1-1/4"0 SCHBO PVC /
TRANSPORT LINE
CDPHE APPROVED 2,500-GALLON , se
SLEEVE SEWER LINE 20 LF TO --,EACH SIDE OF WATER SERVICE
CROSSING IN 61 SDR35 PVC
y
v
v
PRECAST CONCRETE THREE (3) ss s !
CHAMBER SEPTIC TANK WITH LOW
PRESSURE DOSING SYSTEM (SEE DETAIL)-
0
410 SCH.40 PVC
@2%MIN. 0 I
, d�...aq
V �
� A I 2-WAY CLEANOUT
r,
f
II
AT THE BUILDING
-
"� L- ---
SITE EVALUATION
SOIL EVALUATION
1.
SITE AND SOIL EVALUATIONS WERE PERFORMED BY:
1. THE NATIVE SOILS WERE
DERICJ. WALTER, PE DANIEL E HARDIN, PE
CLASSIFIED AS TYPE 2A SANDY
BOUNDARIES UNLIMITED INC. HPKUMARGEOTECHNICALENG.
LOAM (1% GRAVEL, 49% SAND,
923 COOPER AVE., STE. 201 5020 C.R. # 154
40% SILT & 10% CLAY) WITH AN
GLENWOOD SPRINGS, CO 81601 GLENWOOD SPRINGS, CO 81601
LTAR OF 0.50 GPD/SF.
970.945.5252 970.945.7988
2. THE NATIVE SOILS CONTAIN
2.
EVALUATION DATE(S): NOVEMBER 2018.
BOULDERS. WHEN ENCOUNTERED,
REMOVED THE BOULDER AND
3.
SETBACK REQUIREMENTS FOR A TREATMENT LEVEL 1 STA TRENCH/BED, UNLINED
BACKFILL THE VOID WITH LOAMY
SAND FILTER OR SEEPAGE PIT (PER TABLE 7-1) AND AN ADWF=600 GPD:
SAND OR SANDY GRAVELS.
3.A.
SPRING OR WELL=100'
3.B.
POTABLE WATER SUPPLY LINE=25'
S.C.
POTABLE WATER SUPPLY CISTERN=25'
3.D.
DWELLING-20'
�12'
3.E.
PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH =10'
SURFACE
3.F..
INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=25'
TOPSOIL
3.G.
LAKE, WATER COURSE; IRRIGATION DITCH, STREAM OR WETLAND =50'
3.H.
DRY GULCH, CUT BANK OR FILL AREA=25'
3.1.
SEPTIC TANK=S'
31
RESTRICTIVE LAYER OR GROUNDWATER (VERTICAL): 4' (TREATMENT LEVEL 1,
GRAVITY FEED)
LOAM 90ILS
3.
SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 7-1):
CLAYEY, VERY-'
3.A.
SPRING OR WELL=50'
SILTY SAND)
3.B.
POTABLE WATER SUPPLYLINE=10'
3.C.
POTABLE WATER SU PPLY CISTERN = 25'
3.D.
DWELLING=T
3.E.
PROPERTY LINE, PIPE OR LINED IRRIGATION DII10'
3.F.
INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE =10'
3.G.
LAKE WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50'
Site & Soils Evaluation
3.H.
DRY GULCH, CUT BANK OR FILL AREA=10'
3.1.
STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PII5'
Scale: N.T.S.
ATTACH REMOVABLE CAP OR
THREADED CLEANOUT ASSEMBLY.
INSTALL MARKER IF CAP IS TO FINISH GRADE
BE BURIED.
4"0 PVC 4"0 PVC RISER
TWO-WAY
CLEANOUT TEE
n
4"0 SEWER LINE
0 Cleanout
Scale: N.T.S.
v j
FL VALVE,
FLU AL E, TYP. I
25' MIN
INSPECTION
�0 f
v p , PORT, TYP. v�
J
6' MIN I
xo
Y v �
i 1 J
r
,P'
1-1/4°0 SCH.80 PVC
a') 3 ZONE DISTRIBUTION LINES
i' DISTRIBUTION
VALVE /
G
,
i
I� r�
! I I
I 3
\
9 }
IT
If
GENERAL ABSORPTION AREA NOTES
1. INSTALL CHAMBER UNITS IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
2. ABSORPTION TRENCHES SHALL BE 3' WIDE OR LESS
AND PARALLEL THE GROUND SURFACE CONTOURS.
PARALLELING TRENCHES SHALL BE SEPARATED BY
A DISTANCE OF U MIN.
3. THE BOTTOM OF THE ABSORPTION TRENCHES
SHALL BE LEVEL AND THE BOTTOM AND
SIDEWALLS MUST BE RAKED TO REMOVE ANY SOIL
SMEARS INCURRED DURING THE EXCAVATION.
FAILURE TO DO SO MAY REQUIRE THE CONTRACTOR
TO REPLACE THE ABSORPTION FIELD AT HIS/HER
OWN EXPENSE.
4. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE
AND AROUND THE FIELD, AS NECESSARY, TO
PREVENT SURFACE RUNOFF FROM ENTERING
ABSORPTION AREA.
5. NO EXCAVATION OF THE ABSORPTION FIELD IS TO
BE DONE DURING WET WEATHER AND USE OF
RUBBER TIRE VEHICLES OVER THE ABSORPTION
AREA IS STRICTLY PROHIBITED.
6. UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD
SHALL BE EXCAVATED AND BACKFILL SHALL
CONSIST OF IMPORTED LOAMY SAND OR SANDY
GRAVEL. THE ENGINEER SHALL BE CONTACTED IF
BEDROCK OR GROUNDWATER IS ENCOUNTERED IN
THE OVER -EXCAVATION.
7. TOPSOIL COVER MAY BE VARIED (1-FOOT MINIMUM,
2-FOOT MAXIMUM) TO ALLOW FOR LANDSCAPING.
MAINTENANCE NOTES
1. TO ENCOURAGE THE HEALTH AND LONGEVITY OF THE DINTS SYSTEM, THE OWNER SHALL CONSIDER THE FOLLOWING:
1.A. MINIMIZE THE AMOUNT OF WATER THAT GOES DOWN THE DRAIN, THE BETTER YOUR SYSTEM WILL WORK.
1.B. MINIMIZE SOLIDS GOING DOWN THE BRAIN.
1.C. ELIMINATE GARBAGE DISPOSALS OR KEEP THE USE OF GARBAGE DISPOSALS TO A MINIMUM.
1.D. MINIMIZE GREASE AND OILS THAT GO DOWN THE DRAIN.
I.E. USE LINT FILTERS ON LAUNDRY MACHINE DRAINS.
1.F. KEEP SAND AND DIRT OUT OF THE BUILDING DRAIN.
1.G. AVOID FLUSHING SANITARY NAPKINS OR PAPER PRODUCTS OTHER THAN TOILET PAPER.
1.H. DO NOT USE LYE -BASED DRAIN UNCLOGGER CHEMICALS SUCH AS DRAINO, OVEN -OFF, OR OTHER STRONG
CLEANING AGENTS.
1.1. DO NOT PUT ANY "ROOT DETERRENTS" DOWN THE DRAIN.
1.J. DO NOT POUR PAINT THINNER, PESTICIDES, PAINTS OR PHOTO LAB CHEMICALS DOWN THE DRAIN
I.K. MINIMIZE USE OF CHLORINE BLEACH AND TOILET ADDITIVES.
2. THE OWNER SHALL CONTRACT WITH A SEPTIC TANK INSPECTOR TO INSPECT THE TANK ANNUALLY FOR GREASE AND
SEDIMENT ACCUMULATION. THE INSPECTOR SHALL REMOVED AND PROPERLY DISPOSED OF ACCUMULATED GREASE
AND SEDIMENT AS NEEDED TO ENSURE PROPER FUNCTION OF THE SYSTEM.
Top View
24"0 PVC
ENCLOSURE
STYROFOAM INSULATED
FIBERGLASS LID WITH
STAINLESS STEEL BOLTS
AND URETHANE GASKET
,-ORENCO 3 ZONE
1-1/4"0 DISTRIBUTING
VALVE ASSEMBLY
(V4403A)
1-1/4"0 SCH.40
PVC FROM PUMP
GRAVEL BASE
Automatic Distributing Valve
Scale: N.T.S.
" 1' MIN
2' MAX CIRCULAR IRRIGATION -STYLE VALVE
GAADF 10 BOX & COVER - LID COLOR PURPLE OR
_ 1%MIN
FILL GREEN -LABEL "SEWER"
_
FINISHED GROUND - MAINTAIN POSITIVE
SLOPE AWAY FROM TOP SURFACE OF
THE CHAMBER TRENCHES,
GRAVELLESS CHAMBER SYSTEM:
INFILTRATOR QUICK 4, ADVANCED aYg
DRAINAGE SYSTEMS BIODIFFUSERDF FILL
(STANDARD), OR ENGINEER _1%MIN
APPROVED EQUAL.-
� I
UNDISTURBED NATIVE SOILS
BOTTOM TO BE LEVEL AND FLAT OVER
ENTIRE AREA TO WITHIN 0.05'-- . (TYP.) MAX.
REMOVE ANY ENCOUNTERED
BOULDERS AND BACKFILL WITH LOAMY
1-1/4"0 PRESSURE DOSING PIPE WITH 5/32"0 -
SAND OR SANDY GRAVELS. DO NOT
HOLES DRILLED EVERY 48" O.C., FACING UP, AND
USE COMPACTED MATERIALS.
ONE (1) HOLE FACING DOWN AT THE END OF
DO NOT WALK ON OR COMPACT
EACH TRENCH (FOR WEEPING). INSTALL A 12"
BOTTOM OF TRENCH.
PAVER OR SPLASH STONE BELOW THE DOWN
FACING HOLE TO PREVENT SOIL EROSION.
6- -
(MIN.)
Pressure Dosing Chamber Trench
Scale: N:T.S.
IRRIG. VALVE BOX
j1"X-1/4" C
4-
REDUCER
1 "0 BALL VALVE &
TREADED ASSEMBLY
FOR BACKFLUSHING
1-1/41 PVC J ` 1-1/4"0 PVC
ELBOW DISTRIBUTION PIPE
Flush Valve
Scale: N.T.S.
STANDARD INSPECTION PORT, TYP. (4"0 PVC
SOLID PIPE CUT TO FIT. LOCATE PER PLAN
VIEW, ATTACH REMOVABLE CAP OR THREADED
CLEANOUT ASSEMBLY.
COUPLING FOR SUPPORT
SYSTEM DESIGN & CONSTRUCTION NOTES:
i. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CDPHE REGULATION 43 ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) REGULATION, MOST CURRENT
EDITION AND LOCAL AGENCY REQUIREMENTS WHICH MAY OR MAY NOT SPECIFICALLY BE NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR
KNOWING AND CONFORMING TO SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. THIS DRAWING DOES NOT CONSTITUTE AN
OWFS PERMIT. A PERMIT MUST BE OBTAINED FROM APPROPRIATE LOCAL AGENCY. THE CONTRACTOR MUST CONTACT THE LOCAL AGENCY HEALTH DEPARTMENT AND
THE PROJECT ENGINEER FOR INSPECTIONS OF THE CONSTRUCTED SYSTEM BEFORE BACKFILL. A REQUEST FOR INSPECTION BY THE PROJECT ENGINEER MUST BE MADE
AT LEAST 48-HOURS PRIOR TO THE EXPECTED TIME OF BACKFILLING.
2. DEMAND CALCULATIONS (SEC.43.6.A.2.h)
2.A. PROPOSED FIVE 5 BEDROOM RESIDENCE USING TREATMENT LEVEL 1 1-1 .
2.B. AVERAGE DAILY WASTEWATER FLOW (ADWF) AND ORGANIC LOAD RATE (BOD,):
2.B.1. SINGLE FAMILY DWELLING: 75 gpdc & 0.20 BOOS Ibs/day
2.B.2. ADWF = 75 gpd * (3 BEDROOMS * 2 PERSONS/BEDROOM + 2 BEDROOM * 1 PERSON) = 600 gpd
2.B.3. BOD5 = 0.20 Ibs/day * (3 BEDROOMS * 2 PERSONS/BEDROOM + 2BEDROOM * 1 PERSON) = 1.60 Ibs/day
BOD5 mg/L = BODa*1,000,000 = 1.60 Ibs/day*1,000,000 = 319.74 mg/L
ADWF*8.34 600 gpd*8.34
2.B.4. CBOD, = BOD5 * 035 = 272 mg/L
3. SEPTIC TANK (SEC.43 9.B.2.a):
3.A. INSTALL A 2,500-GALLON THREE (3) COMPARTMENT STORAGE/DOSING TANK WITH AT LEAST 1,500 OF COMBINED STORAGE IN THE FIRST TWO CHAMBERS (PER
TABLE 9-1) AND A HIGH HEAD DOSING PUMP ASSEMBLY.
3.B. THE TANK IS NOT SUBJECT TO BUOYANCY.
4, ABSORPTION AREA CALCULATIONS;
4.A. THE EXISTING GROUND SLOPE IN THE PROPOSED ABSORPTION AREA SLOPES MODERATELYAT AROUND 1 % ON AVERAGE.
4.B. LONG TERM ACCEPTANCE RATE (LTAR) FOR TREATMENT LEVEL 1 (TL1) OF 0.50 gpd/SF (SEE SITE & SOILS EVALUATION NOTES/DETAIL).
4.C. MINIMUM SOIL TREATMENT AREA, A:
A = ADWF = 600 =1200 S.F.
LTAR 0.50 gpd/S.F.
4.D. SIZE ADJUSTMENT FACTORS: PRESSURE DOSED (PUMP) TRENCH = 0.8; CHAMBER TRENCH = 0.70 (TABLES 10-2 AND 10-3).
4.D.1. A,adi =1200 SF * 03 * 0.7 = 672 SF
4.E. GRAVELLESS CHAMBER TRENCH SYSTEM:
4.E.1. INFILTRATOR QUICK4: 672 SF / 12 SF/UNIT = 56 UNITS IN TRENCH CONFIGURATION, USE 3 TRENCHES OF 19 UNITS EACH (57 TOTAL).
4.E.2. ADS ARC 36: 672 SF / 15 SF/UNIT = 45 UNITS IN A TRENCH CONFIGURATION, USE 3 TRENCHES OF 15 UNITS EACH (45 TOTAL).
5. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS AND/OR FILTERS
SHOULD NOT BE INTRODUCED INTO THIS SYSTEM.
6. CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS AND AT LEAST EVERY 100-FEET BETWEEN THE HOUSE AND THE SEPTIC TANK.
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS THROUGHOUT THE SYSTEM TO PREVENT INFILTRATION.
8. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED.
9. INSTALL 3-INCHES OF BLUEBOARD INSULATION, 3-FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 5-FEET. UNDER NO CIRCUMSTANCES
SHALL COVER BE LESS THAN 2-FEET.
10. SITE PLAN INFORMATION FROM OTHERS. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET
THOSE REQUIRED.
11. PRESSURE DISTRIBUTION DESIGN:
11.A. DOSE SIZE: 30 GALLONS (FLOATS SHALL BE SET BY AN ORENCO AUTHORIZED REPRESENTATIVE)
11.6. PUMP ON TIME 120 SECONDS (15 GPM)
11.C. DOSES PER DAY 20
11.D. TRANSPORT PIPE DIAMETER/MATERIAL:1-1/4"0 SCHAD PVC
11.D. LATERAL PIPE DIAMETER/MATERIAL 1-1/4'0 SCHAO PVC
11.E. ORIFICE SIZE/SPACING: 5/32"0 AT 4' O.C.
11.F. OPERATING HEAD AT THE DISTAL END ORIFICE: 5'
11.G. PUMP INFORMATION: ORENCO MODEL PF3005 HIGH HEAD EFFLUENT PUMP (1/2 HP, 115/23OV,1"0, 6OHz)(DESIGN POINT OF 30 GPM), OR MANUFACTURER
APPROVED EQUAL.
11.H. DRAIN -BACK VOLUME FROM FORCEMAIN;18.6 GALLONS
11.1. DESIGN SOFTWARE REFERENCE: ORENCO SYSTEMS PUMPSELECT V. 220, PUMP DATA FILE 1.15 (2022).
2000 Gallon Top Seam we 3CP
d 1. I will Head
ea :! Pump
t� t �Gallon
DESIGN NOTES
• Design per performance test per
ASTM C1227
• Top surface area 108.88 ft'
• fc 0 28 days; concrete = 6,000
PSI Min.
Installations
• Tank to be set on 5" min. sand bed
or pea gravel
• Tank to be backfilled uniformly on all
sides in lifts less than 24" and
mechanically compacted
• Excavated material may be used for
backfill, provided large stones are
removed
• Excavation should be dewatered and
tank filled with water prior to being
put in service for installation with
water table less than 2' below grade
• Meets C1644-06 for resilient
connectors
• Inlet and Outlet Identified above pipe
• Delivered complete with Internal
• Copntrol Panel to be mounted
sight line of tank
• TRUCK MUST BACK UP
PERPENDICULAR TO LONG SIDI
HOLE, LID IS A SECOND SET
(NO EXCEPTIONS)
• 4' Maximum bury depth
ALLOWABLE BURY
(Based on Water Table)
WATER TABLE
ALLOWABLE
EARTH RLL
0'-0"
2' 0"
1' - 0"
3' - 0"
2' - 0"
3' _ 0'
4' - 0"
DRY
4' - 0"
*Service contracts available for maintenance*
Top View
a� - Section View
Pump:
• Lowers TSS and improves effluent
quality to field
• Complete installation (wining, panel,
mounting and start-up procedures)
• Complete warranty
Digging Specs
Invert
Dimensions
Net Capacity j
Net Weight
19, Long x B' Wide
Inlet Outlet
Length Width Het ht
Inlet SideHMIdl.leOutlet
Total
Lid
Tank
Total
56'.154.'r73"
201"1 78" 1 92"
1583 ga521
gal'. 2621 gal,
6420 Ibs
18590 Ibis
25210 Ibs
Y'`7,
Fax: 719-395-3727
+.
Civil Engineering
Surveying
& 0eyond
m
tee$ I
923 Cooper Avenue
Suite 201
Glenwood
Springs, CO 81601
telex 970.945.5252
fax: 970.384.2833
Engineer Or Surveyor Seal
0
D L CF
�QP
SON Wq! �stt
V.o�211/18/22 T�.Q
37110
s/ONAL��
Client Information:
1JR1EL MELLIN
144 CUFF ROSE WAY
GLENWOOD SPRINGS, CO 81601
970.404.0302
NORTH
0
20' 40'
0
Scale: 1' = 20'
Knowwhat's below.
Call before you dig.
COD
V
Coo
ca
Z
CU
'1r
t
W
V
T� w
0 �
Cn
Cz
c
N
0
Z
T
N
'n
V
-5
to
N
C>
PROJECT NO.
22039
Sheet
FILE NAME:
22039-c-topo.dwg
^ f�
■
DJIVner:
_ . _'(
VV V
raft
DfterV
APL
Date:
11/18/22