HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-10-23-8351 Richard Sheets Foundation Repairs 59 CR 3L7, Rifle 217729200489 1) ALL WORK MUST COMply W|TH 2015 TNTERNATTONAL RESTDENTTAL CODE (lRC)AND ENGINEER OF RECORDS SOIL EVALUATION AND STRUCTURAL REPAIR PLAN. 2',) TH|S PERMtT tS TSSUED FOR FOUNDATTON REPATRS ONLY. ADDITIONAL REPAIRS TO THE RESIDENTIAL BUILDING STRUCTURE - IF DEEMED NECESSARY _ MAY REQUIRE A SEPARATE BUILDING PERMIT. IF ADDITIONAL STRUCTURAL DEFICIENCIES ARE ENCOUNTERED DURING FOUNDATION REPAIR WORK, THEN A SUBSEQUENT EVALUATION AND STRUCTURAL DETAILS MAY BE DEEMED NECESSARY FROM THE ENGINEER OF RECORD. 3) ENGTNEER OF RECORD SHALL FrELD VERTFY TNSTALLATTON OF 11 PUSH P|ERS ALONG NORTH AND NORTHEAST FOUNDATION WALLS OF THE BASEMENT PERIMETER. ENGINEER'S STAMPED APPROVAL REPORT IS REQUIRED AT BUILDING FINAL INSPECTION. 4) tF GAS METER tS DTSCONNECTED, A GAS PIPE PRESSURE TEST AND INSPECTION MAY BE REQUIRED FOR METER RECONNECTION. 5) FTNAL BUTLDTNG TNSPECTTON BY GARFIELD COUNTY BUTLDING DEPT rS REQUTRED AFTER COMPLETION OF FOUNDATION REPAIRS. '' oì \:ifu;r';,l:t li 1 li;llt ;tri¡r ri,lrJii .i..l. t,tI GENERAL COMMENTARY, LIMITATIONS ANd ATTACHMENTS AQror¡ndworks Company ËIETTRßAL PËRMITTINT & INSPÊCTIONS ARE BY THË CCItORAOO STÂTE ËLECTRIOAL BOARD GENERAL COMMENTARY The recommendations provided herein are based on our understand¡ng of the project and subsurface characteristics at the time of this report. Based on actual field conditions, helical piles may be installed instead of push piers. lf differing project conditions are encountered, Groundworks field personel shall notify Engineering Depa rtment im mediately for resolution. Unless determined by a site specific soil boring and laboratory soils anlysis, the bearing capacity (net allowable soil pressure) referenced in the first page of this report is based on our experience with soils in the project area as well as the "Presumptive Load-Bearing Values" as outlined in the referenced version of the lRC. Any perimeter pier may be installed on the interior or the exterior of the structure at the discretion of the Contractor. lt should be noted that subsurface conditions can vary across the site due to natural occurence or PROJECT: ADDRESS: DATE: Chri Fitzsi Yes Yes iåffi'ffiflffiË*ffi-f¡i$'åft by Fitzsimmons ATTAGHMENTS: -06'00' A. ICC Evaluation Report ESR-5005 IMG Push Pier Mod PP21617-34 B. Ultimate Driving Force Correlation Document REVIE\ryED FOR CODE COIWPLTANCE ,:'' r suBIEcr ro NorED EXCEITIONS & INSII:c't'rt)NS GARFIELD COUNTY COMMUNITY DEVELoprvt¡iNT ' :' ,,. DATE P-lq-k1r' û¿ilti+/, Rick Sheets Road 317,81650 NO INSPECTION \MITHOUT THESE PLANS ON SITE REPORT PAGE 4 ,, iii 1l\/iI;j{)tjl []illot'1ì1k] I I i Ir,{rlil l1; tr'l): ì DESIGN CALCULATIONS/PIER DETAIL A Groudworks Contpany PROJEGT: ADDRESS: DATE: DESIGN CALGULATIONS: . Based on wall loading and building characteristics outlined in the front page of this report. of this report, assume a wall load of . Push Piers Design Spacing Calculation for additional 6", see plan for spac. . Using the wall load and pier spacing indicated above, the load on each will be PIER LOAD = Wall Load x Spacing =bs lsEE NOTE f BELOWI . Using a Factor of Saftey of 2, the minimum driving force will be: MINIMUM DRtvtNc FoRcE = pier Load x 2 = l@l'ot DESIGN COMMENTS: NOTE 1: This actual load is less than the "Average" Allowable Load per Pier of 29.3 kips; therefore OKAY). Factor of Safety (FS) exceeds 2. See allowable system capacity ratings in the lÇÇ Evaluation Report ESR-5005 (attached). Push Pier/Bracket Detail (Typ.) ,- -: r:¡ ¡rii r ¡lÈr¡1. ¡ .k: ntrT-ìfrt;c.11ra,:rr¡rl, ì :'I'¡- ,- I ! I .¡1. tst! Ã:¡l ¡:. " ! 9¿!r.r lJ¿._Þ c¿:4r-l:,.,É Þ]ts¡ a!¿h,r¡' : tsa l¿- ..IF'€rrC.-r6r ¿: r.,¡t, .¡Þ ¡ : | ¡È È! Frf È Êr:t ! t¡la Chris Fitzsi by monS 09:09;18 Road 317,I .000 REPORT PAGE 3 ENGINEERING F'OR FOUNDATION STABILIZATION CODE: BLDG DEPT.: A Gromdworks Contpany DATE: Ch ris PROJEGT: ADDRESS: s GONTACT |NFO: Fitzsim 09:08:47 INSP.:INSP. DATE: inspection, the Groundworks lnspector and lhe client egreed to the following "ScopeOf-Work". SCOPE.OF.WORK:TY:Each ¡seeerAN-PAGE2l Feet ¡+¡ 6" allowablelISEE PRODUCT DETAILS. ATTACHED]SPAGING (Typ): GENERAL ISSUE: PROP. SOLUTION: STRUCTURE DESCRIPTION . Classification: . Style: . Stories: . Construction: . Exterior: . Foundation: STRUCTURAL DETAILS (ExrsrNG): . Foundation WallType: . WallThickness: . Wall Height: . Wall Reinforcement: . Unbalanced Fill: . Surcharge Load (On Walls): . Wall Bracing: lAssume Typ.l SOIL GONDITIONS: [At or Near Foot¡ng Depth] . Loads: [@ Footing Levell [Based on Typical IRC Load Tables] FIOOr: ILL + DLI [Add upper wall and point loads] . Footing Embedment Depth (Typ.): . Footing W¡dth (Typ.): lcont. wall + lsol. Pierl . Footing Thickness (Typ.): [Gont. wall+ lsol. P¡erl . Footing Reinforcement (Typ.): . Year Built - feet NOTE: Wall height might vary due to site grading and footing steps. NOTE: Fill depth for basement conditions may vary ILL + - ¡nches (Below Final Exterior Grade) - in. (Cont.)- in. (Square) - tn.-tn (Ø):. SoilType (USGS): . Allow. Brg. Gapacity:. Shrink-Swell Potential Frost Depth (in): SITE CONDITIONS: A. Footing Characteristics and Soil Conditions provided by: S co 81601 u 108 8th Street, #.401 nwood )temþer 29,2Q23 County Road 317, Rifle, CO 81650 J. Armendar¡z 9t21t2023 Mod PP21617-34MG 11 6.0 of the structure is setfling and needs to be stabilized. le Fami Residence e on 1 998 resent, the concrete slab is assumed to be 4" thick and resting on the footing top a 52 rm Available n mum - r N/A 1,500 NiA N/A N/A N/A N/A 36 N/A B. ls Site Plan Available (Y/N)? psf (ps0: . GWT(fr): REPORT PAGE 1 1 / il rll \l\l*:i()ÍtÍ (ìn r¡l;trlm Illi.,1rll.l /,\ tl.,l;'li l AQroundworks Company PROJECT: ADDRESS: DATE: GENERAL COMMENTS: 1 - Push Pier locations shown in drawing below SITE and LAYOUT PLAN / NOTES Push Pier Locations are approximate *3{J' Basement .¡.'. I PP2 PP3 Þ PP6 J-j :--l t' r; 'l Maximum Spacing is to be 6-feet on-center (+l- 6" allowable) and 3 feet from foundation corners Chri Fitzsi V IMG PUSH PIER '.'4 I I I I I'*PP1 by I r* Lf) 6' 6', 6 6' 6 09:09:05 PP4 PP5 PP8 PP7 .1 :...* >:-r _ a a t ¡ I , ¿ l¿ PP].1 PP1O PPg T.,T?3'6'ì.6'¿6'6'å3'l:r{,- !.!¡,î t t= t- " ,å, ".ç.':lü Rick Sheets Road 17, Desion Criterìa Building Code 2015 lBC, 2015 IRC with G¡rfi cld lÌnr ¡nlrr AmÊn.lmênlç Load Tvoe Load Cateoorv V¡h¡p Dead Loads Floor i2 Roof 20 Walls 10 Live Loads Floor. Residential 40 Roof 20 Snow Loads Ground 40 Roof 40 Wind Loads Risk Cateoorv 2 Exoosure Caleoorv c Ultimate Wind Soeed 1l mnh Seisrnic Load Seismic Dasion Cetêooru B tISGS Seiqmin Site ClssE Fãrlh Loed Soil Bearino CeDecitv 1500 osf NORTH REPORT PAGE 2