HomeMy WebLinkAboutGas Fireplace SpecsSLAYTÍIN SERIES
0ptional Accent Media
ASPEN GLEN GV 13
CARBONDALE, CO 81623
Driftwood Log Set
Glass Media
Crushed Glass
Reflective Midnight Reflective Copper
Tradìtional Log Set
Crystals
Glacier Amber
Rock
4
Driftwood/Rock Black Seabreeze
SLAYTÍIN SERIES
Specifications
Remote Control
Burn Videos
ASPEN GLEN GV 13
CARBONDALE, CO 81623
Remote control features:TM
I(ou¡'ogrl(o¡l:rnor û
À
tr
I
llf
&
Thermostat function
Flame height modulation
Fan speed modulation
Light kit modulation
lPl to continuous pilot
Split Flow 0ption
(Slayton 60 & 42S only)
The Komfort Kontrol remote gives you the ability to bring comfort and green technology all
together into your home. With the Komfort Kontrol remote, all you have to do is decide a
comfortable set point temper¿ture on your remote and when the room temperature gets closer
to the point you desire, the Komfort Kontrol remote will turn the flames down accordingly! And
with our zone heating, you can save energy and enjoy time in the room you use the most by just
turning down the central heat, setting your Komfort Kontrol remote, and enjoy your time around
the fireplace with friends, family, or just a good book! That way you'll get to have heat where and
when you need it while saving energy and money with just a click of the Komfort Kontrol remote!
ffi ffi
Slayton 60 Slayton 42S Slayton 36
Outdoor Covered Fireplace lnstall
o Fireplaceoperation is approved from 40 degrees Fto 110 degrees F
. All wiring connections shall be in accordance with outdoor requirements of NECA NFPA 70
. All clearances and requirements in your appliance manual must be adhered to
ROOF OVERHANG
BACK OF
FIREPI.ACE
The overhang (A) must be a minimum of 1/2 or greater of the
roofline elevation (B) above the base of the fireplace.
The width of the overhang to each side of the appliance (C) must be a m inimum of 1/2 or
greater of the roofline elevation (B) above the base of the fireplace.
A
B
EXAMPIE: lf roofline (B) is 10 ft. above the base of the fireplace, the overhang (A) must be 5 ft. or greater. The width of the
overhang to EACH side of the fireplace (C) must be 5 ft. or greater.
SIDE OF
FIRIPLACE FRONT OF
FIREPLACE
cG
SLAYTON 42S
Specifications and Clearances
(See Vent System Requirements on page 6)
Features, 1pti1ns & Spec¡f¡cations arc subiect t0 change.
Clearances
Refert0 the ¡nstallation manuals for complete installation & venting requirements.
See additi0nal mantel clearance c0nfigurations in the installati0n manual.
Each unit factory tested
Certified to ANSI 221.88 Vented Gas Heaters
ASPEN GLEN GV 1 3
CARBONDALE, CO 81623
GAS LINE
HOtE
s-Ul',
TOP
Slayton 42S
3/8',55-1/4'
LEFT SIDE FRONT
38-5/16'
50'
55-114"
CORNER
92-l
19" (483mm)* is the minìmum wall depth required for wall surface materi¿l t0
cover fireplace front. lf fireplace face ìs to be flüsh with the wall surface, subtract
1/2" (13mm) (typical non-combustible finish material) from this dimensi0n. lf other
material is to be used, adjust accordingly.
o
15-13/16'
RIGHT SIDE
5-1tz',
IV Recess Construction
GAS TINE
HOtE
5-t/4',
ELECIRICAL
ACCESS
ffitMil0 stuÐs tusI
Mr[Âril f ctrÆact
T0vEMrilû
19'
32-9tr6',Height
50'widrh
50'Back Width
15-13/16',0opth
220 lbs.tusight
15-l 1/16" x 42-3l8"Viewing Aroa
[G High / low 42,000 / 15,000
LP lligh / Low 42,000 / 15,000
EIIEROUIDE P.4 I{O / tP 72.21% I 75.53v.
Steady State ilû / [P 72.98v. / 75.45%
AFÛE%ltc/tP 68.0s% t 70.39%
Valve Systsm tPt
StandardSpllt Flow Burner
Enamel (curved)Standard Refractory
Requiredûlass Msdia
0ptionalAccent ilodia
0ptionalFan lfit
Standardtinhhing Trim lfit
RequiredScreoÍ Front
Model Slayton 42S
9-15/1
5-3t4",/:\r
I
15-1V16"
42-3/8h
-
8-
9-11/16'
4"Fmm Applianæ Comen
0"From unit left & right side stand-offs & back
36',Top of fin¡shing edgeto ceiling
6',Side offinishing edge t0 adjacent sidewall
Unlt front to combustibles 36',
t4-v4"
*9" deep prolectionMantel projection from Tireplace finishing edge*
Slayton 42SModel
38-3/8',
38-3/8',
1t[',
SLAYTÍIN 60
Specifications, Clearances
(See Vent System Requirements on page 6)
Featurcs, 1pti\ns & Specifications are subiect t0 change.
Clearances
Refert0 the installation manuals for c0mplete ìnstallation & venting requirements.
See additional mantel clearance c0nfigurati0ns in the installation manu¿1.
Each unit factory tested
Certified to ANSI 221.88 Vented Gas Heaters
ASPEN GLEN GV 13
CARBONDALE, CO 81623
Slayton 60
LEFT SIDE
3/8',
TOP
7 l-1116',
TRONT
l5-13/16"
15/16',
77 -7 l8',
TV Recess Construction
RIGHT SIDE
5-U4',
36-7/8', 3
5-U4',
CORNER
1 10-l/8'
4',7r-
NÄililGSIUDSTUST
M^lilIAtff f ctrñANCt
l0vt[tilc
19" (483mm)* is the minimum wall depth required for wall
surface material to cover fireplace front. lf f¡replace face is t0
be flush with the wall surface, subtract 1/2" (l3mm) (typical
n0n-c0mbustible f¡nish material) from this dimension. lf other
material is to be used, adjust accordingly.Fìreplace brochures are for advertising purposes only.
Refet t0 the specific lircplace nanual for installation.
r 19'.--r{
31-Vi6"Heíght
66',Ividth
66"Back Widtft
l5-13/16"Dêpth
Weight 300 lbs.
Vievr¡ng Aroa l4-ll4" x 58-3/8"
ilo fligh / Low 55,000 / 17,500
LP ͡gh / Lon 55,000 / 17,500
73.317" I 75.287"ElttRGUtDt P.4 llc / LP
68.6% I 70.5%Steady State ilû / LP
66.44v. I 68.27"/.ATUE%I{G/I.P
tPtValve SysÌem
StandardSplit Flow Burn8r
Enamel (curved)Standard Relractory
RequiredGlass Media
0ptionalAccsnt Modia
0ptionalFan Kit
StandardFiÍishing Trim lfit
RequiredScreen Front
Model Slayton 60
5-3/4',
14-U4',
58-3/8',
I
8-V8'
4"From Appliance Cornen
From unit left & right side stand-offs
& back
0'
Top ofTinishing edgeto ceiling 36',
Side 0ff¡nishing edget0 adjacent sidewall 6'
36',Unit front to combustibles
Mantel projection from fireplace finishing
edge*
r4-1/4"
*9" deep projection
Slayton 60Model
62-vL',
36-7/8"
11-U8"
36-7l8',
l-l/8'
ln order to continually provide the highest quality product available, features/options, specifications &
dimensions are subject to change. Refer t0 the unit installation manual for complete installation instructi0ns.
lnstallati0n must conform with local building c0des. ln some regions it may be p0ssible that this appliance
qual¡fies for an energy rebate. See y0ur local deâler f0r details regarding pr0moti0ns and qualificati0ns.
F0r complete information 0n the l(ozy Heat
product line, please contact us at:
F0R CAUF0RiltA RrSr0Er{rs 0iltY
A California Proposition 65 lvarning
WARillt{û: This product can expose you to chemicals including Carbon Mon0xide, that is an externally
vented by-product 0f Tuel combustion, which is [are] known to the State of California to cause birth
defects 0r other reprodüctive harm. For more information, visit wwwP6SWarnings.ca gov
Manulactured by Hussong Mfg. Co., lnc.
204 lndustrial Park Road, Lakefield, IVlN 56150
Ph0ne1-800-253-4904www.kozyheat.com 10-20
ffi
tHl ,fF.¡EIml
Product Line: