HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PE RMIT
BLRE-1 1-23-8429
ACE OF TRADES GC, LLC
New Single-family dwelling w/ attached garage
244 Limberpine Circle, Parachute
Canyon View, Ph 1, Blk 1 , Lot29
1) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.)AND 2018
I NTERNATIONAL EN ERGY CONSERVATION CODE ( I.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNTY BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERMtTTtNG AND TNSPECTIONS BY COLORADO STATE ELECTRIC BOARD. ELECTRICAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINALAPPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE RECOMMENDATIONS PER COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. PLEASEREFERTOTHEGARFIELDCOUNTYCOMMUNIryDEVELOPMENTWEBSITEFOR
ADDITIONAL I N FORMATION.
s) opEN HOLE SOTLS REPORT - tNCLUDTNG COMPACTTON REPORT FOR 24 INCHES OF COMPACTED
FILL --IS REOUIRED AT FOOTING INSPECTION AND PRIOR TO ANY CONCRETE POUR. PROVIDE COPY
OF GEOTECHNICAL ENGINEERS REPORT TO THE BUILDING INSPECTOR. 1,500 PSF soil bearing.
6) PRE-ENGINEERED ROOF TRUSSES. HAVE ENGINEERING FOR BUILDING INSPECTOR AT TIME OF
FRAME INSPECTION.
7) BLOWER DOOR TEST tS REOU|RED. MUST SUBMIT BLOWER DOOR TEST REPORT TO GARFIELD
COUNTY COMMUNITY DEVELOPMENT DEPT. OFFICE PRIOR TO SCHEDULINC FINAL BUILDING
INSPECTION / C.O. FINAL
8) A LOT TMPROVEMENT CERT|FICATE, SEALED BY A COLORADO LTCENSED SURVEYOR, lS REOUIRED AT
FOUNDATION INSPECTION TO VERIFY STRUCTURE IS IN COMPLIANCE WITH MINIMUM SETBACK
REOUIREMENTS / BUILDING ENVELOPE.
9) PRESCR|pTtVE PATH (UStNG 2018 rECC TABLE R402.1.2) lS CHOSEN FOR ENERGY COMPLIANCE OF
THIS HOME DESIGN. MANUAL J REPORT ATTACHED FOR REFERENCE.
ALL NEW HOMES TO HAVE WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM INSTALLED (2015
IRC TABLE m1507.3.3(1)AND (2) SHOWN ON COVER SHEET.
10) wHEREVER LESS THAN 10 FT TO ADJACENT LOT 30 AND LOT 28, AND WHEREVER ROOF EAVES ARE
MORE THAN / EOUAL TO 2 FT TO LESS THAN 5 FT TO THE MIDPOINT BETWEEN ADJACENT LOTS,
ARCHITECT OF RECORD SHALL SUPPLY SUPPLEMENTAL CUT SHEET ON PROJECTIONS WITH FIRE.
RESISTANCE RATED DETAIL FOR ROOF EAVES = "1 HOUR ON THE UNDERSIDE".
coNDtTtoN€ otr
-g(zf
I
l€Blblr
6UE-tl-z
Lot 30
Concrete Only
a\
%c\"q;o.
4
r$
+
5 N
Lot 28
Graphic Scale
0' 10' 20'40'
PRELIM
2-Car
Garage
244 Limberpine Cir
Lot 29
SITE PLAN LOT 29 244 LIMBERPINE CIRCLE CANYON VIEW SUBDIVISION 1211912023 SCALE: 1" = 20'-0"
4.8) ryHEREVER LEss rHAN 10 FT To ADJAcENT Lor 30 AND Lor 28, AND wHEReven ROOF EAVES nne
MORE THAN / EqUAL TO 2 FT TO LESS THAN 5 FT TO THE MIDPOINT BETWEEN ADJACENT LOTS, ARCHITECT
SHALL SUPPLY SUPPLEMENTAL CUT SHEET ON PROJECTIONS WITH FIRE-RESIDENTAIL RATED DETAIL FOR
ROOF EAVES = "1 HOUR ON THE UNDERSIDE"'