HomeMy WebLinkAboutOWTS Installation Observations 02.27.2024CBO Inc.
129 Cains Lane
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
February 27, 2024 Project No. C1842
Ziska Childs
ziska@ziskachilds.com
Onsite Wastewater Treatment System (OWTS) Installation Observations
284 CR 102
Garfield County, Colorado
OWTS Permit SEPT-8439
Ziska,
CBO Inc. observed the installation of the onsite wastewater treatment system (OWTS) on February 1,
2024 for the subject property. Greg Freeman installed the system.
The OWTS design is based on 3-bedrooms. An average daily wastewater flow of 450 GPD was used.
The existing septic tank was abandoned by pumping the septic tank, crushing the tank, and filling the
void with onsite material. The existing soil treatment area (STA) was abandoned in place.
The existing cast iron sewer line was replaced. A new, 4-inch diameter SDR-35 sewer line with a double-
sweep clean out and a minimum 2% grade to the septic tank was installed.
The system installation included a 1000-gallon, two-compartment Roth® poly septic tank with an
Orenco® Biotube effluent filter on the outlet tee. This filter must be cleaned annually, or as needed.
Risers bring the manhole lids to grade for access.
Effluent gravity flows to a distribution box, and then to four gravelless chamber trenches. The distribution
box was accessible from grade with flow equalizers installed on each outlet pipe in the distribution box to
assure equal flow to each trench.
Each trench consists of 14 ‘Quick 4’ Plus Standard Infiltrator® chambers for a total of 56 chambers and
672 square feet of infiltrative area. There was at least 4-feet of undisturbed soil between each trench.
Inspection ports were installed at the beginning and end of each trench. Ports may be cut to grade and
placed in sprinkler boxes for access.
The OWTS was generally installed according to specifications. This observation is not a guarantee of
workmanship and/or parts and materials. CBO Inc. should be notified if changes are made to the OWTS
in the future. Any additional OWTS construction must be according to the county regulations.
LIMITS: Observations are limited to components that are visible at the time of the inspection. The installer must
have documented and demonstrated knowledge of the requirements and regulations of the county in
which they are working. The quality of the installation is dependent on the expertise of the installer, soil
type, and weather conditions.
Please call with questions.
Sincerely,
CBO Inc.
Carla Ostberg, MPH, REHS
View of sewer line to house prior to installation / installation of sewer line and clean out
Sewer line from house to septic tank / sewer line enters side of septic tank
Septic tank Effluent filter
Distribution box Trench installation
Distribution box
Distribution box and trenches
Lowest trench below tree
Garfield County Public Health
2014 Blake Ave.
Glenwood Springs, CO 81601
Phone: (970) 945‐6614 ext. 8150
For inspections, call: 970‐945‐6614 ext. 8150 and call the Design Engineer, if applicable
Project Address: 284 County Road 102, Carbondale, CO 81623 Parcel No.: _239120300132
Owner Name: Ziska Childs Owner Email: ziska@ziskachilds.com
Designed By: CBO, Inc. Designer Phone: (970) 309‐5259
Contractor: Greg Freeman Contractor Phone: (585) 797‐3874
Number of Bedrooms: 3 Minimum Tank Capacity: 1,000‐gallon Minimum Absorption: 630 ft2
OWTS PERMIT
KEEP AVAILABLE AT PROJECT SITE
Permit Number _SEPT‐8439_______________________________
Permit Type X New X Repair X Remodel/addition X Tank only
Issue Date _11/29/2023____________________ Expiration Date_11/29/2024_________________
Permit Conditions:
This OWTS Permit is approved on the condition of compliance with the report and design as
submitted by CBO, Inc dated November 11, 2023. Changes to the design and permit must be
approved by Garfield County Public Health and the designer prior to construction.
The new OWTS will serve an existing 3‐bedroom residence. The new OWTS will include a new 1,000‐
gallon two compartment septic tank with an effluent filter installed in the outlet tee of the tank with
access to grade provided. Effluent will gravity flow to a new distribution box set level with access to
grade that will distribute effluent to 672 ft2 of STA. The new STA will consist of four gravelless
chamber trenches consisting of 14 Infiltrator Quick4 chambers per trench (56 chambers total).
Inspection ports will be installed at each end of each trench. Maintain all setbacks and elevations as
designed.
Contact the designer and Garfield County Public Health at least 48 hours prior to requesting final
inspection of the installed system prior to backfill. NO OWTS COMPONENT SHALL BE BACKFILED
WITHOUT PRIOR APPROVAL FROM GARFIELD COUNTY PUBLIC HEALTH AND THE DESIGNER.
Agreement
All installations must comply with all requirements of the Garfield County OWTS regulations
including but not limited to the conditions specified above.
In consideration of the issuance of the permit, the applicant hereby agrees to comply with all
laws and regulations related to the zoning, location, construction, and erection of the proposed
OWTS and associated structures for which this permit is granted. The applicant further agrees
that if the above said regulations are not fully complied with in the zoning, location, erection,
and construction of the above described OWTS and structure, the permit may then be revoked
by notice from the Health Department and immediately become null and void.
The issuance of a permit and specifications of terms and conditions therein will not constitute
assumption of liability, nor create presumption that the local public health agency or its
employees may be liable for the failure or malfunctioning of any system. Permit issuance will
not constitute a certification that the system, the equipment used in the system, or any
component used for system operation will ensure continuous compliance with the provision of
the OWTS Act, the regulations adopted thereunder, or any terms and conditions of a permit.
Permit Approval
Plans and specifications for the proposed OWTS have been reviewed and are considered
satisfactory. Permission is hereby given to the property owner(s) to perform the work indicated
in accordance with the Garfield County OWTS Regulation. This Permit will expire 1 year from
the date of issuance unless construction on the system has commenced. An "as‐built" drawing
must be submitted and inspection of the system must be completed by GCPH before final
approval of the system will be issued.
11/29/2023
Issued By: Garfield County Environmental Health
Department
Date
832‐R‐13‐002