HomeMy WebLinkAboutConditions of PermitCONDITION OF PERMIT
BLRE-1 1 ,22-7900
R&MDevLLC
Single-Family Dwelling w/ attached g.rage
38 Puma, Carbondale
Aspen Glen, Flg 1, Lot E-7
1 ) ALL WORK SHALL COMply WITH THE 2015 TNTERNATTONAL RESTDENTTAL CODE (l.R.C.)
AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C.)
2) PROPOSED TMpROVEMENTS ARE SUBJECT TO ALL APPHCABLE ITEMS CONTAINED lN THE
ATTACH ED "GARFI ELD COU NTY BUI LDING REOUI REMENTS". NU M BER REFERENCES
NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LISÏ.
3) ELECTRTCAL PERMtTTtNG AND TNSPECTTONS BY COLORADO sïAïE ELECTRIC BOARD.
ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL
FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) WILDFIRE MlTlcATloN REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL
FIRE DISÏRICT.
5) PRE-MANUFACTURED ROOF TRUSSES. HAVE ENGTNEERING FOR INSPECTOR AT TIME OF
FRAME INSPECÏION.
ó) opEN HOLE SOTLS REPORT tS REOUTRED AT FOOTING INSPECTION AND PRIOR TO
CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT ÏO THE
BUILDING INSPECTOR. KUMAR & ASSOCIATES PRELIMINARY REPORT 22.7-199 SHOWS
BEARING CAPACITYAT 1,500 / 3,OOO PSF AND STRUCTURAL ENGINEERS DESIGN CRITERIA
REFERENCES SAID REPORT 22-7-199.
7) A LOT TMPROVEMENT CERT|F|CATE, SEALED BY A COLORADO LICENSED SURVEYOR, lS
REOUIRED AT FOUNDATION INSPECTION TO VERIFY SI'RUCTURE - INCLUDING PROPOSED
ROOF OVERHANGS, DECKS AND OTHER PROJECTIONS - IS IN COMPLIANCE WIÏH
MINIMUM SETBACKS AND/OR BUILDING ENVELOPE REOUIREMENTS.
B) AN ELEVATTON SURVEY, SEALED BYA COLORADO PROFESSIONAL LICENSED SURVEYOR,
IS REOUIRED AT FRAME INSPECTION TO VERIFY THAT AS.BUILT ROOFS COMPLY WITH ÏHE
2s-FOOT BUILDING HEIGHT LIMIT AS DEFINED IN THE LAND USE DEVELOPMENT CODE
AND/OR ASPEN GLEN PUD GUIDE,