HomeMy WebLinkAboutPlansr r r l r / r / r r r ' , o / I , N /' g \� , D I I I I I i i I t ! I I 1-1/4"0 SCHBO PVC / TRANSPORT LINE CDPHE APPROVED 2,500-GALLON , se SLEEVE SEWER LINE 20 LF TO --,EACH SIDE OF WATER SERVICE CROSSING IN 61 SDR35 PVC y v v PRECAST CONCRETE THREE (3) ss s ! CHAMBER SEPTIC TANK WITH LOW PRESSURE DOSING SYSTEM (SEE DETAIL)- 0 410 SCH.40 PVC @2%MIN. 0 I , d�...aq V � � A I 2-WAY CLEANOUT r, f II AT THE BUILDING - "� L- --- SITE EVALUATION SOIL EVALUATION 1. SITE AND SOIL EVALUATIONS WERE PERFORMED BY: 1. THE NATIVE SOILS WERE DERICJ. WALTER, PE DANIEL E HARDIN, PE CLASSIFIED AS TYPE 2A SANDY BOUNDARIES UNLIMITED INC. HPKUMARGEOTECHNICALENG. LOAM (1% GRAVEL, 49% SAND, 923 COOPER AVE., STE. 201 5020 C.R. # 154 40% SILT & 10% CLAY) WITH AN GLENWOOD SPRINGS, CO 81601 GLENWOOD SPRINGS, CO 81601 LTAR OF 0.50 GPD/SF. 970.945.5252 970.945.7988 2. THE NATIVE SOILS CONTAIN 2. EVALUATION DATE(S): NOVEMBER 2018. BOULDERS. WHEN ENCOUNTERED, REMOVED THE BOULDER AND 3. SETBACK REQUIREMENTS FOR A TREATMENT LEVEL 1 STA TRENCH/BED, UNLINED BACKFILL THE VOID WITH LOAMY SAND FILTER OR SEEPAGE PIT (PER TABLE 7-1) AND AN ADWF=600 GPD: SAND OR SANDY GRAVELS. 3.A. SPRING OR WELL=100' 3.B. POTABLE WATER SUPPLY LINE=25' S.C. POTABLE WATER SUPPLY CISTERN=25' 3.D. DWELLING-20' �12' 3.E. PROPERTY LINE, PIPE OR LINED IRRIGATION DITCH =10' SURFACE 3.F.. INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE=25' TOPSOIL 3.G. LAKE, WATER COURSE; IRRIGATION DITCH, STREAM OR WETLAND =50' 3.H. DRY GULCH, CUT BANK OR FILL AREA=25' 3.1. SEPTIC TANK=S' 31 RESTRICTIVE LAYER OR GROUNDWATER (VERTICAL): 4' (TREATMENT LEVEL 1, GRAVITY FEED) LOAM 90ILS 3. SETBACK REQUIREMENTS FOR THE SEPTIC TANK SHALL BE (PER TABLE 7-1): CLAYEY, VERY-' 3.A. SPRING OR WELL=50' SILTY SAND) 3.B. POTABLE WATER SUPPLYLINE=10' 3.C. POTABLE WATER SU PPLY CISTERN = 25' 3.D. DWELLING=T 3.E. PROPERTY LINE, PIPE OR LINED IRRIGATION DII10' 3.F. INTERMITTENT IRRIGATION LATERAL, INFILTRATION STRUCTURE =10' 3.G. LAKE WATER COURSE, IRRIGATION DITCH, STREAM OR WETLAND=50' Site & Soils Evaluation 3.H. DRY GULCH, CUT BANK OR FILL AREA=10' 3.1. STA TRENCH/BED, UNLINED SAND FILTER OR SEEPAGE PII5' Scale: N.T.S. ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. INSTALL MARKER IF CAP IS TO FINISH GRADE BE BURIED. 4"0 PVC 4"0 PVC RISER TWO-WAY CLEANOUT TEE n 4"0 SEWER LINE 0 Cleanout Scale: N.T.S. v j FL VALVE, FLU AL E, TYP. I 25' MIN INSPECTION �0 f v p , PORT, TYP. v� J 6' MIN I xo Y v � i 1 J r ,P' 1-1/4°0 SCH.80 PVC a') 3 ZONE DISTRIBUTION LINES i' DISTRIBUTION VALVE / G , i I� r� ! I I I 3 \ 9 } IT If GENERAL ABSORPTION AREA NOTES 1. INSTALL CHAMBER UNITS IN ACCORDANCE WITH MANUFACTURER'S RECOMMENDATIONS. 2. ABSORPTION TRENCHES SHALL BE 3' WIDE OR LESS AND PARALLEL THE GROUND SURFACE CONTOURS. PARALLELING TRENCHES SHALL BE SEPARATED BY A DISTANCE OF U MIN. 3. THE BOTTOM OF THE ABSORPTION TRENCHES SHALL BE LEVEL AND THE BOTTOM AND SIDEWALLS MUST BE RAKED TO REMOVE ANY SOIL SMEARS INCURRED DURING THE EXCAVATION. FAILURE TO DO SO MAY REQUIRE THE CONTRACTOR TO REPLACE THE ABSORPTION FIELD AT HIS/HER OWN EXPENSE. 4. DRAINAGE SWALES ARE TO BE PROVIDED ABOVE AND AROUND THE FIELD, AS NECESSARY, TO PREVENT SURFACE RUNOFF FROM ENTERING ABSORPTION AREA. 5. NO EXCAVATION OF THE ABSORPTION FIELD IS TO BE DONE DURING WET WEATHER AND USE OF RUBBER TIRE VEHICLES OVER THE ABSORPTION AREA IS STRICTLY PROHIBITED. 6. UNSUITABLE MATERIAL EXISTING WITHIN THE FIELD SHALL BE EXCAVATED AND BACKFILL SHALL CONSIST OF IMPORTED LOAMY SAND OR SANDY GRAVEL. THE ENGINEER SHALL BE CONTACTED IF BEDROCK OR GROUNDWATER IS ENCOUNTERED IN THE OVER -EXCAVATION. 7. TOPSOIL COVER MAY BE VARIED (1-FOOT MINIMUM, 2-FOOT MAXIMUM) TO ALLOW FOR LANDSCAPING. MAINTENANCE NOTES 1. TO ENCOURAGE THE HEALTH AND LONGEVITY OF THE DINTS SYSTEM, THE OWNER SHALL CONSIDER THE FOLLOWING: 1.A. MINIMIZE THE AMOUNT OF WATER THAT GOES DOWN THE DRAIN, THE BETTER YOUR SYSTEM WILL WORK. 1.B. MINIMIZE SOLIDS GOING DOWN THE BRAIN. 1.C. ELIMINATE GARBAGE DISPOSALS OR KEEP THE USE OF GARBAGE DISPOSALS TO A MINIMUM. 1.D. MINIMIZE GREASE AND OILS THAT GO DOWN THE DRAIN. I.E. USE LINT FILTERS ON LAUNDRY MACHINE DRAINS. 1.F. KEEP SAND AND DIRT OUT OF THE BUILDING DRAIN. 1.G. AVOID FLUSHING SANITARY NAPKINS OR PAPER PRODUCTS OTHER THAN TOILET PAPER. 1.H. DO NOT USE LYE -BASED DRAIN UNCLOGGER CHEMICALS SUCH AS DRAINO, OVEN -OFF, OR OTHER STRONG CLEANING AGENTS. 1.1. DO NOT PUT ANY "ROOT DETERRENTS" DOWN THE DRAIN. 1.J. DO NOT POUR PAINT THINNER, PESTICIDES, PAINTS OR PHOTO LAB CHEMICALS DOWN THE DRAIN I.K. MINIMIZE USE OF CHLORINE BLEACH AND TOILET ADDITIVES. 2. THE OWNER SHALL CONTRACT WITH A SEPTIC TANK INSPECTOR TO INSPECT THE TANK ANNUALLY FOR GREASE AND SEDIMENT ACCUMULATION. THE INSPECTOR SHALL REMOVED AND PROPERLY DISPOSED OF ACCUMULATED GREASE AND SEDIMENT AS NEEDED TO ENSURE PROPER FUNCTION OF THE SYSTEM. Top View 24"0 PVC ENCLOSURE STYROFOAM INSULATED FIBERGLASS LID WITH STAINLESS STEEL BOLTS AND URETHANE GASKET ,-ORENCO 3 ZONE 1-1/4"0 DISTRIBUTING VALVE ASSEMBLY (V4403A) 1-1/4"0 SCH.40 PVC FROM PUMP GRAVEL BASE Automatic Distributing Valve Scale: N.T.S. " 1' MIN 2' MAX CIRCULAR IRRIGATION -STYLE VALVE GAADF 10 BOX & COVER - LID COLOR PURPLE OR _ 1%MIN FILL GREEN -LABEL "SEWER" _ FINISHED GROUND - MAINTAIN POSITIVE SLOPE AWAY FROM TOP SURFACE OF THE CHAMBER TRENCHES, GRAVELLESS CHAMBER SYSTEM: INFILTRATOR QUICK 4, ADVANCED aYg DRAINAGE SYSTEMS BIODIFFUSERDF FILL (STANDARD), OR ENGINEER _1%MIN APPROVED EQUAL.- � I UNDISTURBED NATIVE SOILS BOTTOM TO BE LEVEL AND FLAT OVER ENTIRE AREA TO WITHIN 0.05'-- . (TYP.) MAX. REMOVE ANY ENCOUNTERED BOULDERS AND BACKFILL WITH LOAMY 1-1/4"0 PRESSURE DOSING PIPE WITH 5/32"0 - SAND OR SANDY GRAVELS. DO NOT HOLES DRILLED EVERY 48" O.C., FACING UP, AND USE COMPACTED MATERIALS. ONE (1) HOLE FACING DOWN AT THE END OF DO NOT WALK ON OR COMPACT EACH TRENCH (FOR WEEPING). INSTALL A 12" BOTTOM OF TRENCH. PAVER OR SPLASH STONE BELOW THE DOWN FACING HOLE TO PREVENT SOIL EROSION. 6- - (MIN.) Pressure Dosing Chamber Trench Scale: N:T.S. IRRIG. VALVE BOX j1"X-1/4" C 4- REDUCER 1 "0 BALL VALVE & TREADED ASSEMBLY FOR BACKFLUSHING 1-1/41 PVC J ` 1-1/4"0 PVC ELBOW DISTRIBUTION PIPE Flush Valve Scale: N.T.S. STANDARD INSPECTION PORT, TYP. (4"0 PVC SOLID PIPE CUT TO FIT. LOCATE PER PLAN VIEW, ATTACH REMOVABLE CAP OR THREADED CLEANOUT ASSEMBLY. COUPLING FOR SUPPORT SYSTEM DESIGN & CONSTRUCTION NOTES: i. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH CDPHE REGULATION 43 ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) REGULATION, MOST CURRENT EDITION AND LOCAL AGENCY REQUIREMENTS WHICH MAY OR MAY NOT SPECIFICALLY BE NOTED ON THE DRAWINGS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR KNOWING AND CONFORMING TO SUCH SPECIFIC DETAILS AS ARE REFERRED TO IN THE ABOVE MENTIONED REGULATIONS. THIS DRAWING DOES NOT CONSTITUTE AN OWFS PERMIT. A PERMIT MUST BE OBTAINED FROM APPROPRIATE LOCAL AGENCY. THE CONTRACTOR MUST CONTACT THE LOCAL AGENCY HEALTH DEPARTMENT AND THE PROJECT ENGINEER FOR INSPECTIONS OF THE CONSTRUCTED SYSTEM BEFORE BACKFILL. A REQUEST FOR INSPECTION BY THE PROJECT ENGINEER MUST BE MADE AT LEAST 48-HOURS PRIOR TO THE EXPECTED TIME OF BACKFILLING. 2. DEMAND CALCULATIONS (SEC.43.6.A.2.h) 2.A. PROPOSED FIVE 5 BEDROOM RESIDENCE USING TREATMENT LEVEL 1 1-1 . 2.B. AVERAGE DAILY WASTEWATER FLOW (ADWF) AND ORGANIC LOAD RATE (BOD,): 2.B.1. SINGLE FAMILY DWELLING: 75 gpdc & 0.20 BOOS Ibs/day 2.B.2. ADWF = 75 gpd * (3 BEDROOMS * 2 PERSONS/BEDROOM + 2 BEDROOM * 1 PERSON) = 600 gpd 2.B.3. BOD5 = 0.20 Ibs/day * (3 BEDROOMS * 2 PERSONS/BEDROOM + 2BEDROOM * 1 PERSON) = 1.60 Ibs/day BOD5 mg/L = BODa*1,000,000 = 1.60 Ibs/day*1,000,000 = 319.74 mg/L ADWF*8.34 600 gpd*8.34 2.B.4. CBOD, = BOD5 * 035 = 272 mg/L 3. SEPTIC TANK (SEC.43 9.B.2.a): 3.A. INSTALL A 2,500-GALLON THREE (3) COMPARTMENT STORAGE/DOSING TANK WITH AT LEAST 1,500 OF COMBINED STORAGE IN THE FIRST TWO CHAMBERS (PER TABLE 9-1) AND A HIGH HEAD DOSING PUMP ASSEMBLY. 3.B. THE TANK IS NOT SUBJECT TO BUOYANCY. 4, ABSORPTION AREA CALCULATIONS; 4.A. THE EXISTING GROUND SLOPE IN THE PROPOSED ABSORPTION AREA SLOPES MODERATELYAT AROUND 1 % ON AVERAGE. 4.B. LONG TERM ACCEPTANCE RATE (LTAR) FOR TREATMENT LEVEL 1 (TL1) OF 0.50 gpd/SF (SEE SITE & SOILS EVALUATION NOTES/DETAIL). 4.C. MINIMUM SOIL TREATMENT AREA, A: A = ADWF = 600 =1200 S.F. LTAR 0.50 gpd/S.F. 4.D. SIZE ADJUSTMENT FACTORS: PRESSURE DOSED (PUMP) TRENCH = 0.8; CHAMBER TRENCH = 0.70 (TABLES 10-2 AND 10-3). 4.D.1. A,adi =1200 SF * 03 * 0.7 = 672 SF 4.E. GRAVELLESS CHAMBER TRENCH SYSTEM: 4.E.1. INFILTRATOR QUICK4: 672 SF / 12 SF/UNIT = 56 UNITS IN TRENCH CONFIGURATION, USE 3 TRENCHES OF 19 UNITS EACH (57 TOTAL). 4.E.2. ADS ARC 36: 672 SF / 15 SF/UNIT = 45 UNITS IN A TRENCH CONFIGURATION, USE 3 TRENCHES OF 15 UNITS EACH (45 TOTAL). 5. THIS SYSTEM IS SIZED FOR TYPICAL DOMESTIC WASTES ONLY. BACKWASH OR FLUSHING FLOWS FOR REVERSE OSMOSIS UNITS OR WATER SOFTENERS AND/OR FILTERS SHOULD NOT BE INTRODUCED INTO THIS SYSTEM. 6. CLEAN OUTS ARE REQUIRED AT THE HOUSE AND AT ALL BENDS AND AT LEAST EVERY 100-FEET BETWEEN THE HOUSE AND THE SEPTIC TANK. 7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING ALL WATER TIGHT COMPONENTS THROUGHOUT THE SYSTEM TO PREVENT INFILTRATION. 8. INSTALL RISERS AS NECESSARY TO BRING ALL ACCESS PORTS TO FINAL GRADE. PORTS SHALL BE MARKED IF CAPS ARE TO BE BURIED. 9. INSTALL 3-INCHES OF BLUEBOARD INSULATION, 3-FEET WIDE, OVER SEWER AND EFFLUENT PIPE WHEREVER DEPTH IS LESS THAN 5-FEET. UNDER NO CIRCUMSTANCES SHALL COVER BE LESS THAN 2-FEET. 10. SITE PLAN INFORMATION FROM OTHERS. LOCATIONS OF ALL COMPONENTS MAY BE VARIED AS NECESSARY AS LONG AS ALL MINIMUM DISTANCES AND SLOPES MEET THOSE REQUIRED. 11. PRESSURE DISTRIBUTION DESIGN: 11.A. DOSE SIZE: 30 GALLONS (FLOATS SHALL BE SET BY AN ORENCO AUTHORIZED REPRESENTATIVE) 11.6. PUMP ON TIME 120 SECONDS (15 GPM) 11.C. DOSES PER DAY 20 11.D. TRANSPORT PIPE DIAMETER/MATERIAL:1-1/4"0 SCHAD PVC 11.D. LATERAL PIPE DIAMETER/MATERIAL 1-1/4'0 SCHAO PVC 11.E. ORIFICE SIZE/SPACING: 5/32"0 AT 4' O.C. 11.F. OPERATING HEAD AT THE DISTAL END ORIFICE: 5' 11.G. PUMP INFORMATION: ORENCO MODEL PF3005 HIGH HEAD EFFLUENT PUMP (1/2 HP, 115/23OV,1"0, 6OHz)(DESIGN POINT OF 30 GPM), OR MANUFACTURER APPROVED EQUAL. 11.H. DRAIN -BACK VOLUME FROM FORCEMAIN;18.6 GALLONS 11.1. DESIGN SOFTWARE REFERENCE: ORENCO SYSTEMS PUMPSELECT V. 220, PUMP DATA FILE 1.15 (2022). 2000 Gallon Top Seam we 3CP d 1. I will Head ea :! Pump t� t �Gallon DESIGN NOTES • Design per performance test per ASTM C1227 • Top surface area 108.88 ft' • fc 0 28 days; concrete = 6,000 PSI Min. Installations • Tank to be set on 5" min. sand bed or pea gravel • Tank to be backfilled uniformly on all sides in lifts less than 24" and mechanically compacted • Excavated material may be used for backfill, provided large stones are removed • Excavation should be dewatered and tank filled with water prior to being put in service for installation with water table less than 2' below grade • Meets C1644-06 for resilient connectors • Inlet and Outlet Identified above pipe • Delivered complete with Internal • Copntrol Panel to be mounted sight line of tank • TRUCK MUST BACK UP PERPENDICULAR TO LONG SIDI HOLE, LID IS A SECOND SET (NO EXCEPTIONS) • 4' Maximum bury depth ALLOWABLE BURY (Based on Water Table) WATER TABLE ALLOWABLE EARTH RLL 0'-0" 2' 0" 1' - 0" 3' - 0" 2' - 0" 3' _ 0' 4' - 0" DRY 4' - 0" *Service contracts available for maintenance* Top View a� - Section View Pump: • Lowers TSS and improves effluent quality to field • Complete installation (wining, panel, mounting and start-up procedures) • Complete warranty Digging Specs Invert Dimensions Net Capacity j Net Weight 19, Long x B' Wide Inlet Outlet Length Width Het ht Inlet SideHMIdl.leOutlet Total Lid Tank Total 56'.154.'r73" 201"1 78" 1 92" 1583 ga521 gal'. 2621 gal, 6420 Ibs 18590 Ibis 25210 Ibs Y'`7, Fax: 719-395-3727 +. Civil Engineering Surveying & 0eyond m tee$ I 923 Cooper Avenue Suite 201 Glenwood Springs, CO 81601 telex 970.945.5252 fax: 970.384.2833 Engineer Or Surveyor Seal 0 D L CF �QP SON Wq! �stt V.o�211/18/22 T�.Q 37110 s/ONAL�� Client Information: 1JR1EL MELLIN 144 CUFF ROSE WAY GLENWOOD SPRINGS, CO 81601 970.404.0302 NORTH 0 20' 40' 0 Scale: 1' = 20' Knowwhat's below. Call before you dig. COD V Coo ca Z CU '1r t W V T� w 0 � Cn Cz c N 0 Z T N 'n V -5 to N C> PROJECT NO. 22039 Sheet FILE NAME: 22039-c-topo.dwg ^ f� ■ DJIVner: _ . _'( VV V raft DfterV APL Date: 11/18/22