Loading...
HomeMy WebLinkAboutBuilding SpecsSTATE OF COLORADO Jan-2019 Name of Manufacturer:Plant I.D. Number: Complete Address: Contact Name:Contact Number: Contact Email address: Third Party Inspection Agency: Model Name/No. Sq. Footage Finished: Sq. Footage Unfinished: Approval Stamp EXPIRES: MANUFACTURER CERTIFIES that only approved equipment and materials will be used and the installations shall be made in accordance with approved plans and applicable codes and provisions of the Colorado Division of Housing. Manufacturer agrees to in-plant inspection of units manufactured under the above plan approval. Application shall be made for and insignia affixed to each factory built unit that is subject to Colorado statutes and which is manufactured or is to be sold, offered for sale, or occupied in the State of Colorado. DIV. OF HOUSING, 1313 SHERMAN STREET, RM 320, DENVER, CO. 80203 (303) 864-7836 Fax (303) 864-7857 Cover Sheet for Building Specifications & QA Manual For more detailed information on this plan approval please contact the Division of Housing 1313 Sherman St., Rm 320, Denver, CO 80203 | (303) 864-7810 | cdola.colorado.gov/housing The following is based on information provided to the Division of Housing (DOH) and may be modified based on the actual findings of the field inspection. Site Address:_____________________________________________________________ DATE: MANUFACTURER: ID NO.: CONTACT: PHONE NO.: MODEL NO.: DOH P/A NO.: INSPECTION REQUIREMENTS: Check on site: “AC” Inspection Local Inspection Electrical connection to the building AC Breaker Panel provided by others. REV Issued for. .. 0 Construction ENGINEERING & CONSTRUCTION SERVICES, INC. Structural Calculations Wood Group USA 4057 Camelot Circle Longmont, CO 80504 Wood Group Job No. 6655-DAD-22006 Xcel Energy 10'x14' Control Building Rifle, CO ZAP Project Number: 22057-22006 ·�oBt,9;., .VS20 ', f' � AUTHOR CHECK ZJR APPROVED DATE 07/11/22 Structural Calculations 22057-22006-SE-CAL-0 1 07/11/2022 Overview Control Building ZAP ECS Project Number 22057-22006 Scope: Perform a shuctural analysis and design to determine the structural members required for the I0'xl4' Control Building. The shucture will be designed for two conditions : hoisted and foundation supported. When hoisted, the building shall have no snow, wind, seismic or live loads present. The foundation supported condition will be designed for snow, wind, seismic, floor live, and roof live loads. The design of the building foundation and anchorage are not included in this calculation. Data: Location - Rifle, CO I.Roof: a.Dead Load = Strnctural element self-weight b.Snow Load = 47 psf c.Live = 20 psf 2.Lateral Loads: a.Wind = 120mph, Exposure C b.Seismic: So s = 0.321g, Soi = 0.075g, I = 1.25, Site Class D, Design Category B 3.Floor: a.Dead Load= Self weight b.Live Load = 125 psf 4.AtHoist: a.Dead Load = Self weight ofstrncture References: I.AISC 360-10 2.AISI Sl00-12 3.IBC 2018 4.ASCE 7-16 5.Wood Group USA Assembly Drawings 6.USGS Seismic Data Computer Programs: RISA-3D Version 19.0.1 07/13/2022 Conclusion: All strnctural elements are adequate in strength and deflection. Refer to drawings in Attachment 1 for member sizes, orientation, and dimensions. Owner shall provide anchorage to foundation at (4) perimeter locations of skid. Refer to maximum loads in the "Max Anchor Reactions" section for foundation and anchorage design forces. ZAP Engineering & Consh·uction Services, Inc. U-Factor Calcs. 1/25 (R-Factor) = 0.040 U-Value 8/3/2022 MANUFACTURER:WOOD GROUP, USA ID:4157 STREET ADDRESS:4057 CAMELOT CIRCLE CITY, STATE, ZIP:LONGMONT, CO 80504 MODEL NO:.10'X 14' CONTROL BLDG. SERIAL NO.:3741 NO. OF MODULES:1 INTERNATIONAL BUILDING CODE:2018 NATIONAL ELECTRIC CODE:2020 INTERNATIONAL MECHANICAL CODE:2018 INTERNATIONAL ENERGY CODE:2015 WIND - MPH:120 WIND EXP:C ROOF (LIVE) PSF:20 ROOF (SNOW) PSF:43.4 FLOOR AREA - SQ. FT.:140 FLOOR (LIVE) PSI:125 GROUND SNOW LOAD - PSI:47 SEISMIC DESIGN CATEGORY:B OCCUPANCY GROUP:S-2 CONSTRUCTION TYPE:V-B FLOOR R-VALUE:25 WALL R-VALUE:25 ROOF R-VALUE:25 EXTERIOR FIRE RATING:N/A BUILDING SEPARATION DISTANCE:10' AMPS:100 VOLTS:120/240 PHASE:SINGLE MODEL LABEL NO. CODES BUILDING DATA PLATE DESIGN LOADS & CRITERIA ELECTRIC PANEL