HomeMy WebLinkAboutPlansA. ARCHITECTURAL SYMBOLS D. CONSTRUCTION AND FINISH SYMBOLS THE SYMBOLS USED TO DIFFERENTIATE CONSTRUCTION WILL BE THE FOLLOWING: EXISTING CONSTRUCTION TO REMAIN, SOLID OR HATCHED EXISTING CONDITION TO BE DEMOLISHED, DASHED OPEN NEW CONSTRUCTION, OPEN B. POWER/ COMMUNICATION SYMBOLS DEMO. NEW EXISTING yT WALL MOUNTED DUPLEX RECEPTACLE 7 WALL MOUNTED QUAD RECEPTACLE WALL MOUNTED TELEPHONE PULL STRING 7N V WALL MOUNTED DUAL TELEPHONE/ DATA PULL STRING C> WALL MOUNTED PULL STRING FOR FURN. SYSTEMS- COMMUNICATIONS 0 WALL MOUNTED J-BOX- ELECTRICAL ® ® FLUSH FLOOR MOUNTED POKE- THRU, DUPLEX RECEPTACLE 0 FLUSH FLOOR MOUNTED POKE- THRU, DUPLEX RECEPTACLE -: ® 0 FLUSH FLOOR MOUNTED POKE- THRU, TELEPHONE PULL STRING ® FLUSH FLOOR MOUNTED POKE- THRU, DUAL TEL/ DATE PULL STRING ® FLUSH FLOOR MOUNTED POKE- THRU, J-BOX *SOLID FILL OR 'E' DENOTES EXISTING TO REMAIN. C. REFLECTED CEILING SYMBOLS- REFER TO RCP FOR ADDITIONAL SYMBOLS DEMO, NEW EXISTING 0 ® 2X4 RECESSED FIXTURE r -n �_J 2X2 RECESSED FIXTURE r, O • RECESSED CAN LIGHT �. qo 4D RECESSED WALL WASHER Q 4 9 TRACK LIGHT PENDANT FIXTURE Al WALL SCONCE T $N $ SWITCH CEILING FAN SYMBOLS DOOR/HARDWARE TYPE T9 PARTITION TYPE FLOOR FINISH TRANSITION WALL FINISH w1 BASE FINISH/ TYPE F, FLOOR FINISH CEILING FINISH ® GLASS OR GLAZING TYPE FPL-1 PLASTIC LAMINATE FINISH E. REFERENCE SYMBOLS LIBRARY 111 1 ROOM NAME/ NUMBER 03/IA5.2 ELEVATION KEY r o; Ia3.2 DETAIL SECTION 14/IA9.2 TYP. ENLARGED DETAIL, SECTION OR PLAN [i] KEY NOTE REVISION 101 EQUIPMENT REFERENCE 7' CEILING HEIGHT N PLAN NORTH 5' DIMENSION LINE Ai ALTERNATE -1RST FLOOR AREA OF WORK 700 R.S.F. SECOND FLOOR AREA OF WORK 15,841 R.S.F. BUILDING LOCATION PROJECT NAME. - PROJECT NUMBER: BUILDING OCCUPANCY TYPE: BUILDING CONSTRUCTION TYPE: NUMBER OF STORIES IN BUILDING WILLIAMS FIELD SERVICES 2014.077.003 TYPE B OCCUPANCY TYPE IIB, NON- SPRINKLERED 2 FLOORS N � M I DSTRLAM �I 12 2YIJ COUNTY ROAD #215 SECOND FLOOR PARACHUTE, COLORADO 81635 BUILDING AREA: APPROX. 30,051 SF 1ST FLOOR- 15,841 SF 2ND FLOOR- 14,911 SF PROJECT SCOPE OF WORK: TENANT INTERIOR RENOVATION PROJECT SCOPE SQUARE FOOTAGE: ENTIRE 2ND FLOOR- 14,911 SF 1ST FLOOR FILE RM- 700 SF PER GARFIELD COUNTY- REGISTERED BUILDING ADDRESS IS: TOTAL: 15,611 SF 1821 COUNTY ROAD #215 CODE INFORMATION: PARCEL #240902200� 4S BUILDING CODE: 2009 IBC (INTERNATIONAL BUILDING CODE) ENERGY CONSERVATION CODE: 2009 IECC (INTERN. ENERGY CONSERV. CODE) AMERICAN SODA, 90 ACRE PARCEL JUST OUTSIDE OF PARACHUTE FIRE CODE: 2009 IFC (INTERNATIONAL FIRE CODE) FUEL GAS CODE: 2009 IFGC (INTERNATIONAL FUEL GAS CODE) MECHANICAL CODE: 2009 IMC (INTERNATIONAL MECHANICAL CODE) PLUMBING CODE: 2009 IPC (INTERNATIONAL PLUMBING CODE) ELCTRICAL CODE: 2014 NEC (NATIONAL ELECTRIC CODE) NFPA NFPA 72 ALL: WITHLOCAL AMMENDMENTS 15 PROJECT INFORMATION N N PLAN TRUE N❑RTH NORTH TENANT WILLIAMS FIELD SERVICES ONE WILLIAMS CENTER TULSA, OK, 74172 918.573,4521 PH. CONTACT- JACQUE HILL jacque.hill@williams.com MEP ENGINEER M-E ENGINEERS 10055 W 43RD AVE WHEAT RIDGE, CO. 80033 303.255,1655 PH. 303.421.0331 FX. PM CONTACT- ED HORNFECK, P.E. ed.hornfeck@nne-engineers.com 720,898.3172 PH, ELEC. CONTACT: BRIAN BOWYER, P.E. jessica.mahn@rne-engineers.com 720.898.3117 PH, GENERAL CONTRACTOR TBD 11 1 PROJECT NAME ARCHITECT RONAN DESIGN GROUP 9055 EAGLE CLIFF ROAD CONIFER, CO. 80433 303.886.8499 PH. CONTACT. SARAH RONAN HORNFECK sarah@ronandesigngroup.com BUILDING OWNER AMERICAN SODA/ SOLVAY CHEMICALS 2717 COUNTY ROAD #215 SUITE 100 PARACHUTE, CO. 81635 970.285.0428 PH. CONTACT: DAVID VALVODA dcvid.volvoda@solvay.com ARCHITECTURAL A0.00 COVER SHEET, PROJECT INFORMATION, SYMBOLS & KEY PLAN A0.01 CODE INFORMATION A0.02 GENERAL NOTES, FINISH SCHEDULE, ALTERNATE PRICING DOOR, FRAME & HARDWARE SCHEDULE A1.02 DEMOLITION PLAN, 2ND FLOOR A1a.02 DEMOLITION REFLECTED CEILING PLAN, 2ND FLOOR A2.02 ARCHITECTURAL PLAN, 2ND FLOOR A3.02 POWER/ COMMUNICATION PLAN, 2ND FLOOR A4.02 REFLECTED CEILING PLAN, 2ND FLOOR A5.02 FINISH PLAN, 2ND FLOOR A6.01 ENLARGED PLAN- RECEPTION DESK & RESTROOMS ACCESSORY SCHEDULE A7.01 ELEVATIONS A7.02 ELEVATIONS A8.01 DETAILS, WALL. SECTIONS A8.02 DETAILS A8.03 DETAILS CONDITIONS OF PERMIT BLCO-10-14-3430 Williams/American Soda/Solvay Office Remodel 1821 (2717) CR 215 Parachute, CO 1) ALL WORK MUST COMPLY WITH THE 2009 IBC, IMC, IPC, IFGC, IFC, IECC AND MANUFACTURERS INSTALLATION SPECIFICATIONS. 2) PRIOR TO CONSTRUCTION, CONTACT LOCAL FIRE DISTRICT FOR PERTINENT IFC REQUIREMENTS. FIRE DISTRICT FINAL APPROVAL REPORT IS REQUIRED FOR FINAL/COMPLETION INSPECTION. 3) ACCESSIBILTY REQUIREMENTS PER 2009 IBC, CHAPTER 11, AND ICC/ANSI A117.1-2003. SEE REDLINE NOTES AND PLAN ATTACHMENTS ON PAGES A6.01 AND A7.02. 4) ROUGH IN PLUMBING INSPECTION REQUIRED PRIOR TO FRAMING INSPECTION. 5) ROUGH IN MECHANICAL INSPECTION REQUIRED PRIOR TO FRAMING INSPECTION, 6) VERIFY EXIT DIRECTIONAL SIGNS/EMERGENCY LIGHTING LOCATIONS PRIOR TO ELECTRICAL ROUGH IN INSPECTION. 7) ELECTRICAL ROUGH IN APPROVAL IS REQUIRED PRIOR TO FRAME INSPECTION. 8) ELECTRICAL FINAL APPROVAL IS REQUIRED FOR FINAL/COMPLETION INSPECTION. 9) LOCKS, LATCHES AND LANDINGS PER 2009 IBC, SECTION 1008. L:10) AND VENTILATION PER 2009 IBC, CHAPTER 12. ! I MECHANICAL & PLUMBING M0.00 MECHANICAL LEGEND M0.01 MECHANICAL GENERAL NOTES M1.10 MECHANICAL DEMO PLAN- LEVEL 2 M2.10 MECHANICAL PLAN - LEVEL 2 M8.01 MECHANICAL DETAILS PO.00 PLUMBING NOTES AND LEGEND PO.01 PLUMBING SCHEDULE P1.10 PLUMBING DEMO PLAN - LEVEL 2 P2.10 PLUMBING PLAN- LEVEL 2 P8.01 PLUMBING DETAILS AND ISOMETRICS ELECTRICAL EO.00 ELECTRICAL LEGEND E0.01 ELECTRICAL ONE -LINE DIAGRAM E0.02 ELECTRICAL PANEL SCHEDULES E0.03 ELECTRICAL PANEL SCHEDULES E0.04A ELECTRICAL SPECIFICATIONS E0.04B ELECTRICAL SPECIFICATIONS E1.10 ELECTRICAL DEMO PLAN- LEVEL 2 E2.10 ELECTRICAL PLAN- LEVEL 1 E2.11 ELECTRICAL PLAN- LEVEL 2 E3.10 LIGHTING PLAN- LEVEL 2 E8.01 ELECTRICAL DETAILS AMOVO IIIIIIIIIJISM17 w?#(YM . A"C"wM 6 L m u�i c3 ca a.. C�_J m Co E o A � 13 E c wX CV SSUES AND REVISIONS A NO. DATE DESCRIPTION 09.11.14 ISSUE FOR PRELIMINARY PRICING 09.22-14 ISSUE FOR 95% MEP BACKGROUNDS 10.01.14 ISSUE FOR CARPET ORDER 10,06,14 ISSUE FOR PRICING, PERMIT & CONSTRUCTION s 9055 EAGLE CLIFF ROAD CONIFER, COLORADO 80433 PH: 303.886.8499 E: sarah®ronondesigngroup.com SEAL/ SIGNATURE WILLIAMS • MIDSTREAM Solvay Chemical Building 2717 County Road 215 Parachute, Colorado 51635 2nd Floor & 1 St floor Partial SHEET TITLE: COVER & INFORMATION SHEET SHEET NUM�R: O O /� U KEY PLAN- 1ST 2ND FLOORS 13 PROJECT TEAM 09 INDEX TO DRAWINGS 01 NO WORK IN ROOM/ AREA NOTED EXISTING MILLWORK TO REMAIN EXISTING CONSTRUCTION TO REMAIN, SOLID OR HATCHED EXISTING CONDITION TO BE DEMOLISHED, DASHED OPEN NEW CONSTRUCTION, OPEN HATCH LEGEND 1S- PLAN 0 TYPE '1' DOOR, FRAME & HARDWARE TO BE REMOVED & SALVAGED FOR RE —LOCATION. TYPE Y DOOR, FRAME & HARDWARE TO BE REMOVED & SALVAGED FOR RE —LOCATION. 16 1 RE -USED DOOR TYPES 0 REMOVE CARPET IN ELEVATOR CAB, 1221 DEMOLISH EXISTING MILLWORK 0 DEMOLISH EXISTING WIRE MOLD AND ASSOCIATED POWER DATA. ELECTRICAL PERMnINGaiNsPEcT10%ARE / BY THE COiARAi30 STATE ELECTRICAL BOAR ® DEMOLISH EXISTING WALL HUNG TOILET PARTITION. DEMOLISH EXISTING POWER POLE. KEEP POWER AT CEILING FOR FUTURE USE. RE: MEP DRAWINGS. ® REMOVE EXISTING RADIATOR. SALVAGE FOR RE —USE AT SIMILAR LOCATION. �] IN BATHROOMS— REMOVE ALL EXISTING FINISHES, FIXTURES A MILLWORK. SALVAGE PLUMBING AS POSSIBLE. ® DEMOLISH EXISTING WATER COOLER, SALVAGE PLUMBING AS POSSIBLE. ® ROOM NOTED HAS EXISTING FLOORING TO REMAIN. CLEAN. ® DEMOLISH EXISTING PLUMBING. SALVAGE PIPING AS POSSIBLE FOR RE —USE AT NEW SINK. 11 DEMOLISH EXISTING BLACK FILM FROM WINDOWS, CLEAN. © EXISTING BLINDS TO REMAIN. © (2) LARGE HOLES IN FLOOR— CUT DOWN PIPES TO BE FLUSH WITH SLAB & FILL. ® DEMOLISH WALL MOUNTED A/C UNIT. DEMOLISH (2) SLEEVES AT WALL. REMOVE EXISTING KNOB HARDWARE & REPLACE WITH LEVER. © SIDELITE TO BE RELOCATED. 12 I KEYED NOTES A. ALL EXISTING RADIATORS TO REMAIN. REMOVE &/OR PATCH AS REQUIRED AT RELOCATED, DEMOLISHED OR NEW PARTITIONS. REPAIR ALL LOOSE OR MISSING COVERS AND VENTS. B. SALVAGE ALL RE -USABLE ITEMS (THERMOSTATS, STROBES ETC...) FOR TENANT'S RE -USE. LEVEL FLOOR AT DEMOLITION AS REQUIRED TO MATCH 'AS NEW' CONDITIONS AND TO BE READY TO RECEIVE NEW FINISHES. SALVAGE & RE -USE ALL EXISTING TEMPERED SIDELITES & DOOR FRAMES. C: - DEMOLISH ALL EXISTING POWER, DATA & PHONE CONNECTIONS IN DEMOLISHED PARTITIONS. REMOVE TO SOURCE AS REQUIRED BY CODE. D. AT ALL DEMOLITION, PATCH AND REPAIR ALL ADJACENT SURFACES TO MATCH 'AS NEW' CONDITIONS. CLEAN, REPAIR AND PREPARE SURFACE TO REMAIN FOR NEW CONSTRUCTION & FINISHES. REMOVE ALL BLANK WALL BOXES- PATCH AND FINISH WALL TO BE IN 'AS NEW' CONDITION. E. GC RESPONSIBLE TO INVESTIGATE DURING BID ANY WORK REQUIRED ON FLOOR BELOW IN ORDER TO ACCOMODATE ALL CONSTRUCTION ON THIS FLOOR. (E.G.- AT FLOOR CORES, PLUMBING ETC...) F. ALL PERIMETER WINDOW COVERINGS ARE TO REMAIN, UNO. BAG, & PROTECT. G. THIS IS AN OCCURED BUILDING. COORDINATE ALL NOISY OR DISRUPTIVE WORK WITH BUILIDNG OWNER. ENSURE ALL CODES ARE MAINTAINED DURING CONSTRUCTION. H. EXISTING FLOOR PENETRATIONS TO BE FILLED AND SEALED PER CODE. (GC TO VERIFY QUANTITY.) DEMOLISH ALL EXISTING FLOORING AND BASE, UNO, 08 I, GENERAL NOTES HE ISSUES AND REVISIONS A NO. DATE DESCRIPTION 09.11.14 ISSUE FOR PRELIMINARY PRICING 09.22.14 ISSUE FOR 95% MEP BACKGROUNDS 10.01.14 ISSUE FOR CARPET ORDER 10.06.14 ISSUE FOR PRICING, PERMIT & CONSTRUCTION a � � 9055 EAGLE CLIFF ROAD CONIFER, COLORADO 80433 PH: 303.886.8499 E: sarah®ronandesigngroup.com SEAL/ SIGNATURE CO %E 3189 5 act 201 WILLIAMS MIDSTREAM Solvay Chemical Building 2717 County Road 215 Parachute, Colorado 81635 2nd Floor & 1st floor Partial SHEET TITLE: DEMOLITION (\ PLAN �2ND FLOOR SHEET NUMBER: Al O 2 1 /8 0" 101 PROJECT NUMBER: 2014-077-003 NO WORK IN ROOM/ AREA NOTED HATCH LEGEND 1ST M DEMOLISH GRID & TILES IN AREA NOTED. RE. REFLECTED CEILING PLAN FOR ADDITIONAL INFORMATION 0 DEMOLISH EXISTING NON -USED SWITCH. PATCH WALL. 0 NOT USED. ® REMOVE EXISTING MOTORIZED PROJECTION SCREEN AND SALVAGE FOR RE -USE AT NEW LOCATION NOTED ON RCP. WALL MOUNTED BELOW CEILING. REMOVE EXISTING CEILING MOUNTED POWER & DATA FROM FORMER CONFERENCE ROOM. ® NOTE USED. [21 LEAVE HEADER IN PLACE WHERE WALL WAS REMOVED IN ORDER TO KEEP EXISTING CEILING GRID OF VARYING HEIGHTS IN PLACE. ® DEMOLISH EXISTING 'BLUE LIGHT' MOUNTED ON CEILING. DO NOT SALVAGE. 16 1 KEYED NOTES L. GENERAL CONTRACTOR TO COORDINATE ALL TRADES TO INSURE ALL JUNCTION BOXES, CONTROL WIRING VALVES OR ANY OTHER ITEM REQUIRED FOR ACCESS OR BY CODE IS LOCATED ABOVE ACCESSIBLE CEILING AND NOT ABOVE DRYWALL CEILING CONSTRUCTION, MOVE ALL ITEMS AS REQUIRED TO AVOID ACCESS PANELS IN DRYWALL CEILINGS. M. ALL DEVICES AT DRYWALL CEILING AREAS TO ALIGN WITH ARCHITECTURAL DETAILS. REFER TO PLAN AND PROVIDE LAYOUT FOR REVIEW PRIOR TO INSTALLATION. N. ALL REUSED DfFFUSERS, GRILLS ETC... TO BE CLEANED, PAINTED AND/ OR REPAIRED AS REQUIRED TO RETURN TO 'AS NEW' CONDITION. 0. RE: A0.02 FOR ALTERNATE PRICING NOTES REGARDING CEILING. p_ CC IS RESPONSIBLE FOR VERIFYING ALL RE -USED, EXISTING & NEW LIGHTING QUANTITIES. 12 1 GENERAL NOTES A. REFER TO COVER SHEET FOR ADDITIONAL NOTES & SYMBOLS. REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. ANY CON LICTS BETWEEN MEP AND ARCHITECTURAL DRAWINGS TO BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION PRIOR TO COMMENCEMENT OF WORK. B. REFER TO POWER & COMMUNICATION PLAN FOR ADDITIONAL INFORMATION. C. REFER TO MEP DRAWINGS FOR ALL LIGHT SCHEDULES, INFORMATION & DIMMING LOCATIONS. ALL DIMMERS TO BE USED WTIH MANUFACTURER'S RECOMMENDED DIMMING BALLAST. SWITCHES AND DIMMERS SHALL BE GANGED TOGETHER UNDER ONE SWITCH PLATE WHERE MULTIPLE DEVICES OCCUR AT ONE LOCATION, D. REFER TO A8.02 FOR STANDARD MOUNTING HEIGHT DETAILS, ALL RECEPTACLES, FACE PLATES & SWITCHES TO BE WHITE, UNO. E. CEILING HEIGHTS VARY AND ARE NOTED ON PLANS. ALL CEILINGS ARE 'Cl' UNO. F. GENERAL CONTRACTOR RESPONSIBLE TO CONDUCT FIELD INVESTIGATION AT CEILING CAVITY TO ENSURE THERE ARE NO CONFLICTS AT ALL CEILINGS DUE TO EXISTING STRUCTURE, LOW DUCT WORK, CONDUITES OR SPRINKLER LINES. NOTIFY ARCHITECT OF CONFLICTS FOR CLARIFICATION PRIOR TO COMMENCMENT OF WORK OR ORDERING FIXTURES. G. ALL GYPSUM BOARD CEILINGS TO BE PAINTED 'P2', UNO. H. CENTER LIGHTS IN CEILING T{LES AS SHOWN. I. REFER TO MEP DRAWINGS FOR LOCATIONS OF LIFE SAFETY LIGHTING AND EXIT SIGNAGE. ALL NEW DEVICES (EXIT SIGNS ETC...) TO MATCH BUILDING STANDARD, UNO. J. CLEAN ALL EXISTING OR RELOCATED LIGHTS. ENSURE ALL LIGHTS ARE IN WORKING ORDER AND ALL ARE SET CORRECTLY IN GRID. K. REPAIR ALL BROKEN, DAMAGED OR SAGGING GRID. REPLACE 10% OF EXISTING TILES TO REMAIN (IN ADDITION TO THOSE NEEDED FOR DEMOLITION OR CONSTRUCTION OR OTHERWISE NOTED) WITH NEW 'Cl' TILE. 08 IGENERAL NOTES 1, ISSUES AND REVISIONS A NO, DATE DESCRIPTION 09.11.14 ISSUE FOR PRELIMINARY PRICING 09.22.14 ISSUE FOR 95% MEP BACKGROUNDS 10,01.14 ISSUE FOR CARPET ORDER 10.06.14 ISSUE FOR PRICING, PERMIT & CONSTRUCTION D � A 4 DDESEG_� sR21j 9055 EAGLE CLIFF ROAD CONIFER, COLORADO 80433 PH: 303,886.8499 E: sarah0ronandesigngroup.mm SEAL/ SIGNATURE o� col® CO ANNE. ON q �SFD AR& r WILLIAMS MIDSTREAM Solvay Chemical Building 2717 County Road 215 Parachute, Colorado 81635 2nd Floor & 1st floor Partial SHEET TITLE: DEMOLITION REEL. CEILING PLAN 2ND FLOOR SHEET NUMBER: Al a,, O 2 PLAN 1/8„_1,_0" 01 PROJECT NUMBER: 2014-077-003 Ell MODIFY HANDRAILS AT STAIRS (TOP & BOTTOM) TO BE CODE COMPLIANT (MINOR EXTENSIONS REQUIRED.) ❑z MODIFY EXISTING WALL TO MATCH A TYPE 'C' PARTITION WITH PLUMBING. M RE: 03/A6.01 FOR ENLARGED PLAN OF RECEPTION DESK. ® FULL HEIGHT ADJUSTABLE SHELVING. RE: 09 & 10/ A8.03 FOR DETAILS. 5 SHELVES HIGH. RE: 01/A6.01 FOR ENLARGED PLAN OF RENOVATED ADA COMPLIANT RLSTROOMS. © NEW HIGH/ LOW ADA COMPLIANT WATER COOLERS. RE: MEP DRAWINGS FOR INFORMATION. RELOCATED SIDE LITE OR NEW TO MATCH EXISTING. ® CORNER GUARDS- BACK PAINTED 'P1' ABOVE BASE TO 8'-0" CEILING. ® NEW BUILDING STANDARD MINI BLINDS AT WINDOW NOTED (ON INTERIOR ROOM SIDE.) INCLUDE PRICE TO HAVE MINI BLINDS 1N (4) ADDITIONAL OFFICES (LOCATIONS TO BE DETERMINED IN FIELD WITH TENANT.) NEW BUILDING STANDARD MINI BLINDS AT PERIMETER WINDOW NOTED. TO MATCH EXISTING. 11 RE: MEP DRAWINGS FOR ALL INFORMATION IN MECHANICAL ROOM. © EXISTING DOOR NOTED TO HAVE NEW ELECTRIFIED HARDWARE (PROVIDED BY CC) TO COORDINATE WITH NEW CARD READER. RE: MEP DRAWINGS FOR FIRST FLOOR LOCATIONS OF CARD READERS- THOSE DOORS WILL NEED TO BE MODIFIED IF THEY ARE NOT ALREADY ELECTRIFIED. G.C. TO VERIFY IN FIELD. MARKER BOARD W/ METAL WALL. RE: ELEVATIONS. METAL SHEET TO BE APPLIED TO WALL BEHIND MARKER BOARD. ENSURE A LEVEL 5 FINISH TO SURFACE OF METAL. ® ALTERNATE PRICE #API TO REPLACE LAMINATE RESTROOM COUNTER TOPS WITH NEW 'PL1' COUNTER TOPS. A. REFER TO COVER SHEET FOR ADDITIONAL NOTES & SYMBOLS. B. ALL PARTITION TYPES ARE TYPE 'A', UNO. REFER TO SHEET A8.01 FOR PARTITION TYPES. AT WALLS TO DECK- ENSURE THAT NO GAPS ARE LEFT AROUND PENETRATIONS. ENSURE NEW WALLS ARE PROPER THICKNESS TO RE -USE DOOR FRAMES. C. ALL DOORS ARE TYPE '1', UNO. REFER TO AO.01 FOR DOOR, FRAME & HARDWARE SCHEDULE. RE: A8.02 FOR DOOR & SIDELITE DETAILS. ALL NEW PRIVATE OFFICE SIDELITES TO BE PER PLAN, RE -USE EXISTING AS CALLED OUT IN DEMOLITION PLAN, OR PROVIDE NEW TO MATCH EXISTING. D. WHERE EXISTING CONSTRUCTION IS REMOVED- CLEAN, REPAIR AND PREPARE SURFACE TO REMAIN FOR NEW CONSTRUCTION & FINISHES. E. GENERAL CONTRACTOR TO ENSURE THAT ALL EXISTING SURFACES ARE PREPARED AND READY TO RECEIVE SCHEDULED FINISH, F. ALL WOOD BLOCKING AND COMPONENTS WITHIN PARTITION AND CEILING PLENUM SHALL BE FIRE TREATED. G. WINDOW COVERINGS EXISTING. GC TO BAG & PROTECT BLINDS FOR THE DURATION OF CONSTRUCTION. CLEAN & UN -BAG AT PROJECT END. H. SCRIBE ALL MILLWORK TO ADJACENT SURFACES WHERE REQUIRED. CONTRACTOR TO PROVIDE BLOCKING IN ALL PARTITIONS THAT HAVE MILLWORK, UNO. I. CENTER ALL PARTITIONS ON MULLIONS OR PERIMIETER COLUMNS, UNO. OR ALIGN EDGES AS SHOWN, J. REFER TO A0.02 FOR ALTERNATE PRICING NOTES, K. THIS IS A PARTIALLY OCCUPIED BUILDING, ALL NOISY OR DISRUPTIVE WORK NEEDS TO BE COORDINATED WITH SOLVAY CHEMICALS. ENSURE ALL CODES ARE MAINTAINED DURING CONSTRUCTION. CONTRACTOR TO COMPLY WITH ALL BUILDING RULES & REGULATIONS. GENERAL CONTRACTOR TO PROTECT ALL EXISTING ITEMS TO REMAIN FOR THE DURATION OF CONSTRUCTION. L. ALIGN ALL WALLS AS SHOWN, UNO. 1 �16 � �12 � KEYED NOTES �08 GENERA'S NOTES 104 q 1ST SSUES AND REVISIONS A NO. DATE DESCRIPTION 09.11.14 ISSUE FOR PRELIMINARY PRICING 09.22.14 ISSUE FOR 95% MEP BACKGROUNDS 10.01.14 ISSUE FOR CARPET ORDER 10.06.14 ISSUE FOR PRICING, PERMIT & CONSTRUCTION 9055 EAGLE CLIFF ROAD CONIFER, COLORADO 80433 PH: 303.886.8499 E: sarah@ronondesigngroup.com SEAL/ SIGNATURE O� C04�� CO ANNE RHEA 203188 WILLIAMS MIDSTREAM Solvay Chemical Building 2717 County Road 215 Parachute, Colorado 81635 2nd Floor & 1st floor Partial SHEET TIT : ARCHITECTURAL PLAN 2ND FLOOR KEY DESCRIPTION NEW/ RELOCATED I PROVIDE & INSTALLED BY CjqD COPIER RELOCATED BY TENANT 102 PLOTTER RELOCATED BY TENANT 103 PRINTER RELOCATED BY TENANT 104 SHREDDER RELOCATED BY TENANT 10� VIDEO CONFERENCING PACKAGE RELOCATED BY TENANT'S A V VENDOR 106 MOTORIZED PROJEC. SCREEN RELOCATED GENERAL CONTRACTOR M VENDING MACHINE NEW OR RELOCATED BY TENANT 10s MICROWAVE NEW GENERAL CONTRACTOR 109 COFFEE MACHINE RELOCATED BY TENANT GC 110 ADA SINK & FAUCET NEW GENERAL CONTRACTOR 111 DISHWASHER NEW GENERAL CONTRACTOR CIM REFRIGERATOR/ FREEZER RELOCATED BY TENANT NO WORK IN ROOM/ AREA NOTED EQUIPMENT SCHEDULE/ HATCH LEGEND 1ST NOTES PAIR OF FLAT SCREENS/ VIDEO CONFERENCING SYSTEM- WILL ALSO HAVE A CAMERA & CPU. RELOCATED DRAPER MOTORIZED PROJECTION SCREEN— PREMIER SERIES 68"H X 50"W TBD GENERAL ELECTRIC, #JEB1860DMBB, BLACK, 1.8 CU FT TENANT TO MOVE TO SITE, GENERAL CONTRACTOR TO HOOK UP WATER LINE WATER LINE REQUIRED. ELKAY SINK #GECR— 2521 (ENSURE HOLES ARE COMPATIBILE WITH FAUCET & ACCESSORIES SPECIFIED.) DELTA FAUCET— ALLORA SINGLE HANDLE PULL —DOWN, #989---SS—DST, BRILLIANT BRUSHED ST. STEEL FINISH (ORDER ESCUTCHEON FOR OTHER FLOORS IF NEEDED TO COVER HOLES.) ENSURE THERE IS ALSO FILTERED WATER AT SINK. INCLUDE DISPOSAL. RE: MEP DRAWINGS GENERAL ELECTRIC, #GLD2800TBB, BLACK NO WATER LINE REQUIRED. E0 SUPPLY PULL STRING & BLANK COVER PLATE FOR CARD READER. C.C. TO ROUGH IN BOX WITH PULL STRING. SECUIRTY VENDOR TO FURNISH & INSTALL ALL ELECTRIC HARDWARE. PREP OF EXISTING DOORS TO BE BY SECURITY VENDOR. RE: MEP DRAWINGS FOR ADDITIONAL INFORMATION. ❑2 J—BOX PAIR— ONE FOR POWER/ ONE FOR DATA— FOR SYSTEMS FURNITURE. G.C. TO CONNECT WHIP (PROVIDED BY OTHERS) TO WALL. (INCLUDE PRICING FOR 2 ADDITIONAL J—BOX PAIRS AT A LOCATION TBD.) 17311 NEW LOCATION FOR RELOCATED, MOTORIZED PROJECTION SCREEN, WALL MOUNTED JUST BELOW CEILING. ® RE: MEP DRAWINGS FOR ALL INFORMATION IN MECHANICAL ROOMS. 0 MODIFY EXISTING CARD READER AS REQUIRED FOR NEW SYSTEM. ® SUPPLY FLUSH FLOOR CORE FOR POWER/ DATA UNDER CONFERENCE TABLE. STUB CONDUIT & PULL STRING TO ABOVE ADJACENT WALL. 0 PROVIDE (1) 1 1/4" CONDUIT FROM (1) 2 GANG J—BOX IN WALL, STUB UP ABOVE CEILING & RUN TO FLOOR CORE. PROVIDE (1) 1 Y" CONDUIT FROM NEW VIDEO CONFERENCING SYSTEM (FLAT SCREENS) TO NEW CPU MOUNTED IN ADJACENT CREDENZA. EXACT LOCATION TBD IN FIELD. ® CENTER FLOOR CORE IN ROOM. ❑9 FLOOR CORE LOCATION TBD. AT FIRST FLOOR— NOT SHOWN ON PLANS, PROVIDE CARD READER BOXES & PULL STRINGS AT THE FOLLOWING LOCATIONS: (3) STAIRWAYS— EXTERIOR DOORS, (1) RECEPTION AREA, (1) ELEVATOR. RE —USE CARD READER AT FIRST FLOOR SERVER ROOM, RE: MEP DRAWINGS FOR INFORMATION. 12 IGENERAL NOTES A. REFER TO COVER SHEET FOR ADDITIONAL NOTES & SYMBOLS. REFER TO MEP DRAWINGS FOR ADDITIONAL INFORMATION. ANY CONFLICTS BETWEEN MEP AND ARCHITECTURAL DRAWINGS TO BE BROUGHT TO THE ARCHITECT'S ATTENTION FOR CLARIFICATION PRIOR TO COMMENCEMENT OF WORK. B. REFER TO A8.02 FOR STANDARD MOUNTING HEIGHTS. C. REFER TO REFLECTED CEILING PLAN FOR ADDITIONAL POWER REQUIREMENTS AT CEILING. D. REFER TO 12/A3.02 FOR EQUIPMENT SCHEDULE. E. ALL DEVICES SHOWN ADJACENT TO EACH OTHER SHALL BE CANCED TIGHT. DO NOT LOCATE ADJACENT DEVICES ONTO NEAREST STUD. USE BRIDGE STUD OR MULTI— DEVICES. GANG FRAMING PLATES AS REQUIRED. F. AT VOICE/ DATA PORTS— GC TO SUPPLY BOX & PULL STRING ONLY. G. ALL FURNITURE IS SHOWN FOR REFERENCE ONLY— BY OTHERS. H. ALL DEVICES LOCATED IN WET AREAS SHALL BE GFI OR EQUAL TYPE DEVICE. REFER TO MEP DRAWINGS. I. ALL RECEPTACLES, FACE PLATES & SWITCHES TO BE WHITE, UNO. J. FINAL PLACEMENT OF ALL HORNS, STROBES & THERMOSTATS TO BE COORDINATED WITH ARCHITECT. K. ALL ELECTRICAL, DATA OR A/V BELOW SLAB OR THROUGH PUBLIC SPACE TO BE IN CONDUIT. L. FLOOR MUST BE X—RAYED PRIOR TO ANY FLOOR PENETRATIONS. M. IN ALL OFFICES— NEW DUPLEX & VOICE/ DATA PORTS TO BE AT LEAST 30" FROM BACK WALL. N. RE: MEP DRAWINGS FOR ALL INFORMATION ON PERIMETER RADIATORS. 08 GENERAL NOTES ISSUES AND REVISIONS A NO. DATE DESCRIPTION 09.11.14 ISSUE FOR PRELIMINARY PRICING 09.22.14 ISSUE FOR 95% MEP BACKGROUNDS 10.01.14 ISSUE FOR CARPET ORDER 10.06.14 ISSUE FOR PRICING, PERMIT & CONSTRUCTION D � � J E � `�i G IN CG IR, CoJ U F1 9055 EAGLE CLIFF ROAD CONIFER, COLORADO 80433 PH: 303.886.8499 E: saroh@ronandesigngroup.com SEAL/ SIGNATURE �OF C 04 co P:NNE D AR WILLIAMS MIDSTREAM Solvay Chemical Building 2717 County Road 215 Parachute, Colorado 81635 2nd Floor & 1st floor Partial SHEET TITLE: OWER & COMMUN, 77:2ND LAN FLOOR SHEET NUMBER: /\ 3,,0 PLAN 1/8_1,_0" 01 PROJECT NUMBER-. 2014-077-003 z O O N N 00 z N N IIY IIV IV I O o ; A CA I Q z zrnp� o0000 000 FT 0 I (n m CrL a o n FT-1 CDCD7�0 'O C7 X O C � -< D D z c to r � I rn CD A o I Z ITI M � � T1 -� m r I TI � V7 r- D o C)C) o cV) � 'r'-' = Q y (� FF1 r,-f O D m L/) rr -1 C Q � a -{ D -u m a CAl1 n Z7 r rn O m Goo C m rr D W = -M m = Q m m A D> �1 rri n c z z r- o z m m X = � � � rn C-) D m m C:) =1 r c z rr� 7 c m Q o c o \ I W = /, LO a a a n a a a a n a a n 1 (D j co t!n o) w I I I oo a� cln co i O Am 1 4 I o N O f N CT)\�-»��� \ / F-rl a A a a n a a y o y y a a i/ co z o co 00 -I i c� Ln n a n CD I I z c) cn co Co cn ;;a ;;a C) co co -0 ";]a C) co co -0 cn oa co c- cn m m n cn m m c-) :;a r : C= ;;0 N � CA r7N I Oc m- C> c I oD o c I oD ND I a� ivDD- I o� '.,n I CDC mn rn�; mF ---- - -- 00 O m NCcj � m= OI MM � �CI] M CJi 2,o;0 cr CJi �QCOD Cn mOMD � �� �� rn — to �m cn LO— rn -zCD--zoo�ao =zOo— m� T7 m � �rn� cu Q TI[T,�CZ) �_ rr0') ao m.Z07 �r Frl o - a p? cn z z cn � n Z cn � G7 c �< a r� m N cn m cn cn m cn cn rn cn cn Q a o y ,,, m ; ,-- m -iS70 �S29 mS� D— Da n �cc �z z � a � cmn � cmn � n :E Q = z a c' cn En �< x x f o cz') 0 C7 S f� I�T1 Z C7o N CJ] (n z in a Q _ cn m n m -3 S xQz] x r— r= r C-)GZ-7 o S Z Ol cn -4 cn cn _ � N' _ mrm m o cn cn D D m in O co S >< C) o rQ --� W CDa, n m z z Qz = o' m Ily lly o x m I � � 0 o A r o ITl r-7-1 z � z Q 7'-0" VIF 6-10 3/8" VIF 0 01/A7.02 c� _ 3,-6„ 1 0 _ „ '- " 4'--10 7 8"+ - Fq-FT rn ;v c� C C y � W o Xk— Fr� N ` / ` o �\ o � r o 04/ 1 � C)` i� \1 r� J e OH 1 / N 04 A7.02 FT-11 CDAh 1 0 03/A7.02 o , N ITl \ oN / z o y 1 OH �v 06 A7, 02 y o C 01 /A7.02 Oo 06/A7.02 - - - - - - -- - 02/A7.02 - 0 1'-6„ r N N IIV IIV IY IJ 0 0 0 0 I � 0 r r� cam., r ra c� I N O IT1 --I- N Oo 7 1 L � cn cn m m m n � z � z C F- C m c R 7U Fr F-) z o M m o C) g,�M Q C-k CD O U) > V 1 �z y 0 �° c 0 %< o #_0 yr 9C " mcl) r INNIL o on X > cso�� o M a M ic MUl� =. > Ln 2) U CIO m D w y� �Jcn fl � ?' D O 00 O � Q � a � CD <Z _ 0 12 go � W 0 .a /: n - oo m (L ZD (= m O N j 41 z �ccc m m m m �00 Z M m O z 0 z m o �o n Z O Z nD Z Z L � 0 OFFICE 244 VESTIBULE 243 OFFICE 241 OFFICE 240 STOR. 253 T T 2 / N T ! I H L I r I , r r' I L OPEN OFFICE — _ — P1- I I L � 111 I ��il 11 i II T f ! rI I I I I rr LLJ OFFICE OFFICE OFFICE OFHCE OFFICE [ COPY/ COFFEE 245 246 247 248 249 251 L !I 2 I STOR. I ! ku All� 25a � I I ! IA II ! T T CO I�jSI � 235 II ® MEN T 0/1 STAIR #2 254 CONE, RM OFFICE OFFICE 256 257 258 ELEV. 255 14 15 17 18 19 I IH I IHI I OPEN TO BELOW _-J Ilj VESTOULE �JF 201 ::1 DUCTWORK DISTRIBUTION jVIF 200 UNABLE TO BE T SURVEYED. MEN 268 WOMEN 267 EXHAUST RISER & DUCTWORK TO REMAIN VIF,TYP. — OFFICE 265 OFFICE 264 , r H41 FN / STAIR #3 202 r i n F--7I u Li lbl n N n If � ! CORRI. 266 I I I � I i OFFICE I OFFICE OFFICE OFFICE 263 259 260 261 I OFFICE I I T =r � , 262 I I I � -- -! — — — - — -- — —� I � z L 6 6 6 I I I T I U _rv'j I I - — S 0 — ELEC. STOR. OFFICE �► 228 — — ------ 220 219 — 218 r-- 7- -- -- _rA----------- - T —L"E IsN e c '��� T 221 _ I ELFq - r i I'; ❑ ' I WOMEN OPEN ICE 232 — ! I � I �T % CONF. RM. OPEN O C I 214 I , T F I ( MIA L j� H O E AI 1 1LIZ El_ — J o� - - OFFICE OFFICE MAP RM MECHANICAL RV #1 MECHAICAL R #2 IT WORK M t° I OFFICE OFFICE f OFFICE WORK R �- _ STOR. 239 238 237 234 233 F226 225 224 223 216 215 s 2 3 4 5 6 7 8 9 105 12 13 14 15 16 17 1S MECHANICAL PLAN -LEVEL 2 LE: 1 /8" = 1'-0" A CCN�__ RV. 203 RECEPTION VIF 204 OFFICE 205 R ---(: TE) OFRCF 206 OFFICE 207 O OFFICE 208 OFFICE 209 G H OFFICE 210 OFFICE 211 OFFICE LL2js BREAK RM 213 GENERAL NOTES, 1. DUCTWORK DRAWINGS REFLECT EXISTING DUCT LOCATiONS ONLY. CONTRACTOR TO FIELD VERIFY DUCT LOCATIONS AND DUCT SIZES NOT INDICATED AND PROVIDE A SKETCH OF EXISTING CONDITIONS PRIOR TO DEMOLITION. 2. RAISE EXISTING DUCTWORK AND PIPING AS REQUIRED TO ACCOMMODATE NEW CEILINGS. REFER TO ARCHITECTURAL DRAWINGS FOR CEILING HEIGHTS. 3. FIELD VERIFY EXISTING VAV BOX CONTROL PANEL LOCATIONS AND MAINTAIN ACCESS TO CONTROL PANEL. 4. REMOVE ALL EQUIPMENT, DUCTWORK, AND PIPING NOT USED BY THE DESIGN INTENT. CAP ALL SYSTEMS AS REQUIRED FOR A FULLY OPERATIONAL SYSTEM. CAP UNUSED BRANCH TAKEOFFS AIRTIGHT. 5. INSTALL TEMPORARY MERV 8 FILTERS OVER RETURN AIR OPENINGS DURING CONSTRUCTION PERIOD. REMOVE TEMPORARY FILTERS UPON OCCUPANCY. 6. FIELD VERIFY EXISTING SUPPLY DUCTWORK INSULATION PRIOR TO DEMOLITION AND REPAIR OR REPLACE EXISTING INSULATION TO ACHIEVE A FULLY INSULATED DUCT SYSTEM. WHERE EXISTING SUPPLY DUCT IS CURRENTLY NOT INSULATED, PROVIDE NEW INSULATION PER MECHANICAL SPECIFICATIONS. 7. REFER TO MECHANICAL DETAIL DRAWINGS FOR ADDITIONAL INSTALLATION REQUIREMENTS. 8. FIELD VERIFY CONDITION OF EXISTING SPIN COLLARS AND MANUAL VOLUME DAMPERS TO BE REUSED PRIOR TO DEMOLITION, WHERE EXISTING SPIN COLLARS OR MANUAL VOLUME DAMPERS ARE DAMAGED OR INOPERABLE, REMOVE AND REPLACE SPIN COLLAR AND REPORT TO ARCHITECT AND ENGINEER. KEY NOTES, (SOME KEY NOTES MAY NOT APPLY TO THIS SHEET) ❑1 REMOVE THERMOSTAT SHOWN WITH CROSS HATCHING. RETAIN THERMOSTAT FOR RELOCATION. ❑ RE —INSTALL RELOCATED THERMOSTAT WHERE INDICATED. EXTEND PNEUMATIC TUBING AS REQUIRED. ®3 REMOVE SUPPLY DIFFUSER AND FLEX DUCT BACK TO FLEX CONNECTION TO GALVANIZED SUPPLY DUCT. RETAIN SUPPLY DIFFUSER FOR RELOCATION. ❑ REMOVE RETURN GRILLE AND RETAIN FOR RELOCATION. ❑ RE —INSTALL EXISTING SUPPLY DIFFUSER IN LOCATION INDICATED. PROVIDE NEW FLEXIBLE DUCT CONNECTION. MATCH FLEX DUCT SIZE TO EXISTING SUPPLY DIFFUSER NECK SIZE. [E]RE—INSTALL EXISTING RETURN GRILLE IN LOCATION INDICATED. EI PROVIDE NEW PERIMETER BASEBOARD COVER WHERE EXISTING WALL IS REMOVED. MATCH EXISTING BASEBOARD HOUSING SHAPE AND PAINT TO MATCH EXISTING BASEBOARD HOUSING. �8 EXISTING PIPING SERVING HYDRONIC BASEBOARD TO REMAIN IN KNEE WALL. REFER TO ARCHITECTURAL DRAWINGS. ❑ REMOVE EXISTING THERMOSTAT SERVING VAV BOX INDICATED. RETAIN THERMOSTAT FOR RELOCATION. FIELD VERIFY LOCATION OF THERMOSTAT, 10 REFER TO AIR BALANCE VERIFICATION REQUIREMENTS ON DRAWING M1.10 FUR DUCTWORK IN THIS AREA. PROVIDE FIELD SKETCH OF EXISTING CONDITIONS. FIELD SKETCH REQUIRED BEFORE NEW SCOPE CAN BE INDICATED. 11 REMOVE EXISTING SSAC AND CORRESPONDING CONDENSING UNIT NOT SHOWN. FIELD VERIFY LOCATION OF CONDENSING UNIT AND REPORT TO ARCHITECT AND ENGINEER. COMPLETELY REMOVE ALL REFRIGERANT LINE SETS, COMPONENTS, AND ACCESSORIES ASSOCIATED WITH THE SSAC UNIT. [AREFURBISH OR REPLACE EXISTING CONTROLS AIR COMPRESSOR TO ELIMINATE EXCESS NOISE AND VIBRATION. PROVIDE REPORT INDICATING EXISTING COMPRESSOR CONDITION AND OPERATION TO ARCHITECT AND ENGINEER PRIOR TO DEMOLITION. 13 REMOVE EXISTING HYDRONIC BASEBOARD AND RETAIN FOR RELOCATION. REMOVE AND/OR MODIFY BRANCH PIPING AS REQUIRED FOR RE —CONNECTION OF BASEBOARD IN NEW LOCATION. f4 RE —INSTALL EXISTING HYDRONIC BASEBOARD IN LOCATION INDICATED. PROVIDE NEW BRANCH PIPING AND CONNECTION. MATCH BRANCH PIPING SIZE TO EXISTING. PROVIDE NEW BASEBOARD END COVER WHERE BASEBOARD END IS EXPOSED. MATCH EXISTING BASEBOARD HOUSING SHAPE AND PAINT TO MATCH EXISTING BASEBOARD HOUSING. ISSUES AND REVISIONS 0 NO. DATE DESCRIPTION 09.11.14 ISSUE FOR PRELIMINARY PRICING 09.22.14 ISSUE FOR 95% MEP BACKGROUNDS 10.06.14 ISSUE FOR PRICING, PERMIT & CONSTRUCTION meM-E Engineers, Inc. 10055 west 43rd avenue wheat ridge, co 90033 t 303.421.ff""303.421.0331 engineers www.me-engineers.com D � p 9055 EAGLE CLIFF ROAD CONIFER, COLORADO 80433 PH: 303,886.8499 E: sarah@ronondesigngroup.com SEAL/ SIGNATURE apG Rol;; 44, �k i �•��r�►yy l3 ,. GPSY ft ' j 6 WILLIAMS MIDSTREAM Solvay Chemical Building 2717 County Road 215 Parachute, Colorado 81635 2nd Floor & 1st floor Partial SHEET TITLE: MECHANICAL PLAN - LEVEL 2 SHEET NUMBER: M2. 10 PROJECT NUMBER: 2014-077-003 PLUMBING FIXTURE SCHEDULE CODE FIXTURE DESCRIPTION LOCATION MIN CW CONN. MIN HW CONN. MIN SAN CONN. MIN VENT CONN. MANUFACTURER & MODEL NO. FAUCET/FLUSH VALVE REMARKS WC--1 WATER CLOSET (ADA) WALL MTD — FV — 1.6 GPF TOILET RM. 1" — 4" 2" AMERICAN STANDARD 2257.103 (AFWALL) SLOAN ROYAL 110 FLUSH VALVE ADA,EB,FV,S,VC,WH,WO (1.6 GPF) UR-1 URINAL (ADA) WALL HUNG +17" AFF TO RIM TOILET RM. 3/4" — 2" 1-1/2" AMERICAN STANDARD 6561.017 (TRIMBROOK) SLOAN ROYAL 186 FLUSH VALVE ADA,WH,FV,VC,WC,(1.0 GPF) L-1 LAVATORY (ADA) SELF RIMMING COUNTERTOP TOILET RM. 1/2" 1/2" 1-1/2" 1-1/2" AMERICAN STANDARD 0491.019 (RONDALYN) AMERICAN STANDARD 7385.003 (RELIANT 3) ADA,VC, VR, (SEE NOTE # 2) S-1 SINK SINGLE COMPT GENERAL 1/2" 1/2" 2" 1-1/2" ELKAY GECR--2521 DELTA 989—AR—DST AND ELKAY LK1110 WATER DISPENSER ADA,SS,CT, COORDINATE PUNCHED HOLES FOR FAUCET AND WATER DISPENSER INSTALLATION GD-1 GARBAGE DISPOSER 1-1/2" 1-1/2" IN--SINK—ERATOR BADGER V 1/2 HP, 120V, 1PH WF-1 WATER FILTER SIZES AS NOTED PENTEK BFS-201 FOR FLOW RATES UP TO 10 GPM-- EWC-1 ELECTRIC WATER COOLER DUAL WALL MTD — HI—LO 1/2" 1/2" 1-1/4" 1-1/4" HAWS H1117.8 (BARRIER —FREE CHILLED DUAL) 120V, 1PH, 5 FLA, PROVIDE MODEL HCR8 CHILLER AND MTGFR.17 MOUNTING BRACKET. GENERAL NOTES 1. PLUMBING DESIGN AND SIZES ARE BASED ON THE 2003 INTERNATIONAL PLUMBING CODE. 2. ALL EXPOSED PIPING SERVING PLUMBING FIXTURES THAT MAY BE USED FOR ADA PURPOSES SHALL TRAPS AND SUPPLIES INSULATED PER ADA REQUIREMENTS. 3. ALL FIXTURE ARE WHITE UNLESS OTHERWISE NOTED. 4. SHOWERHEADS TO BE MOUNTED AT 6'-6" IN WOMENS SHOWER AREAS AND 7'-6" IN MIENS SHOWER AREAS. 5. CONTRACTOR TO VERIFY SLAB THICKNESS FOR PERFORATED MEMBRANE EXTENSION. 6-- PROVIDE POLISHED BRONZE TOP WITH HEEL PROOF GRATE IN PARKING GARAGES WHERE WHERE FOOT TRAFFIC IS ANTICIPATED DEFINITIONS: ADA — AMERICANS WITH DISABILITIES ACT APPROVED HH — HAND HELD SHOWER WC — WALL FIXTURE CARRIER AS - ANTISCALD WH — WALL HUNG MV — MIXING VALVE WO — WALL OUTLET BO — BOTTOM OUTLET MF — METERING FAUCET CT — COUNTER TOP PB — PRESSURE BALANCING PTB — PRESSURE — TEMPERATURE BALANCED EB — ELONGATED BOWL PES — PORCELAIN ENAMELED STEEL EBF — ELECTRONIC, BATTERY OPERATED FAUCET E'Br--V — ELECTRONIC, BATTERY OPERATED FLUSH VALVE S — SOLID WRITE ELONGATED OPEN FRONT SEAT, LESS COVER WITH CHECK HINGE SC — SOLID WHITE ELONGATED OPEN FRONT SEAT WITH COVER FC — FLASHING CLAMP SS — STAINLESS STEEL FM — FLOOR MOUNTED FP — FREEZE PROOF VB — VACUUM BREAKER FR — FLOW RESTRICTOR VC — VITREOUS CHINA FT.— TANK VR — VANDAL RESISTANT FV — FLUSH VALVE WATER HEATER SCHEDULE (ELECTRIC) CODE (EWH) MANUFACTURER/ MODEL NO. LOCATION STORAGE (GALLONS) RECOVERY (100 TR) REMARKS ELECTRICAL KW VOLT PH FLA DISCONNECT FEEDER 2-1 A.Q. SMITH DSE-20 BREAK AREA 20 12 A, B 3 277 1 10.8 $TO (2#12,1 #1 2G)3/4"C GENERAL NOTES 1. SEE MECHANICAL REMARK NOTES A, ROUTE ALL T & P B_ ALL HEATERS TO DETAILS. RELIEF VALVES TO APPROVED RECEPTORS. BE PROVIDED WITH IMMERSION THERMOSTATS WITH CONTACTORS ISSUES AND REVISIONS A N0. DATE DESCRIPTION 09.11.14 ISSUE FOR PRELIMINARY PRICING 09.22.14 ISSUE FOR 95% MEP BACKGROUNDS 10.06.14 ISSUE FOR PRICING, PERMIT & CONSTRUCTION M-E Engineers, Inc. 10055 west 43rd avenue wheat ridge, co 80033 t 3(13.421.60551i• 303.421.0331 engineers www.me-engineers.com � 04 AAA DIE_V�04 F�GGjp 9055 EAGLE CLIFF ROAD CONIFER, COLORADO 80433 PH: 303.886.8499 E: sorahOronandesign group. com SEAL/ SIGNATURE F 4[is�1{q.1 C [ig V WILLIAMS MIDSTREAM Solvay Chemical Building 2717 County Road 215 Parachute, Colorado 81635 2nd Floor & 1st floor Partial SHEET T�TLE:PLUMBING SCHEDULES SHEET NUMBER: PO. 1 PROJECT NUMBER: 2014-077-003 7 T9 11 14 15 1 4' VESTIBULE 1 243 1 OFFICE 241 OFFICE 240 OFFICF OFFICE OFFICE 244 245 246 OPEN OFFICE 236 I OPEN OFFICE 252 OFFICE OFFICE OFFICE COPY/ COFFEE 247 248 249 251 STOR, 250 STOR. i 253 I t H 37 2-1 WF-1 BELOW COUNTER-T02 CORK REFER TO ISOMETRIC FOR 235 NEW WORK REQUIREMENTS. 38 AJ WOMEN 232 " S 1 GD 1 DISH ER 1-1/2' �.�3/4» CW -�l�R. 39 7.30 MEN 231 111111101 Hi STAIR#2 I 2547 CONE. RM OFFICE OFFICE 256 257 258 ELEV. 255 1 TV. JAN. STOR. 28 �9 2C� OFFICF 239 OFFICE 238 MAP RM 237 MECHANICAL M #1 234 MECHAICAL R #2 233 IT WORK M 226 1 3 4 5 0 7 8 9 100 FT i IH I IHI I! -------OPEN TO BELOW VESTIBULE 201 OFFICE OFFICE 2 9 1 C 260 ELEC. STOR. OPEN OFFICE 222 H STAIR #4 2� q18 19 MEN 268 WC-1 UR-1\� REFER TO L-1 ISOMETRIC FOR NEW WORK REQUIREMENTS. 1 _- WC-1 L�-1_ WOMEN 267 REFER TO ISOMETRIC FOR NEW WORK REQUIREMENTS. OFFICE 265 LIL OFFICF 264 OFFICE OFFICE 263 261 OFFICE ��-- 262 OFFICE 218 OFFICE 217 I OFFICE OFFICE OFFICE WORK R OTS R. 225 224 223 F 216 215 6 STAIR #3 202 n �_ I J u n n u LA B CONE. RM 203 C � _ RECEPTION 204 CONNECT NEW SA TO EXISTING SAN E ! G TOILETM CONTRACTOR TO ELD OFFICE VERIFY SIZE, -AKD CONFIGURATRI 1. 20b CONTINUATION TO EXISTING CW, HW, AND VENT. CONTRACTOR TO FIELD VERIFY SIZE, E CONFIGURATION. CONTINUATION TO EXISTING CW, EWC-1 VENT, AND SAN. CONTRACTOR TO OFFICE lFLD VERIFY 206 LOCATION, AND FIGURATION. :-:NTINUATION OFFICE TO 207 XISTING CW, ENT, AND SAN. ONTRACTOR TO IELD VERIFY SIZE CORR. OCATION, AND 266 ONFIGURATiON. C FHC CONE, RM, 214 COFFEE MAKER CONTINUATION TO EXISTING CW, HW, AND VENT. CONTRACTOR TO ]FIELD VERIFY SIZE, LOCATION, AND Ll CONFIGURATION. 12 13 14 15 16 17 18 OFFICE 208 OFFICE 209 G (H� OFFICE 210 OFFICE 211 F�-, 11 --QUM .WF--1 BELOW OFFICE COUNTERTOP 212 N I _ DISHWASHER BREAK RM 213 S-1 W/ GD-1 I REFER TO ISOMETRIC FOR Q NEW WORK REQUIREMENTS. 19 PLUMBING PLAN -LEVEL 2 ALE: 1 /8" = 1'— GENERAL NOTES, 1. REQUIRED PIPE SIZES ARE SHOWN NEXT TO KEY NOTE SYMBOL. 2. PROVIDE BALL VALVE SHUTOFF AND 12"X12" ACCESS PANEL AT EACH SHOCK ABSORBER (SA). PANEL LOCATION TO BE VERIFIED AND COORDINATED WITH ARCHITECT. 3. ALL PIPING SHALL BE STUBBED UP +24" FOR EXTENSION. 4. ALL INVERT ELEVATIONS (IE) SHALL BE FIELD VERIFIED BEFORE ANY PIPING IS INSTALLED. 5. ALL CIRCUIT SETTERS SHALL BE SET AT 1.0 GPM UNLESS NOTED OTHERWISE. 6. SLOPE ALL EQUIPMENT DRAIN PIPING AT 1 /8" PER 12" HORIZONTAL RUN TOWARD DRAIN. KEY NOTES, (SOME KEY NOTES MAY NOT APPLY TO THIS SHEET) FI SANITARY PIPING UP 21 SANITARY PIPING ON F31SANITARY PIPING UP & ON ® GW PIPING UP ® GW PIPING DN EDGW PIPING UP & ON I `I SANITARY VENT UP 1E SAN TAR VENT G� M SANITARY VENT UP & ON 10 CW PIPING UP 11 CW PIPING DN 12 CW PIPING UP & ON 13 HW PIPING UP 14 HW PIPING DN 15 HW PIPING UP & ON 16 HWC PIPING UP 17 HWC PIPING ON 18 HWC PIPING UP & ON 19 CW&HWUP 20CW &HW ON 21 CW&HWUP&ON 22 GAS (5 PSI) PIPING UP 23 GAS (5 PSI) PIPING ON 24 GAS (5 PSI) PIPING UP & DN 28 GAS (6" WC) PIPING UP 2g GAS (6" WC) PIPING DN 27 GAS (6" WC) PIPING UP & DN 28 STORM PIPING UP 29 STORM PIPING DN 3Q STORM PIPING UP & DN 3i OVERFLOW PIPING UP 32 OVERFLOW PIPING ON 33 OVERFLOW PIPING UP & DN 34 CW HEADER 35 HW HEADER 36 CW & HW HEADER 37 MOUNT WATER HEATER ABOVE CEILING ON SUSPENDED STEEL BASE. REFER TO MECHANICAL DETAILS AND SPECIFICATIONS. 38 ROUTE SANITARY LINE IN LEVEL 1 CEILING PLENUM TO TOILET ROOMS ON LEVEL 1. CONNECT TO EXISTING 4" SAN IN TOILET ROOMS. 39 ROUTE CW AND VENT IN LEVEL 2 CEILING PLENUM TO TOILET ROOMS ON LEVEL 2. CONNECT TO EXISTING CW AND VENT MAINS IN TOILET ROOMS. ISSUES AND REVISIONS A NO. DATE DESCRIPTION 09.11.14 ISSUE FOR PRELIM[NARY PRICING 09.22,14 ISSUE FOR 95% MEP BACKGROUNDS 10.06.14 ISSUE FOR PRICING, PERMIT & CONSTRUCTION eM-E Engineers, Inc. 10055 west 43rd avenue wheat ridge, co 80033 t. 3..42,.6,,-, /f 303.421,0331 engineers www.me-engincers.com � OIN AAA RN mEglviq eRaup 9055 EAGLE CLIFF ROAD CONIFER, COLORADO 80433 PH: 303-886.8499 E: sarah@ronandesigngroup.com SEAL/ SIGNATURE po Rh3lS �Q • 0 ww+w.ar+a fti AILL Solvay Chemical Building 2717 County Road 215 Parachute, Colorado 81635 2nd Floor & 1st floor Partial SHEET TITLE:PLUMBING PLAN -LEVEL 2 SHEET NUM R: P2.1 O PROJECT NUMBER: — —ooa WILLIAMS PARACHUTE LOAD ANALYSIS LIGHTING EXISTING T12 FIXTURES NEW T8 FIXTURES NEW LTG FIXTURES 136 FIXTURES X 80 W 136 FIXTURES X 56 W 10880 VA 7616 VA 744 NET GAINED VA 2520 VA POWER LOAD REMOVED NEW ELECTRICAL LOAD 99 RECEPTACLES X 180 W 17820 VA 18742 VA NET GAINED VA —922 VA NET POWER REDUCTI❑N NET AMPS GAIN AT 208V 3P 1598 VA 4 AMPS DP—U XDP—S —A XDP—T XDP— LPPB 150A 100A [DP 1OOA 150A 100A 100A MCB MCB MLO MCB MLO MLO YT 45KVA a r- NT FMR 3 OKVA 0 Ln T TFMR 8 30KVA i 0 Ln I T I TFMR 4 30KVA T TFM R 6 30KVA L----------------------------------------- I T I AREA OF WORK 183—EE-9C 183—EE-9D r r I100A 100A MLO MLO 1 {3)#1 1 (3}#1 I {1)#8G (1 )#8G 1 1 /2" C. 1 1 /2" C.1 r r fT30KVA TFMR 7 I TFMR 5 TFMR 3 1 30KVA ' 30KVA ' 0 (3)#6 (3)#6 (1)#1 OG (1)#1 OG 1" C. 1" C. AREA OF WORK LOAD ' ENTE ' 100A I r MLO r I r r (1)#8G '—G� PNL A XDP—K ,OA I 225A 100A LO MLO MLO 1 (3)#1 I (1)#8G 200/3/NF 1 1 /2" C T ' T 75KVA ` T TFMR 21 I TFMR 1 45KVA r —Cl' ' — 30KVA LL_ _� — (3)#1 /0 (1)#6G 1 1 /2" C. NOTE. ALL EQUIPMENT SHOWN IS EXISTING TO REMAIN � I � I z I � � L o I 0 0 0 o 04 I -----......-------_._.--------------------..._..-----N- — ---� TO UTILITY i-�LvISIQNS NO. DATE DESCRIPTION 09.11.14 ISSUE FOR PRELIMINARY PRICING 09.22.14 ISSUE FOR 95% MEP BACKGROUNDS 10.06.14 ISSUE FOR PRICING, PERMIT & CONSTRUCTION meM-E Engineers, Inc. 10055 west 43rd avenue wheat ridge, co 80033 t 303.421.66551L YBA21.0331 engineers www.me-engineers.com � O �IN I 9055 EAGLE CLIFF ROAD CONIFER, COLORADO 80433 PH: 303.886.8499 E: sarah Cron andesign group. corn SEAL/ SIGNATURE ino R G % 1. .� • WILLIAMS MIDSTREAM Solvay Chemical Building 2717 County Road 215 Parachute, Colorado 81635 2nd Floor & 1st floor Partial SHEET TITLE: ELECTRICAL ONE LINE DIAGRAM PROJECT NUM EO.0 I 2014-077-003 Williams Parachute M-E En Ineers Inc. PANEL: 183-EE- 7C 208Y/120 3PHASE,4WIRE+GND BUS: MAINS: 225 Amps M.L.❑. COPPER SECTION: 1 OF 1 LOCATION: NOTES: EXISTING 1. EXISTING LOAD SHALL REMAIN. 2. PROVIDE NEW BREAKER IN EXISTING SPACE. OPTIONS: DATE: 10/02/14 FED FROM : MOUNTING : RECESSED ISSUE: N ID DESCRIPTI❑N V-A P BKR CKT PH _ CKT BKR P V-A DESCRIPTI❑N ID N 1 L RMS 2032, 33, 42 1472 1 20 1 A 2 20 1 1670 CORRIDOR 2010, 34, 35 L 1 1 L RMS 2031, 25, 24 1104 1 20 3 B 4 20 1 1012 RMS 2029, 35, 36 L 1 1 R OUTLETS - EXEC OFFICE 720 1 20 5 C 6 20 1 1678 RMS 2038, 40, 41 L 1 1 L LIGHTS EXEC OFFICE 300 1 20 1 7 A e 20 1 1260 RMS 2024, 25, 31, 33 R 1 1 L RMS 2026, 28 1656 1 20 9 B 10 20 1 720 RMS 2032, 33, 42 R 1 1 L RMS 2020, 23, 27 1656 1 20 11 C 12 20 1 1656 OUTLETS - CENTRAL SECRETARY R 1 1 R LIGHTS - EXEC OFFICE 1080 1 20 13 A 14 20 1 1400 RMS 2036, 37, 38, 44, 65 R 1 1 R RMS 2023, 26, 29 720 1 20 15 B 16 20 1 900 RMS 2028, 35, 36 R 1 1 R RM 2020, 22, 23, 27 1440 1 20 17 C is 20 1 1554 WATER COOLER CORRIDOR 2039 R 1 1 L LIGHTS - CENTRAL SECRETARY 300 1 20 19 A 20 20 1 720 BLUE PRINT RM R 1 1 L LIGHTS - CENTRAL SECRETARY 300 1 20 21 B 22 20 1 300 VACUUM LIGHT L 1 71 R OUTLET IN PHONE ROOM 360 1 20 23 C 24 20 1 1000 COFCE POT RM 2032 R 1 1 R EXISITNG LOAD 1 20 25 A 26 20 1 800 REFRIGERATOR RM 2032 R 1 C SPACE 27 B 28 20 1 750 EXISTING LOAD R 1 C SPACE 29 C 30 20 1 540 CONF RM PROJECTOR R 2 Williams Parachute - Panel Schedules.xls C❑NNECTED (DOWNSTREAM LOADS INCLUDED) PHASE A - B - C TOTALS LOAD SUMMARY WITH DOWNSTREAM LOADS INCLUDED CATEGORY CONNECTED FACTOR CALVD V-A AMPS 0 208Y/120 VOLTS VA 9002 - 7462 - 10604 C 27,068 LIGHTING 11,448 125% 14,310 40 AMPS 75 - 62 - 88 75 RECEPT 15,620 100% 10,000 28 DOWNSTREAM LOADS RECEPT 50% 2,810 8 MOTOR 100% LRGST MTR 25% MISC 100% KITCHEN 100% CONDUCTOR COLORS (EC TO LABEL IN PANEL) ELEC HEAT 100% PH A B C N G BLACK RED PLUS WHITE GREEN TOTAL 127,068 27,120 1 75 Wlllial s Parachute M-E Engineers Inc. PANEL: 183-'EE- )D 208Y/120 3PHASE,4WIRE+GND BUS: MAINS: 225 Amps M.L.❑. COPPER SEC11ON: LOCATION: I OF 1 DATE: 10/02/14 NOTES: EXISTING 1. EXISTING LOAD SHALL REMAIN 2. PROVIDE NEW BREAKER IN EXISTING SPACE OPTIONS: FED FROM : MOUNTING : RECESSED ISSUE: N ID DESCRIPTI❑N V-A P BKR CKT PH CKT BKR P V-A DESCRIPTI❑N ID N 1 L RM 2002, 2004 1080 1 20 1 1 A 2 20 1 734 RM 2003, STAIR, CORRIDOR 2014 L 1 1 L Rms 2009, 2011, 2005 1472 1 20 3 B 4 20 1 1636 RMS 2006, 07, 08 L 1 1 L RMS 2012, 16, 17, 19 1440 1 20 5 C 6 20 1 1103 CORRIDOR 2014 L 1 1 L RMS 2010, 13, 15, 18, 22 1656 1 20 7 A 8 20 1 1620 RMS 2006, 07, 08, 10, 13, 34 R 1 1 R DOUBLE DUPLEX RM 218 180 1 20 9 B 10 20 1 1554 WATER COOLER CORRIDOR 2014 R 1 1 R DOUBLE DUPLEX RM 215 180 1 20 11 C 12 20 1 1000 OUTLETS R 1 1 R RMS 2002, 03, 04 1080 1 20 13 A 14 20 1 540 OUTLETS - BREAKROOM R 1 1 R RMS 2004, 05, 09, 11, 12 1620 1 20 15 B 16 20 1 360 OUTLETS -- BREAKROOM R 1 1 R RMS 2012, 16. 17, 18, 19 1620 1 20 17 C is 20 1 1080 OUTLETS - CENTRAL SECRETARY R 1 1 R OUTLETS - BREAKROOM 750 1 20 19 A 20 20 1 720 OUTLETS - BREAKROOM R 1 1 R REFRIGERATOR - BREAKROOM 800 1 20 1 21 B 22 20 1 1080 HEATER OUTLET RM 211 R 1 1 R WALL FIN HEATER RM 2002 1000 1 20 1 23 C 24 20 1 340 EF-3 ROOF R 1 2 R COPIER 1200 1 20 25 A 26 20 1 1080 HEATER OUTLETS RM 215 R 1 2 R _ PROJECTOR 500 1 20 27 B 1 28 20 1 800 VENDING MACHINE R 2 2 R BREAKRM RCPT 720 1 20 29 C 1 30 20 1 BOG VENDING MACHINE R 2 Williams Parachute - Panel Schedules.xls CONNECTED (DOWNSTREAM L❑ADS INCLUDED) PHASE A - B - C TOTALS LOAD SUMMARY CATEGORY WITH DOWNSTREAM LOADS INCLUDED CONNECTED FACTOR CALC'D V-A AMPS 0 20BY/120 VOLTS VA 10460 - 10002 - 9283C 29.745 LIGHTING 9,121 125% 11.401 32 AMPS 87 - 83 - 77 83 RECEPT 20,624 100% 10,000 28 DOWNSTREAM LOADS RECEPT 50% 100% 5,312 15 MOTOR LRGST MTR 25% MISC 100% KITCHEN 100% CONDUCTOR COLORS (EC TO LABEL IN PANEL) ELEC HEAT 100% PH A B C N G BLACK RED BLUE WHITE GREEN -- - T❑TAL 129,745 1 26,713 74 I 5 Q u i 0 0 Q 0 a O a E a Wllllams Parachute WE Engineers Inc, PANEL: A 208Y/120 3PHASE,4WIRE+GND 22K AIC BUS: MAINS: 250 Amps M,L.❑ COPPER SECTION: 1 OF 1 LOCATION: NOTES: 1. EXISTING LOAD SHALL REMAIN 2. PROVIDE NEW BREAKER IN EXISTING SPACE 3. CONTRACTOR SHALL TRACE AND VERIFY CIRCUIT HAS BEEN ABANDONED 4. REMOVE EXISTING BREAKER AND REPLACE WITH NEW BREAKER AS SCHEDULED OP-nONS: DATE: 10/02/14 FED FROM : MOUNTING : SURFACE ISSUE: N ID DESCRIPTI❑N V-A P BKR CKT PH CKT BKR P V-A DESCRIPTI❑N ID N 1 M WIREMOLD PUMPER ROOM 1560 1 20 1 A 2 20 1 1560 WIREMOLD PUMPER ROOM M 1 1 M WIREMOLD PUMPER ROOM 1560 1 20 3 B 4 20 1 1560 WIREMOLD PUMPER ROOM M 1 1 P --SPARE-- 1 20 5 C 6 20 1 1560 WIREMOLD PUMPER ROOM M 1 4 E EWH2-1 3000 2 25 7 A B 1 20 1 1560 WIREMOLD PUMPER ROOM M 1 4 E - - - - - < 9 B 10 100 3 5856 LOAD CENTER S 1 2 R REFRIGERATOR 800 1 20 11 C 12 > 5120 ----- S 1 2 R MICROWAVE 1200 1 20 13 A 14 > 6140 - - - - - S 1 2 R MICROWAVE 1200 1 20 15 B 16 20 1 1500 COPY MACHINE PUMPER RM R 1 2 R DISHWASHER Boo 1 20 17 C 18 20 1 180 BREAKRM RCPT R 2 2 R DISPOSAL 696 1 20 19 A 20 20 1 180 BREAKRM RCPT R 2 2 R BREAKRM RCPT 180 1 20 21 B 22 20 1 180 BREAKRM RCPT R 2 2 R COPIER 1500 1 20 23 C 24 20 1 1500 PLOTTER R 2 2 P --SPARE-- 1 20 25 A 26 SPACE C 2 2 R WORKSTATIONS 720 1 20 27 B 28 1 SPACE R 2 2 R WORKSTATIONS 720 1 20 29 1 C 30 20 1 720 WORKSTATIONS R 2 2 R WORKSTATIONS 720 1 20 31 A 32 20 1 720 WORKSTATIONS R 2 2 R WORKSTATIONS 720 1 20 33 B 34 20 1 720 WORKSTATIONS R 2 2 R WORKSTATIONS 720 1 20 35 C 36 20 1 720 WORKSTATIONS R 2 2 R WORKSTATIONS 720 1 20 37 A 38 20 1 720 WORKSTATIONS R 2 2 R WORKSTATIONS 720 1 20 39 B 40 20 1 720 WORKSTATIONS R 2 2 R WORKSTATIONS 720 1 20 41 C 42 20 1 720 WORKSTATIONS jR 2 Williams Parachute - Panel Schedules.xls CONNECTED <D❑WNSTREAM LIDADS INCLUDED) PHASE A - B - C TOTALS LOAD SUMMARY ATEGORY WITH DOWNSTREAM LOADS INCLUDED CONNECTED FACTOR CALC'D V-A AMPS 0 208Y/120 VOLTS VA 18492 - 14900 - 168000 50,192 LIGHTING 125% AMPS 154 - 124 - 140 139 RECEPT 37,832 100% 10,000 28 DOWNSTREAM LOADS LOAD CENTER RECEPT 50% 13,916 39 MOTOR 9,360 100% 9,360 26 >"RGST MTR 11,560 25% 390 1 MISC 100% KITCHEN 100% CONDUCTOR COLORS (EC TO LABEL IN PANEL) ELEC HEAT _ 3,000 100% 3,000 8 PH A B C N G BLACK RED BLUE WHITE GREEN TOTAL 50,192 36,666 102 Willlams Parachute M-E Engineers Inc. PANEL: L11AD CENTER 20BY/120 3PHASE,4WIRE+GND BUS: MAINS: 125 Amps M.L.❑. COPPER SECTION: 1 OF 1 LOCATION: NOTES: EXISTING 1. EXISTING LOAD SHALL REMAIN 2. PROVIDE NEW BREAKER IN EXISTING SPACE OPTIONS: DATE: 09/30/14 FED FROM : A MOUNTING : RECESSED ISSUE: N ID DESCRIPTI❑N V-A P BKR CKT PH CKT BKR P V-A DESCRIPTI❑N ID N 1 R EXISTING LOAD 900 1 20 1 A 2 20 1 900 EXISTING LOAD R 1 1 R EXISTING LOAD 900 1 20 3 B 4 20 1 900 EXISTING LOAD R 1 1 R EXISTING LOAD 900 1 20 5 C 6 20 1 900 EXISTING LOAD R 1 1 R EXISTING LOAD 900 1 20 7 A 8 20 1 900 EXISTING LOAD R 1 1 R EXISTING LOAD 900 1 20 9 B 10 20 1 1 900 EXISTING LOAD R R 1 1 1 R EXISTING LOAD 900 1 20 11 C 12 20 1 900 _ EXISTING LOAD 2 R 2ND LEVEL DISPOSAL 696 1 20 13 A 14 20 1 360 2ND LVL VESTIBULE RCPT R 2 2 R 2ND LVL BREAKRM RCPT 180 1 20 15 B 16 20 1 540 2ND LVL CONF RM RPCT R 2 2 R 2ND LVL MICROWAVE 1200 1 20 17 C 18 20 1 540 RECEPTION RCPT R 2 2 R 2ND LVL MICROWAVE 1200 1 20 19 A 20 SPACE C 2 R 2ND LVL REFRIGERATOR 800 1 20 21 B 22 SPACE C 2 R 2ND LVL REFRIGERATOR 800 1 20 23 C 24 SPACE C Williams Parachute - Panel Schedules.xls CONNECTED (DOWNSTREAM LOADS INCLUDED) PHASE A - B - C TOTALS LOAD SUMMARY WITH DOWNSTREAM LOADS INCLUDED ATEGORY CONNECTED FACTOR CALC'D V-A AMPS 0 208Y/120 VOLTS VA 5856 - 5120 - 6140 C 17,116 LIGHTING 125% AMPS 49 - 43 - 51 4$ RECEPT 17,116 100,�6 10,000 2$ DOWNSTREAM LOADS RECEPT 50% 3,558 10 MOTOR 100% LRGST MTR 25X MISC 100% KITCHEN 100% CONDUCTOR COLORS (EC To LABEL IN PANEL) ELEC HEAT 100% PH A BLACK B RED C BLUE N WHITE G GREEN I I TOTAL 17,116 13,558 38 �_ J ISSUES AND REVISIONS 0 NO. DATE DESCRIPTION 09,11.14 ISSUE FOR PRELIMINARY PRICING 09.22.14 ISSUE FOR 95% MEP BACKGROUNDS 10.06.14 ISSUE FOR PRICING, PERMIT & CONSTRUCTION meM-E Engineers, Inc. 10055 west 43rd avenue wheat ridge, co 80033 t30342,66,,,,,03.42,,331 engineers www.me-engineers,com 00 0 NN ORDUP 9055 EAGLE CLIFF ROAD CONIFER, COLORADO 80433 PH: 303.886.8499 E: saroh®ronandesigngroup.com SEAL/ SIGNATURE ��' •.• A. �'•. �p C>p 81 be Fssi • 0 WILLIAMS M IDSTREANf Solvay Chemical Building 2717 County Road 215 Parachute, Colorado 81635 2nd Floor & 1 st floor Partial SHEET TITLE: ELECTRICAL PANEL SCHEDULES SHEET NUMB � EEO.02 PROJECT NUMB z 7-003 r� , FLUORESCENT Type Lamp Description Finish Voltage Mounting Manufacturer Catalog Number Alternate 1 Alternate B Control Location Comments F1 (2) F032/835/XPS/ RECESSED LENSED 2X4 TROFFER, 16 WHITE 120-277V RECESSED DAY—BRITE 2—LP3—G—S---2-32-28— COOPER METALUX APPROVED ELECTRONIC ECO, 36,OOOHR, CELL PARABOLIC LOUVRE, PROVIDE AL—UNV MANUFACTURER PROGRAMMED START 3500K, 85CRI MOUNTING HARDWARE FOR GYP OR ACT >10% THD CEILINGS AS REQUIRED - --- F1E (2) F032/835/XPS/ SAME AS TYPE TV BUT PROVIDE ECO, 36,000HR, EMERGENCY BALLAST AND ROUTE 3500K, 85CRI UNSWITCHED HOT LEG TO FIXTURE. F1E/NL (2) F032/835/XPS/ SAME AS TYPE 'F1E' BUT FIXTURE ECO, 36,OOOHR, SHALL BE WIRE FOR 24 HOUR 3500K, 85CRI OPERATION. PROVIDE UNSWITCHED HOT i LEG FOR VOLTAGE SENSING AND i CONTROL._. _ F2 (2) F017/835/ECO, RECESSED LENSED 2X2 TROFFER, 16 WHITE UNV RECESSED DAY—BRITE 2—LP3—G—S-2-17—R-44-- COOPER METALUX APPROVED ELECTRONIC MATCH LENS WITH 20,OOOHR, 3500K, 82 CELL PARABOLIC LOUVRE, PROVIDE AL-120 MANUFACTURER PROGRAMMED START EXISTING FIXTURES CRI MOUNTING HARDWARE FOR GYP OR ACT >10% THD CEILINGS AS REQUIRED F3 (1)CF32DT/E/IN/835/ RECESSED 6" APERTURE CIRCULAR WHITE UNV RECESSED LIGHTOLIER 8021—CCLW-56132BU COOPER APPROVED DIMMING ECO, 12,OOOHR, DOWNLIGHT WITH VERTICAL LAMP AND MANUFACTURER 3500K, 82 CRI WHITE FLANGE. PROVIDE LUTRO HI LUME DIMMING BALLAST. _ F4 (1) F032/835/XPS/ NARROW 4" RECESSED LIGHTING SYSTEM WHITE UNV RECESSED PRUDENTIAL P43-1T8-04'—BLW—TMW— PINNACLE LIGHTING APPROVED ALTERNATE PROVIDE LENGTHS PER ECO, 36,OOOHR, WITH BLADE LOUVRE WHITE SHIELDING, D1W—SC—UNV—X1 PLAN 3500K, 85CRI ASYMMETRIC TO WALL DISTRIBUTION, AND EXPOSED T—BAR MOUNTING. EMERGENCY - Type ILamp Description Finish Voltage Mounting Manufacturer Catalog Number Alternate 1 Alternate 2 Control Location Comments X1 GREEN LED INCLUDED WHITE FINISH THERMOPLASTIC EXIT WHITE UNV RECESSED EMERGILITE W--PREM—U—GX APPROVED APPROVED ROUTE UNSWITCHED SIGN WITH GREEN LETTERING. ORDER CEILING MANUFACTURER MANUFACTURER HOT LEG. MATCH FACES AND CHEVRONS AS INDICATED ON EXISTING PLAN. ISSUES AND REVISIONS NO. DATE DESCRIPTION 09.11A4 ISSUE FOR PRELIMINARY PRONG 09.22.14 ISSUE FOR 95% MEP BACKGROUNDS 10.06.14 ISSUE FOR PRICING, PERMIT & CONSTRUCTION IIIIIIIIIIIIIIkk M-E Engineers, Inc. 10055 west 43rd avenue wheat ridge, co 80033 t. 303.421.6655 /L 303.421.0331 e n g i n e e r s www.me-engineers.com °0N AAA N\ u4s� FIIJM (Moup 9055 EAGLE CLIFF ROAD CONIFER, COLORADO 80433 PH: 303,886.8499 E: saroh@ronandesigngroup.com SEAL/ SIGNATURE D� RE !s c" o ��Fss�oiv � •� � la LV WILLIAMS MIDSTREAM Solvay Chemical Building 2717 County Road 215 Parachute, Colorado 81635 2nd Floor & 1 st floor Partial SHEET TITLE: ELECTRICAL PANEL SCHEDULES :-MEET NUMBER PROJECT NUMBER7 0,03 11>arrQ.I•xi GENERAL BUILDING HEIGHTS AND AREA ACTUAL BUILDING AREA PER FLOOR: ACTUAL FLOORS - CONSTRUCTION TYPL: SPRINKLERED? ALLOWABLE AREA: ALLOWABLE FLOORS: FIRST FLOOR SECOND FLOOR: ELEVATORS. CHAPTER 10 MEANS OF EGRESS ALLOWABLE FLOORS: FIRST FLOOR 15,841 SF (FIRST FLOOR) 14,911 SF (SECOND FLOOR) 2 TYPE IIB NON SPRINKLERED 23,000 SF 3 OCCUPANCY TYPE: B- BUSINESS 15,841 SF OCCUPANCY TYPE: B- BUSINESS: 14,911 SF 1 15/841 3 OCCUPANCY TYP: B- BUSINESS 15,841 SF FIRST FLOOR APPROX. SF OCCUP. RATIO OCCUP. OCCUPANCY GROUP OFFICE SPACE 15,841 SF 1:100 159 OCC. B SECOND FLOOR OFFICE SPACE APPROX. SF 13,623 SF OCCUR RATIO 1-1100 OCCUP. 137 OCC, OCCUPANCY GROUP B MECHANICAL RM 1,288 SF 1:300 5 OCC. TOTAL 14,911 SF 202 OCC. NUMBER OF EXITS REQUIRED NUMBER OF EXITS PROVIDED EXIT WIDTH TRAVEL DISTANCE ACTUAL MAX. TRAVEL DISTAN CORRIDORS: GENERAL CCDE AND 14,911 USF 2ND FLOOR 202 TOTAL OCCUPANT LOAD FOR FLOOR 101 TOTAL OCCUPANT LOAD PER SEX *NOTE-- NEW BREAK ROOM SINKS ARE AT 34" AFF & FULLY ADA COMPLAINT. *NOTE- RESTROOMS #267 & 268 ARE BEING MADE FULLY ADA COMPLIANT. PLUMBING COUNT FIXTURES PER SEX # REOJIRED BY CODE # PROVIDED WATER CLOSETS/ URINALS 3 3-+3 MEN 3 WOMEN LAVATORIES 2 3 DRINKING FOUNTAINS 2 2 PLUMBING CODE ANALYSIS- 2ND FLOOR GENERAL NOTES 1, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ALL MATERIALS & WORKMANSHIP IN ACCORDANCE WITH ALL OF THE APPLICABLE HEALTH & SAFETY STANDARDS, BUILDING CODES & ORDINANCES. GENERAL CONTRACTOR SHALL PROVIDE- ONE YEAR WARRANTY (MINIMUM) FOR ALL WORK & MATERIALS. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSTALLING HANDRAIL EXTENSIONS AT EXISTING STAIRS AS SHOWN. GENERAL NOTES EXIT 3 03 ISSUES AND REVISIONS A NO. DATE DESCRIPTION 09.11A4 ISSUE FOR PRELIMINARY PRICING 09.22.14 ISSUE FOR 95% MEP BACKGROUNDS 10.01.14 ISSUE FOR CARPET ORDER 10.06,14 ISSUE FOR PRICING, PERMIT & CONSTRUCTION � ONN0 N� I�JES�CN CROUP 9055 EAGLE CLIFF ROAD CONIFER, COLORADO 80433 PH: 303.886.8499 E: sarah®ronandesigngroup.Com SEAL/ SIGNATURE A0F coil O'F CO Qtif 7 WILLIAMS MIDSTREAM Solvay Chemical Building 2717 County Road 215 Parachute, Colorado 81635 2nd Floor & 1st floor Partial SHEET riTLE: DOOR, FRAME, HDWR. SCHEDULE, GENERAL . NO T�.S 0. SHEET NUM � A0��1 UUUL UUMFLIAINUL FLAN 01 PROJECT NUMBER: 2014--077-00J