HomeMy WebLinkAboutOWTS Permit Revised 11.16.2023
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945‐6614 ext. 8150
For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: Lot 32, Mountain Springs Ranch, Glenwood Springs, CO 81601
Parcel No.: 218520300048
Owner Name: Jack Cody Owner Phone: (724) 825‐2056
Designed By: SGM, Inc. Designer Phone: (970) 945‐1004
Number of Bedrooms _4__Minimum Tank Capacity _1,250‐gal__Minimum Absorption_840 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT‐7558 REVISED________________________
Permit Type X New X Repair X Remodel/addition X Tank only X Field Only X Amendment
Issue Date 11/16/2023 Expiration Date 11/16/2024
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the REVISED design as submitted
by SGM, Inc. dated November 13, 2023. Changes must be approved by Garfield County Public Health
and the designer prior to construction.
The new OWTS will serve a new four‐bedroom residence. The system will consist of a new, two‐
compartment 1,250‐gallon septic tank set level with access to grade with a pump capable of
providing 10 GPM and ½‐HP with a 1.5” discharge pipe. Effluent will be pressure‐dosed to an
automatic distributing valve (ADV) set level with access to grade at the high point of the system that
will distribute effluent to 864 ft2 of STA. At The new STA will consist of a four gravelless chamber
trenches consisting of 18 chambers per trench (72 chambers total). Laterals and the pump line shall
consist of 1.5‐inch diameter Schedule 40 PVC. Laterals shall have 1/8” orifices every 4 feet on center.
Orifices shall be facing up except for the first and last orifices. Laterals shall end in a sweeping 90‐
degree ell facing up with a ball valve to allow flushing of the lines. Inspection ports are to be installed
at each corner of the bed. Maintain all setbacks and elevations as designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as‐built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
11/16/2023
Issued By: Garfield County Environmental Health
Department
Date