HomeMy WebLinkAboutConditions of Permit - RevisedCOND ITIONS OF PERMIT
BLRE-10 -20-6541 As Revised
Relandco, LLC
Remodel of Existing Building into an Office and Apartment
L7352 HwY 82
Carbondale, Colorado
1) ALL WORK SHALL COMpLy WITH THE 201-5 lBC, lMC, lPC, IFGC AND 2009 lFc & lEcc' AND lN
ACCORDAN CE WITH MAN U FACTU RER,S I NSTALLATIO N I NSTRU CTIONS & REQU I REM ENTS'
SEE ALSO 2015 IEBC.
2) REFER TO PLAN ATTACHMENTS FOR GARFIELD COUNTY,S BUILDING REQUIREMENTS AND
INSPECTIONS POLICY.
3) WORK SHALL COMpLy wtTH LAND USE PERMIT GAPA-01--21-8824 REGULATIONS AND
CONDITIONS OF APPROVAL. BUILDINGS ARE APPROVED AS TYPE V-B CONSTRUCTION WITH
MTXED-USE OCCUpANCTES tNCLUDING: OFFICE (GROUP B), AND RESIDENTIAL (GROUP R-3).
4) CONTACT LOCAL FtRE D|STR|CT FOR r.F.C. REQUIREMENTS INCLUDING FIRE ALARM
SYSTEMS, SPRINKLER SYSTEMS, AND SMOKE ALARMS. ROUGH IN AND FINAL APPROVAL
REPORT FROM FIRE DISTRICT IS REQUIRED PRIOR TO ROUGH IN AND FINAL BUILDING
INSPECTION BY COUNTY.
5) ACCESS|BtLTy REQUIREMENTS PER 2Ol-5 lBC, CHAPTER 11, AND ICC 4117.1--2009'
(NOTE: ACCESSIBtLITY ls Nor REQUTRED AT UPPER LEVEL RESIDENTIAL UNIrS PER SECTION
r!04.4, EXCEPTION #4).
6)LOCKS,LATCHES&LAND|NGSPER20l"5lBc,sEcTloN1010'
7l LIGHT AND VENTILATION PER 2015 lBC, CHAPTER L2'
s) BUtLDtNG MECHANTCAL SYSTEMS (COMBUSTION AlR, DUCTWORK & VENTING)TO COMPLY
wtrH TNTERNATTONAL MECHANTCAL CODE (rMC)AND IECC, SECTION 503. MECHANICAL
ROUGH-IN INSPECTION REQUIRED PRIOR TO FRAMING INSPECTION.
9) pLUMBtNG REQUTREMENTS pER TNTERNATIONAL PLUMBING CODE (lPC). PLUMBING
ROUGH-IN INSPECTION REQUIRED PRIOR TO FRAME INSPECTION.
L0) ELECTRTCAL REQUIREMENTS, PERMITTING AND INSPECTIONS BY COLORADO STATE
ELECTRICAL BOARD. ELECTRICAL ROUGH_IN APPROVAL IS REQUIRED AT FRAME INSPECTION
ELECTRICAL FINAL APPROVAL REQUIRED FOR FINAL BUILDING INSPECTION & CERTIFICATE
OF OCCUPANCY.