r: PC6 BU RNE R STYLE irigih lcrr iriolr Ic.*' hiqlr lcrlt hic;h li:,vr riiil¡ln PC7 BURNER STYLE lrii;lr {ov" irìqh ion, hiçli I'rvr, iriclir lt.ir r ii:,l.¡r:r r 6Ø" 36" 3ø" 2ø" 12" U tn rnensrons FLANGE DIMENSIONS l " mourìting flanges are removable and vary in location based on the unit configuratìon. Flanges on the Single sided a¡rd See through units are set back 5/8". Additionally the flange on the top of all Prodigy configurations is set back 5/8 . PRODIGY SINGLE SIDED DIMENSIONS PRODIGY CORNER DIMENSIONS PRODIGY SEE THROUGH DIMENSIONS AA T cI T cI HI it1 G G HIIi lEF-¡ - T JI T JI I HI IJI 12, 2ø, 3ø, $Ys 151/g 36, 6ø MM B EFGH PRODIGY BAY DIMENSIONS J 231/c+ Glass He¡9ht 26t/ta1' G lass Height *13t/s-H * 133/e- 8 7 6 5 4 3 AIR INTAKE 2X1ø 2X8 2X8 2X8 2X8 2X6 EXHAUST 12" 1ø" 1ø" 1ø', 1ø" BC 6ø 56 48 4ø 32 24 D 951h 83Y2 71th 591h 471/2 35Y2 M 1ø3rh 91?/s 79r/8 677/s 55?h 437h T E L T E K A 1øølh 88Y4 76Y4 64th 5ZVa 4ølh 185/¿19r/8 K 1ø3Y2 91V2 79Y2 67lh 551h 431h L 993/q 873/¿ 753/c 633/c 513/¿ 393/¿ Unit Framing Rough-in l l l I PRODIGY SINGLE SIDED FRAMING ROUGH IN 42Y4 A', 5' 6' 7' I' 54Y4 66Y4 78Vc 9Øt/c 1Ø2Yc 26¡16+ Glass Height PRODIGY CORNER FRAMING ROUGH IN 7' PRODIGY SEE THROUGH FRAMING ROUGH IN O 42Y4 4' 5' 6' 7', I' 54Y4 66Vc 7AY4 9øU4 1ø2Y4 263lro+ Glass Height "O" dimension allows the unit to be pushed into place with the mount¡ng flanges still installed. Once the un¡t is in place, add studs beh¡nd the mounting flanges to properly secure. PRODIGY BAY FRAMING ROUGH IN 4', 5' 6' 7', I' 54eÁa 66eÁa 78eÁø 9Øe/ta 1Ø2e/tø 263lro+ Glass Height o 3',3' o I o 3Õ6'5'4',3' o I 43Y4 55V4 671/4 79V4 91Vc 1ø3%o I263lro+ Glass Height 42eAa