HomeMy WebLinkAboutSpec SheetItem #
lM-{530-2CP
{53O Gallon Turo Gompartment
lnfiltratol@ Poly Tank
61
TANK TOP
HALF
CONTINUOUS
EI.ASTOMETRIC
GASKET
175.6'TANK
INTERIOR SEAM CLIP
(86)TOP VIEW
AIJGI{I,CNT
Dol'EL(40)TANK BOTTOM
HALF
24'ACCESSPORT Tallkhdu&pffi
wTH LOCKTNG LrD (3)@ tvttO-XeTnTSEAM SECTION DETAIL
OUTLET TEE
2A TOTAL VOL 1A TOTAL VOL
5u
SIDE VIEW
SEAM CLIP
r Compliont with CSA ond IAPMO Stondordso PVC risers ovoilobleo Secondory sofety screen ovoiloble with
PVC riserr Moximum buriol depth is 48"o Minumum buriol depth is 6"e Tonk is not roted for vehiculor troffic
loodingr Exterior of monhole cover includes the
following worning: "DANGER DO NOT
ENTER: POISON GASES"
LIFTING STRAP
(rYPrcrl)
END VIEW
ffir,rr**1gt'
t[nAlor$gtatc.
Digging Specs l I n vert Dimensions Net
Weight
Net Workin
I
I
I
l
I
ii
r Length i Width
irzs.o" I st.t";l
Comp.p.
16' Long x 7' Wide
45" below inlet
lnlet Outlet
44"
Height
54.5"47"501 lbs.1006 gol 503 gol 1509 9ol
tlo
o
€oet
o
o
a- O .=t
o
o
a:O-t
FIBERGLASS
SUPPORT
l"
WALL ,f"
SLOT
VALLEY
PRTCASI,
W&r&
Wastewftr
o Systems
o Pmducils
InG. o SeMce
(zig) a95{764 msooRd317
P.O. Bo(95
Farc f/19) g#grzt B'ffivl$a' @81z1
Webrlb: www.vallelprcretom
Emall : fron6eelc@nlle1ryrcmtom
Double Walled PVG Riser & Lid Options
Poly Lid
(Static load tested to 5000lbs)r Skid resistance surfacer Available in green. Highest level of UV Probction induded. lncludes a bam gasket fur airtight and
watertight appl icationsr lncludes square drive scr€ws b disoounage
unauthorized enty. lnsulation panels achieve R-10 insulation raling
2' ol lnsulation
Standard
Orenco @ DuraFiber* Access Lids (FLD)
Not rsoommended br vehicular haffic
A" and 30'Diamebrs. Solid, resin-infused fiberglass oonstuction. 20,00G1b brcaking sbength. Standard green or broum oolorso Available with or without urefrrane lid gasket. Available with carbon filhation. 4 stainless steel flathead socket cap scrows & hex
key wrendr. lnsulated lids available - 2'or4"
Double Walled PVC Riser
. Available in 24' and 30" Diamebro Cut to lengfrro Sold in +l- 2" incremenb. Must be cut between ribs
VALLEY
PRtCASflrnc. oseMe
(719) 395€7G4 aISOo Rd'317
P.O. Bo(95
Farc (/19)ggf'37n BHEVISa' @81?.1
Webclb: vYww.valleyprcetorr
Ermll : fronUck@lralleyprccastom
Water &
Wastewater
o Systems
o Prcducils
Residential Biotube' Eflluent Filters
Applications
Our patented* 4-in. (100-mm) Biotube Effluent Filters, Biotube Jr., Biotube
Insert Filters, and Biotube Base Inlet Filters are ideal for residential septic
tanks and have a lifetime warranry. They prevent large solids from leaving
the tank, dramatically improving wastewater qualiry and extending the life
of residential drainfields.
4-in. (100-mm) Biotube Effluent Fiher
t
4-in. (1 00-mm) Biotube Jr.
(4-in. Biotube carridge auail-
able separateQ as Insert Fiber)
8-in. (200-mm)
Base Inlet Fiber
4-in. (100-mm)
Insert Fiher
I
o
J
I
I
Orencoi superior efrluentfibers resist cloging better than all other brands. Our stan-
dard, full-sized 4-in. (100-mm) Biotube Effluent Fiber prouides maximum long-term
protection in a complete package, with housing. Our 4-in. (100-mm) BiotubeJr., at
half the size of our standard model, has more f her"ing capacity than the full-sized f bers
sold by other manufacturers. For tanks with existing outlet tees, the Biotube Insert Fiber
is ideal. Andfor lou-profle tanks, therei the Base Inlet Fiber.
* Covered by patent numbers 5,492,635 and 4,439,323
To Order
Call your nearest Orenco Systems@, Inc. distributor. For nearest distribu-
tor, ca.ll Orenco at 800-348-9843 or go to www.orenco.com and click on
"Distributor Locator. "
APS-FT-1
Bev.3.4 O 1lil0
0renco Systems@, lnc.
Standard Features & Benefits
. Has 5-10 times
more flow area
than other brands,
so lasts many
times longer
between clean-
ings, increasing
homeowner
satlsfaction
. lnstalls in min-
utes inside new
or existing tanks;
extendible tee
handle for easy
removal
0ptional
Features &
Benef its
. Alarm available, to
signal the need for
c lea ning
. Flow modulating
discharge orifices
available to limit
flow rate leaving
tank, mitigat-
ing surges and
increasing
retention time
. Custom and
commercial sizes
available
Easyto clean by
simply hosing off
whenever the tank
needs pumping
Removes about
two-thirds of sus-
pended solids, on
average, extending
drainfield life
Corrosion-proof
construction, to
ensure long life
Lifetime warranty
o
o
o
a
Biotube
Filtering
Process
Effluent from the
relatively clear zone
of the septic tank,
between the scum
and sludge layers,
horizontally enters
the Biotube Effluent
Filter. Effluent then
enters the annular
space between the
housing and the
Biotubes, utilizing
the Biotubes'entire
surface for filtering.
Particles larger than
the Biotubes mesh
are prevented from
leaving the tank.
,
,
OrencoSystems"
lncorporated
Lltanging tfu Vh1, 1/1v
Wortd DoesVhstcttatr'
a\-/a
*.G
www.otenGo.com
Nomenclatures
4-in. Biotube Filter (standard)
FrIf 04!!-!IE
loo,,on*
Blank =
Filter diameter (inches)
W = fitsType 3034 outlet pipe
S = fits Schedule 40 outlet pjpe
no optionsM = flow modulation plate installedA = float bracket attached
Cartridge height:28" and 36" are standard
Housing height: 36" and 44" are standard
0ptions:A = float bracket
FS = 2" outlet orifice
FSO = 2" outlet orifice and overflow plate.
Base inlet model
Cartridge height: 14" standard
Housing height: 22" standard
Filter diameter (inches)
8-in. Biotube Filter (base intetmodel)
FT 08 22- 14 B
Blank = 1/8" filtrationP = 1/16" filtration
Biotube effluent lilter series
08 =8"
Blank = 1/S" filtrationP = 1/l6" filtration
. Also available with coupling and sleeve as a "kit": FI-oVERFLOWKIT
4-in. Biotub€ Jf. (includes cartridge and housing)
FT J TTO+ Tg--T*onr,
Blank =
Biotube effluent Iilter series
no options
= llow modulation plate installed
= float bracket attached
M
A
S
Cartridge height (inches)
Filter diameter (inches)
fits Type 3034 outlet tee
fits Schedule 40 outlet tee
4-in. Biotube Filter lnsert (cartridse onty)
FTi 0418-
Junior series
Biotube effluent lilter series
Blank = 1/S" filtralionP = 1/16" filtration
Blank = 1/8" filtrationP = 1/16" filtration
f
For customized options (e.9., NC
indicates N0rth Carolina regions)
W = fits Type 3034 outlet tee
S = fits Schedule 40 outlet tee
Cartridge height (inches)
Filter diameter (inches)
lnsert
Biotube effluent lilter series
Distributed By:
4-in. Biotube
Effluent Filter
Extendible PVC handle
Stainless steel set screws
Top seal plate
Air vents
Biotube@ filter cartridge
Solid base
Filter housing
4-in. Biotube Jn
Tank wall
Riser
wall
POLYLOK DISTRIBUTION BOX,
RISERS, AND LID
uD-BOX 0 & UDAOX I
D.BOX SEAL
(E1'BYDS(CffiWm.l
a3EA3)
16',SIDE CUT OUT
TOACCEPT
POLYLOK SEAL
NO.3001 TEAR OUT FOR
4'SDR-35 0R
scHD40
NOTTOSCAIE
UD.BOX 6'RISER
ROTO-FLOW4'
I
6u
i
UD.BOX 12'RISER NOTTOSCALE
POLYLOCK EOUATIZER
'v-NoTcH'wElR
1
${ PEts
8Ef ITVEIi{G
RIBS PR(n'IDE FRICTbN
FITFORAI.f PIFEID
#tl &
20'GOVER FOR RISER & DAOX ito7T0scArE
GASKETED SEAL ON
LID & RISER
\/
Waler &
Waebrraler
o Sygteme
r Ptoduds
(zr9) 395{264 moo Rd317
P.O. Bo(ms
Fu: f/lg) 3gf;37n B'HEvlda' @812,J.1
Webcb: www.valleyprcetom
Emall : fron6eok@valleyprccastomE PRtCASfrInc. oseMoe
ffi A m A HS s#
Ouick4 Plus
All-in-One Periscope
Ouick4 Plus Standard Chamber Ouick4 Plus
All-in-One 12 Endcap
Center Structural Columns
The Ouick4 Plus Standard Chamber offers maximum strength through its two center structural columns, This
chamber can be installed in a 36-inch-wide trench, Like the original line of Ouick4 chambers, it offers advanced
contouring capability with its Contour Swivel ConnectionrM which permits '1O-degree turns, right and left. lt is also
available in four-foot lengths to provide optimal installation flexibility. The Ouick4 Plus All-in-One 12 Endcap, and
the Ouick4 Periscope are available with this chamber, providing increased flexibility in system configurations,
Quick4 Plus Standard Chamber
o Two center structural columns offer increased stability and
superlor strength
o Advanced contouring connections
r Latching mechanism allows for quick installation
o Four-foot chamber lengths are easy to handle and install
. Supports wheel loads of 16,000 lbs/axle with 12" of cover
Quick4 Plus All-in-One 12 Endcap
. May be used at the end of chamber row for an inlet/
outlet or can be installed mid-trench
o Mid-trench connection feature allows construction of
chamber rows with center feed, as an alternative to
inletting at the ends of chamber rows
o Center-feed connection allows for easy installation of
serial distribution systems
. Pipe connection options rnclude sides, ends or top
Quick4 Plus All-in-One Periscope
o Allows for raised invert installations
. l BOo directional inletting
o Twelve inch raised inverl great for serial applications
Vuick4.fry !t:;
Ouick4 Plus Standard Chamber Side and End Views
48"
(EFFECTIVE LENGTH)
Quick4 Plus All-in-One 12 Encap Front, Side and End Views
't't.2"
13"
34"
12'
5.3'INVERT8'INVERT
i
Quick4 Plus All-in-One Periscope
8'INVERT
33'
OUICK4 PLUS
ALL-IN.ONE
(350"SwrvE[ )
m
[,]
OUICK4 PLUS
ALLIN.ONE 12
ENDCAP
6'
12.7'INVERT
5'
Ouick4 Plus Standard Chamber Specifications
Size(WxLxH)34" x 530 x 12" (86 cm x'135 cm x 31 cm)lnvert Height 0,6o, 5.3u, 8,Oo, 12.7',
(1.5 cm, 8.4 cm, 18.5 cm, 22,6 cn)Effective Length ...,48" (1 22 cm)
INFILTRATOR SYSTEMS, INC. STANDARD LIMITED WARRANTY
(a) The structural integrity of each chamber, end plate, wedge and other accessory manufactured by lnliltrator ( "Units"), when installed and
operated in a leachfield of an onsite septic system in accordance with lnfiltratols instructions, is warranted to the original purchaser ("Holder")
against defective materials and workmanship for one year from the date that the septic permit is issued for the septic system containing the Units;
provided, however, that if a septic permit is not required by applicable law, the warranty period will begin upon the date that installation of the
septic system commences. To exercise its warranty rights, Holder must notify lnfiltrator in writing at its Corporate Headquarters in Old Saybrook,
Connecticut within fifteen (15) days of the alleged defect. lnfiltrator will supply replacement Units for Units determined by lnfiltrator to be covered
by this Limited Warranty. lnfiltrator's liability specjfically excludes the cost of removal and/or installation ol the Units.
(b)THE LIMITED WARHANTY AND REMEDIES IN SUBPARAGRAPH (a) ARE EXCLUSIVE. THERE ARE NO OTHER WAFRANTIES WITH RESPECT
TO THE UNITS, INCLUDING NO IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOB A PAFTICULAR PURPOSE
(c) This Limited Warranty shall be void if any part of the chamber system is manufactured by anyone other than lnfiltrator. The Limited Watranty
does not extend to incidental, consequential, special or indjrect damages. lnfiltrator shall not be liable for penalties or liquidated damages,
including loss of production and profits, labor and materials, overhead costs, or other losses or expenses incurred by the Holder or any third party.
Specilically excluded {rom Limited Warranty coverage are damage to the Units due to ordinary wear and tear, alteration, accident, misuse, abuse
or neglect of the Unjtst the Units being subjected to vehicle traffic or other conditions which are not permitted by the installation instructions; failure
to maintain the minimum ground covers set forth in the installation instructions; the placement of improper materials into the system containing
the Unitsi failure of the Units or the septic system due to improper siting or improper sizing, excessive water usage, improper grease disposal,
or improper operation; or any other event not caused by lnfiltrator. This Limited Warranty shall be void if the Holder fails to comply with all of the
terms set forth in this Limited Watranty. Further, in no event shall lnfiltrator be responsible lor any loss or damage to the Holder, the Units, or any
third party resulting from installation or shipment, or from any product liability claims ot Holder or any third party. For this Limited Warranty to
apply, the Units must be installed in accordance with all site conditions required by state and local codes; all other applicable laws; and lntiltratofs
installation instructions.800.221 .4436
www. inf i ltratorsystems.com(d) No representative of lnfiltrator has the authority to change or extend this Limited Watranty. No warranty applies to any party other than the
original Holder.
The above represents the Standard Limited Watranty offered by lnfiltrator. A limited number of states and counties have different warranty
requirements. Any purchaser of Units should contact lnfiltrator's Corporate Headquarters in Old Saybrook, Connecticut, prior to such purchase,
to obtain a copy of the applicable warranty, and should carefully read that warranty prior to the purchase of Units.
W-
IN FILTRATOR'
systems inc.
6 Business Park Road r P.O. Box 768
Old Saybrook, CT 06475
860.577.7000 . FM 860,577.7001
. THE OUICK4@ PLUS STANDARD CHAMBER
Fsr technical assistance, installation instructions or customer serrice, call lnfiltrator Syetems at 800.221.4486
U.S. Patents: 4,759,661 i 5,O17 ,041 5,1 56,488; 5,336,01 7; 5,401 ,'1 1 6i 5,401,459; 5,51 1 ,903; 5,71 6,1 63; 5,588,778; 5,839,844
Canadian Patentsj 1,329,9591 2,004,564 Other patents pending.
is a registered trademark in Mexico. Contour Swivel Connection is a trademark of lnfiltrator Systems lnc. O 2009 lnfiltrator Systems lnc. Printed in U.S.A.PLUS051010tst-2