Loading...
HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-o6-23-815ó Chris Morrow & Linda Hassall 1 ,200 sq ft ADU w/ attached garage 4190 CR 103, Carbondale - 239118200034 1) ALL WORK SHALL COMpLy W|TH THE 2015 TNTERNATIONAL RESTDENTTAL CODE (l.R.C.)AND 2009 I NTERNATIONAL EN ERGY CONSERVATION CODE (I.E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL pERM|TTING AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE REOUIREMENTS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNIry DEVELOPMENT WEBSITE FOR MORE INFORMATION. 5) OPEN-HOLE SOILS REPORT MUST BE PREPARED BY GEOTECHNICAL ENGINEER OF RECORD. SUPPLY REPORT TO GARFIELD COUNTY BUILDING INSPECTOR AT FOOTING INSPECTION. 1,500 PSF SOIL BEARING CAPACITY, ó) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGINEERTNG FOR INSPECTOR AT TIME OF FRAME INSPECTION. 7) OWNER BUTLDER tND|CATES NO ATTTC ACCESS OPENTNGS AND NO MECHANICAL EOUIPMENT LOCATED IN ATTIC AREAS. FIELD VERIFY ATTIC MEETS DIMENSIONAL REOUIREMENTS TO BE CONSIDERED EXEMPT FROM INSTALLING ACCESS OPENING UNDER 2015 IRC SECTION R8O7 (OR SHALL INSTALL ATTIC ACCESS OPENINGS WHEREVER CODE REOUIRES). 8) ROOF AND ATTTC TNSULATTON TO BE TNSTALLED rN BOTTOM TRUSSES AFTER DRYWALL CEILING LID IS IN PLACE. BUILDING INSPECTOR MUST BE PROVIDED ACCESS TO ROOF OR ATTIC INSULATION. OWNER BUILDER MAY NEED TO PROVIDE A LADDER FOR THE BUILDING INSPECTOR. INSULATION INSTALLER TO POST INSULATION CERTIFICATE PRIOR TO INSULATION INSPECTION (POSTING ON GARAGE WALL RECOM M ENDED). 9) AMENDED FLOOR PLAN A-101: INCLUDES DELETION OF FRONT DECK, NEW EXIT DOOR LANDINGS, MECHANICAL EOUIPMENT & APPLIANCE LOCATIONS. 10) BËDROOM EMERGENCY ESCAPE & RESCUE OPENTNGS SHALL COMPLY WITH 2015 IRC SECTION R310. 1 1) SAFETY cLAZ|NG (TEMPERED ETCHTNG) tS REOUIRED lN HAZARDOUS LOCATIONS PER 2015 IRC SECTTON R308.4 #1-8. 12) VER|Fy FENESTRATTON U-FACTOR COMPLTES WITH U- 0.35 (OR LESS) lN ACCORDANCE WITH THE 2009 IECC PRESCRIPTIVE COMPLIANCE PATH AND GARFIELD COUNry CLIMATE ZONE 58. 13) R31 1 .3.1 FLOOR ELEVATTONS AT THE REOUTRED EGRESS DOORS. OUTWARD SWING DOORS ARE DEPICTED OVER EXIT DOOR LANDINGS. FIELD VERIFY'1 % INCH MAXIMUM CHANGE IN LEVEL. 14) SEPTIC SYSTEM REVIEW i APPROVALS: PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY PROVIDE FINAL APPROVAL / SIGN.OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH DEPT.