HomeMy WebLinkAboutPlansC / A LF C� /< COVV- C A CENTER BL LD NG V 0062 COU\TY ROAD 113 INDEX TO DRAWINGS GLE\WOOD SPR NGS COLORADO T TITLE SHEET 9 A1.1 FLOOR PLAN, ROOF PLAN A2.1 FRONT AND REAR EXTERIOR ELEVATIONS _ A2.2 RIGHT AND LEFT EXTERIOR ELEVATIONS A3.1 BUILDING SECTIONS CONDITIONS OF PERMIT A4.1 WALL SECTIONS BLCO-07-19-5874 and SEPT-07-19-5875 A4.2 ENTRY CANOPY, FUTURE HANDICAP TOILE Rudd, LLC Factory Warehouse — Building V 62 County Road 113 (Cattle Creek Road), Carbondale APPROVED SUBJECT TO NOTFM CT EXCEPTIONS & INSP' GA1?FIE:LD CovYIT BUILDING DE Y I� DATE FIELD GcpY NC) 1NSPECTSCI4 �',';1 F?CUT THESE PLA,v:7 v Si7 1) ALL WORK SHALL COMPLY WITH THE FOLLOWING: 2015 I.B.C., I.M.C., I.P.C., I. F.G.C., I.F.C., AND 2009 I. E.C.C. AS WELL AS MANUFACTURER'S INSTALLATION REQUIREMENTS. 2) REFER TO PLAN ATTACHMENTS FOR GARFIELD COUNTY'S BUILDING REQUIREMENTS AND INSPECTIONS POLICIES. 3) ALL WORK TO COMPLY WITH "COMMERCIAL LIMITED" ZONE DISTRICT REGULATIONS AS PER GARFIELD COUNTY's LAND USE & DEVELOPMENT CODE, WORK SHALL ALSO COMPLY WITH ON - SITE WASTEWATER TREATMENT SYSTEM REQUIREMENTS. 4) BUILDING APPROVED AS OCCUPANCY GROUP F-1: "MODERATE -HAZARD FACTORY INDUSTRIAL" AND CONSTRUCTION TYPE V-B. THE MAXIMUM ALLOWABLE QUANTITY OF FLAMMABLE & COMBUSTIBLE MATERIALS SHALL BE PER I.B.C., SECTIONS 413 & 414, AND THE MAXIMUM ALLOWABLE QUANTITIES OF HAZARDOUS MATERIALS PER I.B.C., TABLE 307.1(1). 5) THIS BUILDING IS APPROVED FOR CORE & SHELL CONSTRUCTION ONLY, AND ANY SUBSEQUENT TENANT IMPROVEMENTS WILL REQUIRE ADDITIONAL BUILDING PERMITS. INTERIOR PARTITION WALLS SEPARATING INDIVIDUAL TENANTS TO COMPLY WITH "FIRE PARTITION" REQUIREMENTS AS PER SECTION 708. 6) CONTACT LOCAL FIRE DISTRICT TO REVIEW I.F.C. REQUIREMENTS. FINAL APPROVAL REPORT FROM FIRE DISTRICT IS REQUIRED PRIOR TO FINAL BUILDING INSPECTION & CERTIFICATE OF OCCUPANCY. 7) OPEN -HOLE SOILS REPORT IS REQUIRED AT FOOTING INSPECTION, 2000 P.S.F. 8) WALK DOOR REQUIRED FOR EGRESS FROM EACH TENANT SPACE. PROVIDE 36" X 80" MIN. SIZE PER I.B.C., SECTION 1010.1. LOCKS, LATCHES AND LANDINGS PER I.B.C., SECTION 1008. VERIFY EXIT DIRECTIONAL SIGNAGE PRIOR TO ELECTRICAL ROUGH -IN INSPECTION. 9) ALL EGRESS DOORS SHALL MEET ICC/ANSI A117.1-2009 FOR ACCESSIBILITY. LOCKS, LATCHES & LANDINGS PER I.B.C., SECTION 1008. VERIFY EXIT DIRECTIONAL SIGNAGE PRIOR TO ELECTRICAL ROUGH -IN INSPECTION. 10) BUILDING SHALL COMPLY WITH ACCESSIBILITY REQUIREMENTS AS PER I.B.C., CHAPTER 11 & ICC/ANSI A117.1-2009, INCLUDING PARKING, SITE ACCESS, ENTRANCES AND BATHROOMS. BATHROOM FACILITIES SHALL MEET MINIMUM REQUIREMENTS FOR SIZE, FIXTURE LAYOUT, CLEARANCES, ETC. 11) BATHROOM INTERIOR FINISHES (INCLUDING FLOOR, WALLS AND BASE) SHALL HAVE A SMOOTH, HARD, NON -ABSORBENT SURFACE AND TO OTHERWISE COMPLY WITH I.B.C., SECTION 1203 "TOILET AND BATHROOM REQUIREMENTS". 12) LIGHT & VENTILATION PER I.B.C., CHAPTER 12. 13) ELECTRICAL PERMITTING & INSPECTIONS BY COLORADO STATE ELECTRICAL BOARD. ELECTRICAL ROUGH -IN APPROVAL IS REQUIRED AT FRAME INSPECTION, AND FINAL APPROVAL IS REQUIRED PRIOR TO FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. �F J Q - S� o�fl "F) `b J � � rL I ?R-k_jL-0Vj f �C(—L I!PA-k PROJECT DESCRIPTION OCCUPANCY GROUP: F-1 (MODERATE —HAZARD FACTORY INDUSTRIAL TYPE OF CONSTRUCTION: TYPE V—B� PROPOSED BUILDING AREA. UNIT V-1 800 S.F. UNIT V-2 800 S.F. UNIT V-3 800 S.F. UNIT V-4 800 S.F. TOTAL 3200 S.F. GENERAL NOTES 1. ALL WORK SHALL CONFORM WITH ALL GARFIELD COUNTY CODES AND ORDINANCES, AND THE LATEST ADOPTED EDITIONS OF THE INTERNATIONAL BUILDING CODE AND INTERNATIONAL ENERGY CONSERVATION CODE. 2. PROVIDE ENERGY STAR RATED BOILERS, FURNACES, AIR CONDITIONERS, REFRIGERATORS, STAND ALONE FREEZERS, CLOTHES WASHERS, CLOTHES DRYERS, AND DISHWASHERS. 3. ALL JOINTS, SEAMS AND PENETRATIONS THROUGH THE EXTERIOR ASSEMBLIES SHALL BE SEALED WITH AN EXTERIOR GRADE CAULK. 4. HOT WATER PIPING SHALL BE INSULATED TO R-3 MINIMUM. 5. THE MECHANICAL AND ELECTRICAL SUBCONTRACTORS SHALL VERIFY THAT THEIR DESIGNS MEET THE REQUIREMENTS OF THE ADOPTED EDITIONS OF THE IBC AND IECC. 6. EXHAUST FANS SHALL BE VENTED DIRECTLY TO THE EXTERIOR FROM ALL BATHROOMS AND WATER CLOSET ROOMS, PROVIDE GRAVITY DAMPERS MEETING THE REQUIREMENTS OF THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE AND INTERNATIONAL BUILDING CODES. 7. PROVIDE SAFETY GLAZING MEETING THE REQUIREMENTS OF IBC SECTION 2406 AT ALL EXTERIOR AND INTERIOR LOCATIONS SPECIFIED IN IBC SECTION 2406.4 INCLUDING. 8. A COMBUSTION SAFETY TEST SHALL BE PROVIDED FOR ALL VENTED APPLIANCES IN COMPLIANCE WITH GARFIELD COUNTY ORDINANCES AND THE IECC. PRIOR TO FINAL INSPECTION, THE CONTRACTOR SHALL SUBMIT A LETTER FROM THE PROJECTS APPROVED ENERGY CONSULTANT/INSPECTOR CERTIFYING A PASSING TEST. 9. A ROUGH —IN INSPECTION OF AIR BARRIERS BY A THIRD PARTY INSPECTOR SHALL BE PERFORMED PRIOR TO PLACEMENT OF INSULATION. SUBMIT A REPORT TO THE BUILDING OFFICIAL CERTIFYING COMPLIANCE WITH THE 2009 IECC. REPORT SHALL BE DUE AT TIME OF FINAL INSPECTION. THE NAME OF THE THIRD PARTY INSPECTOR SHALL BE SUBMITTED BEFORE ANY INSPECTIONS TO VERIFY THAT THE THIRD PARTY INSPECTOR MEETS GARFIELD COUNTY BUILDING QUALIFICATIONS. 10. INSTALL A PERMANENT CERTIFICATION OF INSULATION VALUES IN COMPLIANCE WITH THE 2009 IECC ON THE INSIDE OF THE ELECTRICAL PANEL DOOR. 11. BUILDING CAVITIES SHALL NOT BE USED AS SUPPLY DUCTS. 12. AT TIME OF PERMIT APPLICATION, THE CONTRACTOR SHALL SUBMIT THE NAME OF THE THIRD PARTY ENERGY CONSULTANT/INSPECTOR FOR THE GARFIELD COUNTY BUILDING DEPARTMENT'S APPROVAL OF INSPECTOR QUALIFICATIONS, 13. PRIOR TO FINAL INSPECTION , THE CONTRACTOR SHALL SUBMIT A LETTER FROM THE PROJECT's APPROVED ENERGY CONSULTANT/INSPECTOR CERTIFING THAT THE STRUCTURE WAS BUILT IN COMPLIANCE WITH THE IECC AND GARFIELD COUNTY ORDINANCES . 14. AT ALL STUD CAVITY SPACES THAT WILL BE INACCESSIBLE AT TIME OF INSULATION INSTALLATION SHALL BE FULLY INSULATED AND PROVIDED WITH A SOLID AIR BARRIER WITH ALL JOINTS SEALED PRIOR TO FRAMING FOR THE ITEMS CREATING THE INACCESSIBLE FEATURE. ACCEPTABLE INSULATION/AIR BARRIER SYSTEMS INCLUDE R-21 BATT INSULATION WITH OSB SHEATHING AIR BARRIER, OR SPRAYED FOAM INSULATION COMPLETELY FILLING THE CAVITY, OR A SYSTEM APPROVED BY THE PROJECT'S APPROVED ENERGY CONSULTANT/INSPECTOR. IN WET LOCATIONS, SUCH AS BEHIND BATH TUBS OR SHOWERS, PROVIDE A WATER RESISTANT SOLID AIR BARRIER SUCH AS "GREEN BOARD" OR CEMENT BOARD. THE INACCESSIBLE SPACE SHALL NOT BE COVERED UNTIL INSPECTED AND APPROVED BY THE PROJECTS ENERGY CONSULTANT/INSPECTOR. CEMENT BOARD SHALL BE USED AT LOCATIONS WHERE TILE WILL BE INSTALLED OVER SUBSTRATE. "GREEN BOARD" SHALL NOT BE USED AT SUCH LOCATIONS. of Coto Nil #v s `o S HARRY A. GARNER � 30,573 COPYRIGHT 2019 - GARNER ASSOCIATES, INC. 4 Y� GARNER ASSOCIATES, INCORPORATED ARCHITECTURE AND PLANNING Harry Garner Registered Architect 4181 County Road 31.1 New Catle, CO 81647 970-876-0673 CELL 970-379-8345 E-mail: garner—harry@msn.com Web site: gaiassociates.com 0 b 0ll �0} V UO VJ � Y � O rWr^ (' Vl Q N U� 0 0 W U v U REVISIONS JOB NUMBER 1902 DATE 05-15-19 DRAWN BY CHECKED BY SHEET NUMBER UT J I 20'-0" 10'-0" 5020 FIXED ALUM WINDOW 4� \ \ A4.1,' f T O I 1 4 6'-6" -OUT CFORFUTUREILET. Q AND no A4 X z LL O O O 2 UNIT V-1 UNIT V-2 0 800 SF N 800 SF A4.1 no xz U_ 0 I STEEL OVERHEAD/ 2 SECTIONAL DOOR �A22/ 3P70 H. [ „ WI M. 'A 0 MW•NI 5020 FIXED ALUM WINDOW N UNIT V-3 800 S F 10'-0" MWEV �,A4.1i SEALED 4" CONCRETE SLAB SEE STRUCTURAL /I I I I STEEL OVERHEAD 31 70 1 UL ED STEEL OVERHEAD 3P1 70 U E SECT19NAI DOOR SECTIONAL DOOR P H. . DOO H. 1 . DOO V I .M. F E W/ M. F 1 Conditions of Permit at Restrooms: 3 1 (A) BATHROOM INTERIOR I INISHES INCLUDING FLOORS, WALLS AND WALL BASES SHALL HAVE A SMOOTH, HARD, NON -ABSORBENT SURFACE AND TO OTHERWISE COMPLY WITH SECTION 1203, TOILET AND BATHROOM REQUIREMENTS. (B) BATHROOM FACILITIES TO MEET ICC/ANSI A117.1-2009 STANDARDS FOR ACCESSIBILITY INCLUDING MINIMUM SIZE, LAYOUT, CLEARANCES, FEATURES, ETC. (C) PROVIDE MECHANICAL VENTILATION & EXHAUST FAN AT BATHROOMS WITH 20 _ U INSTALLATION AND VENTING PER MANUFACTURER'S REQUIREMENTS. 1 UNIT V-4 800 SF I I� /I o / I STEED VERIHEAD SECTI AL DOOR II I o II II I WELDED STEEL TUBE CANOPY FRAME. SEE CANOPY DETAIL 2/A4.2 - ------I B 4-� C D. o cCAM 12' WIDE OVERFLOW SCUPPER TH RU PARAPET W/12"X24" CONCRETE SPLASH BLOCK BELOW. BOTTOM EDGE OF SCUPPER TO BE ROOF DRAIN EQUAL TO 1-1/2" ABOVE LOW POINT OF ZURN 2107 -4". ROOF. (TYP 4) PLUMBING DESIGNER TO VERIFY DRAIN SIZE (TYP 4) SLOPE ROOF SLOPE ROOF SLOPE ROOF SLOPE ROOF 3/8"/FT +/_ 3/8"/FT +/_ 3/8"/FT +/- 3/8"/FT +/- waLL� II w 3 II SLAPS I'� SLOPE - SLOPE I ROOF II ROOF ROOF 14=4 14"IFT (- - A:" B ROOF PLAN D�1 G kxyO►'le I+Vl �I V►tl f �j of 61 as per 90119RA06v". ELtCTRICAL PERMITTING & INSPECTIONS ARS BY THE COLORADO STATE ELECTRICAL BOARD ELECTRICAL ROUGH IN APPROVAL IS REQUIRED AT FRAMING INSPECTION ELECTRICAL FINAL APPROVAL IS REQUIRED AT CO/FINAL INSPECTION WE 00 XZ LL O CO O Nr /2 A333 0 _I 3070 INS TED H.M. OOR W/ H. ..FRAME ALL EGRESS DOORS SHALL MEET ICC/ANSI A117.1-2009 FOR ACCESSIBILITY. LOCKS, LATCHES & LANDINGS PER I.B.C., SECTION 1008. VERIFY EXIT DIRECTIONAL SIGNAGE PRIOR TO ELECTRICAL ROUGH -IN INSPECTION. FLOOR PLAN 1 /4" = I — u HARRY A. GA, GARNER ASSOCIATES, INCORPORATED ARCHrrECTURE AND PLANNING Harry Garner Registered Architect N 4181 County Road 311 New Catle, CO 81647 970-876-0673 CELL 970-379-8345 E-mail: &arner_harry@msn.com Web site: gaiassociates.com REVISIONS JOB NUMBER 1902 DATE 04-14-19 DRAWN BY CHECKED BY SHEET NUMBER o-.- A I 1/8" = 1'-0" COPYRIGHT 2019 - GARNER ASSOCIATES, INC. SINGLE CORNER BARS MAYBE USED IN WALLS LESS THAN 5'-0" IN HEIGHT. CORNER BARS TO MATCH SIZE & SPACING OF HORIZ. WALL REINF. UNO. 2" CUR. - TYP HORIZONTAL WALL REINF. (SEE DETAILS) CORNER (PLAN) INTERSECTION (PLAN) BAR SIZE LAP (CONCRETE) LAP MASONRY #3 THRU #6 36x BAR 0 (18" MIN.)l 40x BAR 0 #7 THRU #9 40x BAR 0 48x BAR 0 #10 THRU #11 54x BAR 0 TYPICAL CORNER AND INTERSECTION REINFORCEMENT 4d 2 1/2' MIN. 1 �1 D/2 \ O� r 2 HOOKS & BENDS LAP PER SCHEDULE 15" MIN. _f 1 6 BARS SHALL BE IN CONTACT & WIRED TOGETHER LAP SPLICE BAR LAP SCHEDULE BAR SIZE DIA.-CONC. #3 THRU #6 44 BAR 0 #7 THRU #9 56 BAR 0 10 THRU #11 56 BAR 0 TYPE 'A' 135" STIRRUP & TIE HOOK TYPE 'A' HOOK GRADE BEAM STIRRUP BEND DIAMETER SCHEDULE BAR SIZE BEND DIAMETER #3 THRU #5 D = 4d #6 THRU #8 D = 6d 9 THRU #11 D = 8d D= BEND 0,d=BAR D TYPICAL REINFORCEMENT DETAILS (2) #5 _ 10" (2) #5 DOWELS (2) #5 DOWELS fT.O.W. VARIES PER PLAN CONC WALL PER PLAN CONT FTG PER PLAN O X a a„ :m CONT. FTG PER PLAN z � ��Ay�1j - BEARING ON UNDISTURBED r NATURAL SOIL ALTERNATE STEP FOOTING DETIAL FOR SIZE & SPACING OF JOIST SEE PLAN BOUNDARY NAILING (B.N.) ® BOUNDARIES & CONTINUOUS PANEL EDGES INTERMEDIATE NAILING EDGE NAILING STAGGE PLYWOOD JOINT NOTES 1. PLYWOOD TO BE INSPECTED PRIOR TO COVERING. 2. STAGGER NAILS WHEN SPACING IS 2" OR 2 1/2" o.c. 3. SEE PLYWOOD SHEATHING NOTES. SHEATHING LAYOUT PLAN 1/8" EDGE DISTANCE ALL JOINTS 3/8" MIN. EDGE DISTANCE ® ALL NAILS LONG DIMENSION OF PLYWOOD TO RUN PERPENDICULAR TO JOIST MINIMUM SHEATHING PANEL SIZE TO BE 2'-0" x 4'-0" "ZIP -STRIP" H 1 REINFORCING PER PLAN "ZIP -STRIP" CONTROL JOINT t REINFORCING PER PLAN SAW CUT CONTROL JOINT TOP OF WALL TOP OF NOTES: 1. SLABS SHALL BE CAST IN STRIPS 15'-0" WIDE MAXIMUM WITH CONSTRUCTION JOINTS OR CONTROL JOINTS AT A SPACING EQUAL TO THE STRIP WIDTH. 2. SAWCUT CONTROL JOINTS MAY BE USED IN BOTH DIRECTIONS SPACED AT 15'-0" MAX. (ZIP -STRIP JOINTS MAY BE USED IN ONLY ONE DIRECTION.) 3. SAWCUT JOINTS SHALL BE MADE SAME DAY AS POUR AND AS EARLY AS POSSIBLE PRIOR TO DRYING SHRINKAGE. THE JOINT SHALL BE FLUSHED WITH WATER OR AIR PRESSURE IMMEDIATELY AFTER SAWING. 4. FINISHING OF CONCRETE SLAB SHALL BE DONE AFTER SURFACE BLEED WATER HAS EVAPORATED. 5. MOISTEN SUB -GRADE PRIOR TO PLACING CONCRETE. 6. APPLY MEMBRANE CURING COMPOUND TO CONCRETE IMMEDIATELY AFTER CONCRETE FINISHING OPERATION. TYPICAL SLAB CONTROL JOINTS (2) #5 x 4'-0" LONG 12" 12" #5 BARS TO MATCH SPACING OF HORIZ. FOOTING REINF., UNO. OF Wi 1 TOP OF FOOTING NOTE: `- SEE ALSO TYPICAL 12" 12" REINFORCEMENT f -- DETAILS 3/51.0 TYPICAL REINFORCEMENT AT WALL AND FOOTING STEP SEE ARCH'L. #3 NOSING BAR TYP. 1/2" NOSE RADIUS TYP. 12„ 24" LAP. #4 0 12" o.c. EACH WAY COMPACTED FILL #4 CONT. PER GEOTECH. TOP AND ENGINEER BOT. TYPICAL CONCRETE STAIR (2) 2x TOP PLATES. SPLICE AS REQ'D. NAIL PER NAILING SCHEDULE SHT. S1.0 10d ® 12" o.c. STAGGER (3) 16d TO HEADER FIRE BLK'G PER BUILDING CODE SLAB PER ARCH'L 2x CRIPPLES CAA 16" o.c. _4A_ HEADER PER PLAN OR (3) 2x10 TYP. (3) 2x6 VERTICAL AT (1) STUD AT INTERIOR INTERIOR NON BEARING. WALLS, % ��� (2) 2x TRIMMER EXT., (2) STUDS AT EXTERIOR (1) 2x TRIMMER INT. WALLS - UNLESS NOTED OTHERWISE TYPICAL HEADER FRAMING 1. SLAB -ON -GRADE SELECTED BY THE OWNER AT THE GROUND LEVEL HAS SOME RISK OF MOVEMENT. THE SLAB OPTION, CHOSEN AS PROVIDING SUITABLE PERFORMANCE AT A REASONABLE COST, REQUIRES SUBGRADE PREPARATION OR OVER EXCAVATION AND PLACEMENT OF STRUCTURAL FILL. REFER TO SOILS REPORT FOR SPECIFIC REQUIREMENTS. 2. MOVEMENT OF THE SLAB -ON -GRADE MAY CAUSE DAMAGE TO ANYTHING CONNECTED TO BOTH THE SLAB AND OTHER PORTIONS OF THE SUPERSTRUCTURE. ISOLATION DETAILS FOR PARTITION WALLS, PIPING, ETC. MAY BE REQUIRED. CONSULT THE APPROPRIATE DRAWINGS FOR INFORMATION. STRUCTURAL STEEL 1. WIDE FLANGE SHAPES: PER ASTM SPEC. A992, Fy = 50 ksi 2. OTHER ROLLED SHAPES AND PLATES: PER ASTM SPEC. A36, Fy = 36 ksi 3. PIPES: PER ASTM SPEC. A501, Fy = 36 ksi 4. STRUCTURAL TUBING: PER ASTM SPEC. A500, GRADE B, Fy = 46 ksi 5. ANCHOR BOLTS: PER ASTM SPEC. A307 6. BOLTS WOOD CONNECTIONS: PER ASTM SPEC. A307 7. BOLTS AT STEEL CONNECTIONS: PER ASTM SPEC. A325 8. BOLT HOLES 1/16" GREATER THAN BOLT SIZE EXCEPT FOR ANCHOR BOLT WHICH .ARE 3/16" GREATER THAN BOLT SIZE UNLESS NOTED OTHERWISE. 9. DETAILING: PER AISC STRUCTURAL DETAILING 10. SUBMIT SHOP DRAWINGS TO ARCHITECT FOR REVIEW BY ENGINEER PRIOR TO FABRICATION. THE SHOP DRAWINGS DO NOT REPLACE THE ORIGINAL CONTRACT DRAWINGS. IT IS THE CONTRACTOR'S RESPONSIBILITY TO MAKE SURE ITEMS ARE CONSTRUCTED PER ORIGINAL DRAWINGS. 11. FABRICATION AND ERECTION: PER AISC MANUAL OF STEEL CONSTRUCTION 12. WELDING PER STANDARDS OF AMERICAN WELDING SOCIETY. ELECTRODES AWS A 5.1 E-70 SERIES. SHOP AND FIELD WELDING SHALL BE PERFORMED BY WELDERS HAVE EVIDENCE OF PASSING THE AMERICAN WELDING SOCIETY STANDARD QUALIFICATIONS TEST AS DETAILED IN AWS D1.1. 13. COPES, BLOCK AND CUTS: ALL RE-ENTRANT CORNERS SHALL BE SHAPED NOTCH -FREE TO A RADIUS OF AT LEAST 1/2". 14. PAINT ALL STRUCTURAL STEEL WITH ONE SHOP COAT PRIMER OVER CLEAN METAL STRUCTURAL WOOD 1. ALL WOOD MEMBERS SHALL BE DOUGLAS-FIR, 19% MAX =INSPECTION IRKED BY A RECOGNIZED GRADING AGENCY. 2. WOOD GRADES (UNLESS NOTED OTHERWISE): REPORT (A) FOR HORIZONTAL MEMBERS: FOOTING JOIST AND RAFTERS ..... GRADE #2 BEAMS AND STRINGERS ..... GRADE #10 PSFLEDGERS ..... GRADE #1 (B) FOR VERTICAL MEMBERS: 2x4 STUDS ..... CONSTRUCTION 2x6 AND LARGER STUDS ..... GRADE #2 POSTS AND TIMBERS ... GRADE #1 2x4 AND 2x6 STUDS SHALL BE FINGER JOINTED FOR VERTICAL USE ONLY. 3. CUTTING, NOTCHING OR DRILLING OF BEAMS OR JOISTS TO BE PERMITTED ONLY AS DETAILED OR APPROVED BY THE ENGINEER. 4. UNLESS OTHERWISE SPECIFIED, ALL NAILING SHALL CONFORM TO THE LATEST EDITION OF THE I.B.C. 5. ALL NAILS SHALL BE STANDARD COMMON NAILS. 6. ALL BOLTS FOR WOOD CONNECTIONS SHALL BE A307, GRADE A. 7. ALL SILLS OR PLATES RESTING ON CONCRETE OR MASONRY SHALL BE PRESSURE TREATED DOUGLAS-FIR. 8. ANCHOR BOLTS SHALL BE PLACED 9" FROM END OF A BOARD OR FROM A NOTCH AND SPACED AT INTERVALS AS NOTED. 9. ALL BOLT HEADS AND NUTS BEARING ON WOOD SHALL HAVE STANDARD CUT WASHERS. 10. ALL BOLT HOLES IN WOOD SHALL BE DRILLED 1/32" DIAMETER LARGER THAN NORMAL BOLT DIAMETER. 11. ALL FRAMING HARDWARE SHALL BE AS MANUFACTURED BY "SIMPSON COMPANY" OR ENGINEER APPROVED EQUAL. ANY SUBSTITUTIONS WITH CUSTOM FABRICATED CONNECTORS SHALL CONFORM TO SIMPSON SPECIFICATIONS INCLUDING PLATE THICKNESS, WELDS, BEARING AREAS, SIZE AND NUMBER AND LOCATION OF NAIL/BOLT HOLES. 12. PROVIDE BLOCKING OR BRIDGING PER LATEST EDITION OF THE I.B.C. 13. TOP PLATES OF ALL WOOD STUD WALLS TO BE (2) 2x #2 (SAME WIDTH AS STUDS), UNLESS NOTED OTHERWISE. LAP 48" (MINIMUM) WITH NOT LESS THAN (6) 16d NAILS EACH LAP AND NOT MORE THAN 12" BETWEEN NAILS. 14. ADHESIVES USED FOR ANY FIELD GLUING SHALL CONFORM TO APA PERFORMANCE SPECIFICATION AFG-01. 15. ALL HEADERS SHALL BE (3) 2x10 AT 2x6 STUD WALL OR (2) 2x10 AT 2x4 STUD WALL UNLESS NOTED OTHERWISE ON PLANS. 16. PROVIDE BUILT-UP WOOD COLUMNS OF (2) 2x6 AT 2x6 STUD WALL OR (2) 2x4 AT 2x4 STUD WALL OR A MINIMUM NUMBER OF STUDS TO EQUAL SUPPORTED BEAM WIDTH UNLESS NOTED OTHERWISE ON PLANS. GLUE LAMINATED WOOD 1. MATERIALS, MANUFACTURE, AND QUALITY CONTROL FOR STRUCTURAL GLUED LAMINATED TIMBER SHALL BE IN CONFORMANCE WITH "AMERICAN LAMINATED TIMBER" AND AITC 117, "DESIGN AND MANUFACTURING'. 2. MICRO -LAM (LAMINATED VENEER LUMBER) ALLOWABLE UNIT STRESSES FOR DRY CONDITION OF USE SHALL BE: Fy = 2600 PSI F" = 285 PSI Fc = 750 PSI E = 1.9 x 106 PSI 3. ALL EXPOSED BEAMS SHALL CONFORM TO EXTERIOR EXPOSED CONDITION PER UNIFORM BUILDING CODE SECTION 2312.7. SHEATHING ROOF SHEATHING; PLYWOOD OR OSB SHEATHING SHALL BE APA GRADE -TRADEMARKED C-D, EXPOSURE 1. ROOF DIAPHRAGMS SHALL BE 5/8" 40/20, APA RATED SHEATHING AT SLOPING ROOFS AND 3/4" 48/24 RATED SHEATHING AT FLAT ROOFS. PLACE PANEL WITH 8'-0" DIMENSION PERPENDICULAR TO THE JOIST, RAFTER OR TRUSS SPAN. END JOINTS SHALL BE STAGGERED. ATTACH PLYWOOD AT EDGES WITH NAILS AT 6" o.c. AND AT INTERMEDIATE SUPPORTS WITH NAILS AT 12" o.c. USE 8d NAILS AT 5/8" SEHATHING AND 10d NAILS AT 3/4" SHEATHING. WALL SHEATHINt PLYWOOD OR OSB SHEATHING SHALL BE APA GRADE -TRADEMARKED C-D, EXPOSURE 1. SHEATH ALL EXTERIOR WALLS WITH 1/2", APA RATED PLYWOOD SHEATHING, 20/0 WITH B'-O" DIMENSION VERTICAL. BLOCK ALL EDGES. END JOINTS SHALL BE STAGGERED: STUDS SHALL BE 16" o.c. ATTACH PLYWOOD WITH 8d NAILS AT 6" o.c. AND AT INTERMEDIATE SUPPORTS WITH 8d AT 12" o.c. GENERAL NOTES 1. DESIGN DATA: ROOF LOAD L.L. = 40 PSF FLOOR LOAD (LIGHT STORAGE) L.L. = 125 PSF WIND LOAD 115 MPH (0 30 HEIGHT) EXPOSURE B SEISMIC DESIGN CATEGORY B 2. THE FOLLOWING CODES AND EDITIONS WHERE USED: INTERNATIONAL BUILDING CODE (2015 EDITION) ACI BUILDING CODE (ACI 318-14) AISC MANUAL OF STEEL CONSTRUCTION (13TH EDITION) NATIONAL DESIGN SPECIFICATION FOR WOOD CONSTRUCTION (NDS 2015) AITC TIMBER CONSTRUCTION MANUAL (5th EDITION) SEAC SNOW LOAD PUBLICATION 3. DO NOT BACKFILL AGAINST FOUNDATION WALLS UNTIL SLAB IS IN PLACE. 4. ANY CHANGES MADE TO ANY ONE OF THESE DRAWINGS WITH OUT CONSENT OF ODDO ENGINEERING, INC. RELIEVES ODDO ENGINEERING, INC. OF ANY LIABILITY OF THE CONSTRUCTION DOCUMENTS, 5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MEANS AND METHODS OF CONSTRUCTION INCLUDING, BUT NOT LIMITED TO SHORING, BRACING AND TEMPORARY EXCAVATION. 6. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS AND SITES CONDITIONS BEFORE STARTING WORK AND NOTIFY THE ARCHITECT AND ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. DO NOT SCALE DRAWINGS. 7. ALL OMISSIONS AND CONFLICTS BETWEEN THE VARIOUS ELEMENTS OF THE WORKING DRAWINGS AND/OR SPECIFICATIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH WORK SO INVOLVED. 8. RESOLVE ANY CONFLICTS ON THE DRAWINGS WITH THE ARCHITECT AND ENGINEER BEFORE PROCEEDING WITH CONSTRUCTION. 9. COORDINATE ALL OPENINGS THROUGH FLOORS, WALLS AND ROOF WITH THE APPROPRIATE TRADES. NOTIFY ENGINEER IF ANY OPENINGS ARE TO BE CUT IN STRUCTURAL COMPONENTS. 10. PROVIDE ASPHALTIC MASTIC -COATING ON ALL STEEL AND WOOD EXPOSED TO THE EARTH. 11. PROVIDE A36 ALLTHREAD RODS FOR EPDXY ANCHORS. 12. INJECTION ADHESIVE SHALL BE HIT RE 500 AS FURNISHED BY HILTI INC. OR APPROVED EQUAL. FOUNDATION AND EARTHWORK 1. FOUNDATION DESIGN IS BASED ON SOILS REPORT BY: HP-KUMAR PROJECT NO. 17-7-858, DATED iMMF! ALLOWABLE BEARING PRESSURE: 2,000 PSF iyr_ �CJ� �7hIQ LATERAL EARTH PRESSURE: 40 PCF 2. THE CONTRACTOR SHALL REVIEW THE SOILS REPORT AND FOLLOW ALL RECOMMENDATIONS THEREIN. FOUNDATION DESIGN ASSUMES THAT ALL RECOMMENDATIONS IN THE SOILS REPORT WILL BE IMPLEMENTED. 3. CONTRACTOR TO PROVIDE, AT HIS EXPENSE, FIELD DENSITY TEST ON COMPACTED 7, FILL UNDER FOOTINGS AND INTERIOR SLABS -ON -GRADE. A MINIMUM OF 1 REPRESENTATIVE TESTS SHALL BE TAKEN FOR EACH FOOTING AND SLAB -ON -GRADE. 4. NOTIFY SOILS ENGINEER WHEN EXCAVATION IS COMPACTED SO THAT CONDITIONS MAY BE INSPECTED PRIOR TO PLACEMENT OF ANY FILL OR CONCRETE. 5, ALL INTERIOR NON -BEARING, NON -SHEAR WALLS SHALL HAVE RAMSET/REDHEAD POWDER ACTUATED FASTENERS 1500, 1600 OR 1900 SERIES OR APPROVED EQUAL AT 24" o.c., 1" MINIMUM PENETRATION. 6. FINISHED EXCAVATION FOR FOUNDATION SHALL BE NEAT AND TRUE -TO -LINE WITH ALL LOOSE MATERIAL AND STANDING WATER REMOVED FROM EXCAVATIONS. 7. THE GROUND SURFACE SURROUNDING THE EXTERIOR OF THE BUILDING SHOULD BE SLOPED TO DRAIN AWAY FROM THE FOUNDATION IN ALL DIRECTIONS. IT IS RECOMMENDED THAT A MINIMUM SLOPE OF 12 INCHES IN THE FIRST 10 FEET IN UNPAVED AREAS, AND A MINIMUM SLOPE OF 3 INCHES IN THE FIRST 10 FEET IN PAVED AREAS BE PROVIDED. CONCRETE 1. CONCRETE HAS BEEN DESIGNED AND SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE LATEST EDITIONS OF AMERICAN CONCRETE INSTITUTE BUILDING CODE, ACI 318 AND SPECIFICATIONS FOR STRUCTURAL CONCRETE FOR BUILDINGS. ACI 301. PROVIDE HOT OR COLD WEATHER PROTECTION PER ACI 305 AND 306. 2. SUBMIT MIX DESIGNS TO ARCHITECT FOR REVIEW BY ENGINEER A MINIMUM OF ONE WEEK PRIOR TO FIRST CONCRETE DELIVERY. NO ADMIXTURES CONTAINING CHLORIDE SALTS ARE PERMITTED. CONCRETE SHALL NOT BE IN CONTACT WITH ALUMINUM. 3. CEMENT TO BE MIXED PER ASTM C94. 4. CEMENT: _AOD REG/0 ASTM C150, TYPE II, LOW ALKALI. p �qj A o°°4� . 5. AGGREGATE: U c Q� O PER ASTM C33, MAXIMUM 1" °0 280850' 0 6. MAXIMUM WATER/CEMENT RAT10, BY WEIGHT: °O W/c = 0.50�'°°0000 �o SaNA 7. AIR ENTRAINMENT: 4.0-7.0% 06-07-2019 8. FLY ASH MAXIMUM 20% OF MASS OF CEMENTITIOUS MATERIAL 9. MAXIMUM TEMPERATURE IN MIXER: 90 DEGREES F 10. SLUMP: 4" t 1". NO WATER SHALL BE ADDED ON SITE. 11. MINIMUM STRENGTH: F'. = 3000 PSI AT 28 DAYS AT STEM WALLS AND FOOTINGS F'. = 4000 PSI AT 28 DAYS AT FLAT WORKS 12. CURING SHALL IMMEDIATELY FOLLOW THE FINISH OPERATION. KEEP CONCRETE CONTINUOUSLY MOIST FOR AT LEAST 7 DAYS USING A POLYETHYLENE FILM SECURELY HELD IN PLACE OR AN ALTERNATE METHOD APPROVED BY ARCHITECT. 13. TESTING: EMPLOY AN INDEPENDENT TESTING AGENCY ACCEPTABLE TO OWNER TO DESIGN CONCRETE MIXES AND TO PERFORM MATERIAL EVALUATION TESTS. PROVIDE 7 AND 28 DAYS CYLINDER TESTS. COMPLY WITH ASTM C143, C173, C31 AND C39. 14. GROUT UNDER COLUMN BASE PLATES ETC, WITH HIGH STRENGTH, NON -SHRINK, NON-METALLIC GROUT EQUIVALENT TO MASTERFLOW NO. 713 APPLIED PER MANUFACTURER'S RECOMMENDATIONS REINFORCING STEEL 1. REBARS: DEFORMED STEEL, ASTM SPEC. A615 GRADE 60, ALL REBAR BENDS TO BE MADE COLD. 2. CONCRETE PROTECTION: SLABS AND WALLS NOT EXPOSED TO EARTH OR WEATHER ....... 1" CONCRETE DEPOSITED AGAINST EARTH WITHOUT FORMS ....... 3" 3. CONCRETE EXPOSED TO WEATHER AFTER FORMING: #6 REBAR AND LARGER ....... 2" CLEAR #5 REBAR AND SMALLER ....... 1 1/2" CLEAR 4. BAR LAP: CONCRETE: 40x BAR DIAMETER, 24" MINIMUM. UNLESS NOTED OTHERWISE. MASONRY: 45x BAR DIAMETER, 24" MINIMUM. UNLESS NOTED OTHERWISE. STAGGER SPLICES 5. REINFORCING IN CONCRETE PLACED AGAINST EARTH WITHOUT FORMS IS TO BE SUPPORTED WITH APPROVED NON-METALLIC CHAIRS OR ANOTHER METHOD APPROVED BY THE ENGINEER. 6. PLACE (2) #5 2" FROM ALL SIDES OF OPENING (8 BARS TOTAL) WITH 2'-0- PROJECTION ON EACH END OF ALL WALL OPENINGS. oddo enginee*ProD 713 COOPER AVE SUITE 200 GLENWOOD SPRINGS, CO 81601 970-945-1006 ENGINEER R.A.O. DRAWN BY B.A.H now Jo0 Q mW O 0 O Q W 1-1 r�rk V Z M IROJ.cr Na 0113-63 1AI' CONSTRUCTION 04-30-19 REVISION 06-07-19 STRUCTURAL GENERAL NOTES + DETAILS SCALE 3Ar P-0" �1 SCALE: NTS 1800-63 Rudd V S.ALL.dwg = FRAMING PLAN SCALE: 3/16" = 1'—O" FOU 4" SLAB —ON —GRADE #4 ® 18" o. c. E. N MIDDLE OF SLAB ON GRANULAR MATERIP SEE SOILS REPORI TION PLAN 3/16" = l'—O" TYPICAL HEADER PER 2/S4.0 VHF w 07V ��c'�-� c.aC. GwrxAmoz ------------- I I NOTES: BASED ON GARNER ASSOCIATES DRAWINGS DATED 04-14-2019. FOR HEADEROT SHOWN SEE GENERAL NOTES AND DETAIL 2/S4.0. PROVIDE BUILT-UP WOOD COLUMNS A MINIMUM NUMBER OF STUDS TO EQUAL SUPPORTED BEAM WIDTH (UNLESS NOTED OTHERWISE ON PLANS). 4p0 RGj� Qg E T 00 Q�FWT; , % o v 8 IX oonoc O A 06-07-2019 NOTES: BASED ON GARNER ASSOCIATES DRAWINGS DATED 04-14-2019. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS, AND SITE CONDITIONS BEFORE STARTING WORK AND NOTIFY THE ARCHITECT AND ENGINEER IMMEDIATELY OF ANY DISCREPANCIES. DO NOT SCALE DRAWINGS. IF FOOTINGS ARE NOT BEARING ON UNDISTURBED NATURAL SOIL, BEARING CAPACITY SHALL BE VERIFIED BY SOILS ENGINEER WITH A COMPACTION TEST. LEGEND: STEP FOOTING N STEP WALL HANGING CONDITION —� BEARING CONDITION --� FULL PENETRATION WELD WOOD COLUMN (SOLID PACK —OUT EQUAL TO WIDTH OF BEAM ABOVE, UNO.) 0 STEEL COLUMN odd.o engineering 713 COOPER AVE SUITE 200 GLENWOOD SPRINGS, CO 81601 970-945-1006 ENGINEER R.A.O. DRAWN BY B.A.H I J Q H C/) 0 Z C) Q C) r4 0 U E-4 0 u DATE CONSTRUCTION 04-30-19 REVISION 06-07-19 STRUCTURAL PLANS SCALE 35? = r-V 1800-63 Rudd V S.ALL.dwg LOCATION MAP ill = 500' UILDING RJNTAGL ROAD , X X-_ _-- - - 50 0 .■ _ N\ ®® C.Onanion OT rermli: LEGEND FUTURE CHIP/SEAL PAVEMENT (GRAVEL SURFACE THIS PHASE) PROPOSED DRAINAGE DIRECTION (ROOF PITCH DIRECTION IF INSIDE BLDG.) NOTES ........... FUTURE CONCRETE DRAINAGE PAN 1. ROOF DRAINAGE FOR BUILDING V TO BE DIRECTED TO CATCH BASIN. ROOF DRAINAGE FOR BUILDING Q TO BE DAYLIGHTED TO ROADSIDE DITCH. Q BUILDING DESIGNATION 2. THE CENTRAL DRAINAGE PAN SHALL BE 4' WIDE WITH A 2" DROP FROM EDGE TO CENTER. MINIMUM THICKNESS AT CENTER: 4". MINIMUM 28 DAY _ _ _ _ _ _ _ _ — _ 50 FOOT OFFSET FROM PROPERTY LINE CONCRETE COMPRESSIVE STRENGTH: 4000 PSI. (FUTURE) PROPERTY LINE 3. SEE (ADDED) SHEET 4 FOR ADDITIONAL GRADING AND DRAINAGE INFORMATION. ALSO SEE DRAINAGE REPORT, PRINTED SEPARATELY. X = XX.XX PROPOSED ELEVATION Cut -Off Drainage Swale shall be Approved by Geotechnical Engineer Prior to Concrete Footings Inspection - Prior to Building Dept. inspection of concrete footings, the Structural ZONE BOUNDARY Engineer of Record shall perform site inspection to verify that uphill site grading & drainage meets intended design requirements for drainage away from the foundation. Submit EnRineer's report for Inspector review at Footing Inspection. Scale in Feet _, , RECONSTRUCT EXISTING I Engineer of Record shall penumi —, f -- bmll .:.onriod design requirements for drainage away from the foundation. u .. M� kz- 1�N r= r ti r LOCATION OF EXISTING CUT (UNUSED UTILITY PATH). UTILIZE FOR DIVERSIONS AROUND BLDGS. (SEE DTL.SHT 4) 5 8/10/201 ADD GRADING/REVISE ISDS TPB 4 12/11/19 CHG. EX. TOPO/REVISE GRADING TPB 3 1/26/19 ADD GRADING/DRAINAGE INFO TPB 2 9/10/19 ADD GRADING/DRAINAGE INFO TPB 1 8/6/19 ADD SETBACK LINE-ADJ. BLDGS. TPB REV NO. DATE REVISION MADE BY CHKD BY APPD BY SITE & DRAINAGE PLAN SW AREA SCALE: NOTED DRAWN BY: TPB DATE: 19 JULY 2019 CHKD BY: APPD BY: TA Z TAZ W/ DRAINAGE DITCH ON UPHILL SIDE- RIPRAP STEEP SECTIONS OF DITCH SHEET 1 OF 3 PLAN NO. v TOPO MVW 5.30.1 i Cattle Creek Commercial Center SHEET NO. Wayne Rudd ZANCANELLA AND ASSOCIATES, INC. > ENCINEERINO CONSUL TANTS POST OFFICE BOX 1908 - 1005 COOPER AVENUE PROJECT: 97404.01 GLENWOOD SPRINGS, COLORADO 81602 (970) 945-5700 0— Scale in Feet for Traffic Plan EXISTING BUILDING g -go-googggoo goo g goo � -CiR . 1 57 �J / SPACES BETWEEN BUII.DII '�—SERVE AS TURN AROUND & A S IF NEEDED r__ .r; wow goo goo goo goo ago ong goo goo I HIGHWAY 82 -- -� HIG 8 % --w TRAFFIC FLOW PLAN NUUL oo:P...* q • 9 ;o<� ;a WATER AND SEWER PLAN 2 6 0 x PARKING & TRAFFIC FLOW PLAN 50 100 150 e SCALE: DATE: SHEET e aN Scale in Feet 1 /10/20 ADD GRADING/REVISE ISDS TPB ALE 6 NOTED 11JULY 2019 2 OF 3 for Traffic Plan REV MADE CHKD APPD DRAWN BY: CHKD BY: APPD BY: PLAN NO. NO. DATE REVISION BY BY BY Itpb TAZ TAZ SWTOPOMVW0530201 IJ 000 7 Cattle Creek Commercial Center SHEET Wayne Rudd ZANCAM-ZZA AND ASSOCIATES, INC. ENS/NEER/NO CONSUL TANTS POST OFFICE BOX 1908 — 1005 COOPER AVENUE P CT. 4 GLENWOOD SPRINGS, COLORADO 81602 (970) 945-5700