HomeMy WebLinkAboutAs-Built OWTS Design Plan 11.01.2023O - - comer. NOTES OPRIS ENGINEERING, LLC. 5497 1250 Gallon Tv SZCP Top - CONNECT INDIVIDUAL 4" DISTRIBUTION PIPE 1. THE OWTS AS SHOWN ON THE PLAN AND THE DETAILS WERE DESIGNED BY 50PRI5 CIVIL CONSULTANTS TO HEAD DE EACH CHAMBER TRENCH {TYPICAL EACH TRENCH). ENGINEERING. INSTALL CONNECTION AS NEEDED FROM END OR SIDE INLET 502 MAIN STREET LOWER LEVEL FFE: 5595.33' Top PORT OF EACH INFILTRATOR CHAMBER END CAP. 2. THE PROPOSED LOT CONDITIONS BY SOPRIS ENGINEERING CARBONDALE, CO 91623 I970j 704.0311DOOR 5n9I TO UPPER DECK View FAX- (970)-704-0313 - _ _ - - - -- - . - 3. THE EXI5ITNG LOT CONDITIONS PER COUNTY G15 DATA BASE, LIDAR TOPOGRAPHY AND gg98 - -- --- •'°:=�,�oa. ��; �� r T .� AERIAL MAPPING. rf - - _ -- -- .. -- 4-BDRIvI 5A DWELLING -- --- --- -- s� 9y - •f O_'6.me.� slrar.A... naau.� f CHAMS R END CAP 4. PRIMARY OWNER NAME & ADDRESS: NILS5ON, STEVEN & CHRISTINE, 787 CANYON CREEK --- . TmeleGbdl.dun,lan.P W f.,� di Ww m" I i.." Uw ssd DR, GLENWOODSPRINGSGO8161]1 55� -,-Sob s� - s•,�.. ,---.-,-.,�.', .---;- S. LEGAL SUM MARY: Section: 12 Township.- 5 Range: 92 Subdivision: RIVERVIEW RANCH - �� �►+ 5541 i not b, ­k. °.+°+°� ",� SUBDIVISION Lot: 2 AMENDED, AS PER SECOND AMENDED FINAL PLAT RECEPTION NO. INSTALLED 4" 5DR-35 PVC SEWER PIPE @ 296 550z 18" 45" STEP FITTINGS UPPER LEVEL FFE: Ss S50S.125 ox 'kh .%U.f 1-M. r>o."'I. Fle toGmde w u.e. P41. M,.r f" � 965010 5.608 ACRES 28377 ? 3 '41tlP fl7i �d�3 °j 4" CLEANOUT INTERIOR EJECTOR PUMP r CHAMBER END CAP CONNECTION DETAIL N.T.S. 6. SITE ADDRESS: 167 SHORE DR, SILT, CO 81652 �' . ..' '•..,,. BASIN ASSEMBLY W/ INTERIOR Et�� �.." 7. PARCEL NUMBER: 217912301002`�0#VAL. , PLUMBING -1 S 2 �J wow.sa �.. B. NEW GAR FIELD COUNTY PERMIT # 5EPT-O8-22-7743 DESIGNED BY SS R '�` 9. CONTRACTOR: � CROWN FIELD TRENCH TO DRAWN BY p DIVERT SURFACE WATER CHECKED BY s _ p NILES-ON DESIGN CALCULATIONS OWTS ..t h� i ,9" ,r _, Sod n 4" PVC INLET PORT THE PROPOSED ONSITE WASTEWATER TREATMENT SYSTEM (OWTS) IS BEING INSTALLED View IN END CAP TO SERVE A SINGLE FAMILY RESIDENCE. THE PROPOSED RESIDENTIAL STRUCTURE HAS 4 DATE: 11-01-23 3' MIN 4' MIN BEDROOMS PROPOSED WITH A DESIGN FLOW BASED ON A TOTAL RESIDENTIAL 32029 ELEVATION NOTES: °"°"° �"� °'"" °" "" `�° "' "" `� POPULATION OF 7 PERSONS. THE RE51DENTIAL FACILITY OWTS CAPACITY DESIGN IS BASED JOB Na. o r . ". «w ur a,H+ ..om xan° "�, nr, s.. a°., rmn ... BACKFILL WITH SCREENED EVEG.ATAi"lCiN ON DESIGN FLOW FOR A 4-BEDROOM SINGLE FAMILY RESIDENCE. 100 = 5505.00' G �.. �.+ 36 51 iS5 60 !41gr <+. ,� 1,7A �. b. ,.� b. ONSITE SOILS FREE OF ROCKS IN EXCESS TOPSOIL NYC FFE MAIN LEVEL: 5505.125 55a 3 OF 3" DIAMETER OR USE 3/4" TO 1.5' 12"-24" SCREENED ROCK THE DESIGN FLOW TREATMENT CAPACITY IS CALCULATED AS FOLLOWS FOR A MINIMUM Pho„e: 71194954M VALL Y EQUIVALENT 2-BEDROOM SINGLE FAMILY RESIDENCE. FFE LOWER LEVEL: 5495.33' FIX 71941654M W17 PIMCAST,ina. VVe6eft www.ve1ryxeaadtcm FROM THE REGULATION 43 USAGE TABLE: FFE GARAGE BAY 1: 5503.57' PI:2+07.70 �e>naySEPTIC � MINIMUM POPULATION BASED ON 2 PERSON PER BEDROOM FOR THE FIRST 3 BEDROOMS 6 PERSONS AND 1 PERSON PER BEDROOM FOR EACH ADDITIONAL BEDROOM. 4TH E IC TANK DETAIL FILTER FABRIC LEACHING 32" = FFE GARAGE BAY 2: 5S03.67' GARAGE FFE: 5503.66' d � CHAMBER BEDROOM = 1 PERSON FOR ATOTAL OF 7 PERSONS. GALLONS PER DAY PER PERSON =75 BACKFILL LAYER NATURAL ONSITE GAL/PERSON/DAY, NO PEAKING FACTOR SOILS FREE OF ROCKS 6 MAX. DESIGN FLOW (QD)GALLONS/DAY = (# OF PEOPLE) X (AVG. FLOW)GAL/PERSON/DAY. i I LO SCARIFY/TILL BOTTOM SURFACE TO A DEPTH UNDISTURBED EARTH SIL DESIGN FLOW QD = 7 75 = 525 GPD 1 pF 3" LOAM SOIL. + COLORADO RIVER NOTE: ALL CHAMBERS IN EACH TRENCH MUST BE INSTALLED ON LEVEL a o �_� - - GRADE OVER 3" ASTM-33 FILTER SAND LEVELING COURSE. SEPTIC TANK DESIGN r+ � ~ MAXIMUM DEPTH OF TRENCHES NOT TO EXCEED 36" BELOW PROPOSED I GARAGE FFE: 5503.66' ~ �J � SURFACE GRADES. INLET AND END CAPS ARE TO BE INSTALLED ON EACH USE A 1250 GALLON, TWO COMPARTMENT CONCRETE SEPTIC TANK WITH AN EFFLUENT i END CHAMBER ROW. IF EXCESSIVE LARGE COBBLES OR BOULDERS ARE FILTER OUTLET SANITARY TEE IN THE SECOND CHAMBER. TANK SHALL BE I NSTALLED WITH _1 -- i ENCOUNTERED IN ANY PART OF THE EXCAVATION, OVER EXCVATE AND SEALED CONCRETE RISERS AND LIDS TO THE FINISH GRADE SURFACE. BACKFILL WITH SAND OR SUITABLE SCREENED NATIVE SOILS. CHAMBER TRENCH CROSS SECTION DETAIL PRELIMINARY SUB SURFACE CONDITIONS AND TESTING W INSTALLED 1250 GALLON 2-COMPARTMENT CONCRETE SEPTIC - � A PREVIOUS SUBSURFACE SOIL INVESTIGATION WAS PERFORMED BY KUMAR & w TANK (USE VALLEY PRECAST ITEM # IM 1000-2CP) W/ SEALED - - _ __ _-__`___ _=;_ Y ASSOCIATES, INC JUNE 9TH, 2022. THE RESULT OF THE SOILS EVALUATION IS PRESENTED IN RISERS AND LIDS INSTALLED AT THE FINISHED GRADE SURFACE. �- =_ DISTRIBUTION Box LID THE SUBSOIL STUDY FOR FOUNDATION DE51GN AN D PERCOLATION TEST, PROP05ED p INSTALL INLET SANITARY TEE AND OUTLET EFFLUENT FILTER PI 1+80173 - AT GROUND SURFACE RESIDENCE OF LOT 2 RIVER VIEW RANCH SUBDIVISION AT 167 SHORE DRIVE IN GARFIELD Q SANITARY TEE. DEPTH TO TOP OF TANK FROM PROPOSED GRADE IS APPROXIMATELY 24'. 55�3 - - r COUNTY COLORADO.THE SOILS ENCOUNTERED IN THE BUILDING ENVELOPE BORI NGS W J • 5. •' / /� RISER SECTION CONSISTS OF VERY STIFF, SLIGHTLY CLAYEY, SLIGHTLY 5AN DY TO SANDY SILT IN ALL THREE („] Q Z Cn d � PLASTIC DISTRIBUTION BOX WITH BAFFLE GA UTO CURT BAFFLE TEST BORINGS. THE SOILS ARE CHARACTERIZED AS A SANDY SILT LOAM WITH SLIGHTLY Z i W -INSTALLED LEVEL ON COMPACTED BASE j / 4" DISTRIBUTION BLOCKY AND GRANULAR STRUCTURE WITH MODERATE STRUCTURAL GRADE HAVING AN W ❑ ❑ INSTALLED RISERS AND LID TO SURFACE / / GRAVITY LINE LTAR OF 0.60 G/5F/D. Q Q V W t l 4" PVC EFFLUENT PIPE @ IN. 1% / FROM SEPTIC TANK A SUBSURFACE SOIL INVESTIGATION AND SITE ASSESSMENT WAS PERFORMED BY 50PRIS w U E S 0." PVC DISTRIBUTION PIPES (TYP.) o f Q p Q W W Z) I 4" SOLID PVC GRAVITY ENGINEERING IN ON JULY 20, 2022. THE 501LS IN THE PROP05ED FIELD ENVELOPE AREA Z W INSTALLED 4" RISER PIPE INSPECTION PORT EXTEND RISER LOT 2 DISTRIBUTION PIPES (TYP.) WERE SAMPLED AND CHARACTERIZED BY APPLICATION OF THE USDA VISUAL/TACTILE SOIL ()f =) �--. W/ CAP MIN. 4" BELOW FINISH GRADE & COVER WITH 6" r s 244,295 5Q FT TO ABSORPTION FEILD INVERT IN TEXTURE METHOD ANALYSIS FROM SAMPLES IN TWO PROFILE PITS. GENERALLY THE SOILS Z ❑ ❑ W ` DIA. VALVE BOX SET WITH LID 1" ABOVE FINSH GRADE 9 5.608 ACRES. A y B" AGREGATE BASE COURSE BELOW APPROXIMATELY 18 -24 INCHES OF PREVIOUSLY PLACED FILL CONSIST OF MEDIUM DENSE SILT LOAM TEXTURE SOIL WITH SLIGHTLY BLOCKY TO GRANULAR STRUCTURE TO 0 V LU = (TYP. EACH CORNER CHAMBER END CAP) O z < f COMPACTED SUBGRADE THE PROFILE PIT DEPTH OF 8 FEET. THE SOILS CONTAIN LESS THAN 5% SCATTERED GRAVEL U) U)J d EXCAVATION DEPTH 12 MIN.-4' MAX. BELOW SURFACE z r r r„ OR ROCK CONTENT TO THE 8-FEET DEPTH EXPLORED BELOW THE SURFACE GRADES. NO J W - It � , GRADE MINIMUM. 12" COVER OVER TOP OF CHAMBERS I + L DISTRIBUTION BOX DETAIL FREE WATER WAS ENCOUNTERED IN THE PIT EXCAVATIONS. NO EVIDENCE OF SEASONAL E Z U) 1 FILL &GRADE FIELD AREA APPROXIMATELY 3"-6" ABOVE - - - - � r � f 1 ' N.T.S. HIGH GROUND WATER OR REDOX CONDITIONS WAS OBSERVED IN THE PROFILE PITS. (4 cc- W < EXISTING SURFACE GRADES _ j SHORE DRIVE z OF: SEASONAL HIGH GROUNDWATER LEVELS ARE EXPECTED TO BE BELOW 20 FEET FROM THE r Q U) 4 �l EXISTING SURFACE GRADES ON THE RELATIVELY FLAT TERRAIN. (D C!7 EXISTING WELL I ABSORPTION/TREATMENT FIELD INSTALLED 52 QUICK-4 CHAMBERS IN 4 TRENCHES WITH 13 CHAMBERS PER ROW FORA r f PERMIT NO. 66673-F EXTEND 4" RISER PIPE MIN. 3" THROUGH END THE NATIVE SOILS SAMPLED FROM THE PITS, 2-3 FEET BELOW THE SURFACE, IN THE SITE PLAN CAP OR CHAMBER PRE VICINITY OF THE PROPOSED FIELD, ARE CHARACTERIZED AS A SOIL TYPE 2 CONSISTING OF l TOTAL ABSORPTION AREA OF 625 S.F. THE SYSTEM WAS PLUMBED FOR EQ,UALGRAVITY ,4n DISTRIBUTION. THE CHAMBERS WAS INSTALLED ON LEVEL GRADE IN EACH TRENCH. THE FORMED PENETRATION SILT LOAM TEXTURE WITH GRANULAR STRUCTURE. THIS SOIL HAS AN EFFECTIVE LOADING W BOTTOM OF EACH TRENCH WAS EXCAVATED TO A MAXIMUM AVERAGE DEPTH OF 36 b VALVE BOX 6" VALVE BOX SECURE WITH SCREWS RATE FOR CONVENTIONAL SOIL TREATMENT OF 0.6 GAL/S.F./DAY FOR A LEVEL 1 ` 1 INCHES BELOW THE EXISTING SURFACE GRADES, WITHIN THE UPPER HORIZON OF THE THROUGH PENETRATION CONVENTIONAL TREATMENT SYSTEM. THE EQUIVALENT PERCOLATION RATE IS ASSUMED (f) } NATIVE SANDY SILT LOAM SOILS & BACKFILLED WITH A MINIMUM 12-INCHES OF COVER CAP FLANGE INTO PIPE TO BE 20-30 M INUTES PER INCH. THE SOILS ARE SUITABLE FOR A SHALLOW Z OVER THE CHAMBERS. THE FINISH GRADE ACROSS THE FIELD IS SLIGHTLY MOUNDED A CONVENTIONAL ABSORPTION FIELD CONSISTING OF GRAVELLESS INFILTRATION CHAMBER ❑ 54.0' MINIMUM 4-INCHES ABOVE EXISTING ADJACENT GRADES. UNITS. 4" INSPECTION PORT RISE - - 1 4" EFFLUENT PIPE FROM ADDITIONAL OBSERVATIONS AND SOIL EVALUATION WILL BE PERFORMED DURING s s°9 DISTRIBUTION BOX CONSTRUCTION, BY 50PRIS ENGINEERING IN THE AREA OF THE PROP05ED ABSORPTION FIELD TO CONFIRM THE SOIL EVALUATIONS AND DESIGN CRITERIA. IF SOIL CONDITIONS ENCOUNTERED REQUIRE ADJUSTMENTS TO DESIGN CRITERIA OR THE DESIGN PLAN, - - :_ NOTICE WILL BE MADE TO COUNTY EHD AND APPLICABLE REVISIONS TO F1f „„rE,z� .:.Fn _" -. DESIGN/CONSTRUCTION PLANS AND REPORT WILL BE SUBMITTED. THE RESULTS OF ANY NiEC 5 TE•: f %•,.i i n QUICK-4 INFILTRATOR ADDITIONAL SOIL EVALUATION AND SOIL CHARACTERIZATION WI LL BE INCLUDED I N THE PROPERTY LINE I - QUICK-4 INFILTRATOR OR EQUAL BIO DIFFUSER AS -CONSTRUCTED DOCUMENTATION. r END CAP CHAMBER _-- "� SOIL TREATMENT UNIT/ ABSORPTION SYSTEM DESIGN INSPECTION PORT CONNECTION DETAIL y � THE TREATMENT/ABSORPTION FIELD 15 DESIGNED BASED ON UTILIZING THE EFFECTIVE y 11 '! N.T.S. LONG TERM ACCEPTANCE RATE (LTAR) FOR THE NATIVE 501LS AND THE APPLICATION OF �^ APPROPRIATE LOADING FACTORS FOR A SOIL TREATMENT UNIT SYSTEM UTILIZING GRAVITY DISTRIBUTION TO GRAVELLE5S CHAMBER TRENCHES. THE NEW TREATMENT l f SYSTEM AND ABSORPTION FIELD WILL CONSIST OF GRAVITY DISTRIBUTION OF SEPTIC TANK INSTALLED 4" RISER PIPE INSPECTION PORT EXTEND RISER W/�. .. ' . EFFLUENT VIA A DISTRIBUTION BOX TO INDIVIDUAL CHAMBER TRENCHES WITH CAP MIN. 4" BELOW FINISH GRADE & COVER WITH 6" DIA. , •. NATIVE, YARD OR LANDSCAPED SURFACE 0 o a 12.8' VALVE BOX SET WITH LID 1" ABOVE FINSH GRADE �' TREATMENT ACROSS THE NATIVE SOIL ABSORPTIVE SURFACE. RECORD DRAWING l 30.3' (TYP. EACH TRENCH CHAMBER END CAP). " LONG TERM ACCEPTANCE RATE (LTAR) } INSTALLED CHAMBER END ` ! R100.00 sso �M, Y�• �/� - CONSIDERING THE APPLICATION OF THE STATE REGULATION 43. RECEIVING WASTEWATER TREATMENT LEVEL 1; CAP WELL SETBACK s \� ON ALL END CHAMBERS ; 6" MIN, EXCAVATED MATERIAL COMPACTED LTAR; (TABLE 10-1 501L TYPE 2 LOADING RATE IS (0.60 GAL./S.F./DAY); DESIGN FLOW; FLOW 525 GPD PROFILE PIT (TYP.) - _ ., y F��;3 1,; .`' - TO 90% STANDARD PROCTOR I! QD = (GAL/DAY) = LOADING FACTORS; (TABLE 10-2, GRAVITY APPLICATION TRENCHES, L.F.1 = 1.0) (TABLE 10-3, GRAVELLE55 CHAMBERS, L.F.2 = 0.7) •.' . ', 4 MIN. STU ABSORPTION TREATMENT AREA; A = AREA S.F.; OWTS ENVELOPE f a. :' ''•. r ► ;' r� . { . ;C,- ' . '.:, �� '. r '; '... SUITABLE BACKFILL OR 4" 4„ f CLASS &ROAD SASE A(SF) = QD X L.F.1 X L.F.2 .: A(SF) = 525 GPD X 1.0 X 0.7 = 612.50 S.F. LTAR 0.6 GAL/S.F./DAY DATE REVISION `rF COMPACTED SUBGRADE x - NUMBER OF QUICK-4 INFILTRATOR CHAMBERS 4'X3'XI2"CHAMBEIRS. TRENCH CROSS-SECTION FOR 612.50 S.F. = 51 CHAMBERS; USE 52 CHAMBERS VINCINITY AERIAL MAP SDR-35.26 OR SCHD-40 PIPES 12S.F./CHAMBER N.T.S. NUMBER OF EQUIVALENT ARC CHAMBERS 5'X3'X12"CHAMBERS: f 612.50 S.F. = 40 CHAMBERS; USE 44 CHAMBERS 15 S. F./CHAMBER USED 52 QUICK-4 INFILTRATOR CHAMBERS IN 4 TRENCHES 54' LONG BY 3' WIDE WITH 13 CHAMBERS UNITS PER TRENCH PLUS TWO END CAPS AS DELINEATED ON THE PLAN. l � l� } TITLE GRAPHIC SCALE f OWTS PLAN 10 a s 10 zo 40.................................... . .......... ( IN FEET } Know what's below. DRAWING N0. 1 inch - 10 ft. Call before you dig, '��T/�� ]"� ]''� T/y A ] 0 r/�/ 1 S ■ J ►y S1 / -V l LA ■►J ■■■■ lJL! �T l 1 Y CALL 2-BUSINESS DAYS IN ADVANCE ^ LJ DIG, BEFORE YOU DIG, GRADE, OR EXCAVATE .' FOR THE MARKING OF UNDERGROUND MEMBER LJTI LITI ES