Loading...
HomeMy WebLinkAboutObservation of Excavation 11.11.2022l(+-rt Kumar & Associates, lnc.''o Geotechnical and Materiãls Ertgineers 5020 County Road 154 and [nvironrnenlal Scientìsls Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email : kaglenwood@kumarusa.com &.nämplc,YøêQwnødÇçwrpanywvwv.kumarusa.com Office Locations: Denver (HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado November 11,2022 Frank Fraser 0719Road225 Rifle, Colorado 81650 fiasergaragef@,srn ai1 . c onl Project No.22-7-713 Subject.Observation olExcavation, Proposed Garage Building, 07 l9 Road 22-5 (Antlers Lane), Garfield County, Colorado Mr. Fraser As requested, a representative of Kumar & Associates obserued the excavation at the subject site onNovemberT.2022toevaluatethesoilsexposedforfoundationsupport. Thefindingsofour obseryations and recommendations for the foundation supporl are presented in this report. The services were performed in accordance with our agreement for professional engineering services to you dated November 3, 2022 The proposeci steel builcling will be 40'x4O' in plan size and supported on a monolithic structural slab foundation with turn-down edges insulated against frost penetration. An allowable soil bearing pressure of I,500 psf is designated lor the foundation support. At the time of our visit to the site, the building excavation had been cut in one level with the perimeter turn-down edge depth of one-foot. The soils exposed in the bottom of the excavation consisted of very sancly silty clay. Results of swell-consolidation testing perfbrmed on a sample taken from the site, shown on Figure 1, indicate the soils are slightly to moderately compressible under conditions of loading and wetting. No free water was encountered in the excavation and the soils were moist. Considering the conclitions exposed in the excavation and the nature of the proposecl construction, spread fbotings/structural slab placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 1,500 psf should be adequate for support of the proposed building. The exposecl soils tend to compress when wetted under load and there could be some Frank F-raser November 11,2A22 Page 2 post-construction settletnent. The bearing soils should be protected against Íiost and concrete should not be placed on frozen soils. Exterior footings should be provided with aclequate frost protection' continuous fbundation walls/tum-down edges should be adequately reinforced to span local anomalies both longitudinally and transverse into the structural slab. A perirneter foundation drain should not be provided fbr the slab-at-grade design. Structural fill placed within slab and pavement areas can consist of the on-site soils or imported road base cornpacted to at least 95% of standard Proctor density at å moisture content near optimum. Landscape that requires regular heavy in.igation, such as sod, an<l 10 feet of the fbundation. sprinkler heads should not be located within The recommendations submitted in this letter are based on our obseruation of the soils exposed within the foundation excavation anci do not include subsurfüce exploration to evaluate the sttbsurface conditions within the loaded depth of foundation influence. This study is based on the assumption that soils beneath the footings have equal or better support than those exposed. The dsk of foundation movement may be greater than indicated in tl-ris report because of possible variations in the subsurface conditions. In order to reveal the nature and extent of variations in the subsurface conditions below the excavation, drilling wourd be required. It is possible the data obtained by subsurface exploration could change the recommendations contained in this letter' our services do uot include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future, if the client is conce*ed about MOBC, then a professional in this special field of practice should be consulted. If you have any questions or need further assistance, please call our office Sincerely, Kunr¿¡r & Associateso I;'-.1 ; Steven L. Pawlak, sLP/ljf Attachment: Figure 1 * sweil-consoridation Test Resurts (Í,15222 Kumar & Aseociatcs, lnc. a Project No. Z2-T-713 ç ç. ::. ,: SAMPLE OF: Very Sondy Silty Cloy FROM: Bottom of Excovoiion, Eosi Side WC = 15,5 %, DD = 10J pcf -200 = 54 % ¡n thê NO MOVEMENT UPON WETTING bs JJ l¿J =UI I zo È Õ:o(/)z()() 0 -1 -2 _z -4 1.0 APP - KSF t0 t00 22-7 -7 13 Kumar & Associates SWELL-CONSOLIDATION TEST RESULTS Fig. 1