Loading...
HomeMy WebLinkAboutOWTS Permit Card  Garfield County Public Health  2014 Blake Ave.   Glenwood Springs, CO 81601  Phone: (970) 945‐6614 ext. 8150  For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable   Project Address: 489 Harmony Way, Silt, CO 81652  Parcel No.: 217922101020  Owner Name: Kenneth and Hannah Williams    Owner Phone: (719) 371‐4805  Inspected By: Boundaries Unlimited    Designer Phone: (970) 945‐5252  Number of Bedrooms: _4     Minimum Tank Capacity: 1,250‐gallon     Minimum Absorption: 1,050 ft2    OWTS PERMIT   KEEP AVAILABLE AT PROJECT SITE   Permit Number _SEPT‐8489_______________________________  Permit Type X New X Repair X Remodel/addition X Tank only   Issue Date _01/12/2024____________________ Expiration Date_01/12/2025_________________  Permit Conditions:   This OWTS Permit is approved on the condition of compliance with the report and design as  submitted by Boundaries Unlimited dated January 2, 20213. Changes to the design and permit must  be approved by Garfield County Public Health and the designer prior to construction.   The new OWTS will serve an existing 4‐bedroom residence. The system will consist of an existing,  two‐compartment minimum 1,250‐gallon septic tank with an effluent filter added to the outlet tee  of the tank. Effluent will gravity flow to a new distribution box set level with access to grade that will  distribute effluent to 1,056 ft2 of STA. The new STA will consist of 2 new gravelless chamber trenches  and 2 existing chamber trenches for a total of 4 trenches. The two new trenches will consist of 22  Quick4 chambers each, and the existing two trenches will have 2 additional chambers and 3 new  chambers added. All trenches will consist of 22 Quick4 chambers (88 Quick4). Inspection ports are to  be installed at each end of each trench. Maintain all setbacks and elevations as designed.    Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final  inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED  WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.      Agreement   All installations must comply with all requirements of the Garfield County OWTS regulations  including but not limited to the conditions specified above.   In consideration of the issuance of the permit, the applicant hereby agrees to comply with all  laws and regulations related to the zoning, location, construction, and erection of the proposed  OWTS and associated structures for which this permit is granted. The applicant further agrees  that if the above said regulations are not fully complied with in the zoning, location, erection,  and construction of the above described OWTS and structure, the permit may then be revoked  by notice from the Health Department and immediately become null and void.  The issuance of a permit and specifications of terms and conditions therein will not constitute  assumption of liability, nor create presumption that the local public health agency or its  employees may be liable for the failure or malfunctioning of any system. Permit issuance will  not constitute a certification that the system, the equipment used in the system, or any  component used for system operation will ensure continuous compliance with the provision of  the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.   Permit Approval  Plans and specifications for the proposed OWTS have been reviewed and are considered  satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated  in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from  the date of issuance unless construction on the system has commenced. An "as‐built" drawing  must be submitted and inspection of the system must be completed by GCPH before final  approval of the system will be issued.        01/12/2024  Issued By: Garfield County Environmental Health  Department  Date