Loading...
HomeMy WebLinkAboutComponent Specifications - Revised 08.15.2023Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1 Rev. 1.2, © 08/14 Page 1 of 4 Biotube® ProPak Pump Package™ Technical Data SheetOrenco® 60-Hz Series Pump Packages General Orenco’s Biotube® ProPak™ is a complete, integrated pump package for filtering and pumping effluent from septic tanks. And its patented pump vault technology eliminates the need for separate dosing tanks. This document provides detailed information on the ProPak pump vault and filter, 4-in. (100-mm) 60-Hz turbine effluent pump, and control panel. For more information on other ProPak components, see the following Orenco technical documents: • Float Switch Assemblies (NSU-MF-MF-1) • Discharge Assemblies (NTD-HV-HV-1) • Splice Boxes (NTD-SB-SB-1) • External Splice Box (NTD-SB-SB-1) Applications The Biotube ProPak is designed to filter and pump effluent to either gravity or pressurized discharge points. It is intended for use in a septic tank (one- or two-compartment) and can also be used in a pump tank. The Biotube ProPak is designed to allow the effluent filter to be removed for cleaning without the need to remove the pump vault or pump, simpli- fying servicing. Complete packages are available for on-demand or timed dosing sys- tems with flow rates of 20, 30, and 50-gpm (1.3, 1.9, and 3.2 L/sec), as well as with 50 Hz and 60 Hz power supplies. Standard Models BPP20DD, BPP20DD-SX, BPP30TDA, BPP30TDD-SX, BBPP50TDA, BPP50TDD-SX Product Code Diagram Biotube® ProPak™ pump package components. 4-in. (100-mm) turbine effluent pump Pump motor Pump liquid end Pump vault Support pipe Discharge assembly Float collar Float stem Floats Float bracket Biotube® filter cartridge Vault inlet holes External splice box (Optional; internal splice box comes standard.) Riser lid (not included) Riser (not included) Control panel BPP Pump flow rate, nominal: 20 = 20 gpm (1.3 L/sec) 30 = 30 gpm (1.9 L/sec) 50 = 50 gpm (3.2 L/sec) Control panel application: DD = demand-dosing TDA = timed-dosing, analog timer TDD = timed dosing, digital timer, elapsed time meter & counters Standard options: Blank = 57-in. (1448-mm) vault height, internal splice box, standard discharge assembly 68 = 68-in. (1727-mm) vault height SX = external splice box CW = cold weather discharge assembly DB = drainback discharge assembly Q = cam lock MFV = non-mercury float - Biotube® ProPak™ pump vault Technical Data SheetOrenco® Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1 Rev. 1.2, © 08/14 Page 2 of 4 ProPak™ Pump Vault Materials of Construction Vault body Polyethylene Support pipes PVC Dimensions, in. (mm) A - Overall vault height 57 (1448) or 68 (1727) B - Vault diameter 17.3 (439) C - Inlet hole height 19 (475) D - Inlet hole diameter (eight holes total) 2 (50) E - Vault top to support pipe bracket base 3 (76) F - Vault bottom to filter cartridge base 4 (102) ProPak™ pump vault (shown with Biotube filter and effluent pump) Biotube® Filter Cartridge Materials of Construction Filter tubes Polyethylene Cartridge end plates Polyurethane Handle assembly PVC Dimensions, in. (mm) A - Cartridge height 18 (457) B - Cartridge width 12 (305) Performance Biotube® mesh opening 0.125 in. (3 mm)* Total filter flow area 4.4 ft2 (0.4 m2) Total filter surface area 14.5 ft2 (1.35 m2) Maximum flow rate 140 gpm (8.8 L/sec) *0.062-in. (1.6-mm) filter mesh available Biotube® filter cartridge (shown with float switch assembly) AA D E B B C E Technical Data Sheet Orenco® Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1 Rev. 1.2, © 08/14 Page 3 of 4 Pump Curves Pump curves, such as those shown here, can help you determine the best pump for your system. Pump curves show the relationship between flow (gpm or L/sec) and pressure (TDH), providing a graphical representation of a pump’s performance range. Pumps perform best at their nominal flow rate, measured in gpm or L/sec. 4-in. (100-mm) Turbine Effluent Pumps Orenco’s 4-in. (100 mm) Turbine Effluent Pumps are constructed of lightweight, corrosion-resistant stainless steel and engineered plastics; all are field-serviceable and repairable with common tools. All 60-Hz PF Series models are CSA certified to the U.S. and Canadian safety standards for effluent pumps, and meet UL requirements. Power cords for Orenco’s 4-in. (100-mm) turbine effluent pumps are Type SOOW 600-V motor cable (suitable for Class 1, Division 1 and 2 applications). Materials of Construction Discharge: Stainless steel or glass-filled polypropylene Discharge bearing: Engineered thermoplastic (PEEK) Diffusers: Glass-filled PPO Impellers: Acetal (20-, 30-gmp), Noryl (50-gpm) Intake screens: Polypropylene Suction connection: Stainless steel Drive shaft: 300 series stainless steel Coupling: Sintered 300 series stainless steel Shell: 300 series stainless steel Lubricant: Deionized water and propylene glycol Specifications Nom. flow, Length Weight Discharge Impellers gpm (L/sec) in. (mm) lb (kg) in., nominal 1 20 (1.3) 22.5 (572) 26 (11) 1.25 4 30 (1.9) 21.3 (541) 25 (11) 1.25 3 50 (3.2) 20.3 (516) 27 (12) 2.00 2 Performance Nom. flow, hp (kW) Design Rated Min liquid gpm (L/sec) flow amps cycles/day level, in. (mm) 2 20 (1.3) 0.5 (0.37) 12.3 300 18 (457) 30 (1.9) 0.5 (0.37) 11.8 300 20 (508) 50 (3.2) 0.5 (0.37) 12.1 300 24 (610) 1 Discharge is female NPT threaded, U.S. nominal size, to accommodate Orenco® discharge hose and valve assemblies. Consult your Orenco Distributor about fittings to connect discharge assemblies to metric-sized piping. 2 Minimum liquid level is for single pumps when installed in an Orenco Biotube® ProPak™ Pump Vault. 10 20 30 40 6050 70 0.63 1.26 1.89 2.52 3.793.15 4.42 140 120 100 80 60 40 20 Flow in gallons per minute (gpm) Flow in liters per second (L/sec) To ta l d y n a m i c h e a d ( T D H ) i n f e e t To ta l d y n a m i c h e a d ( T D H ) i n m e t e r s PF 500511 43 37 30 24 18 12 6 PF 200511 PF 300511 Technical Data SheetOrenco® Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-BPP-1 Rev. 1.2, © 08/14 Page 4 of 4 AUTO OFF MAN NN1 Control Panel (Demand Dose) Orenco’s ProPak™ demand dose control panels are specifically engineered for the ProPak pump package and are ideal for applications such as demand dosing from a septic tank into a conventional gravity drainfield. Materials of Construction Enclosure UV-resistant fiberglass, UL Type 4X Hinges Stainless steel Dimensions, in. (mm) A - Height 11.5 (290) B - Width 9.5 (240) C - Depth 5.4 (135) Specifications Panel ratings 120 V, 3/4 hp (0.56 kW), 14 A, single phase, 60 Hz 1. Motor-start contactor 16 FLA, 1 hp (0.75 kW), 60 Hz; 2.5 million cycles at FLA (10 million at 50% of FLA) 2. Circuit 120 V, 10 A, OFF/ON switch, Single pole breakers 3. Toggle switch Single-pole, double-throw HOA switch, 20 A 4. Audio alarm 95 dB at 24 in. (600 mm), warble-tone sound, UL Type 4X 5. Audio alarm 120 V, automatic reset, DIN rail mount silence relay 6. Visual alarm 7/8-in. (22-mm) diameter red lens, “Push-to-silence,” 120 V LED, UL Type 4X Control Panel (Timed Dose) Orenco’s ProPak timed dose control panels are specifically engineered for the ProPak pump package and are ideal for applications such as timed dosing from a septic tank into a pressurized drainfield or mound. Analog or digital timers are available. Materials of Construction Enclosure UV-resistant fiberglass, UL Type 4X Hinges Stainless steel Dimensions, in. (mm) A - Height 11.5 (290) B - Width 9.5 (240) C - Depth 5.4 (135) Specifications Panel ratings 120 V, 3/4 hp (0.56 kW), 14 A, single phase, 60 Hz Dual-mode Programmable for timed- or demand-dosing (digital timed-dosing panels only) 1a. Analog timer 120 V, repeat cycle from 0.05 seconds to 30 (not shown) hours. Separate variable controls for OFF and ON time periods 1b. Digital timer 120-V programmable logic unit with built-in LCD (shown below) screen and programming keys. Provides control functions and timing for panel operation 2. Motor-start contactor 16 FLA, 1 hp (0.75 kW), 60 Hz; 2.5 million cycles at FLA (10 million at 50% of FLA) 3. Circuit breakers 120 V, 10 A, OFF/ON switch. Single pole 120 V 4. Toggle Switch Single-pole, double-throw HOA switch, 20 A 5. Audio alarm 95 dB at 24 in. (600 mm), warble-tone sound, UL Type 4X 6. Visual alarm 7/8-in. (22-mm) diameter red lens, “Push-to-silence”, 120 V LED, UL Type 4X Control panel, demand-dose Control panel, timed-dose (digital timer model shown) 1b 2 3 4 56 1 2 3 4 5 6 Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1 Rev. 2.2, © 09/14 Page 1 of 6 PF Series 4-inch (100-mm) Submersible Effluent Pumps Technical Data SheetOrenco® Applications Our 4-inch (100-mm) Submersible Effluent Pumps are designed to transport screened effluent (with low TSS counts) from septic tanks or separate dosing tanks. All our pumps are constructed of lightweight, corrosion-resistant stainless steel and engineered plastics; all are field- serviceable and repairable with common tools; and all 60-Hz PF Series models are CSA certified to the U.S. and Canadian safety standards for effluent pumps, meeting UL requirements. Orenco’s Effluent Pumps are used in a variety of applications, including pressurized drainfields, packed bed filters, mounds, aerobic units, effluent irrigation, effluent sewers, wetlands, lagoons, and more. These pumps are designed to be used with a Biotube® pump vault or after a secondary treatment system. Features/Specifications To specify this pump for your installation, require the following: • Minimum 24-hour run-dry capability with no deterioration in pump life or performance* • Patented 1⁄8-inch (3-mm) bypass orifice to ensure flow recirculation for motor cooling and to prevent air bind • Liquid end repair kits available for better long-term cost of ownership • TRI-SEAL™ floating impeller design on 10, 15, 20, and 30 gpm (0.6, 1.0, 1.3, and 1.9 L/sec) models; floating stack design on 50 and 75 gpm (3.2 and 4.7 L/sec) models • Franklin Electric Super Stainless motor, rated for continuous use and frequent cycling • Type SOOW 600-V motor cable • Five-year warranty on pump or retrofit liquid end from date of manu- facture against defects in materials or workmanship * Not applicable for 5-hp (3.73 kW) models Standard Models See specifications chart, pages 2-3, for a list of standard pumps. For a complete list of available pumps, call Orenco. Product Code Diagram PF - Nominal flow, gpm (L/sec): 10 = 10 (0.6) 15 = 15 (1.0) 20 = 20 (1.3) 30 = 30 (1.9) 50 = 50 (3.2) 75 = 75 (4.7) Pump, PF Series Frequency: 1 = single-phase 60 Hz 3 = three-phase 60 Hz 5 = single-phase 50 Hz Voltage, nameplate: 1 = 115* 200 = 200 2 = 230† 4 = 460 Horsepower (kW): 03 = 1⁄3 hp (0.25) 05 = ½ hp (0.37) 07 = ¾ hp (0.56) 10 = 1 hp (0.75) 15 = 1-½ hp (1.11) 20 = 2 hp (1.50) 30 = 3 hp (2.24) 50 = 5 hp (3.73) Cord length, ft (m):‡ Blank = 10 (3) 20 = 20 (6) 30 = 30 (9) 50 = 50 (15) * ½-hp (0.37kW) only †220 volts for 50 Hz pumps ‡Note: 20-foot cords are available only for single-phase pumps through 1-½ hp Franklin Super Stainless Motor Franklin Liquid End Discharge Connection Bypass Orifice Suction Connection LR80980 LR2053896 Powered by Technical Data SheetOrenco® Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1 Rev. 2.2, © 09/14 Page 2 of 6 Specifications, 60 Hz Pump Model PF100511 10 (0.6) 0.50 (0.37) 1 115 120 12.7 12.7 6 1 ¼ in. GFP 23.0 (660) 16 (406) 26 (12) 300 PF100512 10 (0.6) 0.50 (0.37) 1 230 240 6.3 6.3 6 1 ¼ in. GFP 23.0 (660) 16 (406) 26 (12) 300 PF10053200 10 (0.6) 0.50 (0.37) 3 200 208 3.8 3.8 6 1 ¼ in. GFP 23.0 (660) 16 (406) 26 (12) 300 PF100712 4, 5 10 (0.6) 0.75 (0.56) 1 230 240 8.3 8.3 8 1 ¼ in. GFP 25.9 (658) 17 (432) 30 (14) 300 PF10073200 4, 5 10 (0.6) 0.75 (0.56) 3 200 208 5.1 5.2 8 1 ¼ in. GFP 25.4 (645) 17 (432) 31 (14) 300 PF101012 5, 6 10 (0.6) 1.00 (0.75) 1 230 240 9.6 9.6 9 1 ¼ in. GFP 27.9 (709) 18 (457) 33 (15) 100 PF10103200 5, 6 10 (0.6) 1.00 (0.75) 3 200 208 5.5 5.5 9 1 ¼ in. GFP 27.3 (693) 18 (457) 37 (17) 300 PF102012 5, 6, 7, 8 10 (0.6) 2.00 (1.49) 1 230 240 12.1 12.1 18 1 ¼ in. SS 39.5 (1003) 22 (559) 48 (22) 100 PF102032 5, 6, 8 10 (0.6) 2.00 (1.49) 3 230 240 7.5 7.6 18 1 ¼ in. SS 37.9 (963) 20 (508) 44 (20) 300 PF10203200 5, 6, 8 10 (0.6) 2.00 (1.49) 3 200 208 8.7 8.7 18 1 ¼ in. SS 37.9 (963) 20 (508) 44 (20) 300 PF150311 15 (1.0) 0.33 (0.25) 1 115 120 8.7 8.8 3 1 ¼ in. GFP 19.5 (495) 15 (380) 23 (10) 300 PF150312 15 (1.0) 0.33 (0.25) 1 230 240 4.4 4.5 3 1 ¼ in. GFP 19.5 (495) 15 (380) 23 (10) 300 PF200511 20 (1.3) 0.50 (0.37) 1 115 120 12.3 12.5 4 1 ¼ in. GFP 22.3 (566) 18 (457) 25 (11) 300 PF200512 20 (1.3) 0.50 (0.37) 1 230 240 6.4 6.5 4 1 ¼ in. GFP 22.5 (572) 18 (457) 26 (12) 300 PF20053200 20 (1.3) 0.50 (0.37) 3 200 208 3.7 3.8 4 1 ¼ in. GFP 22.3 (566) 18 (457) 26 (12) 300 PF201012 4, 5 20 (1.3) 1.00 (0.75) 1 230 240 10.5 10.5 7 1 ¼ in. GFP 28.4 (721) 20 (508) 33 (15) 100 PF20103200 4, 5 20 (1.3) 1.00 (0.75) 3 200 208 5.8 5.9 7 1 ¼ in. GFP 27.8 (706) 20 (508) 33 (15) 300 PF201512 4, 5 20 (1.3) 1.50 (1.11) 1 230 240 12.4 12.6 9 1 ¼ in. GFP 34.0 (864) 24 (610) 41 (19) 100 PF20153200 4, 5 20 (1.3) 1.50 (1.11) 3 200 208 7.1 7.2 9 1 ¼ in. GFP 30.7 (780) 20 (508) 35 (16) 300 PF300511 30 (1.9) 0.50 (0.37) 1 115 120 11.8 11.8 3 1 ¼ in. GFP 21.3 (541) 20 (508) 28 (13) 300 PF300512 30 (1.9) 0.50 (0.37) 1 230 240 6.2 6.2 3 1 ¼ in. GFP 21.3 (541) 20 (508) 25 (11) 300 PF30053200 30 (1.9) 0.50 (0.37) 3 200 208 3.6 3.6 3 1 ¼ in. GFP 21.3 (541) 20 (508) 25 (11) 300 PF300712 30 (1.9) 0.75 (0.56) 1 230 240 8.5 8.5 5 1 ¼ in. GFP 24.8 (630) 21 (533) 29 (13) 300 PF30073200 30 (1.9) 0.75 (0.56) 3 200 208 4.9 4.9 5 1 ¼ in. GFP 24.6 (625) 21 (533) 30 (14) 300 PF301012 4 30 (1.9) 1.00 (0.75) 1 230 240 10.4 10.4 6 1 ¼ in. GFP 27.0 (686) 22 (559) 32 (15) 100 PF30103200 4 30 (1.9) 1.00 (0.75) 3 200 208 5.8 5.8 6 1 ¼ in. GFP 26.4 (671) 22 (559) 33 (15) 300 PF301512 4, 5 30 (1.9) 1.50 (1.11) 1 230 240 12.6 12.6 8 1 ¼ in. GFP 32.8 (833) 24 (610) 40 (18) 100 PF30153200 4, 5 30 (1.9) 1.50 (1.11) 3 200 208 6.9 6.9 8 1 ¼ in. GFP 29.8 (757) 22 (559) 34 (15) 300 PF301534 4, 5 30 (1.9) 1.50 (1.11) 3 460 480 2.8 2.8 8 1 ¼ in. GFP 29.5 (685) 22 (559) 34 (15) 300 PF302012 5, 6, 7 30 (1.9) 2.00 (1.49) 1 230 240 11.0 11.0 10 1 ¼ in. SS 35.5 (902) 26 (660) 44 (20) 100 PF30203200 5, 6 30 (1.9) 2.00 (1.49) 3 200 208 9.3 9.3 10 1 ¼ in. SS 34.0 (864) 24 (610) 41 (19) 300 PF303012 5, 6, 7, 8 30 (1.9) 3.00 (2.23) 1 230 240 16.8 16.8 14 1 ¼ in. SS 44.5 (1130) 33 (838) 54 (24) 100 PF303032 5, 6, 8 30 (1.9) 3.00 (2.23) 3 230 240 10.0 10.1 14 1 ¼ in. SS 44.3 (1125) 27 (686) 52 (24) 300 PF305012 5, 6, 7, 8 30 (1.9) 5.00 (3.73) 1 230 240 25.6 25.8 23 1 ¼ in. SS 66.5 (1689) 53 (1346) 82 (37) 100 PF305032 5, 6, 8 30 (1.9) 5.00 (3.73) 3 230 240 16.6 16.6 23 1 ¼ in. SS 60.8 (1544) 48 (1219) 66 (30) 300 PF30503200 5, 6, 8 30 (1.9) 5.00 (3.73) 3 200 208 18.7 18.7 23 1 ¼ in. SS 60.8 (1544) 48 (1219) 66 (30) 300 PF500511 50 (3.2) 0.50 (0.37) 1 115 120 12.1 12.1 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300 PF500512 50 (3.2) 0.50 (0.37) 1 230 240 6.2 6.2 2 2 in. SS 20.3 (516) 24 (610) 27 (12) 300 PF500532 50 (3.2) 0.50 (0.37) 3 230 240 3.0 3.0 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300 PF50053200 50 (3.2) 0.50 (0.37) 3 200 208 3.7 3.7 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300 PF500534 50 (3.2) 0.50 (0.37) 3 460 480 1.5 1.5 2 2 in. SS 20.3 (516) 24 (610) 28 (13) 300 PF500712 50 (3.2) 0.75 (0.56) 1 230 240 8.5 8.5 3 2 in. SS 23.7 (602) 25 (635) 31 (14) 300 PF500732 50 (3.2) 0.75 (0.56) 3 230 240 3.9 3.9 3 2 in. SS 23.7 (602) 25 (635) 32 (15) 300 PF50073200 50 (3.2) 0.75 (0.56) 3 200 208 4.9 4.9 3 2 in. SS 23.1 (587) 26 (660) 32 (15) 300 De s i g n g p m (L / s e c ) Ho r s e p o w e r (k W ) Ph a s e Na m e p l a t e vo l t a g e Ac t u a l v o l t a g e De s i g n f l o w am p s Ma x a m p s Im p e l l e r s Di s c h a r g e s i z e an d m a t e r i a l 1 Le n g t h , i n . ( m m ) Mi n . l i q u i d l e v e l , 2 in . ( m m ) We i g h t , 3 l b ( k g ) Ra t e d c y c l e s / d a y Technical Data Sheet Orenco® Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1 Rev. 2.2, © 09/14 Page 3 of 6 Specifications, 60 Hz (continued) Pump Model PF500734 50 (3.2) 0.75 (0.56) 3 460 480 1.8 1.8 3 2 in. SS 34.8 (884) 25 (635) 31 (14) 300 PF501012 50 (3.2) 1.00 (0.75) 1 230 240 10.1 10.1 4 2 in. SS 27.0 (686) 26 (660) 35 (16) 100 PF50103200 50 (3.2) 1.00 (0.75) 3 200 208 5.7 5.7 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300 PF501034 50 (3.2) 1.00 (0.75) 3 460 480 2.2 2.2 4 2 in. SS 26.4 (671) 26 (660) 39 (18) 300 PF5015124 50 (3.2) 1.50 (1.11) 1 230 240 12.5 12.6 5 2 in. SS 32.5 (826) 30 (762) 41 (19) 100 PF501532004 50 (3.2) 1.50 (1.11) 3 200 208 7.0 7.0 5 2 in. SS 29.3 (744) 26 (660) 35 (16) 300 PF503012 4, 5, 7, 8 50 (3.2) 3.00 (2.23) 1 230 240 17.7 17.7 8 2 in. SS 43.0 (1092) 37 (940) 55 (25) 100 PF50303200 4, 5, 8 50 (3.2) 3.00 (2.23) 3 200 208 13.1 13.1 8 2 in. SS 43.4 (1102) 30 (762) 55 (25) 300 PF503034 4, 5, 8 50 (3.2) 3.00 (2.23) 3 460 480 5.3 5.3 8 2 in. SS 40.0 (1016) 31 (787) 55 (25) 300 PF505012 5,6,7,8 50 (3.2) 5.00 (3.73) 1 230 240 26.2 26.4 13 2 in. SS 65.4 (1661) 55 (1397) 64 (29) 300 PF505032 5,6,7,8 50 (3.2) 5.00 (3.73) 3 230 240 16.5 16.5 13 2 in. SS 59.3 (1506) 49 (1245) 64 (29) 300 PF751012 75 (4.7) 1.00 (0.75) 1 230 240 9.9 10.0 3 2 in. SS 27.0 (686) 27 (686) 34 (15) 100 PF751512 75 (4.7) 1.50 (1.11) 1 230 240 12.1 12.3 4 2 in. SS 33.4 (848) 30 (762) 44 (20) 100 Specifications, 50 Hz Pump Model PF100552 10 (0.6) 0.50 (0.37) 1 220 230 3.9 4.1 6 1 ¼ in. GFP 23.0 (584) 17 (432) 26 (12) 300 PF100752 4, 5 10 (0.6) 0.75 (0.56) 1 220 230 6.2 6.2 9 1 ¼ in. GFP 26.8 (658) 17 (432) 30 (14) 300 PF101552 5, 6 10 (0.6) 1.50 (1.11) 1 220 230 10.5 11.4 18 1 ¼ in. SS 39.5 (1003) 22 (559) 46 (21) 300 PF300552 30 (1.9) 0.50 (0.37) 1 220 230 4.1 4.1 4 1 ¼ in. GFP 22.5 (572) 19 (483) 26 (12) 300 PF300752 30 (1.9) 0.75 (0.56) 1 220 230 6.1 6.1 5 1 ¼ in. GFP 24.8 (630) 19 (483) 29 (13) 300 PF301052 30 (1.9) 1.00 (0.75) 1 220 230 7.4 7.4 7 1 ¼ in. GFP 28.4 (721) 20 (508) 32 (15) 100 PF301552 4, 5 30 (1.9) 1.50 (1.11) 1 220 230 9.3 9.3 8 1 ¼ in. GFP 35.4 (899) 24 (610) 40 (18) 100 PF500552 50 (3.2) 0.50 (0.37) 1 220 230 4.0 4.0 2 2 in. SS 20.3 (516) 25 (635) 29 (13) 300 PF500752 50 (3.2) 0.75 (0.56) 1 220 230 6.3 6.4 3 2 in. SS 23.7 (602) 25 (635) 31 (14) 300 PF501052 50 (3.2) 1.00 (0.75) 1 220 230 7.3 7.4 4 2 in. SS 27.0 (686) 26 (660) 35 (16) 100 PF501552 50 (3.2) 1.50 (1.11) 1 220 230 9.1 9.1 5 2 in. SS 32.5 (826) 30 (762) 42 (19) 100 PF751052 75 (3.2) 1.00 (0.75) 1 220 230 7.3 7.3 4 2 in. SS 30.0 (762) 27 (686) 34 (15) 100 1 GFP = glass-filled polypropylene; SS = stainless steel. The 1 ¼-in. NPT GFP discharge is 2 7⁄8 in. octagonal across flats; the 1 ¼-in. NPT SS discharge is 2 1⁄8 in. octagonal across flats; and the 2-in. NPT SS discharge is 2 7⁄8 in. hexagonal across flats. Discharge is female NPT threaded, U.S. nominal size, to accommodate Orenco® discharge hose and valve assemblies. Consult your Orenco Distributor about fittings to connect hose and valve assemblies to metric-sized piping. 2 Minimum liquid level is for single pumps when installed in an Orenco Biotube® Pump Vault or Universal Flow Inducer. In other applications, minimum liquid level should be top of pump. Consult Orenco for more information. 3 Weight includes carton and 10-ft (3-m) cord. 4 High-pressure discharge assembly required. 5 Do not use cam-lock option (Q) on discharge assembly. 6 Custom discharge assembly required for these pumps. Contact Orenco. 7 Capacitor pack (sold separately or installed in a custom control panel) required for this pump. Contact Orenco. 8 Torque locks are available for all pumps, and are supplied with 3-hp and 5-hp pumps. De s i g n g p m (L / s e c ) Ho r s e p o w e r (k W ) Ph a s e Na m e p l a t e vo l t a g e Ac t u a l v o l t a g e De s i g n f l o w am p s Ma x a m p s Im p e l l e r s Di s c h a r g e s i z e an d m a t e r i a l 1 Le n g t h , i n . ( m m ) Mi n . l i q u i d l e v e l , 2 in . ( m m ) We i g h t , 3 l b ( k g ) Ra t e d c y c l e s / d a y Technical Data SheetOrenco® Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1 Rev. 2.2, © 09/14 Page 4 of 6 Materials of Construction Discharge Glass-filled polypropylene or stainless steel Discharge bearing Engineered thermoplastic (PEEK) Diffusers Glass-filled PPO (Noryl GFN3) Impellers Celcon® acetal copolymer on 10-, 20, and 30-gpm models; 50-gpm impellers are Noryl GFN3 Intake screen Polypropylene Suction connection Stainless steel Drive shaft 7/16 inch hexagonal stainless steel, 300 series Coupling Sintered stainless steel, 300 series Shell Stainless steel, 300 series Motor Franklin motor exterior constructed of stainless steel. Motor filled with deionized water and propylene glycol for constant lubrication. Hermetically sealed motor housing ensures moisture-free windings. All thrust absorbed by Kingsbury-type thrust bearing. Rated for continuous duty. Single- phase motors and 200 and 230 V 3-phase motors equipped with surge arrestors for added security. Single-phase motors through 1.5 hp (1.11 kW) have built-in thermal overload protection, which trips at 203-221˚ F (95-105˚ C). Using a Pump Curve A pump curve helps you determine the best pump for your system. Pump curves show the relationship between flow (gpm or L/sec) and pressure (total dynamic head, or TDH), providing a graphical representation of a pump’s optimal performance range. Pumps perform best at their nominal flow rate — the value, measured in gpm, expressed by the first two numerals in an Orenco pump nomenclature. The graphs in this section show optimal pump operation ranges with a solid line. Flow flow rates outside of these ranges are shown with a dashed line. For the most accurate pump specification, use Orenco’s PumpSelect™ software. Pump Curves, 60 Hz Models Tot a l d y n a m i c h e a d ( T D H ) i n f e e t Flow in gallons per minute (gpm) 24 81012141660 800 700 600 500 400 300 200 100 PF1005-FC w/ ¼" flow controller PF10 Series, 60 Hz, 0.5 - 2.0 hp PF1007 PF1010 PF1020 PF1005 Tot a l d y n a m i c h e a d ( T D H ) i n f e e t Flow in gallons per minute (gpm) 36 12 15 18 21 2490 160 140 120 100 80 60 40 20 0 PF1503 PF15 Series, 60 Hz, 0.3 hp Technical Data Sheet Orenco® Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1 Rev. 2.2, © 09/14 Page 5 of 6 Tot a l d y n a m i c h e a d ( T D H ) i n f e e t Flow in gallons per minute (gpm) 5102025303540150 400 350 300 250 200 150 100 50 0 PF2005 PF2010 PF2015 PF20 Series, 60 Hz, 0.5 - 1.5 hp Tot a l d y n a m i c h e a d ( T D H ) i n f e e t Flow in gallons per minute (gpm) 510202530354045150 800 900 700 600 500 400 300 200 100 0 PF3005 PF3007 PF3010 PF3015 PF3020 PF3030 PF3050 PF30 Series, 60 Hz, 0.5 - 5.0 hp Tot a l d y n a m i c h e a d ( T D H ) i n f e e t Flow in gallons per minute (gpm) 450 400 350 300 250 200 150 100 50 0 10 02040506070809030 PF5050 PF5030 PF5015 PF5010 PF5007 PF5005 PF50 Series, 60 Hz, 0.5 - 5.0 hp Tot a l d y n a m i c h e a d ( T D H ) i n f e e t Flow in gallons per minute (gpm) 10 20 40 50 60 70 80 90 100300 80 90 100 70 60 50 40 30 20 10 0 PF75 Series, 60 Hz, 1.0 - 1.5 hpPF7515 PF7510 60 Hz Models (continued) Technical Data SheetOrenco® Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-PU-PF-1 Rev. 2.2, © 09/14 Page 6 of 6 To ta l d y n a m i c h e a d ( T D H ) i n m e t e r s To ta l d y n a m i c h e a d ( T D H ) i n f e e t , n o m i n a l Flow in liters per second (L/sec) Flow in gallons per minute (gpm), nominal 0.90.80.70.60.50.40.30.20.10 13119.57.96.34.83.21.6 120 100 80 60 40 20 0 160 180 140 394 328 262 197 131 66 525 459 PF100552 PF100752 PF101552 PF1005-FC w/ 6mm flow controller PF10 Series, 50 Hz, 0.37 - 1.11 kW To ta l d y n a m i c h e a d ( T D H ) i n m e t e r s To ta l d y n a m i c h e a d ( T D H ) i n f e e t , n o m i n a l Flow in liters per second (L/sec) Flow in gallons per minute (gpm), nominal 0.8 1.2 1.6 2.0 2.40.40 13 19 25 326.3 60 80 100 120 40 20 0 197 262 328 131 66 PF301552 PF301052 PF300752 PF300552 PF30 Series, 50 Hz, 0.37 - 1.11 kW Tot a l d y n a m i c h e a d ( T D H ) i n m e t e r s Tot a l d y n a m i c h e a d ( T D H ) i n f e e t , n o m i n a l Flow in liters per second (L/sec) Flow in gallons per minute (gpm), nominal 0.5 1.0 2.0 2.5 3.0 3.5 4.0 4.51.50 7.9 16 32 40 48 56 6324 40 45 35 30 25 20 15 10 5 0 131 115 98 82 66 49 33 16 PF501552 PF501052 PF500752 PF500552 PF50 Series, 50 Hz, 0.37 - 1.11 kW Tot a l d y n a m i c h e a d ( T D H ) i n m e t e r s Tot a l d y n a m i c h e a d ( T D H ) i n f e e t , n o m i n a l Flow in liters per second (L/sec) Flow in gallons per minute (gpm), nominal 0.6 1.2 2.4 3.0 3.6 4.2 5.44.8 6.01.80 10 19 4838 57 67 76 8629 27 30 24 21 18 15 12 9 6 3 0 89 79 69 59 49 39 30 20 PF751052 PF75 Series, 50 Hz, 0.75 kW Pump Curves, 50 Hz Models Orenco Systems® Inc. , 814 Airway Ave., Sutherlin, OR 97479 USA • 800-348-9843 • 541-459-4449 • www.orenco.com NTD-SF-OS-1 Rev. 1.1, © 09/14 Page 1 of 1 Orifice Shields Technical Data SheetOrenco® General Orenco Orifice Shields snap-fit onto laterals. They may be placed on top of or beneath a lateral, depending on the location of the orifice. Orifice shields are covered by method-of-use patent # 5,360,556. Standard Models OS075, OS100, OS125, OS150, OS200 Product Code Diagram Material of Construction PVC per ASTM D-1784 Physical Specifications Model Shield O.D. Lateral pipe O.D. in. (mm) in. (mm) OS075 3.5 (89) 1.05 (27) OS100 3.5 (89) 1.315 (33) OS125 3.5 (89) 1.66 (42) OS150 4.5 (114) 1.90 (48) OS200 4.5 (114) 2.375 (60) Applications Orenco® Orifice Shields are used in a pressurized distribution system to protect the orifices from backfill debris that might cause orifice blockage. Orifice shield installed on lateral pipe, standard configuration Shield Orifice Cutaway view, standard configuration Shield Orifice Cutaway view, cold weather configuration OS Lateral pipe size, nominal: 075 = 0.75 in. (20 mm) 100 = 1.00 in. (25 mm) 125 = 1.25 in. (32 mm) 150 = 1.50 in. (40 mm) 200 = 2.00 in. (50 mm) Orifice shield Item# SEK- Orenco® Flushing Assemblies Flushing Assemblies Orenco® flushing assemblies provide easy access for lateral maintenance. Flushing assembly kits include a PVC sweep with ball valve and a polyethylene valve box enclosure. Orenco® flushing assemblies are available in the following sizes: • 1” diameter • 1.25” diameter • 1.5” diameter • 2" diameter Valve Boxes Orenco® valve boxes are used to provide access to flushing assemblies. Constructed of polyethylene. Valve Box, 7-in. diameter round enclosure Note: Kits include VB7 valve box enclosure. (719) 395-6764 Fax: (719) 395-3727 28005 County Road 317 P.O. Box 925 Buena Vista, CO 81211 Water & Wastewater • Systems • Products • Service Website: http://valleyprecast.com/ Email: frontdesk@valleyprecast.com