HomeMy WebLinkAboutEngineer's Framing Letter 06.12.2023Re:
E llar En Inc.
320 Main St., Suite 203
Carbondale, CO 81623
Phone (970) 963-3223
erniekollar@gmail.com
June 12,2023
To: TrevorRuonavaara
Lot 54 Spring Ridge
Garfield County, CO
Trevor:
Regarding the framing at the above referenced location, we have the following
comments:
1. At the back porch where the roof was lowered, the ledger detail is adequate;
however, it appears from the photo that the rafters were installed without hangers
The last rafter at the edge ofthe shed roofdoes not appear adequately supported.
To rectiff, please add an A35 to one side of each rafter, where they attach to the
ledger.
,.v
'=*-,
b
A
2. In the crawl space where the posts bear on the footings, the treated distribution
plate is adequate if attached to the footing with2 fasteners. Add 435's to each
side of the post to secure the post to the distribution plate.
Please call with any questions,
t "æ¿¿Ka//at,
Ernest Kollar, PE
435
435's
0 LI
(J
70362
ètnøt
At