HomeMy WebLinkAboutEngineer's Framing Letter 03.09.2023KURTZ & ASSOCIATES, INC. STRUCTURAL CONSULTANTS
5012 County Road 154 Phone (970) 945 6305
Glenwood Springs, CO 81601
MEMORANDUM
To: Garfield County Date: March 09, 2023
Attn: Building and Planning Department
Re: Reboul Residence: 7006 County Road 312,
Garfield County, CO.
This memo is in response to observed conditions which were noted during the course of a
Feb. 28, 2023framing inspection. This memo specifically addresses the roof and ceiling
framing at the garage wing.
1. Photo 001: Sloping `I' joist rafters bear in standard joist hangers. The joist hangers
require horizontal bearing. Add wood shims and glue the shims with full contact surface
carpenter's wood glue.
2. Photo 002: Sloping `I' joist rafters bear on a horizontal LVL beam. Add a beveled
2 x4 plate to improve the `I' joist bearing and nail the 2 x4 with 16d nails at 8" O.C.
3. Photo 003: Inclined built-up post from ceiling level beam up to ridge beam. Provide
HGA-10 angle (Simpson Strong Tie, Co.) each side post.
4. Photo 004: `I' joist rafters framing to LVL hip. Improve connection by installing
glued and nailed web stiffener: Stiffener to be 7/16" thick x full web height x 4" glued
with carpenter's full contact glue + (3) — 16d nails. Attach `I' joist to LVL hip with
skewable LS-90 framing angle (Simpson, Strong Tie, Co.).
5. Photo 005: Over -framed rafters which are butted rather than lapped. Add LTP-5
framing plate (Simpson Strong Tie, Co.) to attach butted rafters to one another.
6. Photo 008: LVL hip frames to ridge beam and post. Improve the hip bearing
connection with the installation of (2) — HGA-10 angles. Seat -cut hip at bearing points
and attach (1) — HGA-10 to ridge beam, and (1) to post.
7. Over -framing studs at north end of wing. Provide (1) additional row of horizontal
bracing so that all studs are braced.
If you have any further questions, feel free to call.
Kurtz & Associates, Inc.
Brian J. Kurtz, P.E.
pIDO,L/c�,Tr
�,