HomeMy WebLinkAboutCondition of PermitCONDITIO NS OF PERMIT
BLRE-03 -23-8044
LU K KEY VENTU RES LLC
Single-Family Dwelling Unit with attached gurage
224 Limberpine Circle, Battlement Mesa
Canyon View Subdiv. PH 1, Blk 1, Lol27
1) ALL WORK SHALL COMply W|TH THE 2015 TNTERNATIONAL RESIDENTIAL
coDE 1r.n.c.)AND 2009 INTERNATTONAL ENERGY CONSERVATTON CODE
(r.E.c.c.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS
CONTAINED IN THE ATTACHED "GARFIELD COUNry BUILDING
REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO
SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL PERMITING AND INSPECTIONS BY COLORADO STATE
ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT
FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL
INSPECTION & CERTIFICATE OF OCCUPANCY.
4) WILDFIRE MITIGATION RECOMMENDATION: SHOULD COMPLY WITH
WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS PER
COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE
REFER TO THE GARFIELD COUNry COMMUNIry DEVELOPMENT WEBSITE
FOR ADDITIONAL I NFORMATION.
5) pRE FABRTCATED ROOF TRUSSES. HAVE ENGTNEERTNG FOR INSPECTOR AT
TIME OF FRAME INSPECTION.
ó) opEN HOLE SOTLS REPORT tS REOUTRED AT FOOTTNG INSPECTION AND
PRIOR TO ANY CONCRETE POUR. 1,500 PSF SOIL BEARING. PROVIDE
COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING
INSPECTOR INCLUDING COMPACTION REPORT FOR STRUCTURAL FILL.
7) A LOT TMPROVEMENT CERTIFICATE, SEALED BY A COLORADO LICENSED
SURVEYOR, IS REOUIRED AT FOUNDATION INSPECTION TO VERIFY
STRUCTURE - INCLUDING ROOF OVERHANGS, DECKS AND OTHER
PROJECTIONS - IS IN COMPLIANCE WITH MINIMUM SETBACKS AND/OR
BUILDING ENVELOPE REOUIREMENTS.