HomeMy WebLinkAboutPermit
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945‐6614 ext. 8150
For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 591 County Road 259, Rifle, CO 81650
Parcel No.: _212733101003
Owner Name: Wences Gonzalez Owner Phone: (970) 319‐9287
Designed By: K‐Cronk Engineering Designer Phone: (970) 250‐0572
Number of Bedrooms: 4 Minimum Tank Capacity: 1,250‐gallon Minimum Absorption: 840 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT‐8239______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _08/25/2023____________________ Expiration Date_08/25/2024_________________
Permit Conditions:
Permit Conditions: This OWTS Permit is approved on the condition of compliance with the redesign
as submitted by K‐Cronk Engineering on August 24, 2023. Changes must be approved by Garfield
County Public Health and the designer prior to construction.
The new OWTS will serve a new 4‐bedroom residence but was designed for a 4‐bedroom residence.
The system will consist of a new, two‐compartment 1,500‐gallon septic tank set level with access to
grade and a high‐head pump that will distribute effluent to 864 ft2 of STA. The new STA will consist
of 4 gravelless chamber trenches consisting of 18 Quick4 chambers per trench, for a total of 72
Quick4 chambers. The pump line will be constructed of 2” diameter Schedule 40 PVC. Distribution
laterals will consist of 1” diameter Schedule 40 PVC and shall have 5/32” diameter orifice holes
spaced every 4’ on‐center (O.C) facing up. Distribution laterals shall be hung on the underside of the
chambers using zip ties and shall end in a 90‐degree bend with a cap to allow flushing of the laterals.
Inspection ports are to be installed at each end of each trench. Maintain all setbacks and elevations
as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILED
WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as‐built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
08/25/2023
Issued By: Garfield County Environmental Health
Department
Date