HomeMy WebLinkAboutPermit - Revised
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945‐6614 ext. 8150
For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: TBD Donegan Road, Glenwood Springs, CO 81601
Parcel No.: 218505100121
Owner Name: Emanuel A. Rivas Ayula Owner Phone: (970) 366‐1963
Designed By: CBO Septic Consulting, Inc. Designer Phone: (970) 309‐5259
Contractor: Cuelta Construction Contractor Phone: (970) 404‐0302
Number of Bedrooms _5__Minimum Tank Capacity _1,500‐gal__Minimum Absorption_840 SF
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT‐7759 Revised____________________
Permit Type X New X Repair X Remodel/addition X Tank only X Field Only X Amendment
Issue Date 05/12/2023 Expiration Date 05/12/2024
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the revised design as submitted
by CBO Septic Consulting, Inc. dated May 3, 2023. Changes must be approved by Garfield County
Public Health and the designer prior to construction.
The new OWTS will serve a new 5‐bedroom residence. The system will consist of a new, two‐
compartment minimum 1,500‐gallon septic tank set level with access to grade and an effluent filter
in the outlet tee of the tank. Effluent will gravity flow to a distribution box set level with access to
grade that will distribute effluent to 864 ft2 of STA. The new STA will consist of two gravelless
chamber beds. Each bed will consist of three rows of 12 Quick4 chambers, for a total of 36 Quick4
chambers per bed and 72 chambers total. Inspection ports shall be installed at each corner of each
bed. Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as‐built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
05/12/2023
Issued By: Garfield County Environmental Health
Department
Date