HomeMy WebLinkAboutPermit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 1157 CR 237, Silt, CO 81652 Parcel No.: _212736200069
Owner Name: Kevin and Kimberly Bogan Owner Phone: (970) 314-0489
Designed By: Capstone Enterprises LLC Designer Phone: (970) 250-3331
# of Bedrooms: 5 Minimum Tank Capacity: 1,500-gallon Minimum Absorption: 1,008 ft 2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT-8012_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _04/13/2023____________________ Expiration Date_04/13/2024_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by Capstone Enterprises LLC dated June 21, 2020 and revised April 10, 2023. Changes to
the design and permit must be approved by Garfield County Public Health and the designer prior to
construction.
The new OWTS will serve a new 5-bedroom residence. The new OWTS components will consist of a
new, two-compartment 1,500-gallon septic tank set level with access to grade and an effluent filter
installed in the outlet tee of the tank. Effluent will gravity flow to the tank, then to a distribution box
set level with access to grade that will distribute effluent to 1,008 ft 2 of STA. The new STA will consist
of one four-row gravelless chamber bed 12 ft wide by 88 ft long, each row consisting of 21 Infiltrator
Quick4 chambers (84 chambers total). Distribution laterals will consist of 4-in perforated pipe.
Inspection ports will be installed at each corner of each bed. Maintain all setbacks and elevations as
designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as-built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
04/13/2023
Issued By: Garfield County Environmental Health
Department
Date