Compl iance Cert¡ficate
Project Altonaga Residence
Energy Code: 2018 IECC
Location: Garfield County, Colorado
Construction Type: Single-family
Project Type: New Construction
Conditioned Floor Area; 3,506 ft2
Glazing Area L2o/o
Climate Zone: 5 (8499 HDD,
Permit Date:
Permit Number: 07-23-8191
frn buridml #ø
re20rl
Compliance: 5.470 Bettêr Than Çode Maximum UA: 634 Your UA: 600
The % Better or Worse Than Code lndex reflects how close to compllance the house ls based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home,
Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade
assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements.
Envelope Assemblies
Construction Site:
15 Sweetgrass Drive
Carbondale. co 8L623
Ceiling: Raised or Energy Truss
Wall: Wood Frame, 16" o.c.
Door: Glass Door (over 50% glazing)
Window: Metal Frame W Thermal Break
Wall l.: Wood Frame, 16" o,c.
Window 1: Metal Frame WThermal Break
Wall 2: Wood Frame, 16" o-c.
Window 2: Metal Frame W Thermal Break
Wall 3: Wood Frame, 16" o.c.
Window 3: Metal Frame w/Thermal Break
Wall 4: Wood Frame, 16" o.c.
Wall 5: Wood Frame,24" o.c.
Door l": Solid Door (under 50% glazing)
Owner/Agent:
Bill Altonaga
L403 Great Belt Circle
Melbourne, FL 32940
32r-344-4037
galtonaga@gmail.com
Designer/Contractor:
Brad Jordan
jordan architecture inc.
po box 1031
glenwood springs, CO 81602
9706r.86690
bradjorda narc hitect@9 mai l.com
4,324
844
150
4L
747
68
L,237
2LL
470
20
722
235
24
49.0
21.O
2L.0
2L.0
21,0
2r..0
2r.,0
0.0
0.0
0.020
0.057
0.320
0.280
0.057
0.280
0.057
0.280
0.057
0.280
0.057
0.056
3.000
0.026
0.060
0.300
0.300
0.060
0.300
0.060
0.300
0.060
0.300
0.060
0.060
0,300
86
37
48
Ll
39
L9
58
59
!t2
39
45
L2
4t
20
62
63
0.0
0.0
0.0
0.0
26
6
7
t2
72
0.0 27
6
7
L3
7
Compliance: Passes using UA trade-off
Cavity
R-Value
Cont.
R-Value
Prop. Req,
U-Factor U-Factor
Prop
UA
Req
UA
Gross Area
Assembly or
Perimeter
Project Title: Altonaga Residence
Data filename:
Report date: O8lO3l23
Page L of10
Gross Area
or
Perirneter
Ca vity
R-Value
Cont.
R-Value
Prop.
U-Fattut
Req.
U-FåctrrI
Prop,
UA
ReqAssemblvUA
Wall 6: Wdod Frame, 24" o.c.
Wall 7: Wood Frame. 24" o.c.
Wall 8: Wood Frame, 24" o.c.
Crawl Wall: Solid Concrete or Masonry
Wallheight: 3.0'
Depth below grade: 2.5'
lnsulation depth: 3.0'
Compliance Statementi I he proposed
calculations submitted with the permit
REScheck Version : REScheck-Web and
me-
0.0
3,506 19,0 10.0 0.035 0.0s5 102 16r.
escr¡bed here is consistent with the
has
102
122
93
2L.0
21.0
21.0
0.0
0.0
0.056
0.056
0.056
0.060
0.060
0.060
6
7
5
6
7
6
to comply with ma REScheck lnspection Checklist.
ß¿,,s J (L¿a/ </zg
Date
Proiect Title: AltonaEa Residence
Data filename:
Report date: 08/03/23
Page 2 oft0
REScheck Software Version : REScheck-Web
lnspection Checklist
Energy Code: 2018 IECC
Requírements: 0.0% were addressed directly in the REScheck software
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Add itional Comments/Assum ptions:
Section
#
& Req,lD
Pre-lnspection/Plan Review Plans Verifled
Value
Field Verified
Value Complies?Comments/Assumptions
103.1,
103.2
lPRl-11
s,
energy code compliance for the
building envelope. Thermal
envelope represented on
construction documents,
,UNot
,flruot
I Construct¡on drawings and
: documentation demonstrate
rElcomplies
lflooes lr¡ot
Observable
Applicable
103.1,
103.2,
403.7
lPR3ll
,{ù,
Construction drawings and
documentation demonstrate
energy code compliance for ì
lighting and mechanical systems. ,
Systems serving multiple
dwelling units must demonstrate i.
compliance with the IECC
Commercial Provisions.
Complies
EDoes Not
iENot observableiENot Applicable
,Heating and cooling equipment is
sized per ACCA Manual S based
on loads calculated per ACCA
, Manual J or other methods
,approved by the code official.
Heating:Btu/hr_
Cooling:Btu/hq_;flNot Observable
iEruot npplicable
i
Heati n9Btu/hr_
Coo tn9Btu/hr_
iE
plies
Does Not
L,
403.7
lPR212
{8,
1 hlm (Tier 1)2 Medium lm (Tier 2)3 Low lmpact (Tier 3)
Project Title: Altonaga Residence
Data filename:
Report date: 08/03123
Page 3 of10
R-R.
R.R-_
itr
iE
if'lNot
lLlNot
402.2.LL iUnvented crawl space wall
insulation R-value
igee t¡é Enûelope Assemblles
iæ,þle for values.lFoTlr
Õ
c,orhplies
Does Not
Observable
Applicable
303.2
IFO8]tt
Unvented crawl space wall
insulation installed per
manufacturef s instructions.
Not
Complles
Observable
Applicable
402.2.LL
IFOglr
ry
Unvented crawl space continuous
vapor retarder installed over
exposed earth, joints overlapped
by 6 in. and sealed, extending at
least 6 in. up and attached to the
wall.
lies
Not
Obseruåble
Applicable
Unvented crawl space wall
insulation depth of burial or
distance from top of wall.
.2.tL
IFO10]1
Õ
tn tn See the Envelope Assemblies
table for values.Not
Observable
A protective covering is installed
to protect exposed exterior
insulation and extends a
minimum of 6 in. below grade.
Nôt
Observable
Applicable
Snow- and ice-melting system
controls installed.Does Not
Not Observable
Not icable
plies
Add itional Comments/Assum ptions:
t (Tier L)H Medium (Tier 2)(Tier 3)Low
Project Title: Altonaga Residence
Data filename:
Report date: 08/03/23
Page 4 of10
402.1.1,
402.3.4
IFR1]1
*
Door U-factor U-U-
Does Not
Not Observable
see the Envelope Assemblies
table for values.
plies
icable
402.L.L,
402.3.1,
402.3.3,
402.5
lFR2llt
Glazing U-factor (area-weighted
average).
U-U.Complies
Does Not
Not Observable
see fhe Envelope Assemblies
table for values.
Applicable
303.1.3
lFR4l1
*
U-factors of fenestration products
are determined in accordance
with the NFRC test procedure or
taken from the default table.Observable
Applicable
Not
402.4.t.t
lFR23l1
s
Air barrier and thermal barrier
installed per manufacturer's
instructions.
Not
Observable
Applicable
402,4.3
IFR20]r
*
iFenestration that is not site built
iis listed and labeled as meeting
: AAMA /WDMA/CSA tot t1.5.2 I 4440
ior has infiltration rates per NFRC
i¿oo ttrat do not exceed-code
ilimits.
Not
Observable
Applicable
lC-rated recessed lighting fixtures
sealed at housing/interior finish
and labeled to indicate s2.0 cfm
leakage at 75 Pa,
e
res
Does Not
Observable
Supply and return ducts in attics
insulated >= R-8 where duct is
>= 3 inches in diameter and >=
R-6 where < 3 inches. Supply and
return ducts in other portions of
the building insulated >= R-6 for
diameter >= 3 inches and R-4.2
for < 3 inches in diameter.
403.3.1
lFR12¡1s Does Not
Not Observable
Not Applicable
les
403.3.2
lFR13ll
'*
Ducts, air handlers and filter
boxes are sealed with
ints/seams compliant with
lnternational Mechanical Code or
lnternational Residential Code, as
applicable.
Complies
Does Not
Not Observable
Not Applicable
Building cavities are not used as
ducts or plenums.IFR15¡3
*¡
EDoes Not
INot Observable
plies
1 (Tier 1)H Medium (Tier 2)(Tier 3)Low
Project Title: Altonaga Residence
Data filename:
Report date: OBlO3l23
Page 5 ofL0
Ducts declared to be with¡n the
cond¡tioned space are either 1)
completely within the continuous
a¡r barrier and w¡thin the building
thermal envelope, 2) buried
wlthin ceiling insulation in
accordance with Sectlon
R403.3.6 and the air handler ls
located completely within the
continuous air barrier and within
the building thermal envelope
and the duct leakage is <= L.5
cfm / 100 square feet of
conditioned floor area served by
the duct system, or 3) the ceiling
insulation R-value installed
against and above the insulated
duct >= to the proposed ceiling
insulation R-value, less the R-
value of the insulation on the
ot Applicable
Observaþle
Complíes
Does Not
HVAC piping conveying fluids
above 105 sF or chilled fluids
R-R-
below 55 sF are insulated to >R-
3.Observable
Applicable
lies
Not
403.4.1
lFR24l1
*
Protection of insulation on HVAC
piping.Does Not
Not Observable
Not ble
Does Not
Not Observaþle
Not Applicable
R-R.Hot water pipes are insulated to
>R-3.
Automatic or gravity dampers are
installed on all outdoor air
intakes and exhausts.
Does Not
Not Observable
Not Applicable
plies
Additional Comments/Assumptions:
H1 (Tier 3)Low(Tier 1)Medium lmpact (Tier 2)
Project Title: Altonaga Residence
Data filename:
Report date: 08/03/23
Page 6 ofL0
All installed insulation is labeled
or the installed R-values
provided.
EComplies
EDoes Not
DNot Observable
[ruot Rpplicabte
402.1.1,
402,2.5,
402,2.6
ltN3ll
r¡
Wall insulation R-value. lf this is a
mass wall w¡th at least % of the
wall insulation on the wall
exterior, the exterior insulation
requirement applies (FR10).
Wood
Mass
Steel
if-lNot
iLlNott
t
R.
trn
R-
Etrn
Wood
Mass
Steel
iEooes ¡tot
plies
Obseruable
Applicable
see the Envelope Assemblies
table for values.
Wall insulation is installed per
manufacturer's ínstructions.l1
303.2
Not Applicable
Observable
Not
Addltlonal Comments/Assumptlons:, .,
L (Tier 1)h Medium (Tier Low 3)
Project Title: Altonaga Residence
Data filename:
Report date: Ogl03l23
Page 7 of10
Sect¡on
#
& Req.lD
Final lnspect¡on Prov¡s¡ons Plans Verified
Value
Field Verified
Value Complies?CommentslAssumpt¡ons
402.1.1,
402.2.'J.,
402.2.2,
402.2.6
lFtllr
LlDoes Not
lNr.rt Oliservable
ENot Applicable
lSee the Envelope AssembliesCeiling insulation R-value.iDcomplies
âble for valuês.
R-
I Steel
I Wood
I Stecl
,R-
ìn Wood
Ceiling insulation installed per
tnanufacturer''s instructions.
Blown insulation marked every
300 ftr.
u Does
303.1.1.1, ,
'ENot Observable
ENot Applicable
303.2
IFt2l1
lies
Not
Vented attics with air permeable ,
insulation include baffle adjacent i
to soffit and eave vents that
extends over insulat¡on.
Complies
Does Not
Not Observable
Not Applicable
lFl22l'
.2.3
R-R-
Not
:INot
LlNot
Observable
Applicable
access hatch and door res402.2.4
lFt3l1 insulation >R-value of the
adjacent assembly.
ACH 50 =
rEoo es Not
lENot
tEruot
0bservable
Applicable
lies402.4.1.2
IFt17]1
:Blower door test @ 50 Pa. <=5 i ACH 50 =
ach in Climate Zones 1-2, and
<:3 ach in Climate Zones 3-8.
; Ducts are pressure tested to
:determine air leakage with
;either: Rough-in test: Total:leakage measured with a
pressure differential of 0.L inch
;w.9. across the system including
:the manufacturer's air handler
;enclosure if installed at time of
: test. Postconstruction test: Total
;leakage measured with a
pressure differential of 0.1" inch
:w.9. across the entire system
cfm/L00cfm/l-00T ftz-
including thc manufacturcr's air
handler encfosure.
lies403.3.3
lEt2711 EDoes Not
ENot Observable
ENot Applicable
,Duct t¡ghtness test result of <=4
¡cfm/100 ft2 across the system or
r<=3 cfm/100 ft2 without air
:handler @ 25 Pa, For rough-in
tests, verification may need to
Does Not
Not Observable
Not Applicable
cfm/100 cfm/l00Eã-ft2
'trItr
, occur du lnspection
403.3.4
lFt4lt
Air handler leakage designated
by manufacturer at <=2o/o of
design air flow.
IComplies
EDoes Not
'ENot Observable
Eruot Applicable
403.3.2.r.
lFt241t
, Programmable thermostats
installed for control of primary
:heating and cooling systems and
iinitially set by manufacturer to
:code specifications.
.1.
12
1
tFl9
Complies
Not Applicable
EDoes Not
ENot Observable
,DComplies
EDoes Not
ElNot Observable
Applicable
403.1.2
[fl1012
;Heat pump thermostat installed'on heat pumps.
'Circulatlng service hot water
systems have automatic or
, accessible manual controls,
Complles
Does Not
Not Observable
Not Appllcable
lFt1lì2
.5.1
,n
L H¡(Tier 3)2 Medium lmpact (Tier 2)3(Tier 1)Low
Project Title: Altonaga Residence
Data filename:
Report date: Ogl03l23
Page 8 of1-0
Section
#
& Req.lD
Final lnspection Provisions Plans Verified
Value
Field Verlfied
Value Complies?Comments/Assumptions
All mechanical ventilation system '
fans not part of tested and listed
'HVAC equipment meet efficacy
,,and airflow limits perTable
R403.6.1.
'EComplies
'DDoes Not
ENot Observable;ENot Applicable
403.6.1
IFl2s]2
Hot water boilers supplying heat
'through one- or two-p¡pe heating
systems have outdoor setback
control to lower boiler water
temperature based on outdoor
temperature,
iEcomplies
,ÜDoes Not
,!Not Observable
,INot Applicable
403.2
IFt2612
Heated water circulation systems'have a circulation pump. The ,
,system return pipe is a ded¡cated
return pipe or a cold water supply
,pipe. Gravity and thermos-
syphon circulation systems are
,not present. Controls for
circulating hot water system
'pumps start the pump with signal
for hot water demand within the
occupancy. Controls
automatically turn off the pump
when water is in circulation loop :
is at set-point temperature and :
, no demand for hot water exists.
403.5.1.1
lFt2812
EComplies'DDoes Not
!Not Observable
ENot Applicable
Electric heat trace systems
comply with IEEE 515.L or UL
515. Controls automatically
,adjust the energy input to the
heat tracing to maintain the
rdesired water temperature in the
'piplng.
'flComplies
EDoes Not
,INot Observable
[1Not npplicable
403.5,1,2
lFt2912
Demand recirculation water
systems have controls that
manage operation of the pump
and limit the temperature of the
rwater entering the cold water
EComplies
[Does Not
üNot Observable
ENot Applicable
to <= 104eF
403.5,2
lFl3o12
Drain water heat recovery units'tested in accordance with CSA
855.1. Potaþle water-side
pressure loss of drain water heat
recovery units < 3 psi for
'individual units connected to one '
or two showers. Potable water-
side pressure loss of drain water :
heat recovery units < 2 psi for
individual units connected to ..three or more showers,
lies403.5.4
IFt31]2 'flDoes Not
:ENot Observable
ENot Applicable
1.1
[Not Observable ;
DNot Applicable
EDoes Not
plies
plies
404.L
lFl6l1
.9Qo/o or more of permanent
,fixtures have high efficacy lamps.
. Fuel gas lighting systems have
.no continuous pilot light,lFt2313
a
'flDoes Not
'INot observable
'ENot Applicable
DComplies
.IDoes Not
INot Observable
ÜNot Applicable
Compliance certificate posted401.3
[Ft712
1 High lmpact (Tier 1)2 Medium ct (Tier 2)3 Low lm (Tier 3)
Project Title: Altonaga Residence
Data filename:
Report date: 08/03123
Page 9 of10
Manufacturer manuals for
mechanical and water heating
systems have been provided,Not Observoble
Not Applicable
Not
Additional Comments/Assum pt¡ons:
1 (Tier 1)H Medium (Tier 2)(Tier 3)Low
Pro¡ect Title: Altonoga Residcnce
Data filename:
Report date: o8lo3l23
Page L0 oft0
2018 IECC Energy
Efficiency Certifi cate
Above-Grade Walf
Below-Grade Wall
Floor
Ceiling / Roof
Ductwork (unconditioned spaces):
Window
Door
Heating System:
Cooling System
Water
Name:
Comments
2r.oo
29.00
o.oo
49.OO
o.28
o.32
Date:
R-Valuelnsulation Rating
Glass & Door Rating U-Factor SHG€
Heating & Cooling Equipment Eff ic iency