HomeMy WebLinkAboutConditions of PermitCONDITION OF PERM¡T
BLRE-02-23-7 980
David & Rhonda Jensen
s cAJr| [r| E Dew
s
"s, ";j"iljå3ffi:ïtîK:åffi! "o sa rase
Springridge Reserve, Ph.1, Lot22
1) ALL WORK SHALL COMpLy W|TH THE 201s TNTERNATIONAL RESTDENTTAL CODE (l.R.C.)
AND 2009 TNTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C.)
2) PROPOSED TMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED lN ÏHE
ATTACHED "GARFI ELD COU NTY BU I LDING REOUIREMENTS". NU MBER REFERENCES
NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERMtTTtNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD.
ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL
FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4't WILDFIRE MITIGATION REOUIREMENTS: COMPLY WITH WILDFIRE MIïIGATION AND
DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL
FIRE DISTRICT.
5) OPEN HOLE SOTLS REPORT rS REOUTRED AT FOOTING TNSPECTTON AND PRIOR TO ANY
CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE
BUILDING INSPECTOR. 1,500 PSF
ó) pRE-ENctNEERED ROOF TRUSSES. HAVE ENGINEERING FOR BUILDING INSPECTOR AT
TIME OF FRAME INSPECÏION.
7) PLAN (A 01) |ND|CATES OVERALL ROOF AREA (AND RESULTTNG FIRE AREA) NOT GREATER
THAN 3,555 SOUARE FEET. AS SUCH THIS PERMIT IS FOUND TO BE "EXEMPT" FROM
RESIDENTIAL FIRE SUPPRESSION REOUIREMENTS. HOWEVER, ANY FUTURE BUILDING
CHANGES THAT RESULT IN AN ACCUMULATIVE AMENDED FIRE AREA OVER 3,óOO SO FT -.
MAY CAUSE THE ENTIRE RESIDENTIAL LIVING SPACE TO BECOME FIRE SPRINKLERED AÏ
TIME OF FUTURE WORK. CURRENT AND FUTURE OWNERS TO READ THE ATTACHED PLAT
(RECEPTTON 681074