HomeMy WebLinkAboutSpec SheetItem # lM-{530-2CP {53O Gallon Turo Gompartment lnfiltratol@ Poly Tank 61 TANK TOP HALF CONTINUOUS EI.ASTOMETRIC GASKET 175.6'TANK INTERIOR SEAM CLIP (86)TOP VIEW AIJGI{I,CNT Dol'EL(40)TANK BOTTOM HALF 24'ACCESSPORT Tallkhdu&pffi wTH LOCKTNG LrD (3)@ tvttO-XeTnTSEAM SECTION DETAIL OUTLET TEE 2A TOTAL VOL 1A TOTAL VOL 5u SIDE VIEW SEAM CLIP r Compliont with CSA ond IAPMO Stondordso PVC risers ovoilobleo Secondory sofety screen ovoiloble with PVC riserr Moximum buriol depth is 48"o Minumum buriol depth is 6"e Tonk is not roted for vehiculor troffic loodingr Exterior of monhole cover includes the following worning: "DANGER DO NOT ENTER: POISON GASES" LIFTING STRAP (rYPrcrl) END VIEW ffir,rr**1gt' t[nAlor$gtatc. Digging Specs l I n vert Dimensions Net Weight Net Workin I I I l I ii r Length i Width irzs.o" I st.t";l Comp.p. 16' Long x 7' Wide 45" below inlet lnlet Outlet 44" Height 54.5"47"501 lbs.1006 gol 503 gol 1509 9ol tlo o €oet o o a- O .=t o o a:O-t FIBERGLASS SUPPORT l" WALL ,f" SLOT VALLEY PRTCASI, W&r& Wastewftr o Systems o Pmducils InG. o SeMce (zig) a95{764 msooRd317 P.O. Bo(95 Farc f/19) g#grzt B'ffivl$a' @81z1 Webrlb: www.vallelprcretom Emall : fron6eelc@nlle1ryrcmtom Double Walled PVG Riser & Lid Options Poly Lid (Static load tested to 5000lbs)r Skid resistance surfacer Available in green. Highest level of UV Probction induded. lncludes a bam gasket fur airtight and watertight appl icationsr lncludes square drive scr€ws b disoounage unauthorized enty. lnsulation panels achieve R-10 insulation raling 2' ol lnsulation Standard Orenco @ DuraFiber* Access Lids (FLD) Not rsoommended br vehicular haffic A" and 30'Diamebrs. Solid, resin-infused fiberglass oonstuction. 20,00G1b brcaking sbength. Standard green or broum oolorso Available with or without urefrrane lid gasket. Available with carbon filhation. 4 stainless steel flathead socket cap scrows & hex key wrendr. lnsulated lids available - 2'or4" Double Walled PVC Riser . Available in 24' and 30" Diamebro Cut to lengfrro Sold in +l- 2" incremenb. Must be cut between ribs VALLEY PRtCASflrnc. oseMe (719) 395€7G4 aISOo Rd'317 P.O. Bo(95 Farc (/19)ggf'37n BHEVISa' @81?.1 Webclb: vYww.valleyprcetorr Ermll : fronUck@lralleyprccastom Water & Wastewater o Systems o Prcducils Residential Biotube' Eflluent Filters Applications Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic tanks and have a lifetime warranry. They prevent large solids from leaving the tank, dramatically improving wastewater qualiry and extending the life of residential drainfields. 4-in. (100-mm) Biotube Effluent Fiher t 4-in. (1 00-mm) Biotube Jr. (4-in. Biotube carridge auail- able separateQ as Insert Fiber) 8-in. (200-mm) Base Inlet Fiber 4-in. (100-mm) Insert Fiher I o J I I Orencoi superior efrluentfibers resist cloging better than all other brands. Our stan- dard, full-sized 4-in. (100-mm) Biotube Effluent Fiber prouides maximum long-term protection in a complete package, with housing. Our 4-in. (100-mm) BiotubeJr., at half the size of our standard model, has more f her"ing capacity than the full-sized f bers sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Fiber is ideal. Andfor lou-profle tanks, therei the Base Inlet Fiber. * Covered by patent numbers 5,492,635 and 4,439,323 To Order Call your nearest Orenco Systems@, Inc. distributor. For nearest distribu- tor, ca.ll Orenco at 800-348-9843 or go to www.orenco.com and click on "Distributor Locator. " APS-FT-1 Bev.3.4 O 1lil0 0renco Systems@, lnc. Standard Features & Benefits . Has 5-10 times more flow area than other brands, so lasts many times longer between clean- ings, increasing homeowner satlsfaction . lnstalls in min- utes inside new or existing tanks; extendible tee handle for easy removal 0ptional Features & Benef its . Alarm available, to signal the need for c lea ning . Flow modulating discharge orifices available to limit flow rate leaving tank, mitigat- ing surges and increasing retention time . Custom and commercial sizes available Easyto clean by simply hosing off whenever the tank needs pumping Removes about two-thirds of sus- pended solids, on average, extending drainfield life Corrosion-proof construction, to ensure long life Lifetime warranty o o o a Biotube Filtering Process Effluent from the relatively clear zone of the septic tank, between the scum and sludge layers, horizontally enters the Biotube Effluent Filter. Effluent then enters the annular space between the housing and the Biotubes, utilizing the Biotubes'entire surface for filtering. Particles larger than the Biotubes mesh are prevented from leaving the tank. , , OrencoSystems" lncorporated Lltanging tfu Vh1, 1/1v Wortd DoesVhstcttatr' a\-/a *.G www.otenGo.com Nomenclatures 4-in. Biotube Filter (standard) FrIf 04!!-!IE loo,,on* Blank = Filter diameter (inches) W = fitsType 3034 outlet pipe S = fits Schedule 40 outlet pjpe no optionsM = flow modulation plate installedA = float bracket attached Cartridge height:28" and 36" are standard Housing height: 36" and 44" are standard 0ptions:A = float bracket FS = 2" outlet orifice FSO = 2" outlet orifice and overflow plate. Base inlet model Cartridge height: 14" standard Housing height: 22" standard Filter diameter (inches) 8-in. Biotube Filter (base intetmodel) FT 08 22- 14 B Blank = 1/8" filtrationP = 1/16" filtration Biotube effluent lilter series 08 =8" Blank = 1/S" filtrationP = 1/l6" filtration . Also available with coupling and sleeve as a "kit": FI-oVERFLOWKIT 4-in. Biotub€ Jf. (includes cartridge and housing) FT J TTO+ Tg--T*onr, Blank = Biotube effluent Iilter series no options = llow modulation plate installed = float bracket attached M A S Cartridge height (inches) Filter diameter (inches) fits Type 3034 outlet tee fits Schedule 40 outlet tee 4-in. Biotube Filter lnsert (cartridse onty) FTi 0418- Junior series Biotube effluent lilter series Blank = 1/S" filtralionP = 1/16" filtration Blank = 1/8" filtrationP = 1/16" filtration f For customized options (e.9., NC indicates N0rth Carolina regions) W = fits Type 3034 outlet tee S = fits Schedule 40 outlet tee Cartridge height (inches) Filter diameter (inches) lnsert Biotube effluent lilter series Distributed By: 4-in. Biotube Effluent Filter Extendible PVC handle Stainless steel set screws Top seal plate Air vents Biotube@ filter cartridge Solid base Filter housing 4-in. Biotube Jn Tank wall Riser wall POLYLOK DISTRIBUTION BOX, RISERS, AND LID uD-BOX 0 & UDAOX I D.BOX SEAL (E1'BYDS(CffiWm.l a3EA3) 16',SIDE CUT OUT TOACCEPT POLYLOK SEAL NO.3001 TEAR OUT FOR 4'SDR-35 0R scHD40 NOTTOSCAIE UD.BOX 6'RISER ROTO-FLOW4' I 6u i UD.BOX 12'RISER NOTTOSCALE POLYLOCK EOUATIZER 'v-NoTcH'wElR 1 ${ PEts 8Ef ITVEIi{G RIBS PR(n'IDE FRICTbN FITFORAI.f PIFEID #tl & 20'GOVER FOR RISER & DAOX ito7T0scArE GASKETED SEAL ON LID & RISER \/ Waler & Waebrraler o Sygteme r Ptoduds (zr9) 395{264 moo Rd317 P.O. Bo(ms Fu: f/lg) 3gf;37n B'HEvlda' @812,J.1 Webcb: www.valleyprcetom Emall : fron6eok@valleyprccastomE PRtCASfrInc. oseMoe ffi A m A HS s# Ouick4 Plus All-in-One Periscope Ouick4 Plus Standard Chamber Ouick4 Plus All-in-One 12 Endcap Center Structural Columns The Ouick4 Plus Standard Chamber offers maximum strength through its two center structural columns, This chamber can be installed in a 36-inch-wide trench, Like the original line of Ouick4 chambers, it offers advanced contouring capability with its Contour Swivel ConnectionrM which permits '1O-degree turns, right and left. lt is also available in four-foot lengths to provide optimal installation flexibility. The Ouick4 Plus All-in-One 12 Endcap, and the Ouick4 Periscope are available with this chamber, providing increased flexibility in system configurations, Quick4 Plus Standard Chamber o Two center structural columns offer increased stability and superlor strength o Advanced contouring connections r Latching mechanism allows for quick installation o Four-foot chamber lengths are easy to handle and install . Supports wheel loads of 16,000 lbs/axle with 12" of cover Quick4 Plus All-in-One 12 Endcap . May be used at the end of chamber row for an inlet/ outlet or can be installed mid-trench o Mid-trench connection feature allows construction of chamber rows with center feed, as an alternative to inletting at the ends of chamber rows o Center-feed connection allows for easy installation of serial distribution systems . Pipe connection options rnclude sides, ends or top Quick4 Plus All-in-One Periscope o Allows for raised invert installations . l BOo directional inletting o Twelve inch raised inverl great for serial applications Vuick4.fry !t:; Ouick4 Plus Standard Chamber Side and End Views 48" (EFFECTIVE LENGTH) Quick4 Plus All-in-One 12 Encap Front, Side and End Views 't't.2" 13" 34" 12' 5.3'INVERT8'INVERT i Quick4 Plus All-in-One Periscope 8'INVERT 33' OUICK4 PLUS ALL-IN.ONE (350"SwrvE[ ) m [,] OUICK4 PLUS ALLIN.ONE 12 ENDCAP 6' 12.7'INVERT 5' Ouick4 Plus Standard Chamber Specifications Size(WxLxH)34" x 530 x 12" (86 cm x'135 cm x 31 cm)lnvert Height 0,6o, 5.3u, 8,Oo, 12.7', (1.5 cm, 8.4 cm, 18.5 cm, 22,6 cn)Effective Length ...,48" (1 22 cm) INFILTRATOR SYSTEMS, INC. STANDARD LIMITED WARRANTY (a) The structural integrity of each chamber, end plate, wedge and other accessory manufactured by lnliltrator ( "Units"), when installed and operated in a leachfield of an onsite septic system in accordance with lnfiltratols instructions, is warranted to the original purchaser ("Holder") against defective materials and workmanship for one year from the date that the septic permit is issued for the septic system containing the Units; provided, however, that if a septic permit is not required by applicable law, the warranty period will begin upon the date that installation of the septic system commences. To exercise its warranty rights, Holder must notify lnfiltrator in writing at its Corporate Headquarters in Old Saybrook, Connecticut within fifteen (15) days of the alleged defect. lnfiltrator will supply replacement Units for Units determined by lnfiltrator to be covered by this Limited Warranty. lnfiltrator's liability specjfically excludes the cost of removal and/or installation ol the Units. (b)THE LIMITED WARHANTY AND REMEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE. THERE ARE NO OTHER WAFRANTIES WITH RESPECT TO THE UNITS, INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOB A PAFTICULAR PURPOSE (c) This Limited Warranty shall be void if any part of the chamber system is manufactured by anyone other than lnfiltrator. The Limited Watranty does not extend to incidental, consequential, special or indjrect damages. lnfiltrator shall not be liable for penalties or liquidated damages, including loss of production and profits, labor and materials, overhead costs, or other losses or expenses incurred by the Holder or any third party. Specilically excluded {rom Limited Warranty coverage are damage to the Units due to ordinary wear and tear, alteration, accident, misuse, abuse or neglect of the Unjtst the Units being subjected to vehicle traffic or other conditions which are not permitted by the installation instructions; failure to maintain the minimum ground covers set forth in the installation instructions; the placement of improper materials into the system containing the Unitsi failure of the Units or the septic system due to improper siting or improper sizing, excessive water usage, improper grease disposal, or improper operation; or any other event not caused by lnfiltrator. This Limited Warranty shall be void if the Holder fails to comply with all of the terms set forth in this Limited Watranty. Further, in no event shall lnfiltrator be responsible lor any loss or damage to the Holder, the Units, or any third party resulting from installation or shipment, or from any product liability claims ot Holder or any third party. For this Limited Warranty to apply, the Units must be installed in accordance with all site conditions required by state and local codes; all other applicable laws; and lntiltratofs installation instructions.800.221 .4436 www. inf i ltratorsystems.com(d) No representative of lnfiltrator has the authority to change or extend this Limited Watranty. No warranty applies to any party other than the original Holder. The above represents the Standard Limited Watranty offered by lnfiltrator. A limited number of states and counties have different warranty requirements. Any purchaser of Units should contact lnfiltrator's Corporate Headquarters in Old Saybrook, Connecticut, prior to such purchase, to obtain a copy of the applicable warranty, and should carefully read that warranty prior to the purchase of Units. W- IN FILTRATOR' systems inc. 6 Business Park Road r P.O. Box 768 Old Saybrook, CT 06475 860.577.7000 . FM 860,577.7001 . THE OUICK4@ PLUS STANDARD CHAMBER Fsr technical assistance, installation instructions or customer serrice, call lnfiltrator Syetems at 800.221.4486 U.S. Patents: 4,759,661 i 5,O17 ,041 5,1 56,488; 5,336,01 7; 5,401 ,'1 1 6i 5,401,459; 5,51 1 ,903; 5,71 6,1 63; 5,588,778; 5,839,844 Canadian Patentsj 1,329,9591 2,004,564 Other patents pending. is a registered trademark in Mexico. Contour Swivel Connection is a trademark of lnfiltrator Systems lnc. O 2009 lnfiltrator Systems lnc. Printed in U.S.A.PLUS051010tst-2