February 20, 2023 Project No. C1708
Maureen O’Brien
Up4walk@yahoo.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
24 CR 111
Garfield County, Colorado
Permit Number SEPT-7608
Maureen,
CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) on October 10 and
February 19, 2023 for the subject property. Dale Kruse installed the system.
The OWTS design is based on 2-bedrooms. An average daily wastewater flow of 300 GPD was used.
A ditch runs along Hwy 133 to the west. No OWTS components came within 50-feet of the ditch.
Setbacks to the STA include 20-feet from the residence and 10-feet from the property line. This site is
constrained was likely a slight encroachment on the setbacks to the house and property lines.
However, the OWTS components were not surveyed for exact distances.
There is a grinder pump in the lower level of the residence. The grinder pump was not included in the
scope of this design but within the scope of plumbing work inside the residence.
A 4-inch diameter SDR-35 sewer line with a single-sweep clean out and minimum 2% fall to the septic
tank exits the residence.
The system installation included a 1000-gallon, two-compartment concrete Forterra septic tank with an
Orenco® Biotube Pump Vault and an Orenco® PF3005 pump in the second compartment of the septic
tank. The floats were set to dose approximately 66 gallons per pump cycle. The control panel for the pump
is within line of sight of the septic tank.
Effluent is pumped through a 1.5-inch diameter pump line from the pump chamber to an Orenco®
automatic distributing valve (ADV), model 6402. The ADV was placed at a high point in the system in an
insulated riser with access from grade.
Effluent is pressure dosed through 1.5-inch diameter distribution lines to a 13’ x 29’ bed. A minimum of 3-
feet of sand filter material was installed in the over-excavated footprint. A gradation of the sand media is
enclosed.
Laterals are 1.5-inches in diameter with 5/32-inch diameter orifices facing down, spaced 2-feet on center,
surrounded by screened rock. Laterals were placed 2-feet from the edges of the bed with 3.0-feet between
the middle laterals.
Each 1.5-inch diameter lateral ends in a sweeping ell facing up with a ball valve for flushing. Valves were
placed in a 10-inch sprinkler box for access. Laterals were covered by the soil separation fabric and at
3-12-2023
least 1-foot of topsoil. Inspection ports were placed at each corner of each bed. Ports may be cut to
grade and covered with a valve box for access.
At the time of our February 16, 2023 inspection, we tested the pump and cycled through the ADV.
Flushing valves were opened to verify proper functioning of the system.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS
in the future. Any additional OWTS construction must be according to the county regulations.
LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent on the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
CBO Inc. Reviewed By:
Carla Ostberg, MPH, REHS Romeo Baylosis, P.E.
Laterals were turned so the orifices and shields are facing down
Downward facing orifices
View of septic tank Pump line exiting tank
Pump line secured to side of foundation (installer choice) / sewer line existing foundation
Rise of pump line
Forterra septic tank
Sewer line and clean out (single sweep) Pump line
Sewer line entering septic tank ADV
View of pump chamber (will add handle extensions) Control panel
Control panel Flushing valves
View of STA looking toward house ADV
Flushing valves Control panel
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs,CO 81601
Phone:970)945 6614 ext.8150
For inspections,call:970 945 6614 ext.8150 and call the Design Engineer,if applicable
Project Address:24 County Road 111,Carbondale,CO 81623
Parcel No.:246303400049
Owner Name:Maureen Anne O’Brien Owner Phone:970)989 4439
Designed By:CBO Septic Consulting,Inc.Designer Phone:970)309 5259
Number of Bedrooms 2__Minimum Tank Capacity 1,000 gal__Minimum Absorption_375 SF
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number SEPT 7608________________________
Permit Type X New X Repair X Remodel/addition X Tank only X Field Only X Amendment
Issue Date 07/15/2022 Expiration Date 07/15/2023
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the design as submitted by CBO
Septic Consulting,Inc.dated April 19,2022.Changes must be approved by Garfield County Public
Health and the designer prior to construction.
The new OWTS will serve a new two bedroom residence.The system will consist of a new,two
compartment 1,000 gallon septic tank set level with access to grade with a high head pump in the
second chamber of the tank.Effluent will be pressure dosed to an Automatic Distributing Valve to
distribute effluent to 377 ft2 of STA.The new STA will consist of an unlined sand filter bed
constructed of 3 feet of secondary sand material.The pump and effluent lines will be constructed of
1.5 inch diameter Schedule 40 PVC.The laterals in the bed shall have 5/32 inch diameter orifices
facing down spaced every 2 feet on center O.C.),installed on GeoMat placed directly on the sand.
Inspection ports are to be installed at each corner of each bed.Maintain all setbacks and elevations
as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit,the applicant hereby agrees to comply with all
laws and regulations related to the zoning,location,construction and erection of the proposed
OWTS and associated structures for which this permit is granted.The applicant further agrees
that if the above said regulations are not fully complied with in the zoning,location,erection
and construction of the above described OWTS and structure,the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability,nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system.Permit issuance will
not constitute a certification that the system,the equipment used in the system,or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act,the regulations adopted thereunder,or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory.Permission is hereby given to the property owner(s)to perform the work indicated
in accordance with the Garfield County OWTS Regulation.This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced.An as built"drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
07/15/2022
Issued By:Garfield County Environmental Health
Department
Date
832‐R‐13‐002