HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT BLRE-01-24-8495 Grand Valley Drywallers LLC New Single-family dwelling w/ attached garage 41 Eagles Ct, Parachute First Eagles Point, Lot 51 -240717211051 1 ) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.) AND 2018 I NTERNATIONAL EN ERGY CONSERVATION CODE (I.E.C.C.) 2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON PLANS REFER TO SPECIFIC ITEMS ON THIS LIST. 3) ELECTRICAL PERMITTING AND INSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL ROUGH.IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY. 4) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE DISTRICT. PLEASE REFER TO THE GARFIELD COUNTY COMMUNITY DEVELOPMENT WEBSITE FOR ADDITIONAL I N FORMATION. 5) OPEN HOLE SOTLS REPORT tS REOUTRED AT FOOTTNG TNSPECTTON AND PRTOR TO ANY CONCRETE POUR. PROVIDE COPY OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. 2,000 PSF soil bearing and including compaction report for the structural fill. 6) PRE-ENGTNEERED ROOF TRUSSES. HAVE ENGTNEERING FOR BUtLDtNG TNSPECTOR AT TtME OF FRAME INSPECTION. 7) BLOWER DOOR TEST rS REOUTRED. MUST SUBMIT BLOWER DOOR TEST REPORTTO GARFTELD COUNry COMMUNIry DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULING FINAL BUILDING INSPECTION / C.O. FINAL. 8) A LOT TMPROVEMENT CERTIF|CATE, SEALED BY A COLORADO LTCENSED SURVEYOR, tS REOUTRED AT FOUNDATION INSPECTION TO VERIFY STRUCTURE IS IN COMPLIANCE WITH MINIMUM SETBACK REOUIREMENTS / BUILDING ENVELOPE 9) PURSUANT ATTACHED RECORDED PLAT NOTE #1 1, ALL INDIVIDUAL WATER SERVICE CONNECTIONS WILL BE REOUIRED TO HAVE AN IN-HOUSE PRESSURE REDUCING VALVE INSTALLED. 1O) PURSUANT ATTACHED RECORDED PLAT NOTE #12, AN IN-HOUSE SEWAGE EJECTOR PUMP MAY BE REOUIRED ON LOT 51 DEPENDING ON THE FINISH FLOOR ELEVATION OF THE LOWER LEVELS OF THE HOME. 1 1) PURSUANT ATTACHED RECORDED PLAT NOTE #1 3 NO FENCES WILL BE ALLOWED TO BE CONSTRUCTED ON THE LOT LINE BETWEEN LOTS 51 AND 52 IN ORDER TO ALLOW UNENCUMBERED ACCESS TO THE WATER LINE INSTALLED ALONG (THOSE SUBJECT) LOT LINES. 12) PRESCRIPTIVE PATH USING THE 2018 IECC PRESCRIPTIVE TABLES HAS BEEN CHOSEN FOR ENERGY COMPLIANCE OF THIS HOME DESIGN. MANUAL J REPORT ALSO ATTACHED FOR REFERENCE. ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015 IRC TABLE m1507.3.3(1) AND (2) SHOWN ON COVER SHEET.