HomeMy WebLinkAboutSubsoils Study for Foundation DesignHngineering, fnc, CIV{T,/6HOTRCHMCAL SOIL AND FOUNDATION INVESTIGATION FOR PROPOSED DITLOW RESIDENCE SECTION 6, T5S RSOW TRACT IN SWSE LYING NWLY OF CR 24I & SELY OF EAST ELK CREEK 3683 24I COUNTY ROAD, GARFIELD COUNTY NEW CASTLE, CO 81647 PROJECT NO. 23.3713 AUGUST 25,2023 PREPARED FOR TIIE BUYER: DAVID YOUNG 3285 COUNTY ROAD 24I NEW CASTLE, CO 81647 davidg@r.andhnrechanical. conr $ *I\ siD P,O. Box 724,Eagle, CO 81631 Tel. (970) 390-0307 r.rr.nv.LKPEngineering.c,om TABLE OT CONTENTS EXECUTIVE SUMMARY SCOPE OF STUDY SITE DESCRIPTION PROPOSED CONSTRUCTION ,,.,2 ....2 ,,..2 ....J FIELD INVESTIGATION .J SUBSURFACE SOIL AND GROI.INDWATER CONDITION ,,4 FOUNDATION RECOMMENDATIONS,..... ,..,...,4 SLAB CONSTRUCTION RETAINING WALLS...... UNDERDRAIN SYSTEM 5 SITE GRADING AND DRAINAGE 6 6 7 LAWN IRRIGATION ..8 LIMITATION...................8 FIGURES LOCATION SKETCH SUBSURFACE EXPLORATION LOGS. SWELL/CONSOLIDATION TEST RESULTS .. PERIMETER DRAIN DRAWINGNO. I ....FIGURENO's1-2 .... FIGURE NO'S 3 -6 ....FIGURE NO. 7 P.O. Box 724,Eagle, CO 81631 Tel. (970) 390-A307 wwr.v,LKPEnginsering.com EXECUTIVE SUMMARY The proposed Ditlow Residence can be supported with conventional type spread footings, designed for an allowable soil bearing pressure of 1000 psf. They should construct the footings of the entire foundation on the undisturbed silty, sandy gravel with cobbles. See Foundation Recommendations. SCOPE OF STUDY This report presents the results of a subsurface Soil and Foundation Investigation for the proposed Ditlow Residence on Section 6, T5S R90W, Tract in SWSE lying NWLY of County Road 241 & SELY of East Elk Creek, 3683 241County Road, Garfield County, New Castle, CO 81647. The purpose of the subsurface soil and forurdation investigation was to determine the engineering characteristics of the foundation soil and to provide reconlmendations for the foundation design, grading, and drainage. Geologic hazard studies are outside of our scope of services. SITE DESCRTPTION The property is l0-acre parcel of land, on the west side of the road at 3683 24I County Road, Garfield County, New Castle,CO 81647, north of the town of New Castle, Garfield County, Colorado. Existing residence is within the proposed building site for the new residence, which P,O. Box 724,Eagle, CO 81631 Tel. (970) 390-0307 wr,vw.LKPEnsineerinq.cotn J will be demolished. The vegetation surounding the existing building consisted of grass. The topography of the site is steep down frorn the road and moderate to the west of the existing residence. Drainage is to the west, towards East Elk Creek. PROPOSED CONSTRUCTION We understand that the proposed residence will consist of two stories, wood frame construction, with a walkout basement on a conuete foundation. We anticipate loads to be light, typical of residential construction. If the finalized plans differ significantly from the above rurderstanding, they should notify us to reevaluate the recommendations of this report. FIELD INYESTIGATION The field investigation, conducted on August L9,2023, consisted of drilling, logging, and sampling two bores. The test bore locations are shown on Drawing No. 1. Drilling of the test borings was done with CME-45, 4-inch diameter, continuous flight power auger on a track mounted, drill rig. Soil saurples for laboratory soil analysis and observation were taken at selected intervals with a California and Standard Split Spoon Samplers, advanced with an automated 140-pound hammer, falling 30 inches. We show the soil profiles of the test borings on the Subsurface Exploration Logs, Figure No's 1 ffidz. Soil samples for laboratory soil analysis and observation were taken at selected intervals. P.O. Box 724,Eagle, CO 81631 Tel. (970) 390-0307 wwrv,LKPEngineering.com 4 SUBSURFACE SOIL AND GROUNDWATER CONDITION The soil profiles encountered in the test borings were somewhat similar. Boring No. I had few inches of topsoil over grayish silt over blocky, silty to gravelly clay over very soft slightly sandy, silt and clay with pockets of topsoil ( (possibly man-made filIor very loose, alluvium deposit) over interbedded layers of firmer silty, sandy gravel and softer, fine sand to sandy silt, and layers of sandy gravel with some cobbles of siltstone and sandstone rock, to the maximum depth explored of 20 feet. Test Boring No. 2 was drilled within the existing concrete driveway, and it had about 6 inches of concrete over interbedded layers of sandy silt" silty, sandy gravel, and slightly sandy calcareous silt with traces of gravel, over layers of firmer, calcareous, silty, gravelly sand, sandy gravel with some cobbles. and sandy silt with sparse gravel to the maximum depth explored of l9.5feet. Ground water was not encountered in either boring. We sampled the soil in the test pit at random intervals. The soil sarnples were observed, logged, and tested for natural moisture content, natural dry density, and swell-consolidation. The test results are shown on figures 3 through 6. FOUNDATION RECOMMENDATIONS The upper soils (about 6 to I feet) in test boring one, exhibited high potential for hydro- consolidation (additional settlement upon addition of water under constant pressure of l000psf). We recommend that the entire foundation excavation is extended to the finn, silty-sandy gravelly soils. The firm, gravelly soils, were encountered at about 8 feet below the existing grade in test boring one, and at about 4.5 feet below the existing grade in test boring two, The depth of the suitable soil can vary. Foundation supported on the firm, silty-sandy to sandy, gravelly soil can be designed with conventional fype spread footings, designed for a maximum ailowable soil bearing pressure of 1 000 psf. P.O. Box 724,Eagle, CO 81631 Tel. (970) 390-0307 r.rr,r,r.v.LKPEngineering.com 5 We recommend a minimum width of 16 inches for the continuous footings and? feet for the isolated footing pads. Continuous foundation walls shortld be reinforced top and bottom to span an unsupported length ofat least l0 feet. We recommend a minimum of 48 inches (or the minimum required per the local building code) of backfill cover for frost protection of the footing subsoils. The fottndation excavation should be observed by the undersigned engineer to verify that the soil condttions encountered during canstruction are as anticipated in lhis report. The fotrrdation excavation should be tree from excavation spoils, fiost, organics and standing water. We recommend proof-rolling of the foundation excavation. Soft spots detected during the proof-rolling, should be removed by overexcavation. Any overexcavation within the proposed foundation should be backfilled, in 8 inches loose level lifts and compacted to 100Yo ofthe maximum dry density and within 2percent of the optimum moisture content as determined in a laboratory from a Standard Proctor test (ASTM D-69S). A structural fill, placed under footings should be tested a qualified professional. SLAB CONSTRUCTION The natural on-site soils, exclusive of topsoil, loose silqv-gypsiferous soils, and organics, are suitable to support lightly loaded slab-on-grade construction. The subgrade for the slab-on- grade construction should be proof cornpacted to detect and remove soft spots. They should backfill overexcavated soft spots and other underslab fill with the on-site soil, free from topsoil and organics, or other suitable material, compacted to a minimum of 95 percent of the maximum standard Proctor density (ASTM D-698). Suitable material should be free from man-made fill, topsoil, organics, and rock fragments greater than 3 inches. The concrete slab should be constructed over a 4-inch layer of clean gravel consisting of - 3l4inch gravel with at least 50Yo retained on the No. 4 sieve and less than 3 percent passing the No. 200 sieve. P.O. Box 724,Eagle, CO 81631 Tel. (970) 390-0307 i.r.'u.rry,LKPEngineering.com 6 They should reinforce the concrete slab-on-grade and score control joints according to the American Concrete Institute requirenrents and per the recommendations of the designer to reduce darnage due to shrinkage. The concrete slab should be separated from the foundation walls and columns with expansion joints to allow for independent movement without causing damage. RETAINING WALLS Foundation walls retaining earth and retaining structures that are laterally supported should be designed to resist an equivalent fluid density of 60 pcf for an "at-rest" condition. Laterally unrestrained structures, retaining the on-site earth, should be designed to resist an equivalent fluid density of 40 pcf for the "active" case. Passive earth pressure of360 psfcan be used for the lateral pressure against the sides of the footings. Resistance to sliding at the bottom of the footings can be calculated based on a coefficient of friction of 0.5. Undisturbed soil or a stntctural fill cornpacted to 100 percent of the maximum dry density and within 2 percent of the optimum moisture content shall be used to resist lateral loads at the sides of the footings. The above design recofirmendations assume drained backfill conditions and a horizontal backfill surf'ace. Surcharge loading due to adjacent structures, weight of temporary stored construction materials and equipment, inclined backfill and hydrostatic pressure due to undrained backfill should be incorporated in the design. They should try to prevent the buildup of hydrostatic pressure behind the retaining wall. UNDERDRAIN SYSTEM To reduce the risk of surface water infiltrating the foundation subsoil, we recommend P.O. Box 724,EagIe, CO 81631 Tel. (970) 390-0307 wwr.v"LKPEnqineerinq.com 7 installation of a foundation perimeter drain (see Figure No. 7). The foundation perimeter drain should consist of a 4-inch diameter, perforated pipe, sloped to a suitable gravity orttlet, or to a sump pump location, at a I 14 inch per foot for flexible or at a 118 of an inch for rigid pipe. The bottom of the trench adjacent to the footing should be lined with a polyethylene moisture barrier glued to the foundation wall. The drain pipe should be covered with a minimum of 6 inches of - 3l4-inchfree-draining granular material. Geotextile (Mirafi 140N or equivalent) should be used to cover the free-draining gravel to prevent siltation and clogging of the drain. The backfill above the drain should be granular material to within 2 feet of the ground surface to prevent a buildup of hydrostatic pressure. SITE GRADTNG AND DRATNAGE The following recommendations are general. Exterior backfill should be compacted at or near the optimum moisture content to at least 95Yo of the maximum standard Proctor density under pavement, sidewalk, and patio areas and to at least 90% of the maximum standard Proctor density under landscaped areas. They should use mechanical methods of compaction. Do not puddle the foundation excavation. The site surrounding the building structure should slope away from the building in all directions. A minimum of l2 inches in the first 1 0 feet is recomfiiended in unpaved areas, and three inches in the first l0 feet in paved areas. The top of the granular foundation backfill should be covered with a minimum of I foot of relatively impervious filIto reduce the potential of surface water infiltrating the foundation subsoils. Surface water naturally draining toward the proposed building site should be diverted around and away from it by means of drainage swales or other approved methods. The roof drains and downspouts should extend and discharge beyond the limits of the backfill. P.O. Box 724,Eagle, CO 81631 Tel. (970) 390-0307 s,rvrv.LKPEngineering.com 8 LAW}[ IRRIGATION It is not recornmended to introduce excess water to the foundation soils by installing sprinkler systems next to the building. The installation of the sprinkler heads should ensure that the spray from tle heads will not fall within l0 feet of foundation walls, porcheso or patio slabs. Lawn irrigation must be controlled. LIMITATION This report has been prepared according to locally accepted Professional Geotechnicai Engineering standards for similar methods of testing and soil conditions at this time. There is no other warranty either expressed or implied. The findings and recommendations of this report are based on field exploration, laboratory testing of samples obtained at the specific locations shown on the Location Sketch, Drawing No.1 and on assumptions stated in the report. Soil conditions at other locations may vary, which may not become evident until the foundation excavation is completed. If soil or water conditions seem different from those described in this report we should be contacted immediately to reevaluate the recofirmendations of this report. We are not responsible for technical interpretation by cthers of the data presented in this report. This report has been prepared for the exclusive use of Dave Young, for the specific application of the proposed Ditlow Residence. at 3683 241 County Road, Garfield County, New Castle, CO 81647. Sincerely, LKP ENGINEERING,INC. 4x h\ LuizaPetrovska, PE J:\ WP X4-LKP\ 2023\23-37 I3SL'I'-SND-CL-GRV-IIORL.DOCX P.O. Box 724,Eagle, CO 81631 Tel. (970) 390-0307 www.LKPEngineerinq.com B-1 BI2 NOTE: THE LOCATION OF THE TEST EORINGS lS APPROXIMATE, IT IS NOT BASED ON A SURVEY, LKP CML,/GEOTECTTNICAL Engineering, Inc. P.0. Box 724, Eaqla, CO 81651 T6l (970) Jso-0J07 www.LKPEngineoring.com LOCATION SKETCH 3683 241 COUNTY ROAD NEW CASTLE GARFIELD COUNTY. COLORADO PRoJEcrNo: 23-g713 scALE: _ 1,,= 30, DRAWNG NO.: 1 DATE OBSER\ED: AUGUST 19, 2025 ELEVATION: BORINC NO. 1 DEPTH FEET BLOWS PER Ff, s Y M B o L s A M P L E DESCRPNON OF MA|ERIAL AND SAMPIE LOCAN$,I UBffiAIORY TEST RESULIS REMARKS -6 -10 -16 2fi Et/|2 5/2 26n2 tJl2 7/6 t6//6 t] tr tr I I Few inchas of Topsoil ovar graylsh silt over blocky, silty to grovelly clay over very soft slightly sondy, silt and cloy with pockets of topsoil lnterbadded layers of firmer silty, sandy grovel and soften flne sand to sandy sllt, and lalnrs of sandy gravel wlth some cobbles, siltstone and sondstone rock fragments DD- 90.2 pcf MC= ll,7 t DD= 78.1 pcf MC- 15.8 f (possibly man-made fill or very loose, alluvium deposit) grinding grinding Bottom of boring @ 2O feet No Ground Vfoter Encountered I,EGEND: Cl - Z-lnch O,D, Callfomla Llncr SomplcI - Spllt Spaon 21n2 - Drlw cample blov count lndlcatcc that 21 blows of a llo-pound hammer folllng 3O lnchae vcre requlred to drlvc the Callfomla or thc Sllt Spoon Sampler 12 lnches, DD - Naturut Dry Dcnsity (pcf)MC - Naturol Molsturc Contcnt -2AO - Pcrccnt Posslng No, 200U - Llquld LlmltPl * Plastlclty lndcxCW - Ground watcr Q Slanr NOTE: fhc soll tronsltlons arc approximota raprascntatlon of tha soll condltlone ln the tcet borlngc. Soll samples ara obtalncd at sdact lntervols and tha lalnrs ore fntarpolotad, Varlatlona may exlst, I,TP ENGINEERING, INC.SUBST]RFACE SIPTORATION tOC FxI,':Si',f,lt 23-371J IFEEIA,' DATE OBSERIED: AUGUST 19, 2025 ELEVATION: BORING NO. 2 DEPTH ffET ELOWS PER N. s Y H B o L s A M P L E DESCRFNON OF HA|ERIAL AND SAMPLE LCICANON UBORATORY IEST RESULIS REUARKS -t _t0 _15 _m ton2 t5n2 Jen2 t3/6 l6r/6 tr About 6 lnches of concrete over interbedded lalters of sandy silt, sllty, sandy grovel, ond sllghtly sondy calcoreous silt with traces of grovel Loyers of firmer, calcoreous, sllty, gravelly sand, sandy gravel with some cobbles, ond sandy silt with spdrse gravel DD- 97.7 pcf MC= 5.5 Z DD= 94,5 pcf MC= 2.9 t DD= 114.7 pcf MC- 3.9 X grinding grinding Bottom of boring @ 19.5 feet No Cround Water Encountered I,EGEND: tr - Z-lnch O.D. Callfomlq Llncr SamplcI - Spllt Spoon 24n2 - Drlw aampla blott count. lndlcatas that 24 blowe of a llo*pound hommcr falllng 30 lnchcs ncrc raqulrcd to drlw tha Collfornla or thc Spllt Spoon Sampl* 12 lnchcs. DD - Notural Dry Dcnslty (pcf) MC - Notural Moleturc Contqt -200 - Parcant Paaslng No. 200U - Llquld LlmltPl - Plaetlclty lndcxeW - Ground watar (x) Slerc NOTE: The soll traneltlons ara approxlmotc repreacntotlon of tha soll condltlons ln thc test borlnga Soll samplcs arc obtolned of sclcct lntcrwls ond thc lolars orc lntcrpototad, Vorlotlons moy cxlct. I,XP ENGINAAnING, INC.suBsunFAca gxPtoRAnoN toc Ffreflcf tA!2J-37tJ FNF'8,2 Exponsion IINI+I(t!Io)I Compression Z GILlIaI(oI a I N I Gt I + I ('t I Ol I c)\oo-d*-i*-=(rj-:Q :xP: ur--s!--r\sori\ --,i{ - lrl 8u ;H \ s a !\ B B tIttr H Ir\ I F {alr a oa ==toooa+*f,\ \€ s_ s- d- $€3 5S$ sFs iSsi* il llls l,=q -(OO:.. Sro\\rd q tl\(roo d --.F T ciI so l.ro a N do $ $ros g stff cr) =o I oof,oo a_a+ o3 <o'(D To(Dt (t, ({ lllllllitl /O0MPRESSION WHEN V1ETTED UNDER CONSTANT PRESSURE OF IOOO PSF ttttiitlll \ \ \ \ \ \ \ \ \ ta0ta APPLIED PRESSURE - ksf 1.00.1 From: Borlng I at 4 feet pcf percent Sample of : Ton, sllty cloy ond topsoil Naturol Dry Unit hteight : 78,1 Ndtural Maisture Content : l1,E IKP Englnadng lnc,Swell - Consolidation Test Results 2J-3713 4 No,: 0 tro o Ro $l{ -1 -2 -3 -4 -6 -7 N -8 -o -10 -l I -12 -1J -14 -15 -16 I 0 -l -2 *3 -4 -5 -6 -7 -8 -9 -to -11 -12 -13 -14 -15 -16 q .9 at,so q- Ur bt c .e(n tDo q- EI .oOMPRESSION YI+iEN WETTED UNDER CONSTANT PRESSURE OF IAOO PSFitllilllrl \ \ \ \ \ \ \ \ \ 0.1 1.0 to 100 APPLIED PRESSURE - kef Sample of : Tan, sllghtly clayey, sandy sllt Natural Dry Unlt htelght : 97.7 pcf Naturol Moisture Content = S.S percent From: Eoring 2 at 3 feet lJ# Englncslng, lna Swell - Consolidation lesf Resu/fs 23-3713 5 0 s .etlc(t a..r( KJ bt co lagr !u a- Eo() J 2 3 2 -l -2 -J -4 0 c .a v,co ,io bt t.e v,ut Pa- Eo$ -t -2 -3 -4 IKP Englnatlng,23-37t3Swell - Consolidation Test Results 6 .COMPRESSION W|EN WETTED UNDER CONSTANT PRESSURE OF |AOO PSFl r til|t l l 0.1 t.o to 100 APPLIED PRESSURE - ksf Sample of: Tan, calcareous, sondy silt Natural Dry Unit Vleight 94.5 Natural Moisture Content = 2,9 From: Borlng No, 2 at I fect pcf percent t t|llt t l ..oOMPRESSION W4EN WET|ED UNDER CONSTANT PRESSURE OF |OOO PSF I 1.0 to APPLIED PRESSURE - ksf o.t to0 Sample of: Ton, gravelly sllty sond Ndtural Dry Unit Vlelght : Natural Moisture Content :n4.7 3.9 pcf percent From: Boring No. 2 of 13 feet D t D' D ' 'D , .D. D r I DF', -*t s 6R\ 3,\)\ .D t D AWAY FROM BUILDING R BACKFILL WITH A MINIMUM OF ONE FOOT OF REISTIVELY IMPERVIOUg SOIL FABRTC (MrRAF| 14ON OR EQUIVALENT) US 3/4.INCH DIAMETER, COARSE, CLEAN CRUSH ROCK 30 MIL MINIMUM THICKNESS,NCH DIAMETER PERFORATED PIPE SLOPED TO PLASTIC LINER, GLUED TO A DAYLIGHT LOCATION AWAY FROM THE FOUNDATION AT 1/4.INCH PER FOOT FOR FLEXIBLE AND 1/8.INCH MINIMUM FOR RIGID PIPE FOUNDATION WALL cffrL/cEoTEcHMCAr Engineering, Inc. P,O, Box 724, Eogle, CO 81651 LKP Ter (e70)390-0J07 www.LKPEngineering.com PENIMETER DNAIN 368?241 COUNW ROAD NEW CASTLE GARFIELD COUNTY, COLORADO FRQECT No': zg-a71g scALE N.T.s. 7 |IGU'<L NU.: