HomeMy WebLinkAboutObservation of Excavation 02.17.2023lcrtHmmffü"*5020 County Road 154 Glenwood Springs, CO 81601 phone: (970) 945-7988 fax: (970) 945-8454 email: kaglenwood@kumarusa.com An Employcc OwrËd ComPonY www.kumarusa.com Office Locations: Denver (HQ), Parke¡ Colorado Springs, Fort Collins, Glenwood Springs, and Summit County, Colorado February 17,2023 Jordan Kobielusz 3602 County Road 108 Carbondale, Colorado 81 623 icservices2l@yahoo'com project No. 23-7-14g Subject: Observation of Pit Excavations, Proposed Residence, 3602 County Road 108, Garfield County, Colorado Dear Jordan: As requested, the undersigned representative of Kumar & Associates observed the pit excavations at the subject site on February 10,2023 to evaluate the soils exposed for foundation support. The findings of our observations and recommendations for the foundation support are presented in this report. The services were performed in accordance with our agreement for professional engineering services to you dated February 10,2023. The proposed residence will be one-story modular house over a crawlspace. The proposed leach field will be located south of the residence. The site is located on a broad low ridge in a pinon forest. An existing driveway provides access to the site. There were parked vehicles and equipment at the site to the north of the building area. At the time of our visit to the site, the site had been cleared of pinon trees. Three pits were excavated with a Bobcat E45 mini-excavator. The subsurface conditions observed in the three pits were similar and consisted of about 1 foot of organic silty sand topsoil overlying 3 to 4 feet of reddish-brown, relatively dense, silty sandy gravel with scattered cobble-size sandstone rock fragments (weathered sandstone/siltstone). Refusal to backhoe digging was encountered in all three pits at about 4 to 5 feet on sandstone/siltstone bedrock of the Maroon Formation. The results of gradation analyses performed on samples of silty sandy gravel (minus 5-inch fraction) obtained from the site are presented on Figures 1 and 2. No free water was encountered in the excavations and the soils were slightly moist to moist. Considering the conditions exposed in the pit excavations and the nature of the proposed construction, spread footings placed on the undisturbed natural soil designed for an allowable soil bearing pressure of 2,500 should be adequate for support ofthe proposed residence. The exposed soils were dense and post-construction settlement of the foundation should be less than I inch. Footings should be a minimum width of 16 inches for continuous walls and 2 feet for columns. Loose and disturbed soils in footing areas should be removed and the bearing level extended down to the undisturbed natural soils. The bearing soils should be protected against frost and concrete should not be placed on frozen soils. Exterior footings should be provided with adequate soil cover above their bearing elevations for frost protection. Continuous Jordan Kobielusz February 17,2023 Page2 foundation walls should be reinforced top and bottom to span local anomalies such as by assuming an unsupported length of at least 10 feet. Foundation walls acting as retaining structures (if any) should also be designed to resist alateral earth pressure based on an equivalent fluid unit weight of at least 45 pcf for on-site soil as backfill. A perimeter foundation drain should be provided to prevent temporary buildup of hydrostatic pressure behind the crawlspace walls and prevent wetting of the crawlspace. Structural filIplaced can consist of the on-site soils compacted to at least 95% of standard Proctor density at a moisture content near optimum. Backfill around the structure and the surface graded to prevent wl at least 10 feet of the building. Based on the subsurface conditions encountered in the profile pit (1 foot of topsoil overlying 4 feet of gravelly sandy loam), the proposed septic area should be suitable for a shallow conventional infiltration septic disposal system. We recommend the infiltration area be oversized due to the relatively shallow weathered sandstone. A civil engineer should design the infiltration septic disposal system. The recommendations submitted in this letter are based on our observation of the soils exposed within the pit excavations. The risk of foundation movement may be greater than indicated in this report because of possible variations in the subsurface conditions. We should observe the completed foundation excavation at the time of construction. Our services do not include determining the presence, prevention or possibility of mold or other biological contaminants (MOBC) developing in the future. If the client is concerned about MOBC, then a professional in this special field of practice should be consulted. If you have any questions or need further assistance, please call our office. Sincerely, Kumar & Associates, Daniel E. Hardin, Rev. by: SLP DEHlkac attachments Figurc 1- Gradation Test Results Figure 2 - USDA Gradation Test Results z (talz Kumar & Associates, lnc. @ Project No. 23-7-148 SIEVE ANALYSISHYDROMETER ANALYSIS I CLEAR SOUARE OPENIT{GS s/a' 3/a' I 1/2' 3' U.S. SÎANDÀRO SERIES ltô ¡¡5'8' It1 ÍIME RÊAOINOS Z¡l HRS 7 HRSMrN eñurÍ rour!tvtN ai ı ei to0 90 ao 70 EO 50 ¡ao 30 20 to o o lo 20 50 10 50 60 70 80 90 100 - Ê. p H .00t .075 9.5 2.O ETER OF PARTICLES IN M CLAY TO SILT COBBLES GRAVEL 21 % SAND LIQUID LIMIT SAMPLE OF: Very Silty Grovolly Sond 10% PLASTICITY INDEX SILT AND CLAY 36 % FROM: Plt 1 @ 2' to 3' Th6so l€sl r€sulls opp¡y only lo lho sqmples wh¡ch w€rs l€slsd. Tho losl¡ng roporl sholl not b6 r€producod, excepl ln full, wllhoul lhe wrlllsn opprovol of Kumor & Assocloles, lnc' Sievs qnolysls lesi¡nq ls pcrlormod ln occordoncã wlth ASTM 06913, ASTM D7928, ASTM c156 ond/or ASIM Dl1,lo. GRAVELSAND MEDIUM COARSE FINE COARSEFINE 23-7-1 48 Kumar & Associates GRADATION TEST RESULTS Fig. 1 SIEVE ANALYSISHYDROMETER ANALYSIS TIME READINGS SERIES CLEAR UARE 2AHR. 7HR 1 MIN, .#325 #140 #60 #35 #18 #'10 #4 3/8' 314" 1 112',5b ð ^45U MIN,100 10 90 20 80 30 70 oLIz. =F lJJu Fz UJ()É l¡JÀ 40 60 ()z6 tt7 o- t-z L¡JOÉt¡lfL 50 50 60 40 70 30 80 20 90 10 100 106 .025 .500 1.00 2.00 4.75 9.5 19.0 37.5 76.2 152 203.001 .002 ,005 ,009 .019 .045 DIAMETER OF PARTICLES IN MILLIMETERS CLAY COBBLES GRAVEL 35 o/o SAND 26 %SILT 31 o/o CLAY 8 % USDA SOIL TYPE: Gravelly SandY Loam FROM: Profile Pit at 4 to 5 feet ==_y'_ - - + t.--- V. FINE FINE SAND r\4EDtUt\4SILT 23-7 -1 48 Kumar & Associates USDA GRADATION TEST RESULTS Fig.2