HomeMy WebLinkAboutPermit - Revised  Garfield County Public Health  2014 Blake Ave.   Glenwood Springs, CO 81601  Phone: (970) 945‐6614 ext. 8150  For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable   Project Address: TBD Donegan Road, Glenwood Springs, CO 81601    Parcel No.: 218505100121  Owner Name: Emanuel A. Rivas Ayula     Owner Phone: (970) 366‐1963  Designed By: CBO Septic Consulting, Inc.      Designer Phone: (970) 309‐5259  Contractor: Cuelta Construction     Contractor Phone: (970) 404‐0302            Number of Bedrooms _5__Minimum Tank Capacity _1,500‐gal__Minimum Absorption_840 SF  OWTS PERMIT   KEEP AVAILABLE AT PROJECT SITE   Permit Number _SEPT‐7759 Revised____________________  Permit Type X New X Repair X Remodel/addition X Tank only X Field Only X Amendment   Issue Date 05/12/2023    Expiration Date 05/12/2024   Permit Conditions:   This OWTS Permit is approved on the condition of compliance with the revised design as submitted  by CBO Septic Consulting, Inc. dated May 3, 2023. Changes must be approved by Garfield County  Public Health and the designer prior to construction.     The new OWTS will serve a new 5‐bedroom residence. The system will consist of a new, two‐ compartment minimum 1,500‐gallon septic tank set level with access to grade and an effluent filter  in the outlet tee of the tank. Effluent will gravity flow to a distribution box set level with access to  grade that will distribute effluent to 864 ft2 of STA. The new STA will consist of two gravelless  chamber beds. Each bed will consist of three rows of 12 Quick4 chambers, for a total of 36 Quick4  chambers per bed and 72 chambers total. Inspection ports shall be installed at each corner of each  bed. Maintain all setbacks and elevations as designed.    Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final  inspection of the installed system prior to backfill.      Agreement   All installations must comply with all requirements of the Garfield County OWTS regulations  including but not limited to the conditions specified above.   In consideration of the issuance of the permit, the applicant hereby agrees to comply with all  laws and regulations related to the zoning, location, construction and erection of the proposed  OWTS and associated structures for which this permit is granted. The applicant further agrees  that if the above said regulations are not fully complied with in the zoning, location, erection  and construction of the above described OWTS and structure, the permit may then be revoked  by notice from the Health Department and immediately become null and void.  The issuance of a permit and specifications of terms and conditions therein will not constitute  assumption of liability, nor create presumption that the local public health agency or its  employees may be liable for the failure or malfunctioning of any system. Permit issuance will  not constitute a certification that the system, the equipment used in the system, or any  component used for system operation will ensure continuous compliance with the provision of  the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.   Permit Approval  Plans and specifications for the proposed OWTS have been reviewed and are considered  satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated  in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from  the date of issuance unless construction on the system has commenced. An "as‐built" drawing  must be submitted and inspection of the system must be completed by GCPH before final  approval of the system will be issued.        05/12/2023  Issued By: Garfield County Environmental Health  Department  Date