HomeMy WebLinkAboutOriginal OWTS Site Plan - 03.08.2023PEABODY, RACHEL REVOCABLE TRUST6780 HIGHWAY 82, GLENWOOD SPRINGSPARCEL No. 239t01 1{0¡58.ù\zrNËLSON, ALAN E & MTHRYN I6776 HIGHWAY 82, GLENWOOD SPRINGSPARCEL No. 2395-011-00{10ERIC1-OO-O12SPRINGSPARCEL NO.6778 HIGHWAYì.PARCEL No. 2395-011-00-13582, GLENWOOD SPRINGSLLCI 00'70-_\BUILDING 1 .BUILDING 2o,|vl2.0PROPERTY LINSEPTICTANKNDRAWINGS MUST BE USED INCONJUNCTION WITH DESIGNLETTER DATED O3IO8I2O23SCALE: 1 = 50'=0"6694 HWl 82 LLC6694 HIGHWAY 82, GLENWOODPARCEL No. 239541 1 -00-134AY s2THE LOCATION OF PROPOSED IMPROVEMENTS SHOWN ARENOT THE RESULT OF A PROPERTY SURVEY. THE LOCATIONSARE APPROXIMATE. IT IS THE HOMEOWNERS' DUTY TOENSURE ALL CONSTRUCTION AND IMPROVEMENT LOCATIONSARE ACCURATE. PROPERTY LINES AND SETBACK DISTANCESSHOULD BE CONFIRMED PRIOR TO EXCAVATION. SCALEDFOR PRINTING ON 11" X I7" PAPER.A SITE PLAN1'=50'-O'CALL 811 FORUTILITY LOCATESCBO lnc.129 Cains LaneCarbondale, Colorado 81 623Phone 970.309.5259carla.ostberg@gmail.comThunder Ridge Business Center6762 Hwy 82Garfield County, ColoradoProject Number: C1792Date: 0310812023Designed by: CBOReviewed by: KRCDrawn by: DDw1 .0Sheet 1 0F 4 6780 HrP6778ooMIN5'10')IN6,000 q froBUILDING 1FF 105'EXISTING SEEPAGE PITTO BEABANDONEDVi----=-EXISTING SEEPAGE PITTO BEABANDONED4" DIA SCHED-4O SEWER PIPEWITH CLEANOUTMIN 2% FALL TO TANKo12' x 37' PRESSURE DOSED, OVER-EXCAVATED, UNLINEDSAND FTLTER (MtN. 2'ASTM C-33 CONCRETE SAND)WITHTHREE 1.5' DtA SCH-40 PVC LATERALS W|TH $' Otnn¡etenORIFICES FACING DOWN,3'O.C COVERED WITH ORIFICESHIELDSEXISTINGSEPTIC TANKSTO BEABANDONEDBUILDING 2FF 100'FLUSHING VALVE ATEND OF EACH LATERAL\r/\llINSPECTION PORTS ATCORNERS OF BEDICLEANOUTN4' DIA SCHED-4o SEWERPIPE WITH CLEANOUTMIN 2% FALL TO TANK1 OOO-GALLON 2-COMPARTMENTCONCRETE SEPTIC TANK WITHAN ORENCO PUMP PACKAGE INTHE SECOND COMPARTMENT,RISERS AND LIDS TO GRADEN6776 HPPERry LINE1.5" DIA SCH.4O PUMP LINE.(MrN 1% DRA|N BACK TO TANK)t\ \ \1.5- DIA SCH-40 LEVEL MANIFOLDEXISTING SEEPAGE PITTO BE ABANDONEDIA SCH-40 Da\LINESEACHTP+PROPOSEDUTIcHCBO lnc.129 Cains LaneCarbondale, Colorado 81623Phone 970.309.5259carla.ostberg@gmail.comThunder Ridge Business Center6762 Hwy 82Garfield County, ColoradoProject Number: C1792Date: 03/08/2023Designed by: CBOReviewed by: KRCDrawn by: DDw2.0Sheet 2 0F 4 END EACH LATERAL IN A 90' LONG SWEEPING ELL FACING UP WITH A BALL VALVE IN A VALVE BOX ACCESSIBLE AT GRADE 1.5" DIA SCH-40 PVC LA FLUSHING VALVES INSPECTION PORT AT EACH CORNER NATIVE GRADE LANDSCAPE FABRIC ON GRAVEL GRAVEL FILTER MEDIA MIN. 6-INCHES UNDER LATERALS MIN. 2-INCHES OVER LATERALS 12' x 37' PRESSURE DOSED UNLINED SAND FTLTER (MlN. 2'ASTM C-33 coNcRETE SAND) W|TH THREE 1.5' DIA SCH-40 PVC LATERALS WITH 5/32' DtA ORTFTCES (W|TH ORIFTCE SHTELD) FACING DOWN AT 3'O.C. 1.5' DIA SCH-40 PUMP LINE (MrN 1% DRA|N BACK TO PUMP CHAMBER) 1.5- DIA SCH-40 LEVEL MANIFOLD INSPECTION PORT AT EACH CORNER OF BED INSTALL FLUSHING VALVE ECCENTRIC TO CENTER OF VALVE BOX TO TANK - NG VALVE DETAIL FINISHED GRADE TO HOUSE 1O' DIA VALVE BOX WITH SECURED LID 1.5' PVC SLIP X MALE PIPE THREAD ADAPTER WCAP 1.5' DIA BALL VALVE 1.5' DtA SCH-40 PVC LONG SWEEP 90'ELBOW GRAVEL MEDIA 1.5" DtA SCH-40 PVC LATERAL SLIP-ON PVC CAP DO NOT GLUE INSULATED TRACER WIRE 4'DIA SEWER LINE l,L WITH 5/32'' DIA ORIFICES FACING DOWN AT 3'O.C. INSTALL ORIFICE SHIELDS UNDER EACH ORIFICE N, SAND FILTER I\4ATERIAI .SECONDARY SAND" EFFECTIVE SIZE = 0.15 - 0.60 mm UNIFORMITY COEFFICIENT 57.0 % F|NES PASSTNG #200 S|EVE:3.0 SAND FIL w3.0 LTERFSAND CBO lnc. 129 Cains Lane Carbondale, Colorado 81623 Phone 970.309.5259 carla.ostberg@gmail.com 6762Hwy 82 Garfield County, Colorado Project Number: C1792 Thunder Ridge Business Center 03t08t2023 esigned by: CBO Reviewed by: KRC Drawn by: DD Sheet 3 0F 4 DESIGN (21 CoMMERCTAL OFFTCE BUTLDTNGS TOTAL 16 POTENTIAL 8-HOUR OFFICE EMPLOYEES 16 EMPLOYEES x 15 GPD = 24O GPD ESTIMATED WASTEWATER FLOW DESIGN WASTEWATER FLOW = 350 GPD TANK: MIN. lOOO GALLONS USE lOOO-GALLON, TWO-COMPARTMENT CONCRETE SEPTIC TANK WITH AN ORENCO PUMPING SYSTEM IN THE SECOND COMPARTMENT SOIL TREATMENT AREA (STA): LONG TERM ACCEPTANCE RATE (LTAR) = 0.8 GAL/ SF CALCULATED STA = Q/LTAR = 350 / 0.8 = 437.5 SF 12'x37'OVER-EXCAVATED, UNLINED SAND FILTER WITH MlN. 2'SAND FILTER MATERIAL SOIL PROFILE TEST PIT NO. I ROAD BASE AND FROZEN TOPSOIL REDDISH BROWN SANDY LOAM NO GROUNDWATER OR BEDROCK ENCOUNTERED DURING EXCAVATION SETBACK CHART 0 1 2 LEGEND F road base and topsoil l,--l sand' 3 4 5 b 7 I FINISHED GRADE F- tU UIIL IFfL I.IJo SLIP-ON PVC CAP DO NOT GLUE 4' DIA SDR-35 INSPECTION PIPE STA FIL MEDIA SPRINKLER VALVE BOXAT GRADE FINISHED GRADE 114" DIA HOLE DRILLED INTO TWO SIDES OF PIPE FOR VENTILATION (BELOW SL|P ON CAP) 4' DIA SCH-40 SEWER LINE (MrN 2% SLOPE TO TANK) SCREENED ROCK OR SAND FOR BEDDING 24" MtN 3'MrN. I 8'MIN INS P L w4.0 OWTS COMPONENTS AND PHYSICAL FEATURES MINIMUM REQUIRED SETBACK APPROXIMATE PROPOSED SETBACK SEPTIC TANK TO BUILDING #2 5'6' SEPTIC TANK TO WELL 50'246', SEPTIC TANK TO WATER COURSE 100'N/A STA TO BUILDING #2 SLAB 10'11', STA TO WELL 1 00'236', STA TO WATER COURSE 1 00'N/A BACKFILL CBO lnc. 129 Cains Lane Carbondale, Colorado 81 623 Phone 970.309.5259 carla.ostberg@gmail.com 6762Hwy 82 Garfield County, Colorado Project Number: C1792 Thunder Ridge Business Center Date: 0310812023 Designed by: CBO Reviewed by: KRC Drawn by: DD 10 Sheet 4 OF 4