Onsite Wastewater Treatment System (OWTS) Installation Observations
1561 Panorama Drive
Garfield County, Colorado
Permit # SEPT-6913
Tom,
CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) on December 21,
2021 for the subject property. Tonka Excavation installed the system.
The OWTS design is based on 4-bedrooms. An average daily wastewater flow of 525 GPD was used.
The system installation included a 1500-gallon, two-compartment poly Infiltrator® septic tank with an
Orenco® Biotube Effluent Filter on the outlet tee followed by a 500-gallon, single-compartment poly
Infiltrator® pump chamber with an Orenco® Biotube Pump Vault and an Orenco® PF3005 pump. There
are filters on the outlet side of the primary septic tank and in the pump chamber. These must be
cleaned annually, or as needed. The floats were set to dose approximately 80 gallons each pump cycle.
Valley Precast out of Buena Vista performed start-up of the pumping system.
Effluent is pumped through a 1.5-inch diameter pump line from the pump chamber an Orenco® automatic
distributing valve (ADV), model 6402. The ADV was placed at a high point in an insulated riser with access
from grade.
Effluent is pressure dosed through 1.5-inch diameter distribution pipes to two beds, each with two rows of
11 ‘ADS’ ARC 36 chambers, for a total of 44 chambers and 660 square feet of infiltrative area. There
was at least 6-feet of undisturbed soil between each bed. Effluent is pressure dosed to two 1.5-inch
diameter level manifolds and 1.5-inch diameter laterals, which were hung with zip ties from the underside
of the chambers. Laterals have 5/32-inch diameter orifices facing up, with the exception of the first
and last holes facing down for drainage. Orifices were drilled 3-feet on center. Each lateral ends in a 90
degree ell facing up with a ball valve for flushing. Valves may be placed in a valve box, accessible from
grade, for access. Inspection ports must be placed at each corner of each bed. Ports may be cut to
grade and covered with a valve box for access.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS
in the future. Any additional OWTS construction must be according to the county regulations.
LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent on the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
CBO Inc.
Carla Ostberg, MPH, REHS
View of sewer line out of house, clean out, and primary septic tank
Inlet tee Effluent filter
Outlet tee with effluent filter External splice box on pump chamber
Pumping system in pump chamber Pump line from pump chamber to ADV
1.5 inch diameter pump line Chamber bed
ADV Chamber bed
Chamber beds and ADV
View of chamber bed looking toward house
Garfield Coui'zty
Public Health
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945-6614 ext. 8150
Permit Number SEPT-6913
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date 07 01 2021 Expiration Date 07/01/2022
For inspections, call: 970-945-6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: TBD Basalt Mtn Dr, Carbondale, CO 81623 Parcel No.: 239116201016
Owner Name: Thomas Fisher/Colleen Hause Owner Phone: (970) 309-0814
Designed By: CBO Septic Consulting, Inc. Designer Phone: (970) 309-5259
Number of Bedrooms: 4 Minimum Tank Capacity: 1 250-gallon Minimum Absorption: 613 ft'
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO Septic Consulting, Inc. dated May 31, 2021. Changes to the design and permit
must be approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new four -bedroom residence. The system will consist of a new, two -
compartment 1,500-gallon septic tank set level with access to grade followed by a 500-gallon single -
chamber pump chamber set level with access to grade and a high -head pump in the pump chamber.
Effluent will be pumped to an automatic distributing valve set at the high point of the system that
will distribute effluent to 624 ftz of STA. The new STA will consist of two gravel less chamber beds,
each bed consisting of two rows of chambers with 13 chambers per trench (52 chambers total).
Distribution laterals are to be 1 % inch Schedule 40 PVC, with 5/32-inch orifices 3-feet on center and
the laterals ending in flushing valves at the distal end of the laterals. Laterals are to be hung from the
underside of the chambers with zip -ties. The orifices are to be facing upward, except for the first and
last orifice (which shall face downward for drainage purposes). Inspection ports are to be installed at
each corner of each bed. Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 4S hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as -built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
4"",/ ! e_ P E 07/01/2021
Issued By: Garfield County Environmental Health Date
Department
01/03/2023
To Whom It May Concern:
We have been to the following site(s):
1561 Panorama Dr, Carbondale, Garfield County
We have verified that the system was started properly. The System went through several
cycles with no issues.
Sincerely,
Scott McIntosh
Service Manager
832‐R‐13‐002