Loading...
HomeMy WebLinkAboutPermit Card - Revised 01.16.24  Garfield County Public Health  2014 Blake Ave.   Glenwood Springs, CO 81601  Phone: (970) 945‐6614 ext. 8150  For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable   Project Address: 1708 CR 121, Carbondale, CO 81623  Parcel No.: _218932200033  Owner Name: SGJD, LLC      Owner Phone: (303) 495‐4837  Designed By: SGM, Inc.      Designer Phone: (970) 945‐1004  Contractor: RA Nelson      Contractor Phone: (970) 763‐8120  Number of Bedrooms:  7   Minimum Tank Capacity: 2,000‐gallon  Minimum Absorption: 1,250 ft2  OWTS PERMIT   KEEP AVAILABLE AT PROJECT SITE   Permit Number _SEPT‐7124_Revised______________________  Permit Type X New X Repair X Remodel/addition X Tank only   Issue Date _01/16/2024____________________ Expiration Date_01/16/2025_________________   Permit Conditions:   This OWTS Permit is approved on the condition of compliance with the report and design as  submitted by SGM, Inc. dated January 15, 2024. Changes to the design and permit must be approved  by Garfield County Public Health and the designer prior to construction. The issuance of this revised  permit renders all previous permits under this permit number null and void.    The new OWTS will serve a new 7‐bedroom residence. The system will consist of a new, two‐ compartment minimum 2,000‐gallon septic tank set level with access to grade with a pump in the  second chamber of the tank. Effluent will be pressure‐dosed to an automatic distributing valve set  level with access to grade that at the high‐point of the system to distribute effluent to 1,260 ft2 of  STA. The new STA will consist of one 12 feet wide by 105 feet long 3‐feet deep unlined sand filter  constructed with secondary sand media. The sand filter will have four distribution laterals with 1/8‐ inch diameter orifices facing up, with every fifth orifice facing down to allow drainage, spaced every  4‐feet on‐center along the laterals. All orifices that are facing down shall have orifice shields. The  pump line and distribution laterals shall be constructed of 1.5‐inch diameter Schedule 40 PVC.  Laterals will end in a sweeping ell 90‐degree bend with a flushing valve assembly. Inspection ports  are to be installed at each corner of the bed. Maintain all setbacks and elevations as designed.    Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final  inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED  WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.    Agreement   All installations must comply with all requirements of the Garfield County OWTS regulations  including but not limited to the conditions specified above.   In consideration of the issuance of the permit, the applicant hereby agrees to comply with all  laws and regulations related to the zoning, location, construction, and erection of the proposed  OWTS and associated structures for which this permit is granted. The applicant further agrees  that if the above said regulations are not fully complied with in the zoning, location, erection,  and construction of the above described OWTS and structure, the permit may then be revoked  by notice from the Health Department and immediately become null and void.  The issuance of a permit and specifications of terms and conditions therein will not constitute  assumption of liability, nor create presumption that the local public health agency or its  employees may be liable for the failure or malfunctioning of any system. Permit issuance will  not constitute a certification that the system, the equipment used in the system, or any  component used for system operation will ensure continuous compliance with the provision of  the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.   Permit Approval  Plans and specifications for the proposed OWTS have been reviewed and are considered  satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated  in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from  the date of issuance unless construction on the system has commenced. An "as‐built" drawing  must be submitted and inspection of the system must be completed by GCPH before final  approval of the system will be issued.        01/16/2024  Issued By: Garfield County Environmental Health  Department  Date