HomeMy WebLinkAboutPermit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945‐6614 ext. 8150
For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 3554 County Road 214, Silt, CO 81652
Parcel No.: 217901300297
Owner Name: Dana Yerian and Joan Drake Owner Phone: (970) 379‐0319
Designed By: CBO, Inc. Designer Phone: (970) 309‐5259
Contractor: Daybreak Construction, Inc. Contractor Phone: (970) 379‐0319
Number of Bedrooms _3__Minimum Tank Capacity _1,000‐gal__Minimum Absorption_630 SF
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT‐7916________________________
Permit Type X New X Repair X Remodel/addition X Tank only X Field Only X Amendment
Issue Date 11/30/2022 Expiration Date 11/30/2023
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the design as submitted by CBO,
Inc. dated November 5, 2022. Changes must be approved by Garfield County Public Health and the
designer prior to construction.
The new OWTS will serve a new 2‐bedroom residence and a 1‐bedroom ADU. The system will consist
of a new, two‐compartment minimum 1,000‐gallon septic tank set level with access to grade and an
effluent filter in the outlet tee of the tank. Effluent will gravity flow to a level manifold to distribute
effluent to 672 ft2 or 660 ft2 of STA. The new STA will consist of a four‐row gravelless chamber bed
consisting of 14 Quick4 chambers per row (56 total) or 11 ARC 36 chambers per row (44 total).
Inspection ports are to be installed at each corner of the bed. Maintain all setbacks and elevations as
designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as‐built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
11/30/2022
Issued By: Garfield County Environmental Health
Department
Date