HomeMy WebLinkAboutEngineer's Design LetterLICENSED PROFESSIONAL ENGINEERS HOME AND BUILDING INSPECTION STRUCTURAL EVALUATION DESIGN COMMUNITY ASSOCIATION SERVICES ® Cona Engineers LLC Independently Owned and Operated 6400 S Fiddlers Green Cir Suite 250 Greenwood Village, CO 80111 309.339.8045 Phone May 31st, 2023 Aspen Foundation Repair 732 Buckhorn Dr Unit B Rifle, CO 81650 47 White Peaks Ln Glenwood Springs, CO 81601 RE: Structural Inspection To Whom It May Concern; In accordance with your request, we reviewed the structural requirements for the subject address. The property was visited on Thursday, 05/18/2023 by Joe O’Neil, P.E. The scope of work was determined by Aspen Foundation Repair and accepted by the owner prior to the involvement of Criterium-Cona Engineers. DESCRIPTION All descriptions of the structure are based on observation from White Peaks Ln. The front of the structure is assumed to face east for the purpose of this report. The subject structure is a two-story home reportedly built in 2005. The home is wood-framed construction with lapped siding and board and batten exterior. Structure has a complex gable/hip-style, asphalt-shingle roof with gutters and downspouts for drainage. There is an attached two- car garage on the left side of the home. The foundation of the home is a concrete stem wall and an assumed footer. The footer could not be directly observed. No foundation or as- built construction drawings were available for review for this project. No soils testing was available for this report. LICENSED PROFESSIONAL ENGINEERS HOME AND BUILDING INSPECTION STRUCTURAL EVA LUATION DESIGN COMMUNITY ASSOCIATION SERVICES ® Cona Engineers LLC Independently Owned and Operated 6400 S Fiddlers Green Cir Suite 250 Greenwood Village, CO 80111 309.339.8045 Phone ANALYSIS There is significant cracking in the dry wall as observed from the interior of the structure. Dry wall cracks emanate generally from corners of building openings in the rea, right, and front interior walls. Significant cracking has extended into the ceiling. Significant dry wall cracking that is extensive and pervasive throughout the interior of the structure signifies likely foundation settlement. PROJECT SCOPE Structural modifications included in this project is the planned installation of forty-five (45) Supportworks Model 288 push piers to provide stability to the perimeter foundation walls of the main structure and attached garage. Installation of the piers is intended to resist further downward movement of the structure. Confirmation of the original stem wall and footer foundation design must be relayed to the engineer prior to any attempt to lift the structure. No lift will be attempted without authorization by the engineer. No lift will be recommended if foundation design is discovered to be a grade beam and pier construction. Please see enclosed drawing # PRJ23025 – 1, 2 for design details associated with this project. CONCLUSION AND LIMITATIONS This report is valid only for the address and the project scope listed, by the client listed above. The observations described in this document are valid for the date of the observation and have been made under the conditions noted in the report. Use by any other entity or for any other purpose is prohibited, without the express, written consent of the undersigned engineer. This report is based on published and anecdotal information; variations from the anticipated soil profiles may be encountered; contact the engineer immediately if they are discovered. This report does not cover geological hazards, such as LICENSED PROFESSIONAL ENGINEERS HOME AND BUILDING INSPECTION STRUCTURAL EVALUATION DESIGN COMMUNITY ASSOCIATION SERVICES ® Cona Engineers LLC Independently Owned and Operated 6400 S Fiddlers Green Cir Suite 250 Greenwood Village, CO 80111 309.339.8045 Phone slope stability or landslide. Such investigations require extensive investigative techniques and are well outside the scope of this report. Should such information be desired, contact the engineer for guidance in obtaining it. This report does not express or imply any warranty of the future performance of the structure or drainage condition. This report should not be considered a warranty of condition, and no warranty is implied. The opinions and recommendations presented in this report are based solely on visual observations available for viewing at the time of the site visit and information, if any, provided by the Client and/or their representative(s). We are not responsible for conditions that were not within the scope of our services at the time of inspection. We did not undertake or perform any destructive or invasive testing. No additional subsurface testing, material testing, calculations, nor monitoring over time of the conditions presented in this report are included in this project, but may be obtained, if desired, under separate agreement. Not included in this site visit was a review of the architectural, mechanical, electrical, plumbing, cosmetic, landscaping, drainage or structural conditions, other than those items specifically discussed, nor a comprehensive review of compliance with applicable building codes. The work covered by this project is not held out as being a complete repair for all known or suspected structural or foundational issues within the building; other work may be justified or needed, but work not included is outside the scope of this project. If it is required at a future date, it will be under a separate contract. This report has been prepared for your benefit and in strict confidence with you as our client. No reproduction or reuse of this report for the benefit of others is permitted without expressed written consent, except as may be required by Colora do real estate regulation. Further, except as required by real est ate regulation, we will not release this report to anyone without your consent. LICENSED PROFESSIONAL ENGINEERS HOME AND BUILDING INSPECTION STRUCTURAL EVA LUATION DESIGN COMMUNITY ASSOCIATION SERVICES ® Cona Engineers LLC Independently Owned and Operated 6400 S Fiddlers Green Cir Suite 250 Greenwood Village, CO 80111 309.339.8045 Phone Regards, Joe O’Neil-PE 0057038 joneil@criterium-cona.com attachment- drawings #PRJ23025 - 1, 2 STAMPED 05/31/23