HomeMy WebLinkAboutOriginal OWTS Permit - REVOKED
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945‐6614 ext. 8150
For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: TBD Rodeo Drive, Rifle, CO _ Parcel No.: _217734300375
Owner Name: Mario D Rena Owner Phone: (970) 355‐0357
Designed By: American GeoServices, LLC Designer Phone: (888) 276‐4027
Number of Bedrooms: _3_ Minimum Tank Capacity: 1,000‐gallon Minimum Absorption: 563 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT‐8459_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _01/31/2024____________________ Expiration Date_01/31/2025_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by American GeoServices, LLC. dated October 30, 2023. Changes to the design and permit
must be approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve a new three‐bedroom residence. The system will consist of a new, three‐
compartment 1,000‐gallon septic tank with a high‐head effluent pump in the third compartment of
the tank. Effluent will be pumped to a manifold that will distribute effluent to 720 ft2 of STA. The
new STA will consist of two unlined sand filter beds, each bed consisting of two rows of 15 Quick4
chambers placed on 3‐feet of secondary sand material. Distribution laterals are to be 1 ½ inch
Schedule 40 PVC, with 3/16‐inch orifices 3‐feet on center and the laterals ending in flushing valves at
the distal end of the laterals. Laterals are to be hung from the underside of the chambers with
orifices facing upward. Inspection ports shall be installed at each end of each lateral. Maintain all
setbacks and elevations as designed.
Contact Garfield County Public Health at least 48 hours prior to requesting final inspection of the
installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILLED WITHOUT PRIOR
APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as‐built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
01/31/2024
Issued By: Garfield County Environmental Health
Department
Date