HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-03 -23-8042
Joseph & Leslie Vossmer
New S/F Dwelling w/ attached garage
52 Eagle Claw Circle, GWS
lronbridge, PH 2, FLG 1,2&3, Blk 3, Lot 252
1) ALL WORK SHALL COMply W|TH rHE2015 TNTERNATIONAL RESIDENTIAL CODE
(r.R.c.)AND 2009 INTERNATIONAL ENERGY CONSERVATION CODE (l.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED
IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER
REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL PERMtTTtNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC
BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION.
ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION &
CERTI FICATE OF OCCU PANCY.
4) Wl LDFIRE M lTlcATlON REOUIREMENTS: COMPLY WITH WILDFIRE MITIGATION
AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE
AND LOCAL FIRE DISTRICT.
5) A LOT TMPROVEMENT CERTIFICATE, SEALED BY A COLORADO LICENSED
SURVEYOR, IS REOUIRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE -
INCLUDING ROOF OVERHANGS, DECKS AND OTHER PROJECTIONS -- IS WHOLLY
CONTAINED WITHIN SETBACKS AND PLATTED BUILDING ENVELOPE.
ó) oPEN-HOLE SOTLS REPORT ANp STRUCTURAL FlLt COMPACTION REPORT
MUST BE PREPARED BY THE GEOTECHNICAL ENGINEER OF RECORD. 1,500 PSF
SOIL BEARING CAPACITY. GENERAT CONTRACTOR MUST SUPPLY
GEOTECHNICAL REPORT TO GARFIELD COUNTY BUILDING INSPECTOR AT
UNDERGROUND PLUMBING INSPECTION.
7) STRUCÍURAL ENGTNEER SHALL BE RESPONSTBTE FOR FIEID OBSERVATION
AND ¡NSPECTION OF REBAR/CONCRETE MAT SIAB FOUNDATION. GENERAL
CONTRACTOR SHAtt PROVIDE ENGINEER'S SEALED APPROVAT REPORT (WET
STAMPED & SIGNED) PR¡OR TO FRAMING INSPECTION.
s) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERTNG FOR INSPECTOR AT TIME
OF FRAME INSPECTION.