HomeMy WebLinkAboutConditions of PermitCONDITIONS OF PERMIT
BLRE-02 -24-8535
MATTHEW & ANGELA LUCK
Residential Addition
(lncludes 893 sq ft residential living plus 704 sq ft garage addition)
549 Hidden Valley Dr, GWS
Springridge Reserve PUD Ph 4, Lot 64
1 ) ALL WORK SHALL COMPLY WITH THE 2015 INTERNATIONAL RESIDENTIAL CODE (I.R.C.) AND 2018
I NTERNATIONAL ENERGY CONSERVATION CODE (I.E.C.C.)
2) PROPOSED IMPROVEMENTS ARE SUBJECT TO ALL APPLICABLE ITEMS CONTAINED IN THE
ATTACHED "GARFIELD COUNry BUILDING REOUIREMENTS". NUMBER REFERENCES NOTED ON
PLANS REFER TO SPECIFIC ITEMS ON THIS LIST.
3) ELECTRTCAL pERM|TTTNG AND TNSPECI|ONS BY COLORADO STATE ELECTRTC BOARD. ELECTRTCAL
ROUGH-IN APPROVAL IS REOUIRED AT FRAME INSPECTION. ELECTRICAL FINAL APPROVAL IS
REOUIRED FOR FINAL INSPECTION & CERTIFICATE OF OCCUPANCY.
4) WILDFIRE MITIGATION RECOMMENDATIONS: SHOULD COMPLY WITH WILDFIRE MITIGATION AND
DEFENSIBLE SPACE REOUIREMENTS OF THE COLORADO STATE FOREST SERVICE AND LOCAL FIRE
DISTRICT. SEE GARFIELD COUNry COMMUNITY DEVELOPMENT DEPARTMENT WEBSITE FOR
FURTHER INFORMATION.
5) OpEN HOLE SOTLS REPORT TNCLUDTNG COMPACTTON REPORT FOR STRUCTURAL FrLL lS REOUTRED
AT FIRST FOOTING INSPECTION, 1,500 PSF SOIL BEARING CAPACIry.
6) A LOT TMPROVEMENT CERT|F|CATE, SEALED BY A COLORADO LTCENSED SURVEYOR, lS REOUIRED AT
FOUNDATION INSPECTION TO VERIFY STRUCTURE _ INCLUDING PROPOSED ROOF OVERHANGS,
DECKS AND OTHER PROJECTIONS - IS IN COMPLIANCE WITH THE PLATTED BUILDING ENVELOPE
REOUIREMENTS.
7) ADD|T|ON OF 893 SO FT RESTDENTTAL LtVtNG TNCLUDES A "WET BAR',AND SHALL REMAIN lN
COMPLIANCE WITH GARFIELD COUNTY'S ADOPTED BUILDING RESOLUTION . WET BAR: AN AREA OF
A ROOM THAT IS DESIGNED TO BE USED FOR SERY/NG OF BEVERAGES, THAT MAY ONLY HAVE A
S/NGLE 8AR S/NKAND NO STANDARD SIZE KITCHEN APPLIANCES SUCH AS A STOVE, OVEN,
DISHWASHER OR FULL SIZE REFRIGERAIOR. COUNIER SHALL IS LIMITED TO 25 SAUARE FEET.
8) PERMIT APPLICANT PROPOSES ALTERNATE METHOD AND MATERIALS OF CONSTRUCTION IN LIEU
OF RESIDENTIAL FIRE-SPRINKLER SYSTEM FOR COMPLIANCE WITH SPRINGRIDGE RESERVE, Lot 64
RECORDED PLAT NOTE #6. PLEASE REFERENCE FIRE AREA SEPARATION STAMP BELOW AND
ARCHITECTURAL SHEET AO4 FIRE WALL DETAIL:
Fire Area Separation Wall:
ln lieu of the Fire Sprinkler System requirement, o "Fire Borrier" may be used to separate
or compartmentalize the building into smaller sized fire areas (2O75 l.B.C., Sectlan 707).
Specific requlrements include the followlng:
A. 2-Hour Flre-Rated Assenblv-Thefire barrier must comply with o 2-hour rated
assembly os approved by a recognized llsting agency, lncludlng (2) Iayers of 5/8"
Type X drywoll at both sides of wood-frame wolls (1.8.C., Table 7O7.3.70).
B, ConCinuitv - The fire barrier shall ertend from top of foundotion up to bottam of
roof sheothing. Except as noted below for penetrotions, the Z-hour fire-roting at
the fire barrier shall not be compromised over its entire length ond height.
C. Penetrqtions throueh Firc Barrier - Doors ond door ossemblies located in the
fire barrler, shall provide a 9o-minute fire rating wlth automatic ctosing device.
Mechanical ductwork penetroting the fire borrier shall be protected by fire-roted
dampers lnstalled in such monner os to ollow for regular inspections, servlce &
mointenance.