Loading...
HomeMy WebLinkAboutEnergy ReportGenerated by REScheck-Web Software Compliance Ceft¡ficate Project Glauber Residence Energy Code: 2021 IECC Location: Garfield County, Colorado Construction Type: Single-family Project Type: New Construction Conditioned Floor Area: L,94O Í12 Glazing Area 360/o Climate Zone: 5 (8499 HDD) Permit Date: Permit Number: Construction Site: Glenwood Springs, CO 81601 Owner/Agent; Peter Glauber Glenwood Springs, CO 81601 2,6L8 2,676 975 Designer/Contractor: Timberbuilt L0821 Eagle Drive North Collins, NY 14111 716-337-0072 Compliance: 1.69,/" Better Than Code Maximum UA: 474 Your UA: 443 The % Better or Worse Than Code lndex reflects how close to compl¡ance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Slab-on-grade tradeoffs are no longer considered in the UA or performance compliance path in REScheck. Each slab-on-grade assembly in the specified climate zone must meet the minimum energy code insulation R-value and depth requirements. Envelope Assemblies SIP - Roof: Structural lnsulated Panels (SlPs) SIP - Wall: Structural Insulated Panels SIP - Window: Wood Frame Crawl Wall: Solid Concrete or Masonry Wall height: 5.0' Depth below grade: 5.0' lnsulation depth: 4.0' Additional Efficiency Package(s) Required: L Proposed: 1 1,020 0.0 15.0 0.054 0.055 35.8 22.3 0.029 0.048 0.270 0.024 0.045 0.320 76 82 263 22 63 77 3L2 22 Compliance: Passes using UA trade-off Cavity R-Value Cont. R-Value Prop, Req, U-Factor U-Factor Prop. UA Gross Area Assembly Perimeter ReqorUA Description Credits Enhanced Envelope Performance 1.0 Project Title: Glauber Residence Data filename: Report date: L0126123 Page 1 of 2 Compliance Statemenh The proposed building design described here is consistent with the building plans, specifications, and other calculatlons submltted wlth the permlt appllcatlon, Thê proposed bulldlng has been designed to meet the 2021 IECC requirements in REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck lnspection Checklist. Name - Title Signature Date Project Title: Glauber Residence Data filename: Report date: LOl26l23 Page2 of 2 Receíved lo-23-Zg Glauber Residence HVAC Load Calculations for Peter Glauber Glenwood Springs, CO n 0Y \ \ tl (. I u u ( RHVAGtr^ffi- Prepared By: Friday, Octob er 20, 2023 Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D *' &hlVÀC Loads .ü Proiect Report Project Title: Designed By: Project Date: Client Name: Client City: Glauber Residence Timberbuilt Wednesday, August 2, 2023 Peter Glauber Glenwood Springs, CO Reference City: Building Orientation: Daily Temperature Range: Latitude: Elevation: Atifude Factor: 39 6539 0.785 Eagle, Colorado Front door faces North High Degrees ft. ,¡Outdoor Outdoor Wet Bulb -2.73 72.2 Outdoor Rel.Hum nla 460/o lndoor Rel.Hum 3lo/o 50o/o lndoor Dry Bulb 70 75 Grains Difference 36.47 41 .,'1;Dry Bulb -2 90 ,Total Building Supply CFM Square ft. of Room Area: 1,821 2,302 31,537 CFM Per Square ft. Squarefr. PerTon: 0.791 751 otal Heating Required lncluding Ventilation Air:48,709 Btuh 32,492 Btuh 4,303 Btuh 36,795 Btuh 48.709 MBH 88 o/o 12 o/o 3.07 Tons (Based On Sensible + Latent) Total Sensible Gain: Total Latent Gain: ToTal Cooli ng Required I ncluding Ventilation Air: is an ACCA approved Manual J, D and S computer program. .dlculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D AlLcomputed results are estimates as building use and weather may vary. su re to select a unit that meets both sensible and latent load accordi ng to the manufactu rer's perform ance data atry ..4 d esrgn conditions. li 3 i,a' ;*.* Ð ù h0. t.!1 ti P:\ ...\Glauber_Manuel J. rh9 Friday, October 20,2023,4:16 PM Rhvac ' Rèsldent¡al & Troutman & Assoôiâtes HVAG Loads Ellte Softwarc Dere¡opment, lnc. Glauber Residence Miscellaneous Wnter: Summer: -2 90 -2.73 72.2 80o/o 460/o 30o/o 5Ùo/o 70 75 36.47 41.00 Calculate: Use Schedule: Roughness Factor: Pressure Drop: Minimum Velocity: Maximum Velocity: Minimum Height: Maximum Height: Main Trunk No Yes 0.00300 0.1000 in.wg./100 ft. 0 ft./min 900 ft./min Runouts No Yes 0.01000 0.1000 in.wg./100 ft. 0 ft./min 750 ft./min0 in. 0 in. 0in 0in lnfiltration Specified \Â/inter 0.1 10 58 0.000x 31,537 0 x 0 0167 0 160 AC/hr CFM AC/hr Cu.ft. Cu.ft./hr CFM CFM Summer 0.060 32 0.000x 31,537 0x 0.0167 0 160 AC/hr CFM AC/hr Cu.ft. Cu.ft./hr CFM CFM lnfiltration Actual: Above Grade Volume: Total Building I nfiltration: Total Building Ventilation: --System 1-- lnfiltration & Ventilation Sensible Gain Multiplier: 12.96 = (1.10 X 0.785 X 15.00 Summer Temp. Difference) lnfiltration & Ventilation Latent Gain Multiplier: 21.89 = (0.68 X 0.785 X 41.00 Grains Difference) lnfiltration & Ventilation Sensible Loss Multiplier: 62J9 = (1.10 X 0.785 X72.00 \Â/inter Temp. Difference) \y't/inter lnfiltration Specified: 0.110 AC/hr (58 CFM), Construction: Tight Summer lnfiltration Specified: 0.060 AC/hr (32 CFM), Construction: Tight P:\ ...\Glauber_Manuel J.rh9 Friday, October 20,2023,4:16 PM Rhvac - Residential & Lisht Commercial HVAC Loads Troutman & Associates Elite Software Development, lnc. Glauber Residence Total Bu Summa Loads Component CO - 2021 IECC: Glazing-Window Min. U Value - 0.30, U- value 0.3, SHGC 0.4 148-6.5s: Wall-structural insulated panel (SlP), R -3.6 per inch EPS core, stucco or wood siding, interior finish, 6.5 inch R-22.6 SIP panels, U-value 0.05 13FB-0ocw: Wall-Block, framing with R-21 in 2 x 6 stud cavity, open core, wood studs, U-value 0.061 17 A1-10: Roof/Ceiling-Roof Deck (roofing, wood, insulation) or SIP Panels Supported on Beams, Structural lnsulated Panels (SlPs), R -3.85 per lnch EPS Core, Dark or Bold-Color Asphalt Shingle, Dark Metal, Dark Membrane, Dark Tar and Gravel, 10.25 inch R-40.36 SIP panels, U-value 0.029 19D-15sr: Floor-Over enclosed crawl space, R-l9 insulation on exposed walls, sealed crawl space, radiant R-15 hlankef I l-vah re O O64 Arèa 974 2447.5 229 2618 Sen 21,039 8,811 1,006 5,466 22,825 856 78 1,291 490 22,825 856 78 1,291 490 Let Sen Total 0 0 0 0 2302 3,171 0 Subtotals for structure: People: Equipment: Lighting: Ductwork: lnfiltration: Winter CFM: 0, Summer CFM: 0 Ventilation: Winter CFM: 160, Sunrnrer CFM: 160 Humidification (Winter) 11.56 gal/day : AED Excursion: 4 1151 39,493 25,540 920 0 0 800 0 0 0 503 0 0 0 0 1,037 0 1 071 25,540 1,720 0 3,925 0 0 4,539 0 1 071 3,925 0 0 ,975 ,240 0 3,4 4 Total Building Load Totals 48,709 4,303 32,492 36,795 Total Building Supply CFM: Square ft. of Room Area: Volume (ft3): 1,821 2,302 31,537 CFM Per Square ft. Square ft. Per Ton: 0.791 751 Buildino Loads Total Heating Required lncluding Ventilation Air: Total Sensible Gain: Total Latent Gain: Total Cooling Required lncluding Ventilation Air: 48,709 Btuh 32,492 Btuh 4,303 Btuh 36,795 Btuh 48.709 MBH 88 o/o 12 o/o 3.07 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J, D and S computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. P:\ ...\Glauber Manuel J.rh9 Friday, October 20,2023,4:16 PM Rhvac - Residential & Light Gommercial HVAG Loads Troutman & Associates EIite Software Development, lnc. Glauber Residence d Room Loads - Room 1 -Residence VE Load Procedure Calculation Mode: Room Length: Room Width: Area: Ceiling Height: Volume: Number of Registers: Runout Air: Htg. & clg. 230.2 10.0 2,302.0 13.7 31,537 '17 0 ft. ft. sq.ft. ft. cu.ft. Occurrences: System Number: Zone Number: Supply Air: Supply Air Changes: Req. Vent. Clg: Actual \Ninter Vent.: Percent of Supply.: Actual Summer Vent. Percent of Supply: Actual\Mnter lnfil.: ActualSummer lnfil.: 1 1 1 1 ,821 3.5 0 160I 160 9 0 0 CFM AC/hr CFM CFM CFM o/o CFM o/o CFM CFM N-Wall-148-6.5s1X827 S -Wall-148-6.5s 1 X 1350 E -Wall-148-6.5s I X 582.5 W-Wall-148-6.5s 1X662 N -Wall-13FB-Oocw 1 X 106 E -Wall-13F8-0ocw 1X 123 N -Gls-CO -2021|ECC shgc-0.4 100%s S -Gls-CO - 2021 IECC shgc-0.4 0oloS E -Gls-GO - 2021 lÊCC shgc-O.4 0%s W -Gls-CO - 2021 IECC shgc-O.4 0%s UP-Roof-1741-10 2618 X 1 Floor-19D-l5sr 1X23O2 627 784 465.5 571 106 123 200 0.050 0.050 0.050 0.050 0.06'1 0.061 0.300 3.6 3.6 4.4 4.4 21.6 2,257 2,822 1,676 2,056 466 540 4,320 0.4 0.4 0.4 0.4 0.3 0.3 12.3 0 0 0 0 0 0 0 0 0 0 0 0 219 274 163 200 36 42 2,460 566 0.300 1',t7 0.300 91 0.300 2',1.6 12,226 20.4 11,561 4,952 3,852 1,291 490 21.6 2,527 42.3 21.6 1,966 42.3 26',t8 )?o2 0.029 0 064 2.1 14 5,466 3 171 0.5 o2 Subtotals for Structure: lnfil.:Win.: 0.0, Sum.: 0.0 AED Excursion: People: 200 laUper, 230 sen/per: I iohtino: 3,651 4 1 151 0.000 39,493 0 0.000 0 0 25,540 0 1,071 920 3 925 800 Room Totals:39,493 800 31,456 P:\ ...\Glauber Manuel J.rh9 Friday, October 20,2023,4:16 PM t I --Za¡e 1-- 1 Glauber Residence 2,302 39,493 723 17-O o 31,456 800 1,821 1,821 Ventilation Humldiflealion 4,975 1,037 3,503 a 2Á.î System I total 2,302 48,709 723 32,492 4,303 1,921 ',1,821 Net Required:3.07 88o/o I 12o/o 32,492 4,303 36,795 Type: Model: lndoor Model: Brand: Effìciency: Sound: Capacity: Sensible Capacity Latent Capacity: Heating System Natural Gas Furnace Cooling System Standard Air Conditioner O AFUE O SEER 0 0 Btuh 0 Btuh 0 Btuh 0 0 Btuh nlâ nla P:\ ...\Glauber_Manuel J.rh9 Friday, October 20,2023,4:16 PM