HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
B LRE-0 9 -23-830ó
DIAMOND J LLC
New 1,981 sq ft Primary Residential Dwelling &
1 ,486 sq ft attached garage
TBD River Ridge Dr, GWS
River Ridge PUD, Lot 1 - 239501210001
1 ) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)AND 2018
I NTERNATIONAL EN ERGY CONSERVATION CODE ( I.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERMTTTTNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRTCAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNIry DEVELOPMENT WEBSITE FOR
ADDITIONAL I N FORMATION.
5) OPEN HOLE SOTLS REPORT rS REOUTRED AT FOOTTNG TNSPECTTON AND PR|OR TO ANY CONCRETE
POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR.
2,500 PSF AS SPECIFIED BY THE GEOTECH.
ó) pRE-ENctNEERED ROOF TRUSSES. HAVE ENGTNEERTNG FOR BUTLDTNG TNSPECTOR AT TrME OF
FRAME INSPECTION,
7) SEPTIC SYSTEM REVIEW / APPROVALS: PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF
OCCUPANCY PROVIDE FINAL APPROVAL / SIGN-OFF FROM GARFIELD COUNTY'S PUBLIC HEALTH
DEPT.
8) BLOWER DOOR TEST tS REOUTRED. MUST SUBMTT BLOWER DOOR TEST REPORT TO GARFTELD
COUNTY COMMUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING
INSPECTION / C.O. FINAL.
9) PRESCRIPTIVE PATH HAS BEEN CHOSEN FOR ENERGY COMPLIANCE OF THE HOME DESIGN.
WRIGHTSOFT LOAD CALCULATIONS ATTACHED FOR REFERENCE. SEE SHEETS AOOO, AOO2, A3OO
AND A3O1 FOR MORE DETAIL. ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL
VENTILATION SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1)AND (2) SHOWN ON SHEET A-1 )