HomeMy WebLinkAboutConditions of PermitCONDITI ONS OF P ERM¡T BLRE-10-23-8403 MEGHAN GREENHOUSE RESIDENTIAL REMODEL OF EXISTING 5,620 SO FT PRIMARY RESIDENCE WITH REMODEL SCOPE INCLUDING ALTERATION OF ATTACHED 828.4 SO FT LOWER LEVEL ADU (ACCESSORY DWELLING UNIT) 3 SEVEN OAKS RD HOMESTEAD EST., LOT 4 - 218736200004 1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.) AND 201B INTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACH ED "GARFI ELD COU NTY BUI LDI NG REOU I REMENTS". NUM BER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRTCAL pERMtTTtNG AND TNSPECTTONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COM M U N ITY DEVELOPM ENT WEBSITE FOR ADD ITIONAL I N FORMATI ON. 5) OPEN HOLE SOTLS REPORT tS REOUTRED AT FOOTING INSPECTION AND PRIOR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. 2,OOO PSF MAX. SOIL BEARING (SPECIFIED BY STRUCTURAL ENGTNEER ON 50.001). 42 TNCHES FROST DEPTH FOR SrTE OVER 8,000 FT ELEVATION. ó) SMOKE DETECTORS AND CARBON MONOXIDE ALARMS REOUIRED THROUGHOUT THE EXISTING RESIDENCE PURSUANT TO 2015 IRC SECTION R314 AND R31 5. 7) FIRE SEPARATION REOUIREMENTS PERTAIN: SEE SHEETAl01 H¡GHLIGHT OUTLINING INTERIOR FIRE SEPARATION BETWEEN PRIMARY RESIDENCE AND 828.4 SO FTADU ON LOWER LEVEL. OWNER BUILDER / PROJECT MANAGER SHALL INSTALL 2 LAYERS OF 5/8 TYPE X ON CEltlNG LID; INCADENCENT IIGHTS MUST BE PROTECTED (TENTING); AND ALL DUCT PENETRATIONS WITHIN THE ADU TO HAVE FIRE.DAMPERS. B) SEE PLAN ATTACHMENT ITEM #ó0, FOR PROPANE INSTALLATION IN BASEMENT LOCATIONS. 9) SHEET A10'1, LOWER LEVEL SAFE ROOM ACCESSED FROM BEDROOM 3 CLOSET SHALL ONLY BE USED FOR FUTURE NON-HABITABLE STORAGE USE ONLY. SAFE ROOM IS NOT ALLOWED FOR FUTURE USE AS A HABITABLE LIVING OR AN ADDITIONAL BEDROOM. 10) BASEMENT WTNDOW WELLS SHALL COMPLY WITH PLAN ATTACHMENT #28 AND #29 AND 2015 IRC SECTION R310. 1 1) SHEET A103 UppER LEVEL OFFTCE LOFT AND STORAGE SPACE lS NOT ALLOWED FOR FUTURE USE AS A BEDROOM (NO EMERGENCY ESCAPE AND RESCUE OPENING). FIELD VERIFY HABITABLE LIVING SPACE ON UPPER FLOOR MAINS REOUIRED NATURAL LIGHT AND VENTTLATTON (OR EOUTVALENT MECHANICAL VENTILATION PURSUANT 2015 IRC SECTTON R303.4). \ ,ì A s \¡J ri \0 I f N)