HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-04-23-80ó9
SCHWAB BASEMENT FINISH PROJECT
126White Peaks Ln, Carbondale
lronbridge, Lot 139 - 239512418139
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)AND 2OO9
I NTERNATIONAL EN ERGY CONSERVATION CODE ( I. E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRICAL PERN/tTTlNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) BASEMENT FtNtSH WORK COMPLETED WITHOUT A BUILDING PERMIT AND WITHOUT INSPECT¡ONS.
EXISTING AND / OR ALTERED ROUGH-IN PLUMBING / MECHANICAL / ELECTRICAL / FRAMING
MEMBERS MAY BE CONCEALED IN DRYWALL OR OTHER FLOOR / WALL / CEILING COVERING.
5) tT SHALL BE AT GARFTELD COUNry BUtLDING INSPECTION DISCRETION -- BASED UPON OBSERVED
SITE CONDITIONS - TO REOUIRE ANY CONCEALED AREAS COVERED BY DRYWALL TO BE OPENED
FOR INSPECTION AND LIFE SAFEry REVIEW. ANY AREAS FOUND TO BE UNSAFE OR HAZARDOUS
TO HUMAN OCCUPANCY OR HEALTH MAY REOUIRE CORRECTION PERFORMED BY COLORADO
LICENSED PLUN/BING / ELECTRICIAN AND/OR APPROVAL BY A COLORADO LICENSED STRUCTURAL
ENGINEER.
6) VERIFY SMOKE DETECTORS AND CARBON MONOXIDE ALARMS ARE INSTALLED THROUGHOUT THE
EXISTING HOUSE PURSUANT TO 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)SECTIONS R314
AND R315.
7) VERIFY BASEMENT AND BASEMENT BEDROOM EGRESS NET CLEAR OPENINGS COMPLY WITH 2O15
I.R.C. SECTION R310. VERIFY, BASEMENTWINDOWWELLS,IFANYAPPLY, CON/IPLYWITH R310.2.3
VERIFY 44 INCH MAXIMUN/ SILL HEIGHT FROM BASEMENT EN/ERGENCY ESCAPE AND RESCUE
OPENINGS.
8) VERTFY HABITABLE ROOMS lN BASEMENT N/lAlNTA|N 7 FT CEILING HEIGHT
9) VERIFY, IF ALTERED, CONTINUOUSLY GRASPABLE HANDRAIL IS INSTALLED ACCESSING THE
FINISHED BASEMENT.
10) vERtFy, tF WALKOUT BASEMENT, EX|T DOORS MAINTAIN CODE COMPLIANT DOOR THRESHOLD,
DOOR LANDING, DIRECTION OF DOOR SWING PURSUANT TO 2015 I,R,C. SECTION R31 1.
1 1) VER|Fy, OUTDOOR COMBUSTTON AIR lS MAINTAINED TO EXISTING / NEW MECHANICAL EOUIPMENT
AND APPLIANCES WHERE INSTALLED WITHIN THE BASEMENT SPACE.
12) VERIFY, EXISTING / PROPOSED APPLIANCES WITHIN THE BASEMENT ARE APPROPRIATELY VENTED
AND TERMINATED OUT OF THE BUILDING. OWNER SHALL SUPPLY EOUIPMENT MANUFACTURER'S
SPECIFICATIONS AND INSTALLATION INSTRUCTIONS FOR ANY APPLIANCES OR EOUIPMENT
INSTALLED WITHOUT PRIOR PERMIT.
13) COUNTERTOP SURFACE SPACE IN WET BAR AREA SHALL NOT EXCEED 25 SO FT. VERIFY NO FULL
SIZE KITCHEN APPLIANCES ARE INSTALLED IN THE BASEMENT.