Loading...
HomeMy WebLinkAboutPlansSouth Elevation 23' 39'-4" New Lift Loading Platform SCA' 0 New Grip Bay Building Sas-ma"919MMA2 ARCHITECTURAL OWNER: GLENWOOD TRAMWAY LLC. (970) 945-4228 Al COVER SHEET, LIST OF SHEETS, PROJECT DATA ARCHITECT: WARREN PALMER (.9.74) 927-9442 A2 LOWER FLOOR PLAN, PHASE I SEQUENCING A3 MAIN LEVEL, TRAM DECK FLOOR PLAN + DETAILS STRUCTURAL ENGINEERING: CANYON ENGINEERING A4 GRIP BAY FLOOR, ROOF PLAN + DETAILS CHARLES PETERSON (970) 945-5138 A5 BUILDING ELEVATIONS A6 DOOR + WINDOW SCHEDULES, ADA RESTROOM DETAILS MEP ENGINEERING: BIGHORN MECHANICAL BLAINE BUCK (970) 241-8709 CIVIL CONTRACTOR: TBD C1 SITE PLAN C2 GRADING PLAN SITE: PARCEL #: 2185-0440-0005 (48.517 ACRES) MAILING ADDRESS: 51000 TWO RIVERS PLAZA ROAD STRUCTURAL GLENWOOD SPRINGS, CO 81601 PHYSICAL ADDRESS: NOT AVAILABLE S1 FOUNDATION PLAN, DETAILS LEGAL: SECTION 4 TOWNSHIP: 6 RANGE:89 A TR OF LAND IN LOT 5&7. S2 LOWER FLOOR FRAMING PLAN, DETAILS EXCEPT A TR OF LAND CONT. 0.14 AC +/- AS DESC IN BK 1107 PG874. S3 MAIN LEVEL, TRAM DECK FRAMING PLAN + DETAILS S4 GRIP BAY FLOOR FRAMING, ROOF FRAMING + DETAILS ZONING: GARFIELD COUNTY "CAVERNS SPECIAL USE PERMIT°' S5 FOUNDATION DETAILS S6 FOUNDATION DETAILS BLDG. HT: 46-0 (SEE SHEET A3) S7 STRUCTURAL DETAILS THE DISTANCE FROM NATURAL OR FINISHED GRADE, TO THE MID -POINT S8 STRUCTURAL ELEVATIONS (EAST + WEST ELEVATION) OF THE EAVE AND RIDGE. S9 STRUCTURAL ELEVATIONS (NORTH + SOUTH ELEVATION) S10 BUILDING SECTIONS DESCRIPTION: 3 STORY COMMERCIAL ADDITION TO THE EXISTING CAVERNS S11 GENERAL STRUCTURAL NOTES STRUCTURE. THE STORAGE AREA, OFFICES AND TRAINING AREA WILL BE HEATED USING A FORCED AIR SYSTEM. THE GRIP BAY (2 MECHANICAL, ELECTRICAL, PLUMBING (MEP) STORIES) WILL BE HEATED WITH A GAS UNIT HEATER. THE UPPER LEVEL OF THE EXTERIOR TRAMWAY LOADING AREA WILL BE SNOW MP1-1 MECHANICAL/PLUMBING - LOWER + MAIN LEVEL FLOOR PLANS MELTED WITH A BOILER UNIT. SEWAGE WILL BE TREATED WITH MP1-2 MECHANICAL/PLUMBING - UPPER + ROOF FLOOR PLANS THE EXISTING SYSTEM AND GRAY WATER WILL BE SENT TO THE MP1-3 MECHANICAL/PLUMBING - SCHEDULES CITY OF GLENWOOD SANITATION DEPARTMENT. MP14 MECHANCIAL/PLUMBING - DETAILS MP1-5 MECHANICAL/PLUMBING - BOILER DETAILS EL1-1 ELECTRICAL - LOWER + MAIN LEVEL FLOOR PLANS EL1-2 ELECTRICAL - UPPER + ROOF FLOOR PLANS THE GLENWOOD CAVERNS + ADVENTURF PARK CAVERNS GONDOLA 26-, GLENWOOD SPRINGS GARFIELD COUNTY, COLORADO NOTES: 1. BUILDING CODES: ALL WORK SHALL COMPLY WITH THE CURRENT CODES OF GARFIELD COUNTY, THE STATE OF COLORADO, THE INTERNATIONAL BUILDING CODE 2015. INCLUDING THE INTERNATIONAL ENERGY CODE 2009, THE INTERNATIONAL PLUMBING AND 2 iFG C MECHANICAL CODES, THE CURRENT NEC AND ALL LOCAL CODES HAVING JURISDICTION. OSED BUILDING TYPE: TYPE II -A SPRINKLED BUILDING 3. PROPOSED ENERGY COMPLIANCE: WINDOW AND DOORS, U-0.35 OR LESS. MINIMUM R-VALUES, CEILINGS AND ROOFS, R-38 WALLS, R-20 FLOORS, R-30 BASEMENT WALLS, R-10 / R-13 SLAB PERIMETER AND DEPTH, R10/24-IN CRAWL SPACE, R-10/13 4. AREA CALCULATIONS: SEE SHT. A2 LOWER LEVEL, 1,190.25-SF MAIN LEVEL, 1,190.25-SF UPPER LEVEL, 553.92-SF TOTAL 2,934.42-SF APPRO D EXCEi' i �,,' n _ j _ Y eUi GATE FIELD COPY NO INSPE0,70". WITHOUT THESE. PLA,1,1S 0I,,11 SITE 4 0 FRI m 0 0 Q 0 0 U z w J z� a } cy�: 0 J 0 00 0 w O w 0 "' DO 03 PA IN ^, AT B TH SIDES OF B M WEB. ... FLOOR JOIST. j" DROPPED T GRID ' CEILING. R20 BATT INSULATION IN -------- FRAMED 6" WALL. OWNERS OPTION TO FIR TO FACE OF CONCRETE - INSULATION FOR - CONTINUOUS WALL PLANE. - - 1X NON-COMBUSTIBLE FASCIA W/ DRIP EDGE UNDER ROOF MEMBRANE, FOUNDATION WALL BEYOND. PHASE I WALL SYSTEM. NON-COMBUSITIBLE SIDING ON TYVEK BUILDING WRAP OVERY" FIRE PROOF SHEATHING OVER Y2` PLYWOOD SHEATHING ATTACHED TO STEEL STUDS. SECURE CORNER OF WALL SYSTEM TO CEILING ABOVE. — WATERPROOF CAULKING AT TRACK. TOR 88'-4 3" RIGID INSULATION (R13) ON INSIDE FACE OF CONCRETE WALLS ABOVE THE FLOOR SYSTEM. FINISHED WITH %" TYPE-X GYP BOARD. INSTALL BITUMINOUS MEMBRANE ON BACKFILLED SIDE OF ALL FOUNDATION WALLS. INSTALL FOUNDATION DRAINS AS REQUIRED. 2" RIGID INSULATION (R10) IN CRAWL SPACE ON INSIDE FACE OF CONCRETE WALLS. \ TYP WALL INSULATION A2 Scale: 1/2" = P-0 PHASE II WALL LOCATION. FLASHING FROM STEEL BEAM TO ROOF MEMBRANE. 12 Y8 ` TYP-X GYP BOARD CEILING (FIRE TAPED FINISH) 6" STEEL STUD BLOCKING FILLED WITH R20 INSULATION. —1X NON-COMBUSIBLE SOFFIT ON Y" FIRE CODE RATED SHEATHING. 6`-6" %"TYPE-X GYP BOARD ON 6" STEEL STUDS @ 16" C/C W/ MIN R20 BATT INSULATION. POMA DRIVES CONDUITS FROM CRAWL SPACE BELOW. COORDINATE SLAB CORE DRILLING AND FOUNDATION BLOCK OUT WITH LIFT MANUFACTURER. SECTION A -A - PHASE I ELEC ROOM FRAMING SCALE: Y2" = 1 `-0 Y, 0 1 2 SEAL CONCRETE JOINT W/ WATERPROOF CAULKING. VERSASHIELD ROOF MEMBRANE OVER ICE + WATER SHIELD ON %" PLYWOOD OVER RIGID INSULATION (R38 MIN.) OVER %" PLYWOOD DECK BEARING ON 6" LIGHT GAUGE FRAMING. SEE ELEVATIONS FOR ARCHITECTURAL FINISH. FINISH OVER TYVEK BUILDING WRAP OVER Y" FIRE COAT SHEATHING COVERING Y2" PLYWOOD SHEATHING ATTACHED TO 6" LIGHT GAUGE STUDS. POWERED VENT IN WALL PER POMA'S REQUIREMENTS. COORDINATE WITH MANUFACTURER. Phase 11 Phase I --—FLOORJOIST 0 6" Y2" PLYWOOD SHEATHING W/ TYVEK BUILDING WRAP UNDERY2" FIRE CODE RATED SHEATHING. FLASH @ TRANSITION TO MEMBRANE ROOF. —. ROOF ASSEMBLY DETAILS. 3" RIGID INSULATION (R13) ON INSIDE FACE OF CONCRETE WALLS ABOVE THE FLOOR SYSTEM. FINISHED WITH %' TYPE-X GYP BOARD. LINE OF DECK ABOVE. FLASHING @ STEEL BEAM. ALL WALL FINISH UNDER FLASHING DRIP EDGE. R20 BATT INSULATION IN FRAMED 6" WALL. NON-COMBUSTIBLE FINISH OVER TYVEK BUILDING WRAP OVERY2" FIRE CODE RATED SHEATHING OVER Y2" PLYWOOD SHEATHING ATTACHED TO 6" STEEL STUDS.. SILL SEAL BELOW FOUNDATION TRACK STUD (TYP.) INSTALL BITUMINOUS MEMBRANE ON BACKFILLED SIDE OF ALL FOUNDATION WALLS. INSTALL FOUNDATION DRAINS AS REQUIRED. 2" RIGID INSULATION (R10) IN CRAWL SPACE ON INSIDE FACE O CONCRETE WALLS WALL ALONG GRIDLINE 4 TO THE COLUMN rya T _j EXTERIOR GRIDLINE B�\ LINE OF ROOF RATED STEEL - A/A A-2 EAVE ABOVE � - nOOR PHASE I .— TcneonneoV EGRESS TO EXTERIOR PATHWAY. RAMP CRAWL SPACE Lower Level Floor Plan - Phase I SCALE: Y4" = 1 `-0 0 2 4 B/B S-10 11 n Y1(I V I 14 c/c s 10 i� jV 1X NON-COMBUSTIBLE SIDING ON TYVEK BUILDING WRAP ON Y2" FIRE CODE RATED SHEATHING ON ON Y" PLYWOOD SHEATHING ATTACHED TO STEEL STUDS. - - Ve TYPE-X GYPSUM BOARD ON 6" STEEL STUDS W/ MIN R-20 BATT INSULATION. TYP WALL SECTION A3 Scale: 1 = 6" 1X NON-COMBUSTIBLE - SIDING ON TYVEK BUILDING WRAP ON Y" FIRE CODE RATED SHEATHING ON ON ... Y2' PLYWOOD SHEATHING ATTACHED TO STEEL STUDS. - 2X NON-COMBUSTIBLE CASING W/ FLASHING %" TYPE-X GYPSUM BOARD ON 6" STEEL STUDS W/ MIN R-20 BATT INSULATION. CAULK ---- b GYP. BOARD ALUMINUM CLAD - RETURN. WOOD WINDOW. -- - WALL HEAD (JAMB SIM) A3 Scale: 1 = 6" ALUMINUI WOOD WI 2X NON-C CASING. 1X NON-C SIDING 0 WRAP OP RATED SI Y2" PLYW( ATTACHE STEEL FRAME = MESH WINDOW PROTECTION IN GRIP BAY. GYP. BOARD - RETURN. 9/e" TYPE-X GYPSUM BOARD ON 6" STEEL STUDS W/ MIN R-20 BATT INSULATION. 3 WALL SECT SILL DETAIL A3 Scale: 1 = 6" Phase II _ Phase I A/A 0 6" 6" Fricfinn Plaffnrm Fzi} ,,NIif #y EXISTING WALL 3uc S CcsJ4 6 "� U L A CLASS 'A' ROOF. 22GA 1 y" CORRUGATED COLD ROLLED STEEL ROOFING ON VERSASHIELD UNDERLAYMENT ON ICE + WATER SHIELD ON PLYWOOD DECK. --� CLASS W ROOF. 22GA 1 Y2" CORRUGATED COLD ROLLED STEEL ROOFING ON VERSASHIELD UNDERLAYMENT ON ICE + WATER SHIELD ON 5Y8" PLYWOOD DECK. ---\ 22 GA RIDGE CAP OVER FLEXIBLE CONTINUOUS VENT CLIP CONNECTION FROM 6" LIGHT GAUGE STUD TO WEB OF STEEL RIDGE BEAM. RIDGE BEAM W/ RIDGE CAP PER eBLOWN URETHANE STRUCTURAL INSULATION (MIN R38) W/ PLANS. POLY VAPOR BARRIER BELOW. OPTIONAL" DRYWALL LID. 1 TWR ROOF + INSULATION A� Scale: 1 = T-0 / ,�-- V6" H. - 6" BLOWN URETHANE C CHANNEL INSULATION (MIN R38) W/ FASCIA PER PLAN PLOY VAPOR BARRIER W/DRIP EDGE. BELOW. OPTIONAL 5/e" 2X NON-COMBUSTIBLE DRYWALL LID. SOFFIT END CAP W/ 1X NON-COMBUSTIBLE SOFFIT BOARDS ON Y2" FIRE CODE SHEATHING. VENT SOFFIT BOX. 1X NON-COMBUSTIBLE SIDING ON Yz" FIRE CODE - RATED SHEATHING ON TYVEK BUILDING WRAP ON Y2" PLYWOOD SHEATHING. - ROOFSUPPORT BEAM PER PLANS. %" TYPE-X GYPSUM BOARD ON 6" STEEL STUDS W/ MIN R-20 BATT INSULATION. SHOOT TRACK INTO TOP & BOTTOM OF STEEL BEAM W/ POWDER ACTUATED FASTENERS (TYP.). TWR EAVE + INSULATION A4 Scale: 1 = V-0 CLASS W ROOF. 22GA 1 Yz' CORRUGATED COLD ROLLED STEEL ROOFING ON VERSASHIELD UNDERLAYMENT ON ICE+ WATER SHIELD OVER %e PLYWOOD SHEATHING ON 8" OF RIGID INSULATION (MIN R38) ON STEEL DECK BELOW. —� FLASHING OVER C� CHANNEL FASCIA. 2X NON -COMB. SOFFIT EDGE BOARD (NOTCHED) W/ 1X NON -COMB. SOFFIT INFILLOVER Y2 FIRE RATED SHEATHING. / STEEL BEAM BEYOND - 1X NON-COMBUSTIBLE SIDING ON TYVEK BUILDING WRAP ON Y2" FIRE CODE RATED SHEATHING ON Y2" PLYWOOD SHEATHING. P-6" O.H. CLASS W R -. F. 22GA 1Y" CORRUGAT ED COLD ROLLED STEEL RO ING ON VERSASHI ' UNDERLAY1 IENT ON ICE '+ WATER SHIIFUD ON %" PLYWOOD <jECK. C CHANNEL ASCIA PER PLAN W/ DRIPEDGE. SYe" ABOVE VALL Y BEAM TOS ELEVATION. 'IE^yCi1A:l. G. TWR EAVE + INSULATION A4 Scale: 1 = V-0 ON i . 1X NON-COMBUSTIBLE SIDING ON Y2" FIRE CODE RATED SHEATHING ON TYVEK BUILDING WRAP Y2" PLYWOOD SHEATHIN EXPOSED GALVANIZED DECKING. 4 SHED RF EAVE + INSLTN A4 Scale: 1 = V-0 2X NON -CO MBUSTIBLE SOFFIT EN NON -COMB D CAP W/ 1 X USTIBLE __ SOFFITBOARDS.ONY2" FIRE CODE SHEATHING. VENT SOFFIT BOX. 6" STEEL STUD WALL ON TOP OF STEEL BEAM TO BOTTOM OF %8" PLYWOOD. Imo --SEE WALL INSULATIO DETAIL FOR N + INTERIOR FINISH. Phase II Phase I Phase II Phase I A/A S-10 POMA ROOF TERMINAL EXTENT Upp6r-1evel Floor Plan SCALE: Ya" = V-0 553.92 SF 1 0 2 d 8/B S 10 GCS 10 Terminal SCALE: Ya" = 1'-0 1 o z d NA S-10 — __J Phase I 1-6" A -A £-10 _T Phase II Phase N V_ d' N 0 W N� rnp O J O � CL U W ■ T z U Wd ry QX QJ m U) 0Q a- m O Q D_ Y O o �I U z W L/ L.1_ LLI z > Q Q + LL C/) o 0� W LL + U z O O p O w Q LL- > J z - W Z D_ z W a W J j jL �7 Q O 0- (� O O 000 o -i D w Z z U_ I— 0 (5 8 PeEET Stla.n-r 140 %A1r1.A#4 E 2 3 1E! C! 5 6 i N 0 T I., P I:fF PROPERTY BOUNDARY LOT 10 SEC. 4 NEW BUILDING & LOADING DECK ADDITIOI PRIMARY ROAD ACCESS UP I+ TRANSFER , _ TRAIL, ALM. CAP /VW1/4SW1/4 ' SEC.3 .- "' APPROXIMATE - EDGE OF CLIFF BOUNDARY PROPERTY • r, ONORTHPLAN SCALE: 1 20'-0 40 ALPINE COASTER SHOOTING GALLERY BLDG. YURT 15'R Covered Stage Ferris Wheel ygp d 1 I '-�d; { >Z N a) acro— ' m a cif N N ! Ui `a NMro IIIIII mod/ W I I LL �ti W Nj0'� 00 R Ci q' ..4 q f to %l LU Q �E I0 Zi e¢ C fD W: iL J� W t co tj pi -- Extent of Building New Maini to t= Addition. Building/Storage , = e i Gp I, 1^• j �t73 O pi - \ Extent of Gondola �% , Maze _ ng Terminal Roof Above Deck Loadi G - >. _lie { and . a dad d a..0 da a \ W 7 B 1. - -. a a .y U) Visitor Center / Restaurant a < I Va f0 0) V � � a 0 0 d M \\ k C \ a a n ((I0n Q O O _ A a e d i'. d l Children , end FoSsl(_Dig ,ter .' a- 4 a r a' ✓ � R C I s t t'�� a V� ° `A Vi off, ai- aa a t ...... T a aab` a d C ° d<a 6°d " .,. .... �. d LL rn \ 9 '. n . 'S.'. a da a --......__..._ ....,.�,^, .q G .. < a a' y„ -_ <....-._h-w - ._.,... d a •\. a a -la _ rb M \ x• .a ..,.. a :. knee a ° c+� O to a r�Y i Y"=. t o F�� 6 G' q -✓"ter+ „ 4 . .. a a`^.,.. r' ( m Z d w o ; IL na 4 BUILDING SITE PLAN da. a ®PLAN SCALE: 1° = 20'-0 NORTH N ono zo 4" a -A 1 2 3 3 L; A 0 3 0 5 C� MATCH SIZE AND SPACING OF HORZ. WALL REINF. - 2" CLEAR TYP. @ CORNER BAR - HORIZ. WALL REINF. (SEE WALL SECTIONS) BAR SIZE LAP (CONCRETE) LAP (MASONRY) 43 THRU #6 36x BAR 0 (18" MIN.) 40x BAR 0 #7 THRU #9 40x BAR 0 48x BAR 0 #10 THRU #11 54x BAR 0 -REINFORCING PER PLAN Y4° SAW CUT CONTROL JOINT A REINFORCEMENT AT CORNER LAP FrtaleV9" e 9'11 NOTES: 1. SLABS SHALL BE CAST IN STRIPS 16-0" WIDE MAXIMUM WITH CONSTRUCTION JOINTS OR CONTROL JOINTS AT A SPACING EQUAL TO THE STRIP WIDTH. 2. SAWCUT CONTROL JOINTS MAY BE USED IN BOTH DIRECTIONS SPACED AT 15-0" MAX. 3. SAWCUT JOINTS SHALL BE MADE SAME DAY AS POUR AND AS EARLY AS POSSIBLE PRIOR TO DRYING SHRINKAGE. THE JOINT SHALL BE FLUSHED WITH WATER OR AIR PRESSURE IMMEDIATELY AFTER SAWING. 4.FINISHING OF CONCRETE SLAB SHALL BE DONE AFTER SURFACE BLEED WATER HAS EVAPORATED. 5. MOISTEN SUB -GRADE PRIOR TO PLACING CONCRETE (IF APPLICABLE). 6. APPLY MEMBRANE CURING COMPOUND TO CONCRETE IMMEDIATELY AFTER CONCRETE FINISHING OPERATION. 7. VERIFY SAW CUTS WILL NOT DAMAGE IN SLAB RADIANT HEATING. Phasing Phase I (Winter 2018-2019): Completion of All Foundation Work and Steel Installation. Complete Metal Decking Installation and Concrete Floor Slabs. New Tram Loading Deck to be Completed in it's entirety. New Electrical Room to be Framed with Lift Drive Equipment Installed. Phase 11 (Fall 2019): Completion of Grip Bay, Storage Area and Offices. To Include All MEP Exterior Framing and Interior Finishes. GENERAL NOTES 1. DESIGN DATA: DESIGN LIVE AND DEAD LOADS ROOF LOAD L.L. = 50 PSF (SNOW) D.L. = 10 PSF FLOOR LOAD L.L. = 125 PSF D.L. = 67 PSF UPPER GRIP BAY L.L. = 100 PSF D.L. = 10 PSF DECK LOAD L.L. = 100 PSF D.L. = 67 PSF WIND LOAD 80 MPH (@ 40 HEIGHT) EXPOSURE C 2 THE FOLLOWING CODES AND EDITIONS WHERE USED - INTERNATIONAL BUILDING CODE (2015) - ACI BUILDING CODE (ACI 318-02) - MANUAL OF STEEL CONSTRUCTION (9TH EDITION) 3. THE CONTRACTOR SHALL ASSUME SOLE AND COMPLETE RESPONSIBILITY FOR JOB SITE CONDITIONS DURING THE COURSE OF CONSTRUCTION, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY, AND THIS REQUIREMENT SHALL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. 4. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS OF CONSTRUCTION INCLUDING, BUT NOT LIMITED TO, SHORING, BRACING, AND TEMPORARY EXCAVATION. 5. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND SITES CONDITIONS BEFORE STARTING WORK AND NOTIFY THE ARCHITECT AND ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. 6. ALL OMISSIONS AND CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH WORK SO INVOLVED. 7. RESOLVE ANY CONFLICTS ON THE DRAWINGS WITH THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. 8. COORDINATE ALL OPENINGS THROUGH FLOORS, WALLS AND ROOF WITH THE APPROPRIATE TRADES. NOTIFY ENGINEER IF ANY OPENINGS ARE TO BE CUT IN STRUCTURAL COMPONENTS. FOUNDATION AND EARTHWORK 1. DESIGN BASED RECOMMENDATIONS CONTAINED IN A GEOTECHNICAL REPORT PREPARED BY HP KUMAR (JOB 18-7435) DESIGN MAX. BEARING PRESSURE - 3000 PSF NO EXPANSIVE OR COLLAPSIBLE SOILS WERE ANTICIPATED ASSUMED LATERAL EARTH PRESSURE: 50 PCF. THE CONTRACTOR SHALL REVIEW THE SOILS REPORT AND FOLLOW ALL RECOMMENDATIONS THEREIN. FOUNDATION DESIGN ASSUMES THAT ALL RECOMMENDATIONS IN THE SOILS REPORT WILL BE IMPLEMENTED. 2. MINIMUM DEPTH TO BOTTOM OF FOOTING SHALL BE 3' BELOW LOWEST ADJACENT FINISHED GRADE FOR EXTERIOR FOOTINGS AND V-0" BELOW FINISHED FLOOR FOR INTERIOR FOOTINGS U.N.O. 3. ALL INTERIOR NON -BEARING, NON -SHEAR WALLS SHALL HAVE ITT PHILLIPS #81509, #12883, OR #22093 SHOT PINS @ 32" o.c. INSTALLED PER 1CBO #1280. 4. FINISHED EXCAVATION FOR FOUNDATION SHALL BE NEAT AND TRUE TO LINE WITH ALL LOOSE MATERIAL AND STANDING WATER REMOVED FROM EXCAVATIONS. 5. THE GROUND SURFACE SURROUNDING THE EXTERIOR OF THE BUILDING SHOULD BE SLOPED TO DRAIN AWAY FROM THE FOUNDATION IN ALL DIRECTIONS. IT IS RECOMMENDED THAT A MINIMUM SLOPE OF 12 INCHES IN THE FIRST 10 FEET IN UNPAVED AREAS, AND A MINIMUM SLOPE OF 3 INCHES IN THE FIRST 10 FEET IN PAVED AREAS BE PROVIDED. INSTALL FOUNDATION DRAINS AS REQUIRED BY SOILS REPORT. 1. CONCRETE WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 301, SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS. MINIMUM STRENGTH: F'c = 4,500 PSI AT 28 DAYS ALL CONCRETE USED IN SLABS SHALL CONTAIN 1-1/2 LB/CY OF COLLATED, FIBRILLATED POLYPROPYLENE FIBERS (FIBERMESH) w/ 7% AIR ENTRAINMENT SLUMP: 4" t 1" NO WATER SHALL BE ADDED ON SITE WHICH WILL INCREASE SLUMP TO ABOVE 511. CONCRETE TO BE MIXED PER ASTM C94 MAXIMUM TEMPERATURE IN MIXER: 90 DEGREES F. 2. CURING SHALL IMMEDIATELY FOLLOW THE FINISH OPERATION. KEEP CONCRETE CONTINUOUSLY MOIST FOR AT LEAST 7 DAYS USING A POLYETHYLENE FILM SECURELY HELD IN PLACE OR AN ALTERNATE METHOD APPROVED BY ARCHITECT. 3. PLACE ENT: PER A STANDARD 614 3.� c�,rNR �'aPcazPiii. f 4. ROUT UNDER COLUMN BASE PLATE ETC, WITH HIGH STRENGTH, NON -SHRINK, NON-METALLIC GROUT EQUIVALENT TO MASTERFLOW NO. 713 APPLIED PER MANUFACTURER'S RECOMMENDATIONS. 5. CEMENT SHALL BE PER ASTM C150, TYPEIi, LOW ALKALI. MIX DESIGNS: IF REQUESTED, SUBMIT TO ARCHITECT FOR REVIEW BY ENGINEER A MINIMUM OF ONE WEEK PRIOR TO FIRST CONCRETE DELIVERY. MAXIMUM WATER/CEMENT RATIO(BY WEIGHT) :W/c = 0.64 F'c = 3000 PSI AGGREGATE: PER ASTM C33, MAXIMUM V. NO ADMIXTURES CONTAINING CHLORIDE SALTS ARE PERMITTED. CONCRETE SHALL NOT BE IN CONTACT WITH ALUMINUM. REINFORCING STEEL 1. REBARS: DEFORMED STEEL, ASTM SPEC. A615 GRADE 60. ALL REBAR BENDS TO BE MADE COLD. 2. BURLAP: CONCRETE: 40 DIA. U.N.O. MASONRY: 45 DIA, U.N.D. OR 24" MINIMUM WHICHEVER IS GREATER. STAGGER SPLICES 3. CONCRETE PROTECTION: SLABS AND WALLS NOT EXPOSED TO EARTH OR WEATHER .......1" CONCRETE DEPOSITED AGAINST EARTH WITHOUT FORMS .........3" 4. CONCRETE EXPOSED TO WEATHER AFTER FORMING: #6 REBAR AND LARGER ........ 2" CLEAR #5 REBAR AND SMALLER ....... 1 112" CLEAR 5. REINFORCING IN CONCRETE PLACED AGAINST EARTH WITHOUT FORMS IS TO BE SUPPORTED WITH APPROVED NON-METALLIC CHAIRS, OR ANOTHER METHOD APPROVED BY THE ENGINEER. STRUCTURAL STEEL 1. ROLLED SHAPES AND PLATES: PER ASTM SPEC. A36, Py = 36 ksi PIPES: PER ASTM SPEC. A501, Py = 36 ksi STRUCTURAL TUBING: PER ASTM SPEC, A500, GRADE B, F'y = 46 ksi ANCHOR BOLTS: PER ASTM SPEC. A307 BOLTS WOOD CONNECTIONS: PER ASTM A307 BOLTS AT STEEL CONNECTIONS: PER ASTM A325 BOLT HOLES 1/16" GREATER THAN BOLT SIZE. ACCEPT FOR ANCHOR BOLTS WHICH ARE 3116" GREATER THAN BOLT SIZE. U.N.O. 2. WELDING PER STANDARDS OF AMERICAN WELDING SOCIETY. ELECTRODES AWS A 5.1 E-70 SERIES. SHOP AND FIELD WELDING SHALL BE PERFORMED BY PROPERLY CERTIFIED WELDERS. 3. PAINT ALL STRUCTURAL STEEL WITH TWO SHOP COAT PRIMER OVER CLEAN METAL. 4. COPES, BLOCK AND CUTS: ALL REENTRANT CORNERS SHALL BE SHAPED NOTCH -FREE TO A RADIUS OF AT LEAST 1/2". 5. FABRICATION AND ERECTION: PER AISC MANUAL OF STEEL CONSTRUCTION DETAILING: PER AISC STRUCTURAL DETAILING 6. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR REVIEW BY ENGINEER PRIOR TO FABRICATION. EXTERIOR WALL PLYWOOD SHEATHING PLYWOOD SHEATHING SHALL BE APA GRADE -TRADEMARKED C-D, EXPOSURE 1. SHEATH ALL EXTERIOR WALLS WITH 1/2", APA RATED PLYWOOD SHEATHING, 20/0 WITH 8'-0" DIMENSION VERTICAL. BLOCK ALL EDGES. END JOINTS SHALL BE STAGGERED. STUDS SHALL BE 16" o.c. ATTACH PLYWOOD WITH 8d NAILS AT 6" o.c. AND AT INTERMEDIATE SUPPORTS WITH 8d AT 12" o.c. ROOF PLYWOOD SHEATHING PLYWOOD SHEATHING SHALL BE APA GRADE -TRADEMARKED C-D, EXPOSURE 1. ROOF DIAPHRAGMS SHALL BE 518", APA RATED SHEATHING, 40/20 PLACED WITH 8'4" DIMENSION PERPENDICULAR TO THE JOIST, RAFTER OR TRUSS SPAN. END JOINTS SHALL BE STAGGERED. ATTACH PLYWOOD AT EDGES WITH 8d NAILS AT 6" o.c. AND AT INTERMEDIATE SUPPORTS WITH 8d NAILS AT 12" o.c. SHEATHING SHALL BE T & G OR PROVIDE PLYCLIPS MIDWAY BETWEEN RAFTERS AT UNSUPPORTED EDGES. 1191�1 U) w co a) z l m _O i U � (1)f° N rY LL _ -E c W U W a W i N .- of 'U 00 N N N C T 0 tf5 C E L F- t6 E c6 L 1- L CL CL Z) W N cc a W v LliU of U Z rn W U .r rn uO m � r C v 0 o ti m o eo I- W � n O j LIA F" O I d O G c tl) N Q s� c O L +- N 07 > M 3 U C O O m O C N o0 Q oM A O N S� f17 In O (7 rn V) LL u oW M xo� Q0ln 4 d LU � a: (9 � 2 3 /10 4 MECHANICAL GENERAL NOTES: 1. DRAWING IS DIAGRAMMATIC IN NATURE. LOCATIONS AND SIZES MAY VARY DURING FIELD COORDINATION & INSTALLATION OF MECHANICAL, PLUMBING, & ELECTRICAL. DRAWINGS DO NOT NECESSARILY INDICATE EVERY REQUIRED OFFSET, FITTING, ETC. DRAWINGS ARE NOT TO BE SCALED FOR DIMENSIONS. TAKE ALL DIMENSIONS FROM ARCHITECTURAL DRAWINGS, CERTIFIED EQUIPMENT DRAWINGS AND FROM THE STRUCTURE ITSELF BEFORE FABRICATING ANY WORK, VERIFY ALL SPACE REQUIREMENTS COORDINATING WITH OTHER TRADES, AND INSTALL THE SYSTEMS IN THE SPACE PROVIDED WITHOUT EXTRA CHARGES TO THE OWNER. 2. DUCT DIMENSIONS DO NOT REFLECT ADDITIONAL DIMENSIONS FOR INSULATION. PROVIDE INSULATION PER IEEC CODE REQUIREMENTS. 3. ALL PLUMBING PIPES SHALL BE INSULATED PER IEEC CODE REQUIREMENTS. MECHANICAL / PLUMBING - UPPER TERMINAL LOWER LEVEL SCALE: 1 /8"=1'-0" ►�C ■ NORTH MECHANICAL / PLUMBING - UPPER TERMINAL MAIN LEVEL SCALE: 1 /8"=1 '-0" haw �u-i I E'VISI `S .A 00 NOT REPRODUCE THESE DRAWINGS AND SPECIRWONS WITHOUT THE EXPRESSED WRITTEN PERMISSION OF THE DESIGNER. THE DRAWINGS AND SPECIFIC MNS ARE INSIRUMENR OF THE SERWCE AND SHALL REMAIN THE PROPERTY OF THE DESIGNER WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXEDI.FED OR NOT. THESE DRAWINGS AND SPECIFlCTIONS SH NOT BE USED BY ANYONE ON ANY OTHER PRWECR FOR AODRIONS TO THIS W IZT BY OTHERS EXCEPT BY THE EXPRESSED WRITTEN PERMISSION OF THE DESIGNER U I� 410 U W •bD bQ W 00 W �()oI Q cd "a ti •�bj W IG m G'J 0.1 . --I Q � CK7 W U r W w oQ o° N DATE: ISSUED FOR: 2/8/19 FINAL REVIEW DATE: 2/04/19 JOB NO: 18-101 DRAWN BY: BCE CHECKED BY: BCE AS SHOWN SHEET NUMBER: MP1-1 ruary 22, 'ZUIS :Z/:SUom MECHANICAL PROVISIONS Hw1foloW MK#lla,J16= A. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIALS, AND LABOR TO SATISFY A COMPLETE WORKING SYSTEM WHETHER SPECIFIED OR IMPLIED, B. ALL WORK IS TO BE PERFORMED IN STRICT COMPLIANCE WITH ALL LOCAL CODES AND ALL OTHER REGULATION GOVERNING WORK OF THIS NATURE. C. THE CONTRACTOR SHALL, BEFORE SUBMITTING ANY PROPOSAL, EXAMINE THE PROPOSED SITE AND SHALL DETERMINE FOR HIMSELF THE CONDITIONS THAT MAY EFFECT THE WORK. NO ALLOWANCE SHALL BE MADE IF THE CONTRACTOR FAILS TO MAKE SUCH EXAMINATIONS. D. ALL EQUIPMENT AND MATERIALS SHALL BE AS SPECIFIED OR "APPROVED EQUAL" BY THE ENGINEER OR ARCHITECT. 2. PERMITS A. THE CONTRACTOR SHALL SECURE ALL PERMITS OR APPLICATIONS AND PAY ANY AND ALL FEES. 3. SHOP DRAWINGS A. SUBMIT MATERIAL LIST AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE ACHITECT/ENGINEER FOR APPROVAL. THE CONTRACTOR SHALL SUBMIT FIVE SETS OF SHOP DRAWINGS AND THEY SHALL BE CLEARLY LABELED. 4. FLEXIBLE DUCT WORK A. FLEXIBLE TYPE DUCT SHALL BE OF TWO ELEMENT SPIRAL CONSTRUCTION COMPOSED OF A CORROSION RESISTANT METAL SUPPORTING SPIRAL AND COATED FABRIC WITH A MINERAL BASE. FLEXIBLE DUCT CONNECTORS SHALL BE LISTED BY U.L., CLASS 1 DUCTS, AND SHALL HAVE A FLAME SPREAD RATING NOT EXCEEDING 25 AND A SMOKE DEVELOPED RATING NOT EXCEEDING 50. B. USE OF FLEXIBLE DUCTWORK SHALL BE LIMITED TO NO MORE THAN 6 LINEAR FEET PER RUN. C. CONTRACTOR SHALL BE CAREFUL SO AS NOT TO KINK OR COLLAPSE FLEXIBLE DUCT. 5. REFRIGERENT A. PIPING CONTRACTOR SHALL PROVIDE AND INSTALL REFRIGERANT PIPING IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND IN SUCH A WAY AS TO BE INCONSPICIOUS AND FREE FROM ANY POSSIBLE CONDENSATION. B. INSULATE REFRIGERANT LINES WITH ARMOUR -FLEX TYPE INSULATION, SHALL BE TYPE "K" COPPER TUBING, WITH WROUGHT COPPER SOLDER TYPE FITTINGS SUITABLE FOR CONNECTION WITH SILVER SOLDER. 6. DUCTWORK A. THE DUCTWORK SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE "SMACNA" APPLICABLE MANUALS. B. ALL DUCTWORK SHALL BE THE LOW VELOCITY TYPE, UNLESS SPECIFIED OTHERWISE. C. CONTRACTOR SHALL PROVIDE AND INSTALL APPROVED FIRE DAMPERS AND ACCESS PANELS IN ANY AND ALL DUCTWORK WHICH PENETRATES A HORIZONTAL OR VERTICAL FIRE PARTITION, OR AS OTHERWISE SHOWN ON DRAWINGS. D. ALL BRANCH DUCTS TO HAVE VOLUME DAMPERS, SMOOTH TURN RADIUS DUCTWORK OR TURNING VANES SHALL BE USED THROUGHOUT WHERE FLOW EXCEEDS 150 CFM. E. ALL DUCT JOINTS TO BE SEALED IN ACCORDANCE WITH "SMACNA" STANDARDS AND ACCEPTED GOOD PRACTICE. F. ALL DUCT DIMENSIONS SHOWN ARE NET INSIDE VALUES.DIMENSIONS MAY BE CHANGED SO LONG AS THE NET FREE FACE AREA IS MAINTAINED. G. ALL CONCEALED DUCTWORK SHALL BE INSULATED WITH 1-1/2" FIBERGLASS INSULATING BLANKET WITH ALUMINUM FOIL FACING. H. ALL SUPPLY AND RETURN DUCTWORK 15 FEET DOWNSTREAM OF THE HVAC UNIT SHALL BE INTERNALLY LINED WITH A 1/2" ACOUSTICAL DUCT LINER UNLESS OTHERWISE NOTED ON THE DRAWINGS. 7. DRAINAGE PIPING A. (CONDENSATE) SHALL BE SCHEDULE 40 PVC PIPE WITH SOLVENT JOINTS. PITCH HORIZONTAL LINES 1" IN 10'-0". CONDENSATE DRAINS SHALL BE ROUTED TO FLOOR DRAIN, ROOF DRAIN OR INDIRECT WASTE DRAIN. 8. HVAC CONTROLS A. CONTRACTOR TO SUPPLY AND INSTALL ALL CONTROL WIRING AND THERMOSTATS AS REQUIRED. 9. ELECTRICAL A. CONTRACTOR TO COORDINATE WITH ELECTRICAL CONTRACTOR FOR LOCATION OF WIRING FOR EACH HVAC UNIT. 10. PIPE SUPPORTS A. ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE IN A NEAT AND WORKMANLIKE MANNER. THE USE OF WIRE OR METAL STRAP TO SUPPORT PIPES WILL NOT BE PERMITTED. SPACING OF PIPE SUPPORTS SHALL NOT EXCEED 8 FEET FOR ALL PIPING. PLASTIC PIPING TO BE SUPPORTED EVERY 4 FEET. 11. GAS PIPING A. PIPING SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH MALLEABLE IRON FITTINGS. WHERE GAS PIPE CONNECTS TO EQUIPMENT, IT SHALL BE PROVIDED WITH A DRIP LEG THE FULL SIZE OF THE RUNOUT, A 100% SHUT-OFF VALVE AND A UNION. GAS PIPING CONTAINING PRESSURE GREATER THAN 9" W.G. SHALL BE SCHEDULE 40 BLACK STEEL PIPE WITH WELDED JOINTS. 12. MISCELLANEOUS A. ALL EXTERIOR OPENINGS TO BE PROPERLY CAULKED AND SEALED WITH A SEALANT OF HIGH QUALITY AND LONG LIFE, TO PREVENT INFILTRATION OF OUTSIDE AIR INTO CONDITIONED SPACE. COORDINATE INSTALLATION OF ALL ROOF FLASHING AT ROOF PENETRATION. B. DO NOT SCALE THIS DRAWING FOR EXACT DIMENSIONS. C. VERIFY ALL FIGURES, CONDITIONS, AND DIMENSIONS AT THE JOB SITE. D. THE MECHANICAL PLANS ARE INTENDED TO BE DIAGRAMMATIC AND ARE BASED ON ONE MANUFACTURE'S EQUIPMENT. THEY ARE NOT INTENDED TO SHOW EVERY ITEM IN ITS EXACT LOCATION, THE EXACT DIMENSIONS, OR ALL THE DETAILS OF THE EQUIPMENT. E. THE CONTRACTOR SHALL VERIFY THE ACTUAL DIMENSIONS OF THE EQUIPMENT PROPOSED TO ENSURE THAT THE EQUIPMENT WILL FIT IN THE AVAILABLE SPACE. 13. TESTING AND BALANCING A. THE HVAC SYSTEM SHALL BE TESTED AND AND BALANCED BY AN INDEPENDENT AGENCY, UNDER THE SUPERVISION OF A LICENSED PROFESSIONAL ENGINEER. A SEALED TYPE WRITTEN REPORT SHALL BE SUBMITTED TO THE ARCHITECT/ENGINEER FOR REVIEW AND APPROVAL. 14, GUARANTEE A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE(1) YEAR FROM DATE OF ACCEPTANCE. DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THIS CONTRACTOR'S EXPENSE. B. FOR THE SAME PERIOD, THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND/OR INSTALLED BY HIM. PLUMBING SPECIFICATION 1. SCOPE OF WORK A. THE CONTRACTOR IS RESPONSIBLE FOR ALL WORK, MATERIALS, AND LABOR TO SATISFY A COMPLETE WORKING SYSTEM WHETHER SPECIFIED OR IMPLIED. B. ALL WORK IS TO BE PREFORMED IN STRICT COMPLIANCE WITH THE INTERNATIONAL PLUMBING CODE (LATEST EDITION), ALL LOCAL CODES AND ALL OTHER REGULATION GOVERNING WORK OF THIS NATURE. C. THE CONTRACTOR SHALL, BEFORE SUBMITTING ANY PROPOSAL, EXAMINE THE PROPOSED SITE AND SHALL DETERMINE FOR HIMSELF THE CONDITIONS THAT MAY AFFECT THE WORK, NO ALLOWANCE SHALL BE MADE IF THE CONTRACTOR FAILS TO MAKE SUCH EXAMINATIONS. D. ALL EQUIPMENT AND MATERIALS SHALL BE AS SPECIFIED OR "APPROVED AS EQUAL" BY THE ENGINEER OR ARCHITECT. 2. PERMITS A. THE CONTRACTOR SHALL SECURE ALL PERMITS OR APPLICATIONS AND PAY ANY AND ALL FEES. 3. SHOP DRAWINGS A. SUBMIT MATERIAL LIST AND SHOP DRAWINGS FOR MAJOR EQUIPMENT TO THE ARCHITECT/ENGINEER FOR APPROVAL. THE CONTRACTOR SHALL SUBMIT FIVE SETS OF SHOP DRAWINGS AND THEY SHALL BE CLEARLY LABELED. 4. DOMESTIC WATER SUPPLY PIPING A. UNDERGROUND: PROVIDE TYPE "K" SOFT DRAWN COPPER TUBING WITH BRAZED CONNECTIONS. B. ABOVE GROUND: PROVIDE TYPE "L" HARD DRAWN COPPER TUBING WITH 125 PSI SOLDER JOINTS, COPPER OR BRASS FITTINGS. ALL SOLDER TO BE "NO LEAD" TYPE. C. ALL HOT WATER PIPING TO BE INSULATED WITH 1" FIBERGLASS INSULATION. D. ALL COLD WATER PIPING TO BE INSULATED WITH J" FOAM INSULATION. 5. SANITARY/STORM DRAINAGE AND VENT PIPING A. ABOVE GRADE: -2" BELOW: SCHEDULE 40 GALV. STEEL PIPE WITH SCREWED ENDS OR SCHEDULE 40 PVC WITH SOLVENT JOINTS OR DWV COPPER WITH SOLDER JOINTS. ALL SOLDER TO BE "NO LEAD" TYPE. -3" AND ABOVE: SERVICE WT. CAST IRON WITH NO -HUB OR BELL AND SPIGOT JOINTS; OR SCHEDULE 40 PVC WITH SOLVENT JOINTS. B. BELOW GRAD: SERVICE WT. CAST IRON WITH NO -HUB OR BELL AND SPIGOT JOINTS; OR SCHEDULE 40 PVC WITH SOLVENT JOINTS. C. PVC PIPING SHALL NOT BE USED IN AIR PLENUM CEILINGS AND SHALL NOT CROSS FIRE RATED WALLS, CEILINGS, OR FLOORS. D. DRAINAGE PIPING SHALL BE RUN AS STRAIGHT AS POSSIBLE AND SHALL HAVE LONG TURN FITTINGS. E. DRAINAGE PIPING 3" SIZE AND SMALLER SHALL RUN AT A UNIFORM GRADE OF AT LEAST I" PER FOOT. AND PIPING LARGER THAN 3" SHALL BE RUN AT A GRADE OF NO LESS THAN J" PER FOOT. F. ALL VENT PIPING SHALL BE SLOPED TO DRAIN BACK TO FIXTURES. G. CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER FLASHING OF THE VENT PIPING RUN THROUGH THE ROOF. 7. PIPE SUPPORTS A. ABOVE GRADE: ALL PIPE SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE IN A NEAT AND WORKMANLIKE MANNER. THE USE OF WIRE AND PERFORATED METAL TO SUPPORT PIPES WILL NOT BE PERMITTED. SPACING OF PIPE SUPPORTS SHALL BE A S SPECIFIED IN INTERNATIONAL PLUMBING CODE (LATEST EDITION). B. BELOW GRADE: EARTH SHALL BE EXCAVATED TO A MINIMUM DEPTH WITH AN EVEN SURFACE TO INSURE SOLID BEARING OF PIPE FOR ITS ENTIRE LENGTH. -INTERIOR: THE PIPE SHALL BE INSTALLED (UNLESS OTHERWISE SPECIFIED) A MINIMUM OF 4 INCHES BELOW THE BOTTOM OF THE SLAB AND SHALL NOT BE IN ANY DIRECT CONTACT WITH THE CONCRETE AT ANY POINT. -EXTERIOR: THE WATER PIPE SHALL HAVE A MINIMUM OF 60" OF COVER AND THE SANITARY WASTE PIPE SHALL HAVE A MINIMUM OF 24" OF COVER. B. MISCELLANEOUS A. COORDINATE INSTALLATION OF ALL ROOFS FLASHING AT ROOF PENETRATIONS. B. DO NOT SCALE THIS DRAWING FOR EXACT DIMENSIONS. VERIFY ALL FIGURES, CONDITIONS AND DIMENSIONS AT THE JOB SITE. C. THE PLUMBING PLANS ARE INTENDED TO BE DIAGRAMMATIC AND ARE BASED ON ONE MANUFACTURER'S EQUIPMENT. THEY ARE NOT INTENDED TO SHOW EVERY ITEM IN ITS EXACT LOCATION. THE EXACT DIMENSIONS OR ALL THE DETAILS OF THE EQUIPMENT. THE CONTRACTOR SHALL VERIFY THE ACTUAL DIMENSIONS OF THE EQUIPMENT PROPOSED TO ENSURE THAT THE EQUIPMENT WILL FIT THE AVAILABLE SPACE. 9. TESTING A. PLUMBING SYSTEM SHALL BE FLOW AND PRESSURE TESTED IN ACCORDANCE WITH THE INTERNATIONAL PLUMBING CODE (LATEST EDITION). 10 GUARANTEE A. MATERIALS, EQUIPMENT AND INSTALLATION SHALL BE GUARANTEED FOR A PERIOD OF ONE (1) YEAR FROM DATE OF ACCEPTANCE, DEFECTS WHICH APPEAR DURING THAT PERIOD SHALL BE CORRECTED AT THIS CONTRACTORS EXPENSE. B. FOR THE SAME PERIOD THE PLUMBING CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGE TO PREMISES CAUSED BY DEFECTS IN WORKMANSHIP OR IN THE WORK OR EQUIPMENT FURNISHED AND/OR INSTALLED BY HIM. GAS FURNACE SCHEDULE E.S.P. COOLING HEATING ELECTRICAL EQUIPMENT NO. SERVICE SUPPLY AIR (CFM) OUTSIDE AIR (CFM) (IN WG.) NOMINAL MBH GAS CFH MBH INPUT MBH OUTPUT EFFICIENCY A.F.U.E FAN HP V/PH/HZ MCA MOCP MANUFACTURER &MODEL OPTIONS/ACCESSORIES GF-1 OFFICE/STORAGE 1999 600 0.8 48 120 113 920% 91A 115/1/60 13 15 TRANE - XB90 #TUC1 D1209601A NOTE-1 NOTES: 1. PROVIDE POWER DISCONNECT, CONCENTRIC VENT KIT, CONDENSATE NEUTRALIZATION KIT, PIPE CONDENSATE TO NEAREST FLOOR DRAIN, VIBRATION ISOLATION, 4" CONCRETE HOUSEKEEPING PAD, ZONE DAMPERS WITH PROGRAMMABLE THERMOSTATS, AND HIGH ALTITUDE KIT SIZED PER LOCATION ELEVATION. GAS FIRED UNIT HEATER SCHEDULE EQUIPMENT NO. SERVICE SUPPLY AIR (CFM) HEATING GAS CONNECTION SIZE VENT OUTLET SIZE AIR INLET SIZE ELECTRICAL MANUFACTURER & MODEL OPTIONS/ACCESSORIES GAS CFH MBH INPUT MBH OUTPUT V./PH./HZ. FLA (A) MOCP (A) MOTOR HP GUH-1 GRIP BAY 629 45 37.35 1/2 4 4 120/1/60 2.4 15 0.06 REZNOR - UDAS30 NOTE-1 NOTES: 1. PROVIDE WALL MOUNTED THERMOSTAT, TOTALLY ENCLOSED FAN MOTOR, VERTICAL COMBUSTION AIR/VENT KIT, PRESSURE SWITCH CHANGE FOR ABOVE 6,000 FT, VERTICAL LOUVERS, CEILING SUSPENSION KIT, HANGER KIT FOR PIPE, MANUAL SHUTOFF VALVE, STEPDOWN TRANSFORMER (COORDINATE VOLTAGE STEPDOWN TYPE), HIGH ALTITUDE KIT SIZED PER LOCATION ELEVATION. FAN SCHEDULE MOTOR EQUIPMENT NO. SERVICE LOCATION CFM EXTERNAL STATIC PRESS (IN. W.G.) MANUFACTURER & MODEL OPTIONS/ACCESSORIES WATTS HP RPM VOLT/PH/HZ EF-1 RESTROOM CEILING 80 0.25 10.00 - 1131 120/l/60 PANASONIC - #FV-5-1 1 VK1 NOTE-1,2 EF-2 MECH. RM. CEILING 200 0.5 83.00 - 1100 120/1/60 COOK - GC-186 NOTE-1,3 F-1 GRIP RIM. CEILING 547 - 33.00 - 1650 230/l/60 AIRIUS - A-26-SP NOTE-4 NOTES: 1. PROVIDE WITH MOTOR STARTER, POWER DISCONNECT, BACKDRAFT DAMPER, VIBRATION ISOLATION, DELUXE GRILLE, TERMINATION WITH WALL CAP AND BIRD SCREEN, AND BELT DRIVEN VFD MOTOR. 2. INTERLOCK WITH LIGHT OPERATION. 3. INTERLOCK OPERATION WITH THERMOSTAT. 4. PROVIDE WITH POWER DISCONNECT, MOTOR STARTER, CEILING SURFACE MOUNTING KIT, COORDINATE COLLOR WITH OWNER, AND 0-10 VDC SPEED CONTROLLER. ELECTRIC WATER HEATER SCHEDULE EQUIPMENT NO. CAPACITY RECOVERY @ 90 DEG. F. RISE BTU/H WATER CONN. HEATING ELEMENT KW V/PH/HZ MANUFACTURER & MODEL OPTIONS/ACCESSORIES WH-1 7.1 6.8 R 3/4" 1.44 115/1/60 BOSCH - ES8 NOTE-1 NOTES: 1. PROVIDE POWER DISCONNECT, ASME PRESSURE/TEMPERATURE RELIEF VALVE PIPED FULL SIZE TO FLOOR DRAIN, KIT TO HANG FROM STRUCTURE ABOVE RESTROOM, CATCH PAN UNDERNEATH WATER HEATER. BOILER SCHEDULE INPUT OUTPUT BOILER FLUE/COMB. AIR ELECTRICAL EQUIPMENT NO. SERVICE CAPACITY CAPACITY VOLUME SIZE (INCHES) MANUFACTURER & MODEL OPTIONS/ACCESSORIES (BTUIHR.) (BTU/HR.) (GALLONS) AMPS V./PH./HZ. BL-1 BUILDING HTG 399 376 5 4" 10 120/1/60 NOTE-1 NOTES: 1. PROVIDE WITH ASME RELIEF VALVE, CSD-1 CONTROLS, CONCENTRIC VENT KIT, LOW-WATER CUTOFF WITH MANUAL RESET & TEST, FLOW SWITCH, ADJUSTABLE HIGH LIMIIT WITH MANUAL RESET, MODULATING TEMPERATURE CONTROL, CONDENSATE NEUTRALIZING KIT, HIGH ALTITUDE KIT SIZED PER LOCATION ELEVATION, AND BLOWER MOTOR. AIR COOLED CONDENSING UNIT SCHEDULE EQUIPMENT NO. SERVICE NOMINAL COOLING CAPACITY (TON) REFRIG. PIPING ELECTRIC MANUFACTURER & MODEL OPTIONS/ACESSORIES LIQUID VAPOR V/PH/HZ MOP (A) MCA (A) CU-1 GF-1 5 TON 3/8 7/8 230/l/60 50 28 TRANE - 4TTR3060D1 NOTE-1 NOTES: 1. PROVIDE WITH POWER DISCONNECT, 4" CONCRETE HOUSEKEEPING CURB, GAS FURNACE WITH MATCHING DX COOLING COIL, LINESET RECOMMENDED BY MANUFACTURER, 76 REFRIGERANT LONGEST LENGTH, ANTI -SHORT CYCLE TIMER, EVAPORATOR DEFROST CONTROL, RUBBER ISOLATOR KIT, EXTREME CONDITION MOUNTING KIT, START KIT, CRANKCASE HEATER KIT. GRILLE -REGISTER -DIFFUSER SCHEDULE EQUIPMENT NO, SIZE MODEL MANUFACTURER FINISH OPTIONS/ACCESSORIES A 10"X6" 5880 KRUEGER WHITE NOTE-1 B 20"X20" AFS580 KRUEGER WHITE NOTE-2 C 8"X6" 5880 KRUEGER WHITE NOTE-1 NOTES: COORDINATE ALL MOUNTING TYPES WITH CEILING. 1. SUPPLY AIR DIFFUSER, PROVIDE WITH AIR EQUALIZER, MANUAL DAMPER. 2. RETURN AIR GRILLE. C DO NOT REPRODUCE THESE DRAWINGS AND SPECIRGTIONS WITHOUT THE EXPRESSED WROTEN PERMISSION OF THE DESIGNER. SPECFICXMNS ARE ] S UMENTS THE DRAWINGS AND OF THE SERVILE AND SHALL REMAIN THE PROPERTY OF THE DESIGNER WHETHER THE PROTECT FOR WHICH THEY ARE MODE IS EXECUTED OR NOT. THESE DRAWINGS AND SPECIPCARONS SHAH NOT BE USED BY ANYONE ON ANY OTHER P ECTS MR AODMONS TO THIS PROJECT BY OTHERS EXCEPT BY THE EXPRESSED WRITTEN PERMISSION OF THE OESICNM Po U i-� N rA OA � •� w b�A � W cc a°i S~ O o W ITJ U 00 U � O m T--I Q O 00 Wo W T l T� �v w O Q Oo U 00 N rDATF FisSUED FOR: 2/8/19 FINAL REVIEW DATE: 2/04/19 JOB NO: 18-101 DRAWN BY: BCE CHECKED BY: BCE SCALE: S SHOWN MP1-3 P7,Y Lfiyp_y Z, 101 9:2/:51 am GENERAL TUBING NOTES: SNOWMELT TUBING IS 5/8" HEATPEX SPACING IS 10" OC TEMPERATURE DROP=30'F SUPPLY=1407 DENSITY=125 BTUH/FT2 SURFACE TEMPERATURE=37'F SOLUTION IS 50% PG. PROVIDE A MINIMUM R-10 INSULATION UNDER SNOWMELT SLAB. MANIFOLD SNOWMELT LOOP, TYPICAL MANIFOLD SNOWMELT LOOP, TYPICAL PUMP SCHEDULE EQUIPMENT NO. SERVICE LOCATION GPM HEAD (FT.) MOTOR MANUFACTURER $ MODEL OPTIONS/ACCESSORIES WATTS RPM V./PH./HZ. HP I AMPS CP-1 BOILER CIRCULATION BASEMENT 27 20 500 240/1/60 1 8 PER MANUFACTURER NOTE-1 CP-2 HYDRONIC LOOP CIRCULATION BASEMENT 27 20 500 VES I 240/1/60 1 8 TACO - VR15-3 NOTE-2 CP-3 SNOWMELT CIRCULATION BASEMENT 16 25 500 VAR1 240/1/60 1 8 TACO - VR15-3 NOTE-2 NOTES: 1. CIRCULATION PROVIDED BY MANUFACTURER. CONTRACTOR TO VERIFY/PROVIDE PUMP WITH POWERED CONVINIENCE OUTLET, POWER DISCONNECT, ADDITIONAL ACCESSORIES FROM MANUFACTURER. 2. PROVIDE WITH POWER DISCONNECT, FLANGED CONNECTIONS, CAST IRON CASING, STAINLESS STEEL IMPELLER, STAINLESS STEEL SHAFT. SNOWMELT SENSOR .T MANIFOLD SNOWMELT LOOP, TYPICAL SEQUENCE OF OPERATION: \I- ON A CALL FOR HEATING FROM ANY ZONE THERMOSTAT, THE SYSTEM PUMP CP-2 SHALL START AND THE BOILER CONTROL SYSTEM SHALL BE ENABLED TO FIRE AND SEQUENCE THE BOILERS. CP-3 SHALL RECEIVE A DEMAND SIGNAL WHICH WILL ALLOW IT TO START OPERATION AND MAINTAIN SNOWMELT TEMPERATURE. THE BOILER CONTROL SYSTEM SHALL CONTROL THE FIRING AND SEQUENCING OF THE BOILERS. THE CONTROLS SHALL MONITOR OUTSIDE AIR, HOT WATER SUPPLY AND HOT WATER RETURN TEMPERATURES. THE BOILER CONTROLS SHALL START/STOP THE INDIVIDUAL BOILER CIRCULATION PUMPS CP-1. SNOWMELT SENSORS SHALL ACTIVATE CONTROL ZONE VALVES AT EACH ZONE MANIFOLD TO MAINTAIN SPACE TEMPERATURE. 2 AIR VENT 90' CP 2 2° AIR SEPARATOR HX 3P 2"-7 I11 1 _tiE -4,500 SQF OF SNOWMELT 1/2° b TACO HEAT EXCHANGER 642 MBH. MODEL TBBOX90 OR EQUAL 2-1/2" AIR VENT T SIDE FLOW= 48.9 GPM, 30% GLYCOL COLD SIDE FLOW= 5233 GPM, 50% GLYCOL EXPANSION TANK TO DRAIN ,2" S,Yuu ......,.� DUILUIIV 1 IC� 1 IINU OUILLK 1 II IP YV Ut I AIL SNOWMELT ELT CAN BE Y ADDED SCALE: NTS NOTE: FINAL FILL OF SYSTEM SHALL BE 30% PROPYLENE GLYCOL ON BOILER SIDE, 50% ON (SNOWMELT SIDE OF SYSTEM. WIRE TIE CONNECTED TO WIRE MESH OR REBAR 5/8"0 WIRSBO TUBING 10" O.C. RADIANT SN ECOFOIL-UNDER CONCRETE BUBBLE INSULATION CONCRETE SLAB #4 REBAR AT 12" C/C 2-DIRECTIONS ECOFOIL-UNDER CONCRETE BUBBLE INSULATION METAL DECK 8" FOAM RIGID INSULATION MELT AT METAL DECK SCALE: NTS DO NOT REPRODUCE THESE DRAWINGS AND SPECIFICATIONS WTTHOIR THE EXPRESSED WRITTEN PERMISSION OF TIE DESIGNER. THE DRAWINGS MD SPECIFlGTOHS ARE INSTRUMENS OF TIE SERVICE OHO SHALL REMAIN THE PROPER OF THE DESIGNER WHETHER THE PROJECT FOR WHICH THEY ARE MADE IS EXECUTED OR NOT. THESE DRAWINGS AND SPECIFICATONS SHNJ. HOT BE USED BY ANYONE ON ANY OTHER PRPIEDS FOR A➢OITIONS TO THIS PROJECT BY OTHERS EXCEPT BY THE EXPRESSED WRRTEN PERMISSION OF THE DESIGNER. Oa U H f--I dp N W � • v T—yi C'3 x�N U�. O O O •� N �O � m C7 G4 00 T-� 00 , l �/ Qw� W Wo V Ch O O w N rDATE FISSIJEDFOR: 2 8/19 FINAL REVIEW DATE: 2/04/19 JOB NO: 18-101 DRAWN BY: BCE CHECKED BY: BCE SC SHOWN ET NUMBER: MP1-5 February 22, 2019 — 9:27:52am