HomeMy WebLinkAboutBLDG Permit Drawing 03-01-24job no:
23-0424
dra
wn
by:
JP
che
cke
d by:
date
pr
inte
d:
-
INFORMATION
SHEET
A1.0
G
LENW
OO
D SPRING
S
91
9
Pal
mer Av
enu
e
Gl
enw
oo
d Sp
rin
gs,
CO
816
01
Pho
ne (9
70
) 37
9-9
23
9
Palomino
Design
Bui
ld
Deve
lopm
en
t
Bu
ild
ing Desi
gn
C
on
struction
jack
palo
mino
55@gmail.c
om
Copyright
Palomin
o Residentia
l
Design
date
:
re
ma
rks:
23-0424 A1.0
Kennedy Resid
en
ce
Addition a
nd Altera
tions
2074 CR 109
Glenwood Springs,
Colorado
81601
03
-01-2
4
Permit
Su
bmit
ABOV E FINI SH FLOOR
AC COU ST IC AL CEILING TI LE
ADJUST ABLE
ALTERNATE
ANCHOR BOLTS
AND
ARCHI TEC TURAL
AT
BEAM
BEAM POCKET
BEARING
BLOCKING
BOT TOM
BOT TOM OF F OOTI NG
BUILDING
BY O WNER
CA BINET
CEILING
CENTER LINE
CERAMIC TILE
CLEAR
CO LUMN
CO NC RET E
CO NNECT ION
CO NT INUO US
DETAIL
DOU BLE
DOWEL
EACH WA Y
ELEVAT ION
EXISTI NG
EXTERI OR
FLOO R
FO OTING
FO UNDATI ON
GAUGE
GLU-LAM
GYPSUM WALL BOARD
HEI GHT
HOOK
HORIZONTAL
INF ORMATIO N
INSU LA TION
JOIST
LINEAR FEET
LIVE LOAD
LONGI TUDI NAL
NOT IN C ONTRACT
ON C ENT ER
OPPOSITE
OVER
PAINTED
PERF ORATED
PLA TE
PLYW OOD
PROPERTY LI NE
REINFORC EMENT
REDW OOD
REQUI RED
RESI LIENT
REVISED
SHEET METAL
SIMILAR
SQUARE FEET
STANDARD
STEEL
STUDS
THIC K
TOI LET
TO P O F FOOTI NG
TO P OF PLATE
TOP O F LEDGE
TO P O F W ALL
TOT AL
TO WEL B AR
TRANSVERSE
TYPIC AL
UNLESS NOTED OTHERWISE
VERIF Y IN F IELD
VERTIC AL
VINYL W ALL C OVERING
WAT ER CLOSET
WAT ER HEATER
WAT ERPROOF
WAT ER RESIST ANT
WNDOW
WI TH
WOO D
TEAM
MEMBERS
:
A.F.F .
A.C.T.
ADJ.
ALT.
A.B.
&
ARCH.
@
BM.
BM. PKT.
BRG.
BLK'G.
BOT .
B.F.
BLDG.
B.O.
CAB .
CLG.
CL.
C.T.
CLR.
CO L.
CO NC .
CO NN.
CONT .
DTL.
DBL.
DWL.
E.W.
ELEV. OR EL.
EXI ST'G
EXT .
FLR.
FT G.
FND.
GA.
G.L.
G.W.B.
HT.
HK.
HORIZ.
INFO.
INSU L.
JST.
L.F.
L.L.
LONGI NT.
N.I.C.
O.C.
OPP.
O/
PTD.
PERF .
PL.
PLY.
PROP. LI NE
REI NF.
RDWD.
REQ 'D.
RESI L.
REV .
S.M.
SIM.
S.F. O R SQ. FT .
STD.
STL.
STDS.
THK.
TLT.
T.F.
T.P.
T.L.
T.W.
TOT .
T.B.
TRANSV.
TYP.
U.N.O.
V.I.F.
VERT.
V.W.C.
W.C.
W.H.
W.P.
W.R.
WI N.
W/
WD.
DETAI L
NUMBER
SHEET WHERE
LOCATED
DETAI L NUMBER
SHEET WHERE
LOCATED
DETAI L NUMBER
SHEET WHERE
LOCATED
DETAI L
NUMBER
DET AIL NUMBER
T. CONC.
100'-0
RI SE: RUN
NO RTH A RROW
INT ERIO R
ELEVAT ION
MARK
WI NDO W
SYMBOL
DOOR
SYMBOL
ELEVATI ON
MARK
DET AIL
REFERENC E
ROOF SLOPE
DET AIL
MARK
WALL
SECTI ON
BUILDING
SECTI ON
SY MBOL LIBRA RY:
NO RTH
AB BREV IA TIO NS:SH EET INDEX :MA T ER IA LS :
EARTH
U NDIST U RBED
FILL
SAN D
GRAV EL
MASONRY
BLO CK
BRI CK
STO NE
ASPHA LT
C ONC RETE
FINI SH
RO UGH
BLO CK ING
PLYWO OD
STEEL
BA TT
RIGI D
GYPSU M BO ARD
WOOD
METAL
INSULATION
MISC
OV ER FRA MING
FINISHES
PLAST ER
C ERA MIC T ILE
C ARPET
STO NE
SHEET W HERE
LOC ATED
SHEET WHERE
LOCATED
OWN
ER'
S REPRESENT
ATI
VE:
Palo
mino D
esign B
uild
919 Pa
lmer Avenue
Glenwoo
d Springs,
CO 81601
970 379-92
39
ja
ck
palomino
55@gma
il.
c
om
SCOPE OF WORK:
ADDI TI ON O F A N ATTA CHED G AR AG E AND A LTER A TIO NS TO AN EX I STI NG SI NGL E FAMI LY
R ES IDEN CE.
BUI LD ING D ATA:
CO NS TRU CT IO N T YP E:TYPE 5-B, UNPROT ECTED NON-SPRIN KE LE RE D
OC CU PAN CY C LAS S IFI CA TIO N:R-3:RESIDENTIAL
HEIG HT, A CTU AL /A LLO W ABLE :ACT UAL +/- 21'- 5/8 "; 25' AL LOW AB LE - SEE FACADE ELEVAT IONS
LO T AR EA:7.096 +/- ACRES, +/-309,101.76 SQ FT
ZO NNG :Rural Zone District
AS S ES SO RS PA RC EL NO :PARCEL NO 239512401010
LEG A L DES CR IP TIO N:Se ction: 12 T ownship: 7 Range: 8 9 Sub div is ion: Te ll e r Sp ri ngs
Lot : 10, 7.096 Acres
PR O PER TY ADDR ES S: 2074 CR 109
Glenwood Springs, CO 81601
SIDE YARD:
REAR YAR D:
SETBACKS:
FRONT YARD:50' MIN. ARTERIAL; 20' MIN. LOCAL
10' MIN.
25' MIN.
F IR E-R ES ISTIVE REQUIREM ENTS:NON E
APPLICABLE COD ES:2015 IRC
STRUCT DESIGN LIVE LOADS:SEE ST RUCT URAL DRAWIN GS
ENER GY COMPLIANCE:2018 IN TERNATI ONA L ENERGY CON SERV ATI ON CODE (IEC C), PRESCRI PTIV E MET HOD C OMPLIAN CE
OWNER:
Jac
k
Kennedy
2074 CR109
Glenwoo
d Spr
ings,
CO 81601
970 948-0346
jk
@r
of
.net
VICINIT Y MA P
Not to Sca le
SIT E DA TA :
No
rth
Permi t Sub mi t Set
A1.0 INFORMA TIO N SHEET
A2.0 b EXI STI NG ENTRY LEVEL F LOOR PLA N
A2.2 PROPOS ED ENT RY LEVEL FLOOR PLA N
A3.1 PROPOSED F AC ADE ELEV ATI ONS
A3.2 PRO PO SED FA CA DE ELEVA TIO NS
A4.1 BUILDI NG SECT IONS
A4.2 BUI LDI NG SECT IONS
A5.1 ENERGY NOT ES , WA LL SEC TI ON
E2.2 ENTRY LEV EL ELECT RIC AL PLAN
S-x ST RU CT URA L EN GI NEERI NG SHEET S
GENE
RAL CONTRACT
OR
:
Fraser F
r
eema
n
Luxur
y Homes LLC
xx B
asa
lt,
CO 81611
970 987-20
86
gffreema
n@hot
mail
.com
1,136 SF
EXISTING
COVER ED
GARAGE 1,334 SF 2,062 SF -
GRAN D TOTAL 1,334 SF 8,392 SF 1,136 SF 0 SF
728 SF
7,058 SF
DECKS/PATIOS:
SQUAR E FOOT AGE:SUB TOTAL
ENTRY LEVEL 0 SF 3,808 SF 704 SF
HE ATED LIVING ARE AS:
EXIST ING
UN COVERED
0 SF
EXISTING
3,808 SF
PROPOSED
LOWER LEVEL 0 SF 2,522 SF 432 SF 0 SF2,522 SF
SUB TOTAL 0 SF 6.330 SF 0 SF6.330 SF
PROPOSED
COVERED
-
0 SF
0 SF
0 SF
0 SF
PROPOSED
UN COVERED
0 SF
0 SF
0 SF
0 SF
--
PR OJE CT SI TE
2074 CR 109
Glenwo d Spr ings, CO 81601
S
t
a
t
e
H
i
g
h
w
a
y
8
2
To
Glenwood
Springs
C R 1 5 4
W est bank
Su bdiv ision R
o
a
ri
n
g
F
o
r
k
Ri
v
e
r
F
r
o
n
t
a
g
e
R
o
a
d
To Ca rbondal eTo Ca rbondal e
Iron Bridge
Su bdiv ision
C R 1 5 4
Th under Riv er
Ma rket
S p rin g V alle y R o a d
C R 1 0 9
C
R
1
0
9
1.ALL WORK SHALL COM PL Y W ITH G ARF IELD COU NTY'S ADOPTE D 20 18 IECC AND CLIMATE ZONE 5 REQU IREMENTS AND ALL APPL ICABLE ST AT E AND LOCAL
ADOP TED COD ES AND ORD INAN CES.
2.BUILD ING TH ERM AL EN VELOPE -
REF ER TO THE BUIL DIN G FL OOR P LANS IDE NT IF YING T HE BU ILD ING THE RMAL E NVELOP E AND ALL CONDITIONED AREAS W ITHIN THE ENVEL OPE AND AL L AREAS
OUTSID E OF TH E ENVE LOPE.
ENERGY C OMPLIANC E:
3.E NE RGY COMPLIANCE M ETH OD -
REF ER TO THE BUIL DIN G SECT ION S IDE NT IFYING T HE PRESC RI PTIVE ENERGY COM PL IANCE ME TH OD FOR THIS BUILDING INCL UD ING TH E SE L EC TED MATERIAL R-VALUE S;
U-VALUE S;AND FE NESTATION U -FACTORS COMPLYING W ITH TH E IRC TABLE R4 02.1.2 RE QUIREMENTS.
4.AIR SEALING-
REF ER TO THE BUIL DIN G SECT ION S IDE NT IFYING T HE AIR SEALING DETAILS AROU ND OPENINGS; P IP ES; PEN ETRATIONS; AN D JOINTS.
5.ME CH AN ICAL SYSTEMS -
REF ER TO THE FLOOR PLANS IDENT IFYING T HE MECH ANICAL SYSTE M DE SIGN DE TAIL S INCLUD ING THR PROP OSED EQUIPMENT ENERGY E FFIC IENCY RATE S; TYPES OF
E QU IPM EN T; F UE L TYPES; E QUIP ENT LOCATIONS; AND WH OLE HOUSE VE NTILATION SYSTEM COMP ONENTS.
6.E NE RGY EF FICIENT LIGH TING SPECIFICATION -
REF ER TO THE E LECTRICAL FLOOR PLANS IDENT IFYING T HE LOCATION AN D TYP E OF L IGH TING F IXTURE S COMPLYIMG W ITH THE 90 % HIG H -EF FIC ACY (L ED COMP LYING)
REQU IRT EMENTS.
7.MANUAL J REP ORT -
TH IS BU ILDING ; EQU IPM EN T; AND BUIL DIN G SYSTEM S IN CORPORATE D INTO TH IS BU ILD ING CONSTRU CTION W ILL BE DESIGNE D AND INSTALLE D PER TH E REQU IREMENTS
IDENTIFIED IN T HE M ANUAL J RE PORT PREPARED SPEC FICAL LY FOR THIS BUILDING, AN D SUBM ITTED AS A PART OF THESE BUILD ING C ONSTRUCT ION DOCU ME NTS AND
SP ECIF ICATIONS UN DER SEPARATE COVER.
1 .ALL W ORK SHALL C OMPLY W ITH APPLI CA BLE STA TE, LOC AL A ND TO WN ADOPT ED CO DES AND O RDINA NCES.
2 .THE C ONT RAC TOR SHALL BE RESPON SIBLE F OR:
THE S AFET Y AND CARE OF ADJAC ENT PRO PERT IES DURNG C ONST RUC TI ON; C OMPLIAN CE W ITH ALL O.S.H.A . HEALTH A ND SF ET Y
REGULAT IO NS; PROT EC TI ON OF ALL W ORK IN PLA CE U NTI L THE PRO JEC T IS O CC UPI ED BY THE OW NER; SECURI NG ALL BUILDNG
PERMITS AND B UI LDING I NSPEC TI ON APPROVALS; CO ORDIN ATI NG THE W ORK OF A LL TRADES REQ UI RED TO CO MPLETE THE PROJECT ;
AND SECURING T HE OW NER'S APPROV AL FO R USE OF A L BUIDI NG PROUDCT S, C OMPONENTS, APPLI ANC ES, AND BUILDING EQ UI PMENT .
GENERA L NOT ES:
ST
RUCT
URAL E
N
GIN
EER:
Na
te D
eck
er,
PE, S
E
DB St
ruc
tur
al D
es
ig
n Limited
1229 Sa
ge Court
Rifle, CO 81650
801 529-
648
1
na
te@d
bsd.
co
m
NEW
GARAGE
CONC. SLAB
NEW ELEC
SUB-PANEL
EXISTING
ENTRY
-
EXISTING
GARAGE
CONC. SLAB
EXISTING
ENTRY
PORCH
-
NEW 1:12 SLOPE
RAMP, VERIFY
EXACT LENGTH IN
THE FIELDEXISTING
CONCRETE
WALK
LEVEL
LANDING
T. SLAB
100'-0
EXISTING
MUDROOM
-
EXISTING
ELEC MAIN
DISCONNECT
PANEL
FIN. FLR.
+/-105'-8 3/4
FIN. FLR.
+/-105'-8 3/4
HOSE
BIBB
T. EXIST.
LANDING
+/-105'-8 3/4
24" DIA.
CMPRSR.
VIF
+/-21'-2"
+
/
-
1
8
-
'
6
"
+/-1 7 6 '-0 " V I F
+
/
-
5
4
'
-
3
"
V
I
F
47'-9"
23'-9"
SHADED AREA -
NOTE:
SHADED AREA INDICATES NEW
ONE-STORY GARAGE ADTIONEXISTING
DETACHED
TWO-STORY
GARAGE/
APARTMENT
EXISTING
RESIDENCE
EXISTING
SEPTIC TANK
TO REMAIN
EXISTING
LEACH FIELD
TO REMAIN
+
/
-
3
0
'
-
8
"
EXISTING
ASPHALT
MOTORCOURT
EXISTING GRAVEL
DRIVEWAY TO
REMAIN, TYP.
LOT 10
+/-7.69 ACRES
PROPERTY LINE,
TYP.
23-0424 A1.1
date: remarks:
job no: 23-0424
drawn by: xx
checked by: xx
date printed:xx
20 50 100 FT0
GLENWOOD SPRINGS
919 Palmer Avenue
Glenwood Springs, CO 81601
Phone (970) 379-9239
Palomino Residential Design
jackpalomino55@gmail.com
Copyrigh
t Palomino Residential Design
03-01-24
Development
Building Design
Construction
Permit Submit
SITE P
LAN
A1.1SITE DIAGRAM
1"= 40'-0"NORTH
SITE NOTES:
UTILITIES
ALL BUILDING UTILITY LINE CONNECTIONS, LOCATIONS
AND ROUTING SHALL BE VERIFIED IN THE FIELD AND
SHALL BE LOCATED UNDERGROUND.
1.
AIR CONDITIONING OR COOLING UNITS:
IF PROVIDED, ALL AIR CONDITIONING EQUIPMENT SHALL
BE LOCATED AND SCREENED FROM PUBLIC VIEW AS
REQUIRED BY THE HOA RQUIREMENTS. VERIFY THE
LOCATON OF ALL EQUIPMENT IN THE FIELD PRIOR TO
INSTALLATION.
2.
Kennedy Residence
Addition and Alterations
2074 CR 109
Glenwood Springs, Colorado 81601
EXISTING ENTRY LEVEL PLAN
@ 1/4"= 1'-0"
EXISTING
ENTRY LEVEL PLAN
A2.0b
NORTH
+/-40'-11 1/2"
EXISTING
DRIVEWAY
-
+/-12'-0"+/-28'-6"
EXISTING
ENTRY
-
EXISTING
GARAGE
CONC. SLAB
EXISTING
COVERED PORCH
EXIST.
CONC. SLAB
EXISTING ASPHALT
PAVING
EXISTING
LANDSCAPE
RETAINING WALL
UP
4R
R=+/-6.85"T=11"
EXISTING
PORTE-COCHERE
-
UP
2R
EXISTING
ENTRY
PORCH
-
NEW 1:12 SLOPE
RAMP, VERIFY
EXACT LENGTH IN
THE FIELD
EXISTING
CONCRETE
WALK
+/-4'-5 1/4"
+/-12'-0"
EXISTING +36" GUARDRAIL @ PORCH TYP.
OPEN TO
LIGHTWELL
BELOW
R=7 1/2"
T=11"
LEVEL
LANDING3'-0"CLEAR
+/-15'-0" VIF +/-4'-0"
T. SLAB
100'-0
T. EXIST.
MID-LND'G.
+/-102'-4
T. EXIST
LANDING
+/-105'-8 3/4
EXISTING
MUDROOM
-
+/-4'-11"
EXIST. 4" DIA.
RADON RISER
+/-3'-10 1/4"
NEW GRASP RAIL
@ EA . COLUMN
EXISTING
ELEC MAIN
DISCONNEC T
PANEL
EXISTING ELEC
CONDUIT TO
EXISTING
DISCONNECT
PANEL
UP
6R
FIN. FLR.
+/-105'-8 3/4
+/-4'-0"
+/-9'-2"
LANDINGRAMP
FIN. FLR.
+/-105'-8 3/4
EXIST
DOOR
EXIST
DOOR
EXIST
OVERHEAD
GARAGE DOOR
EXIST
OVERHEAD
GARAGE DOOR
EXIST. 4x4 POST
EXIST. 4x4 POST
EXIST. 4x4 POST
EXIST. 4x4 POST
STEP
DN.
T. EXIST. SLAB
+/-105'-6 1/2
VERIFY
T. EXIST. SLAB
+/-104'-3 1/2
VERIFY
T. EXIST. SLAB
+/-104'-3 1/2
VERIFY
APPROXIMATE LOCATION OF
EXISTING ATTIC ACCESS
ABOVE
EXIST STUDPACK
POST FOR BEAM
BEARING
EXIST
1/2 STOP
PASS-THRU
ELEVATOR
+/-7'-2 5/8"
+/-4'-0 7/16"
+/-3'-7 3/4"
+/-3'-4 15/16"
LINE OF EXIST
DOOR TRACK
ABV., TYP.
CLR., VIF
1 1/2" VIF
FLOOR
PROJECTION
+/-4'-6"
+/-6'-7"
+/-1 3/4"
VIF
2 5/8"
T. EXIST.
LANDING
+/-105'-3
NOTE:
6'-0" VIF
FACE OF EXIST STUD
WALL @ STAIR
OUTSIDE FACE OF EXIST
STUD WALL ABOVE
+/-20'-10" VIF
LINE OF
EXIST BEAM &
STUD WALL
ABOVE, SEE
STRUCT DWGS
FACE OF EXIST DOOR
TRACK ABOVE
EXIST
WINDOW
+/-4'-7"
OUTSIDE
FACE OF NEW
STUD WALL, ABV.
EXIST RESIDENCE TO REMAIN
EXIST
WNDW
EQ.EQ.
+/-26'-11"
+/-5'-0"
31'-11"
24-0424 A2.0b
date: remarks:
job no: 24-0424
drawn by: xx
checked by: xx
date printed:xx
2 4 80
GLENW
OOD SPRINGS
815 Blake Avenue
Glenwood Springs, CO 81601
Phone (970) 947-9014
Fax (970) 947-9137
Palomino Design-Build PC
www.palominodesignbuild.com
Copyright Palomino Design-Build PC
Architecture
Development
Construction
Kennedy Residence
Addition and Alterations
2074 CR 109
Glenwood Springs, Colorado 81601
03-01-24
Permit Submit
A
A4.1
C
A4.2
A
A4.1
B
A4.1
B
A4.1
C
A4.2
GAS-FIREDBOILER24"x24"VIF
GAS-FIREDFAU24"x24"VIF
PROPOSED ENTRY LEVEL PLAN
@ 1/4"= 1'-0"
PROPOSED
ENTRY LEVEL PLAN
A2.2
NORTH
23'-9"
22'-10"
+/-26'-11"
+/-8'-1"
14'-2"
23'-9"
4'-9 1/2"4'-9 1/2"
NEW
GARAGE
CONC. SLAB
15'-8"6'-6"
2'-0"
2'-0"
POLARIS RANGER
58 W x 110 L x 73 H,
VERIFY
4'-0"
27'-9"
2'-8"
3'-4"
7'-9"
3'-8"
EARTHROAMER
119 W x 360 L x 156 H
47'-9"
16'-4"
30
DEGREES,
TYP.
NEW ELEC
SUB-PANEL
6'-4 1/2"
5'-0"
31'-11"
5 1/2"
2 1/2"
12"
NEW
TLT. RM.
CONC. SLAB
+/-40'-11 1/2"
EXISTING
DRIVEWAY
-
+/-12'-0"+/-28'-6"
EXISTING
ENTRY
-
EXISTING
GARAGE
CONC. SLAB
NEW
ENCLOSED
STORAGE ROOM
EXIST.
CONC. SLAB
EXISTING ASPHALT
PAVING
EXISTING
LANDSCAPE
RETAINING WALL
EXISTING
PORTE-COCHERE
-
UP
2R
EXISTING
ENTRY
PORCH
-
NEW 1:12 SLOPE
RAMP, VERIFY
EXACT LENGTH IN
THE FIELD
EXISTING
CONCRETE
WALK
+/-4'-5 1/4"
+/-12'-0"
EXISTING +36" GUARDRAIL @ PORCH TYP.
OPEN TO
LIGHTWELL
BELOW
R=7 1/2"
T=11"
LEVEL
LANDING3'-0"CLEAR
+/-15'-0" VIF +/-4'-0"
T. SLAB
100'-0
EXISTING
MUDROOM
-
NEW GRASP RAIL
@ EA. COLUMN
EXISTING
ELEC MAIN
DISCONNECT
PANEL
EXISTING ELEC
CONDUIT TO
EXISTING
DISCONNECT
PANEL
FIN. FLR.
+/-105'-8 3/4
+/-4'-0"
+/-9'-2"
LANDINGRAMP
FIN. FLR.
+/-105'-8 3/4
EXIST
DOOR
EXIST
OVERHEAD
GARAGE DOOR
EXIST
OVERHEAD
GARAGE DOOR
NEW
OVERHEAD
GARAGE DOOR
168"X 168" (14'x14')
NOTE:
RELOCATE EXISTING WINDOW
TO WEST FACADE OF NEW
GARAGE ADDITION, SEE NEW
FACADE ELEVATIONS.
SLOPE
DOWN
SLOPE
DOWN
SLOPE
DOWN
SLOPE SLAB
DOWN TO DRAIN
1/8"MIN./FT., TYP.,
U.N.O.
EXIST.
4x4 POST
EXIST. 4x4 POST
EXIST. 4x4 POST
EXIST. 4x4 POST
4'-0" SQ.
CONC. LANDING
HOSE
BIBB
NOTE:
RELOCATED
EXISTING WINDOW ,
VERIFY EXACT
ROUGH OPENING
DIMENSIONS IN THE
FIELD PRIOR TO
FRAMING THE
OPENING, SEE NEW
FACADE
ELEVATIONS.
NOTE:
PROVIDE FROST-FREE HOT/COLD HOSE BIBB,
VERIFY EXACT LOCATION IN THE FIELD
NOTE:
PROVIDE 4" DIAMETER MIN. FLOOR DRAIN, IN NEW
GARAGE SLAB, ROUTE UNDERGROUND IN RIGID PVC PIPE
AND TERMINATE TO DAYLIGHT OR TO DRYWELL AS
REQUIRED BY THE OWNER AND AS REQUIRED BY THE
BUILDING INSPECTION REQUIREMENTS
NEW 36"x80"
SOLID CORE
EXTERIOR DOOR
NOTE:
ALIGN CENTER OF
NEW EXTERIOR DOOR
TO EXISTING DOOR
DASHED LINE INDICATES LINE OF NEW/EXISTING
OVERHANG ABOVE, TYP.
RAKE AND EAVE OVERHANG DIMENSION, TYP., U.N.O.
STEP
DN.
T. EXIST. SLAB
+/-105'-6 1/2
VERIFY
T. EXIST. SLAB
+/-104'-3 1/2
VERIFY
T. EXIST. SLAB
+/-104'-3 1/2
VERIFY
APPROXIMATE LOCATION OF
EXISTING ATTIC ACCESS
ABOVE
APPROXIMATE
LOCATION OF NEW
22"x30" ATTIC
ACCESS ABOVE
UP
10R
T. EXIST.
LANDING
+/-105'-8 3/4
EXIST. 4" DIA.
RADON RISER
EXIST
DOOR
EXIST 1/2 STOP
PASS-THRU
ELEVATOR
EXIST
WINDOW
ABOVE
45 DEGREE
WINDER TREAD
EXISTWINDOWABOVE
NEW
36"x80"
DOOR
NEW
PAIR
42"x96"
DOORS
T. NEW SLAB
PERIMETER
+/-100'-0
MATCH EXIST.
SLAB, TYP.
T. DRAIN
+/-99'-9
VERIFY
NEW
WINDOW
ABV.
NEW
WINDOW
ABV.
NEW
WINDOW
ABV.
NEW
WINDOW
ABOVE
NEW
WINDOW
ABOVE
NEW
WINDOW
ABOVE
LINE OF OPTIONAL
LOFT ABOVE
24" DIA.CMPRSR.VIF
NEW
36"x80"
SALOON DOOR
NOTE:
NEW RAMP IS
OPTIONAL, VERIFY
CONSTRUCTION IN
THE FIELD WITH
THE OWNER
BUILDING FLOOR ELEVATION
BUILDING ELEVATION 100'-0" = SITE ELEVATION 6086.58' VIF
36"x60"
DBL HUNGN1C
FACADE ORIENTATION'N' - NORTH'E' - EAST'S' - SOUTH'W' - WEST
FLOOR LEVEL'1' - BASEMENT'2' - ENTRY LEVEL'3' - UPPER LEVEL
WINDOW DESCRIPTIONSEE FACADE ELEVATIONFOR HANDING
WINDOW SYMBOL
72"x96"
SL GL DR
TEMP GL
10N
FACADE ORIENTATION'N' - NORTH'E' - EAST'S' - SOUTH'W' - WEST
DOOR NUMBER'10-19' - BASEMENT'20-29' - ENTRY LEVEL'30-39' - UPPER LEVEL
DOOR DESCRIPTIONSEE FACADE ELEVATIONFOR HANDING
EXTERIORDOOR SYMBOL
WINDOW IDENTITY TAGA,B,C, ETC.
DOOR/WINDOW SYMBOL LEGEND 1
NOTE:FENESTRATION U-FACTOR,SEE BUILDING SECTIONS FOR MINIMUM U-FACTOR,TYP.
SMOKE ALARM NOTES
SMOKE ALARMS ARE REQUIRED TO BE LOCATED AT EACH STORY INCLUDING
THE BASEMENT LEVEL (R314.3).
5.
SMOKE ALARMS ARE REQUIRED TO BE LOCATED IN EACH SLEEPING ROOM
(R314.3).
4.
SMOKE ALARMS ARE REQUIRED TO BE WIRED TO THE PRIMARY POWER
SOURCE AND HAVE BATTERY BACKUP. (R314.6)
3.
SMOKE ALARMS ARE REQUIRED TO BE INTERCONNECTED SUCH THAT
ACTUATION OF ONE WILL ACTUATE ALL SMOKE ALARMS. (R314.4)
2.
SMOKE ALARM LOCATIONS -
A SMOKE ALARM IS REQUIRED OUTSIDE OF EACH SEPARATE SLEEPING AREA.
(R314.3) AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED
OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF
THE BEDROOMS WHEN FUEL-FIRED APPLIANCES ARE INSTALLED AND WHEN
THE DWELLING HAS AN ATTACHED GARAGE. (R315.3)
1.
4 OR MORE RISERS - STAIRS WITH 4 OR MORE RISERS ARE REQUIRED TO
HAVE CONTINUOUS HANDRAILS (R311.7.8).
4.
SPACE UNDER STAIRS - ENCLOSED USEABLE SPACE UNDER STAIRS SHALL
BE PROVIDED WITH 1/2" GYP. BD. ON UNDERNEATH SIDE OF WALL AND
SOFFITS (R302.7). FIRE STOP STAIRS AT STRINGERS (R302.11)
5.
STAIRWAY MINIMUM HEADROOM REQUIREMENT IS 6'-8" CLEAR (R311.7.2).6.
GUARDRAILS FOR BALCONIES, ELEVATED DECKS AND STAIR LANDINGS
THAT ARE MORE THAN 30" ABOVE GRADE OR FLOOR BELOW SHALL BE A
MINIMUM OF 36" HEIGHT. CLEARANCE BETWEEN INTERMEDIATE PICKETS
MUST BE SUCH THAT A 4" DIAMETER SPHERE CANNOT PASS THROUGH
(R312).
7.
1.) PROVIDE "JELD-WEN", OR APPROVED EQUAL ALUMINUM-CLAD WOOD
WINDOWS WITH U=0.30 OR LESS.
2.) CONFIRM ALL WINDOW SIZES PER OWNERSHIP SELECTIONS UNLESS
NOTED OTHERWISE.
3.) THE WINDOW IMAGERY REPRESENTS SIZE AND TYPE ONLY. THE
DIVIDED LITE(S) ARE TBD BY OWNER.
4.) SEE THE ELEVATIONS FOR OPERATION.
5.) FIELD VERIFY ALL ROUGH OPENINGS.
6.) SLIDER DOORS SPECIFIC PER CLIENT SELECTION.
7.) CONCUR PER MANUFACTURER INSTALLATIONS AND SPECIFICATIONS
FOR DOOR AND WINDOW PLACEMENTS.
8.) GLAZING IN HAZARDOUS LOCATIONS IS REQUIRED TO BE GLAZED
WITH SAFETY MATERIAL. (R308.3 AND R308.4).
9.) WINDOWS LOCATED MORE THAN 72" ABOVE THE GRADE BELOW AND
LESS THAN 24" ABOVE THE FLOOR MUST BE PROVIDED WITH FALL
PREVENTION DEVICES THAT COMPLY WITH ASTM F 2090 OR HAVE A
MAXIMUM OPNEING OF 4 INCHES. (R312.2.1)
WHERE WINDOW OPERATING CONTROL DEVCIES (WOCD'S) ARE
UTILIZED, SUCH DEVICES SHALL MEET ASTM F2090-10 STANDARD
SPECIFICATION
FOR WINDOW FALL PREVENTION DEVICES WITH EMERGENCY ESCAPE
(EGRESS) RELEASE MECHANISMS.
10.) EGRESS DOORS - ALL EGRESS DOORS SHALL BE READILY
OPENABLE FROM THE SIDE FROM WHICH EGRESS IS TO BE MADE
WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE OR EFFORT
(R311.1).
DOOR AND WINDOW GENERAL NOTES
FURNITURE SHOWN ARE NOT INCLUDED IN THE CONTRACT (NIC)
AND WHERE INDICATED ARE FOR COORDINATION OF ELECTRICAL
REQUIREMENTS ONLY.
FURNITURE, INTERIOR ACCESSORIES & BUILT-INS
1.
AT CLOSETS WHERE A SHELF AND POLE (SH & P) ARE INDICATED,
THE INSTALLATION SHALL BE LIMITED TO ONE (1) SHELF AND ONE
(1) POLE MOUNTED AT +66" ABOVE THE FINISHED FLOOR, TYP.,
U.N.O.
2.
BUILT-INS WHERE SHOWN ARE NOT INCLUDED IN THE CONTRACT
(NIC) AND WHERE INDICATED ARE FOR COORDINATION OF
ELECTRICAL REQUIREMENTS ONLY.
3.
CONTINUOUS HANDRAIL - A CONTINUOUS HANDRAIL WITH RETURNS @ +34"
TO 38" ABOVE THE FINISHED STAIR NOSINGS IS REQUIRED ALONG THE
STAIRWAY PER 311.7.8 HANDRAIL GRIP CROSS-SECTIONAL DMENSIONS TO
BE 1 1/4" TO 2".
OPENINGS IN STAIRWAY HANDRAIL & GUARDRAIL - THE MAXIMUM SIZE OF
OPENING IN THE HANDRAIL/GUARDRAIL ON THE OPEN SIDE OF A STAIRWAY
IS 4 3/8 INCHES, 4" ELSEWHERE PER 312.1.3
MINIMUM STAIR DIMENSIONS - MAXIMUM RISER 7 3/4"; MINIMUM TREAD 10";
MINIMUM STAIR WIDTH 36" (R311.7.5.1 & R311.7.5.2). SEE PLAN FOR SPECIFIC
DIMENSIONS.
STAIRWAY NOTES
1.
2.
3.
1
.
BUILDING THERMAL ENVELOPE
THE PERIMETER OF THE BUILDING THERMAL ENVELOPE IS DEFINED BY
THE PERIMETER EXTERIOR WALL TYP., U.N.O.
2
.
THE BUILDING PERIMETER WALLS, INCLUDING PERIMETER
CRAWLSPACE WALLS; PERIMETER WALLS AGINST UNEXCAVATED
AREAS (RETAINING WALLS); CATHEDRAL CEILINGS; ATTIC CEILINGS;
AND CONDITIONED FLOORS OVER NON-CONDITIONED SPACE WILL BE
INSULATED TO THE INSULATION STANDARDS IDENTIFIED ON THE
BUILDING SECTIONS, TYP., U.N.O.
3.THE BUILDING PERIMETER WALLS, ARE FRAMED OF 2x6 STUDS @ 16"
O.C., TYP., U.N.O.3'-9"
3 1/2"
PROPOSED STORAGE LOFT PLAN
@ 1/4"= 1'-0"NORTH
NEW PAIR
72"x80"
DOORS
10S
10W
10N
10E
E2AE2BE2C
N1B
N1C
N2A
N2B
N2C
N2DN1A
E1A
24-0424 A2.2
date: remarks:
job no: 24-0424
drawn by: xx
checked by: xx
date printed:xx
2 4 80
GLENW
OOD SPRINGS
815 Blake Avenue
Glenwood Springs, CO 81601
Phone (970) 947-9014
Fax (970) 947-9137
Palomino Design-Build PC
www.palominodesignbuild.com
Copyright Palomino Design-Build PC
Architecture
Development
Construction
Kennedy Residence
Addition and Alterations
2074 CR 109
Glenwood Springs, Colorado 81601
03-01-24
Permit Submit
B D
A
A4.1
D
C
A4.2
A
A4.1
B
A4.1
B
A4.1
C
A4.2
A
BA
2
7
3
5
1
C
C
4
6
PROPOSED
FACADE ELEVATIONS
A3.1
Exterior Material Notes
1. Roofing -
Existing fiberglass shingle roofing to remain, typ.
New fiberglass shingle roofing to match existing roofing style and color.
2. Fiber Cement Siding -
New fibre cement board-n-batten siding and shingle siding shall match the existing siding profiles, dimesions and textures. Existing and new board-n-batten siding and shingle siding to be re-painted
in color to match the existing color and as selected by the Owner and as identified on the material samples board, typ.
3. Fiber Cement Corner Boards and Door and Widow Trim -
Existing and new wood trim to be re-painted in color to match the existing color and as selected by the Owner and as identified on the material samples board, typ. All trim profiles, face dimensions
and textues will match existing.
8"
16'-4 1/2"
17'-0 1/2"
1'-4"
TRUSS
HEEL HEIGHT
FIN. FLR. @
EXISTING
MUDROOM
105'-8 3/4
T. SLAB @
EXIST. GARAGE
100'-0
T. PL. @
EXIST. GARAGE
+/-109'-1 1/8
T. BM. @
ENCLOSED STORAGE
+/-108'-1 1/8
T. PL. @
EXISTING
MUDROOM
114'-9 7/8
+/-9'-1 1/8"
T. PL. @
NEW GARAGE
117'-0 1/2
5:12 = 22.62
8'-0"
A
A4.1
B
A4.1
PROPOSED WEST ELEVATION
@ 1/4"= 1'-0"
EXISTING
DOOR
EXISTING
DOOR
EXISTING
DOOR
EXISTING
WINDOW
+/-21'-2 5/8" ACTUAL
EXIST. AVERAGE
GRADE
+/-99'-6
E Q .
E Q .
23'-9"
MID-POINT
OF ROOF
ACTUAL < 25'-0" MAX. ALLOWABLE
MID-POINT OF ROOF
+/-120'-8 5/8
36"x60"
DBL HUNGN1C
FACADE ORIENTATION'N' - NORTH'E' - EAST'S' - SOUTH'W' - WEST
FLOOR LEVEL'1' - BASEMENT'2' - ENTRY LEVEL'3' - UPPER LEVEL
WINDOW DESCRIPTIONSEE FACADE ELEVATIONFOR HANDING
WINDOW SYMBOL
72"x96"
SL GL DR
TEMP GL
10N
FACADE ORIENTATION'N' - NORTH'E' - EAST'S' - SOUTH'W' - WEST
DOOR NUMBER'10-19' - BASEMENT'20-29' - ENTRY LEVEL'30-39' - UPPER LEVEL
DOOR DESCRIPTIONSEE FACADE ELEVATIONFOR HANDING
EXTERIORDOOR SYMBOL
WINDOW IDENTITY TAGA,B,C, ETC.
DOOR/WINDOW SYMBOL LEGEND 1
NOTE:FENESTRATION U-FACTOR,SEE BUILDING SECTIONS FOR MINIMUM U-FACTOR,TYP.
PROPOSED NORTH ELEVATION
@ 1/4"= 1'-0"
C
A4.2
EXISTING
WINDOW
8"
16'-4 1/2"
17'-0 1/2"
1'-4"
TRUSS
HEEL HEIGHT
FIN. FLR. @
EXISTING
MUDROOM
105'-8 3/4
T. SLAB @
EXIST. GARAGE
100'-0
T. PL. @
EXIST. GARAGE
+/-109'-1 1/8
T. BM. @
ENCLOSED STORAGE
+/-108'-1 1/8
T. PL. @
EXISTING
MUDROOM
114'-9 7/8
+/-9'-1 1/8"
T. PL. @
NEW GARAGE
117'-0 1/2
8'-0"
9'-1 1/8"
+/-16'-0 1/4"
date: remarks:
job no: 23-0424
drawn by: xx
checked by: xx
date printed:xx
GLENWOOD SPRINGS
919 Palmer Avenue
Glenwood Springs, CO 81601
Phone (970) 379-9239
Palomino Residential Design
jackpalomino55@gmail.com
Copyrigh
t Palomino Residential Design
Development
Building Design
Construction
23-0424 A3.1
03-01-24
Permit Submit
Kennedy Residence
Addition and Alterations
2074 CR 109
Glenwood Springs, Colora
do 81601
BUILDING
SECTIONS
A3.2
PROPOSED EAST ELEVATION
@ 1/4"= 1'-0"
A
A4.1
B
A4.1
EXISTING
WINDOW
NEW
DOOR
FIN. FLR. @
EXISTING
MUDROOM
105'-8 3/4
T. SLAB @
EXIST. GARAGE
100'-0
T. PL. @
EXIST. GARAGE
+/-109'-1 1/8
T. BM. @
ENCLOSED STORAGE
+/-108'-1 1/8
T. PL. @
EXISTING
MUDROOM
114'-9 7/8
+/-9'-1 1/8"
T. NEW PL. @
EXISTING
MUDROOM
+/-117'-3 7/8
VIF
+/-2'-6"
VIF
+/-9'-1 1/8"
5:12 = 22.62
23'-9"
FIN. FLR. @
EXISTING
MUDROOM
105'-8 3/4
T. SLAB @
EXIST. GARAGE
100'-0
T. PL. @
EXIST. GARAGE
+/-109'-1 1/8
T. BM. @
ENCLOSED STORAGE
+/-108'-1 1/8
T. PL. @
EXISTING
MUDROOM
114'-9 7/8
T. PL. @
NEW GARAGE
117'-0 1/2
8"
16'-4 1/2"
17'-0 1/2"
1'-4"
TRUSS
HEEL HEIGHT
8'-0"
EXISTING
WINDOW
6'-8"
+/-16'-0 1/4"
36"x60"
DBL HUNGN1C
FACADE ORIENTATION'N' - NORTH'E' - EAST'S' - SOUTH'W' - WEST
FLOOR LEVEL'1' - BASEMENT'2' - ENTRY LEVEL'3' - UPPER LEVEL
WINDOW DESCRIPTIONSEE FACADE ELEVATIONFOR HANDING
WINDOW SYMBOL
72"x96"
SL GL DR
TEMP GL
10N
FACADE ORIENTATION'N' - NORTH'E' - EAST'S' - SOUTH'W' - WEST
DOOR NUMBER'10-19' - BASEMENT'20-29' - ENTRY LEVEL'30-39' - UPPER LEVEL
DOOR DESCRIPTIONSEE FACADE ELEVATIONFOR HANDING
EXTERIORDOOR SYMBOL
WINDOW IDENTITY TAGA,B,C, ETC.
DOOR/WINDOW SYMBOL LEGEND 1
NOTE:FENESTRATION U-FACTOR,SEE BUILDING SECTIONS FOR MINIMUM U-FACTOR,TYP.
PROPOSED SOUTH ELEVATION
@ 1/4"= 1'-0"
C
A4.2
EXISTING
WINDOW
8"
16'-4 1/2"
17'-0 1/2"
1'-4"
TRUSS
HEEL HEIGHT
FIN. FLR. @
EXISTING
MUDROOM
105'-8 3/4
T. SLAB @
EXIST. GARAGE
100'-0
T. PL. @
EXIST. GARAGE
+/-109'-1 1/8
T. BM. @
ENCLOSED STORAGE
+/-108'-1 1/8
T. PL. @
EXISTING
MUDROOM
114'-9 7/8
+/-9'-1 1/8"
T. PL. @
NEW GARAGE
117'-0 1/2
date: remarks:
job no: 23-0424
drawn by: xx
checked by: xx
date printed:xx
GLENWOOD SPRINGS
919 Palmer Avenue
Glenwood Springs, CO 81601
Phone (970) 379-9239
Palomino Residential Design
jackpalomino55@gmail.com
Copyrigh
t Palomino Residential Design
Development
Building Design
Construction
23-0424 A3.1
03-01-24
Permit Submit
Kennedy Residence
Addition and Alterations
2074 CR 109
Glenwood Springs, Colora
do 81601
A4.1
BUILDING
SEC
TIONS
EXISTING GARAGE
SECTION
@ 1/4"= 1'-0"A
NEW
ENCLOSED
STORAGE
ROOM
C
A4.2
5:12 = 22.62
existing
vented attic
4:12 = 18.435
1 2 3
FIN. FLR. @
EXISTING
MUDROOM
105'-8 3/4
T. SLAB @
EXIST. GARAGE
100'-0
T. PL. @
EXIST. GARAGE
+/-109'-1 1/8
T. BM. @
ENCLOSED STORAGE
+/-108'-1 1/8
T. PL. @
EXISTING
MUDROOM
114'-9 7/8
+/-9'-1 1/8"
EXIST.
DOOR
EXIST.
DOOR
NEW
DOOR
Cont.
Ventilation
Cont.
Airflow
EXISTING
GARAGE
SECTION
@ 1/4"= 1'-0"B
C
A4.2
FIN. FLR. @
EXISTING
MUDROOM
105'-8 3/4
T. SLAB @
EXIST. GARAGE
100'-0
T. PL. @
EXIST. GARAGE
+/-109'-1 1/8
T. BM. @
ENCLOSED STORAGE
+/-108'-1 1/8
T. PL. @
EXISTING
MUDROOM
114'-9 7/8
+/-9'-1 1/8"
T. PL. @
EXISTING
MUDROOM
+/-117'-3 7/8
VIF
+/-2'-6"
VIF
EXISTING ELEVATOR
REMOVE/REPLACE EXIST
SOFFIT TO APPLY SPRAY
FOAM INSULATION @
EXIST PORCH ROOF
CONNECTION(S)
EXISTING
ELEVATOR
CAB
EXIST.
WINDOW
Cont.
Ventilation
exist.
vented attic
Cont.
Airflow
EXIST.
WINDOW
4:12 = 18.435
5:12 = 22.62
NEW
ENCLOSED
STORAGE
ROOM
EXIST.
DOOR
EXISTING
STAIR
date: remarks:
2 4 8 FT0
GLENWOOD SPRINGS
919 Palmer Avenue
Glenwood Springs, CO 81601
Phone (970) 379-9239
Palomino Residential Design
jackpalomino55@gmail.com
Copyrigh
t Palomino Residential Design
Development
Building Design
Construction
23-0424 A4.1
job no: 23-0424
drawn by: xx
checked by: xx
date printed:xx
Kennedy Residence
Addition and Alterations
2074 CR 109
Glenwood Springs, Colora
do 81601
CLIMATE
ZONE
Group R
FENESTRATION
U-FACTOR b
SKYLIGHT
U-FACTOR
b GLAZED
FENESTRATION
SHGC b, e
SLAB
R-VALUE
& DEPTH
d CRAWLSPACE
WALL
R-VALUE
cCEILING
R-VALUE
WOOD
FRAME WALL
R-VALUE
5 0.30 0.55 NR 49
20
or
R-13+R5 h
R-10 for
24" Below R-15/19
EXCERPT FROM TABLE 402.1.2, 2018 IECC
INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT a
a R-values are minimums. U-factors and SHGC are maximums. Where insulation is installed in a cavity that is less than the label or
design thickness of the insulation, the installed R-value of the insulation shall not be less than the R-value specificed in the table.
NOTES:
d
e There are no SHGC requirements in the Marine Zone.
f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table R301.1.
g Alternatively, insulation sufficient to fill the framing cavity and providing not less than the R-value of R-19.
h The first value is cavity insulation, the second value is continuous insulation. Therefore, as an example, "13+5" means R-13 cavity
insulation plus R-5 continuous insulation.
i Mass walls shall be in accordance with Section R402.2.5. The second R-value applies where more than half of the insulation is on
the inteior mass wall.
NR = No Requirement
R-5 insulation shall be provided under the full slab area of a heated slab in addition to the required slab edge insualtion R-value for
slabs as indicated in the table. The slab edge insulation for heated slabs shall not be required to extend below the slabs.
FOR SI:1 Foot = 304.88 mm
b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration.
Exception: In Climate Zones 1 thrrough 3, skylights shall be permitted to be excluded from glazed fenestration SHGC
requirements provided that the SHGC for such skylights does not exceed 0.30.
c "10/13" means R-10 continuous insulation on the interior or eterior of the home or R-13 cavity insulation on the interior of the
basement wall.
"15/19" means R-15 continuous insulation on the interior or exterior of the home or R-19 cavity insulation at the interior of the
basement wall. Alternatively, compliance with "15/19" shall be R-13 cavity insulation on the interior of the basement wall plus R-5
continuous insulation on the interior or exterior of the home.
FLOOR
R-VALUE
R-15/19R-30 g
MASS
WALL
R-VALUE i
OPAQUE
DOORS
R-4.75
INSULATION NOTES:
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THAT ALL INSULATION AND FENESTRATION REQUIREMENTS ARE IN
COMPLIANCE WITH ALL CURRENT JURISDICTION APPLICABLE CODES AND THE ENERGY REPORT REGARDLESS OF THE SPECIFIC
INFORMATION IDENTIFIED ON THESE DOCUMENTS.
2.INSULATION INSTALLED WITHIN ALL BUILDING ASSEMBLIES (FLOOR-CEILINGS; ROOF-CEILINGS; WALLS; CRAWLSPACES; AND ATTICS)
SHALL COMPLY WITH FLAME SPREAD INDEX AND SMOKE-DEVELOPED INDEX FOR INSULATION PER IRC SECTION R302.10
1.
3.FOAM PLASTICS SHALL COMPLY WITH IRC SECTION R316 (eg IN CRAWLSPACE FOAM IN RIM JOIST).
R-13/17
BASEMENT
WALL
R-VALUE
c
GENERAL NOTES
1. DO NOT SCALE DRAWINGS - CONTACT ARCHITECT OR ENGINEER CONCERNING DISCREPENCIES OR MISSING
INFORMATION.
2. COMPLY WITH ALL APPLICABLE BUILDING CODES AND CONFORM WITH MATERIAL AND EQUIPMENT
MANUFACTURERS' RECOMMENDATIONS.
3. ALL DIMENSIONS TO FACE OF FRAMING UNLESS NOTED OTHERWISE.
4. EXTERIOR WALLS TO BE 2X6 @ 16" O.C. UNLESS NOTED OTHERWISE. REFER TO STRUCTURAL DRAWINGS.
5. INTERIOR WALLS TO BE 2x4 @ 16" O.C. UNLESS NOTED OTHERWISE. REFER TO STRUCTURAL DRAWINGS.
6. CROWN ALL STUDS, JOISTS, AND RAFTERS. CROWN JOISTS AND RAFTERS UP.
7. COORDINATE JOIST PLACEMENT WITH PLUMBING FIXTURE LAYOUT.
8. HOLD ALL PLUMBING TRAPS AS HIGH AS POSSIBLE. COORDINATE WITH CABINET ACCESSORIES.
9. NO VENT OR PLUMBING STACKS ARE TO BE LOCATED IN PARTY WALLS
10. THE UPPER LEVEL PLUMBING STACKS ARE TO BE CAST IRON UNTIL THEY REACH THE CRAWL SPACE.
11. THE PURPOSE OF THESE DRAWINGS IS ONLY TO GRAPHICALLY DEPICT THE GENERAL NATURE OF THE
WORK. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING DIMENSIONS AND SELECTING FABRICATION
PROCESSES AND TECHNIQUES OF CONSTRUCTION. THE ARCHITECT AND/OR ENGINEER SHALL BE NOTIFIED OF
ANY VARIATION FROM DIMENSIONS OR CONDITIONS SHOWN IN THE DRAWINGS.
1.
BUILDING THERMAL ENVELOPE
THE PERIMETER OF THE BUILDING THERMAL ENVELOPE IS DEFINED BY THE PERIMETER EXTERIOR WALL TYP., U.N.O.
2.THE BUILDING PERIMETER WALLS, INCLUDING PERIMETER CRAWLSPACE WALLS; PERIMETER WALLS AGAINST UNEXCAVATED AREAS
(RETAINING WALLS); CATHEDRAL CEILINGS; ATTIC CEILINGS; AND CONDITIONED FLOORS OVER NON-CONDITIONED SPACE WILL BE
INSULATED TO THE INSULATION STANDARDS IDENTIFIED ON THE BUILDING SECTIONS, TYP., U.N.O.
3.THE BUILDING PERIMETER WALLS, ARE FRAMED OF 2x6 STUDS @ 16" O.C., TYP., U.N.O.
03-01-24
Permit Submit
A4.2
BUILDING
SEC
TIONS
NEW 4" THK. REINF.
CONCRETE SLAB
SEE
DET.
5:12 = 22.62
new
vented attic
Cont.
Ventilation
Cont.
Airflow
Cont.
Airflow
9'-1 1/8"
8'-7 1/2"
NOTE:
CONTINUOUS RIDGE
VENT AND SOFFIT
VENTS TO PROVIDE
FOR VENTILATION
AT ATTIC, TYP.
existing
vented attic
EXISTING GARAGENEW GARAGE
9'-1 1/8"
A
A4.1
EXIST.
STAIR
LANDING
EXIST.
MUD-
ROOM
SECTION
@ 1/4"= 1'-0"C
B
A4.1
SOFFIT DIM.
SOFFIT DIM.
NOTE:
DRAWING INDICATES
THERMAL INSULATION AT
BUILDING ENVELOPE ONLY.
FOR THERMAL INSULATION
R-VALUES, SEE THERMAL
ENVELOPE SCHEDULE ON
THIS SHEET, TYP., U.N.O.
FOR ADDITIONAL ENERGY
NOTES AND AIR SEALING
REQUIREMENTS SEE
DETS. 1
A5.1
2
A5.1
TYP.
NEW
WINDOW
NEW
WINDOW
NOTE:
PROVIDE SOFFIT FOR HVAC
SUPPLY/RETURN AIR DUCTS, VERIFY
EXACT SOFFIT DIMENSIONS WITH
HVAC SUBCONTRACTOR IN THE
FIELD
8"
16'-4 1/2"
17'-0 1/2"
1'-4"
TRUSS
HEEL HEIGHT
FIN. FLR. @
EXISTING
MUDROOM
105'-8 3/4
T. SLAB @
EXIST. GARAGE
100'-0
T. PL. @
EXIST. GARAGE
+/-109'-1 1/8
T. BM. @
ENCLOSED STORAGE
+/-108'-1 1/8
T. PL. @
EXISTING
MUDROOM
114'-9 7/8
+/-9'-1 1/8"
T. PL. @
NEW GARAGE
117'-0 1/2
+/-7'-2 1/8"
CEIL. HEIGHT @ OPTIONAL LOFT
+/-10 1/4"
3/4" SUBFLOOR & 9 1/2" LVL @
OPTIONAL LOFT
-
-
NEW CONSTRUCTION EXISTING BUILDING
date: remarks:
2 4 8 FT0
GLENWOOD SPRINGS
919 Palmer Avenue
Glenwood Springs, CO 81601
Phone (970) 379-9239
Palomino Residential Design
jackpalomino55@gmail.com
Copyrigh
t Palomino Residential Design
Development
Building Design
Construction
23-0424 A4.1
job no: 23-0424
drawn by: xx
checked by: xx
date printed:xx
Kennedy Residence
Addition and Alterations
2074 CR 109
Glenwood Springs, Colora
do 81601
CLIMATE
ZONE
Group R
FENESTRATION
U-FACTOR b
SKYLIGHT
U-FACTOR
b GLAZED
FENESTRATION
SHGC b, e
SLAB
R-VALUE
& DEPTH
d CRAWLSPACE
WALL
R-VALUE
cCEILING
R-VALUE
WOOD
FRAME WALL
R-VALUE
5 0.30 0.55 NR 49
20
or
R-13+R5 h
R-10 for
24" Below R-15/19
EXCERPT FROM TABLE 402.1.2, 2018 IECC
INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT a
a R-values are minimums. U-factors and SHGC are maximums. Where insulation is installed in a cavity that is less than the label or
design thickness of the insulation, the installed R-value of the insulation shall not be less than the R-value specificed in the table.
NOTES:
d
e There are no SHGC requirements in the Marine Zone.
f Basement wall insulation is not required in warm-humid locations as defined by Figure R301.1 and Table R301.1.
g Alternatively, insulation sufficient to fill the framing cavity and providing not less than the R-value of R-19.
h The first value is cavity insulation, the second value is continuous insulation. Therefore, as an example, "13+5" means R-13 cavity
insulation plus R-5 continuous insulation.
i Mass walls shall be in accordance with Section R402.2.5. The second R-value applies where more than half of the insulation is on
the inteior mass wall.
NR = No Requirement
R-5 insulation shall be provided under the full slab area of a heated slab in addition to the required slab edge insualtion R-value for
slabs as indicated in the table. The slab edge insulation for heated slabs shall not be required to extend below the slabs.
FOR SI:1 Foot = 304.88 mm
b The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration.
Exception: In Climate Zones 1 thrrough 3, skylights shall be permitted to be excluded from glazed fenestration SHGC
requirements provided that the SHGC for such skylights does not exceed 0.30.
c "10/13" means R-10 continuous insulation on the interior or eterior of the home or R-13 cavity insulation on the interior of the
basement wall.
"15/19" means R-15 continuous insulation on the interior or exterior of the home or R-19 cavity insulation at the interior of the
basement wall. Alternatively, compliance with "15/19" shall be R-13 cavity insulation on the interior of the basement wall plus R-5
continuous insulation on the interior or exterior of the home.
FLOOR
R-VALUE
R-15/19R-30 g
MASS
WALL
R-VALUE i
OPAQUE
DOORS
R-4.75
INSULATION NOTES:
THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THAT ALL INSULATION AND FENESTRATION REQUIREMENTS ARE IN
COMPLIANCE WITH ALL CURRENT JURISDICTION APPLICABLE CODES AND THE ENERGY REPORT REGARDLESS OF THE SPECIFIC
INFORMATION IDENTIFIED ON THESE DOCUMENTS.
2.INSULATION INSTALLED WITHIN ALL BUILDING ASSEMBLIES (FLOOR-CEILINGS; ROOF-CEILINGS; WALLS; CRAWLSPACES; AND ATTICS)
SHALL COMPLY WITH FLAME SPREAD INDEX AND SMOKE-DEVELOPED INDEX FOR INSULATION PER IRC SECTION R302.10
1.
3.FOAM PLASTICS SHALL COMPLY WITH IRC SECTION R316 (eg IN CRAWLSPACE FOAM IN RIM JOIST).
R-13/17
BASEMENT
WALL
R-VALUE
c
GENERAL NOTES
1. DO NOT SCALE DRAWINGS - CONTACT ARCHITECT OR ENGINEER CONCERNING DISCREPENCIES OR MISSING
INFORMATION.
2. COMPLY WITH ALL APPLICABLE BUILDING CODES AND CONFORM WITH MATERIAL AND EQUIPMENT
MANUFACTURERS' RECOMMENDATIONS.
3. ALL DIMENSIONS TO FACE OF FRAMING UNLESS NOTED OTHERWISE.
4. EXTERIOR WALLS TO BE 2X6 @ 16" O.C. UNLESS NOTED OTHERWISE. REFER TO STRUCTURAL DRAWINGS.
5. INTERIOR WALLS TO BE 2x4 @ 16" O.C. UNLESS NOTED OTHERWISE. REFER TO STRUCTURAL DRAWINGS.
6. CROWN ALL STUDS, JOISTS, AND RAFTERS. CROWN JOISTS AND RAFTERS UP.
7. COORDINATE JOIST PLACEMENT WITH PLUMBING FIXTURE LAYOUT.
8. HOLD ALL PLUMBING TRAPS AS HIGH AS POSSIBLE. COORDINATE WITH CABINET ACCESSORIES.
9. NO VENT OR PLUMBING STACKS ARE TO BE LOCATED IN PARTY WALLS
10. THE UPPER LEVEL PLUMBING STACKS ARE TO BE CAST IRON UNTIL THEY REACH THE CRAWL SPACE.
11. THE PURPOSE OF THESE DRAWINGS IS ONLY TO GRAPHICALLY DEPICT THE GENERAL NATURE OF THE
WORK. THE CONTRACTOR IS RESPONSIBLE FOR CONFIRMING DIMENSIONS AND SELECTING FABRICATION
PROCESSES AND TECHNIQUES OF CONSTRUCTION. THE ARCHITECT AND/OR ENGINEER SHALL BE NOTIFIED OF
ANY VARIATION FROM DIMENSIONS OR CONDITIONS SHOWN IN THE DRAWINGS.
1.
BUILDING THERMAL ENVELOPE
THE PERIMETER OF THE BUILDING THERMAL ENVELOPE IS DEFINED BY THE PERIMETER EXTERIOR WALL TYP., U.N.O.
2.THE BUILDING PERIMETER WALLS, INCLUDING PERIMETER CRAWLSPACE WALLS; PERIMETER WALLS AGAINST UNEXCAVATED AREAS
(RETAINING WALLS); CATHEDRAL CEILINGS; ATTIC CEILINGS; AND CONDITIONED FLOORS OVER NON-CONDITIONED SPACE WILL BE
INSULATED TO THE INSULATION STANDARDS IDENTIFIED ON THE BUILDING SECTIONS, TYP., U.N.O.
3.THE BUILDING PERIMETER WALLS, ARE FRAMED OF 2x6 STUDS @ 16" O.C., TYP., U.N.O.
03-01-24
Permit Submit
SI D IN G PE R F AC AD E
EL EVAT I ON S, T YP .
C ON C R ET E F O UN D AT I ON
ST EM W ALL & C ON T IN U OU S
F OOT I N G PER ST RU C T . D W GS.
RO OF IN G M ATER IALS, PR OVID E R OOF
CO VER IN GS CLASSIF IE D PER S EC. R 90 2
AN D MAT ERI ALS C OMPLYI NG WI TH SEC
R 904, SEE R OOF PLAN, SH T. A1.1
WA LL S ECT IO N
@ 3/4"= 1'-0"2
C ON T IN U OU S F D N.
D R AI N, SEE SO IL S
R EPO RT
C ON T IN U OU S R AD ON PI PE
LO OP, I N ST ALL ED A T OW N ER 'S
R EQU E ST
ROOF PIT CH,SEE ROOFPLAN, TYP.
PR EF AB T R U SS w / APP R OVED
T R US S CO NN E CT OR AT EAC H
T R US S PER SEC . R 80 2.1 1,
R EF . ST R U C TU R AL ,
T H E C O NT R AC T OR SH ALL
PR OV ID E T O T HE B UI LD I NG
D EPA RT M EN T TH E
M AN U F AC TU R ER 'S
I NS TA LLA TI ON AN D BR A CI N G
R EQU I R EM EN T S PR IO R T O
F R AM IN G I N SPEC T I ON
C EI LI NG I N SU LAT I ON , SE E
BU I LD IN G SE C TI ON S
GY P. BD . I N T ER IO R W AL L F I N IS H,
T YP.
M OI ST U RE V APO R R ET AR D ER ,
PR OV ID E AN APP RO VED
M OI ST U RE V APO R R ET AR D ER
I NS TA LLE D ON TH E
W AR M -I N-W IN T ER S ID E OF TH E
I NS U LAT IO N S EC R 70 2.7 ,
6 M IL . VI SQU EE N O R APP R OVED
EQ UA L
T . W IN D OW H EAD ,
PE R F AC AD E
EL EVAT I ON S
T. S LAB ,
SE E S ECTIONS
T. FTG.,
SE E S TRUCT.
T. CONC. W AL L
SE E S TRUCT.
T. TOP PL ATE,
SE E S ECTIONS
T . W IN D OW H EAD ,
PE R F AC AD E
EL EVAT I ON S
GY P. BD . I N T ER IO R C EI LI N G
F IN I SH , T YP .
NO TE:
1.) PECO RA FLEX IB LE CAULKING A ND PRE-INSULA TION
IN THE TO P AND BOTT OM P LATE, GA P S IN STUD PACKS
A ND FRAMING .
2.) FO AM ALL PENE TRATIONS B ET WEEN FLOO RS AND
E XT ERIO R WALLS.
3.) FO AM IN EVERY A IR BA FFLE TO THE TRUS S B AYS.
CO NFIRM NO AIR LEAKAG E AROU ND TO THE ATTIC.
W OOD F RAMING NOTES:
1.) WOO D SP E CIES FO R BUILDING COMP ONENTS SHALL
BE AS SP E CIFIED PER THE FOLLO WING CODE
SECT IONS:
FLO ORS - SEC. R502.1;
W ALLS - SEC. R602.1; AND
RO OF/CE ILING - S EC. R802.1
2.) RO OF T RUSS E S - THE CONTRACTO R SHALL PROVIDE
ENGINEE RED PREFAB RO OF T RUSS SHOP DRA WING S
THA T A RE ST AMP ED AND SIGNED BY A COLO RADO
LICENSED PROFS SIONAL ENG INE ER
I NS UL AT ED WI N D OW H E AD ER ,
T YP.
2x STU D WAL L w/ PR ESSUR E
TR EATED SI LL PL ATE A ND AN CH OR
BOLT OVER SI LL SEALER , SEE
ST RUC T . D W GS. TYP.
4' T HI CK UN HEAT ED REI NF ORC ED
CO NCR ETE SLAB O N GRAD E
OVER SPR AY F OAM IN SU LAT ION
AN D COMP AC T ED BA CKF ILL PE R
SOIL S REP ORT , T YP.
CO MPRESSI BLE SE AL AT SLAB
PER IM ET ER
C ON T . D AM PR OO FI N G
AN D RI GI D I N SU LAT I ON
BO AR D AT ST EM W ALL
W I ND OW PER F LOO R
PL AN /F AC AD E
EL EVAT I ON S, T Y P.
C ON T IN U OU S
PE RI M ET ER ZI P-R
EX TE RI OR
I NS UL AT IO N
SH EA TH I N G AN D
W EAT H ER BAR R I ER ,
T YP.
TRUS
S
HE
EL
HEI
GHT
V
ARI
ES,
SEE SECTI
ON
S
GR ID
PLY. ROOF SH EATH IN G, SEE ST R UCT .
DW GS., T YP.
IN SULAT I ON BAF FL E FOR R OOF
VENT IL AT ION , WH ERE OCC UR S, VERI FY
LOCAT IO NS I N TH E F I ELD
DR AWI NG IN DI CA TES I NSU LATI ON IN R OOF/CEI LIN G/W ALLS/ SUB-GR ADE WA LLS AN D
FLOOR S. FOR SP EC IF IC M IN IM UM R -VALU ES OF IN SULA TI ON R EFER T O T HE BUI LDI NG
SECT ION S, T YP., U .N .O.
THE GEN ERA L CONTRA CTOR S HA LL BE R ESPO NS IBLE FOR V ERI FYIN G TH AT A LL
IN SULA TION AN D FEN ESTRA TION REQ UIR EMEN TS AR E IN CO MPL IAN CE WITH A LL
CURR ENT J UR IS DICTION AP PLICA BLE COD ES A ND TH E ENER GY R EPO RT R EGAR DLE SS
O F TH E SPE CI FIC INFORMATION IDEN TIFIED O N THE SE D OCUMEN TS .
3.IN SULA TION INS TA LL ED W ITH IN A LL BUILD ING A SS EMBLIES (FLOOR -CEIL INGS ;
ROO F-CEIL INGS ; W AL LS; CRAW LSPA CES ; AND ATTICS) S HAL L COMP LY W ITH FLA ME
SP REA D IN DEX AN D SM OKE-DEV ELO PED I NDE X FO R IN SULA TION PER IRC S ECTI ON
R302.10
2.
4.FOAM PL AS TI CS SH ALL COMP LY W ITH IRC S ECTION R316 (eg IN CR AW LS PACE FO A M
IN RIM J OIS T).
IN SULAT I ON N OTES:
1.
C ont.
Airflow
C ont.
Ai rfl ow
VE NT ED
AT T IC
PR EF AB . VE NT ED
SO FF I T BO AR D O R
C ON T IN U OS S OF FI T
VE NT , P R OVI D E
C LEA R VE NT I N G TO
C ON T IN U U S RI D GE
VE NT
CONT. 2 4 GA UGE
FLA SHING TO PROTECT
INSUL ATION, COL OR AS
SE LECTED TO MA TCH
ADJACE NT S URFA CE S
AND/OR A S S ELE CTE D
BY THE OW NER
N OTE: WALL SECTIO N DEPI CT S ID EALIZED BUILDING COMPO NENTS
AND INSULATI ON CONDI TIO NS. FO R SPECI FIC PR OJECT CO ND IT IONS SEE BU ILD IN G SECTI ON S.
F LOO R SY ST EM , W H ER E
OC C U R S, SE E PLAN , P R OVI D E
SP RA Y FO AM I N SU LA TI ON AT
R IM J OI ST
C. IF ANY DUCT S ARE INSTALL E D IN AN AT TIC OR GA RAGE OR UNCONDITIONE D OR
UNH EATED CRAWL SPACE, A DUCT L EAK TEST WILL BE P E RFORMED A ND PR OVIDED
TO THE B UILDING D EPA RTMENT FOR APPROVAL .
E. M EA NS OF COND IT IONING CRA WL SPACE :
NO RETURN A IR REGISTER IN C RAW LSPAC E. S UPPL YING CONDITIONED AIR FROM
FORCED A IR HEAT AND COOLING SYSTEM .
A. M AND ATORY RE QUIREM EN TS
SEC TION 4 02 .2.3 IE CC:
ACCE SS HA TCHES BETWE EN CONDITIONED A ND U NCONDITIONE D SPA CES TO BE
WE ATHER ST RIPPED AND INSUL A TED TO A L EVEL E QUIV AL EN T TO INSUL ATION
L EVEL OF SU RROUNDING S URFACE S.
SEC TION 4 02 .4 IEC C: A IR SEAL IN G MEASU RE S SH AL L BE P ROVIDED AT THE
FOLL OWING LOCATIONS -
1 ) DRY WALL AT TH E ATTIC TOP PLATE WILL BE SEALED W ITH D OU BLE STICK MASTIC
BEF OR E INSTAL L IN G DR YW AL L OR CAUL KE D FROM ABOVE AFTER DRYW AL L IS
INSTAL L ED.
2 ) AL L RECE S SED LIGHTING SHAL L B E AIR TIGHT WITH SEAL ED TR IM R IN GS . AL L
RECE SSED LIGHTING FIXT URES BET WE EN COND IT IONED A ND UNC ON DITIONED
SPACE S SHA L L BE RATED FOR IN SUL ATION C ON TAC T.
3 ) A L L DUC T BOOTS SHA LL BE SEALED W ITH M ASTIC TO FLOOR OR ADJACE NT W AL L
OR CEIL ING SUR FAC E.
4 ) RIM (BAND) JOIST OR SILL PL ATE SH AL L BE C AULK ED TO SEAL AL L AIR
INFIL TRA TION. JOIS T CAVITIE S SHA LL BE FILL ED S OLID W IT H FOAM.
5 ) CHA S ES LEA VING CONDITIONE D SPA CE AND ENTE RING VE NTIL ATED ATTIC SH AL L
BE DR AFT STOP AND SEA LE D AIR TIGHT W ITH FOAM OR CAULK.
6 ) STAIRS, BATHTUB S, FIRE P LA CES, AND POR CH ROOF(S) ME E TIN G EXTER IOR W AL LS
SHA LL BE SE ALED WITH AN AIR BA RRIE R IN TH ES E L OCATION S COVER IN G THE
EXPOSED B ATT IN SUL ATION W ITH PL Y WOOD, D RYW ALL OR OTHER APPROV ED A IR
BAR RIER.
7 ) THE WA L L BETW EEN THE GAR AGE AND TH E HOUS E SHA L L BE TREATED AS AN
EXT ERIOR WA L L. AL L PENE TRATIONS, GAPS AND POTEN TIAL L E AK A REAS SHAL L BE
CAUL KE D, FOAM ED , SEAL ED OR GASK E TED . INCL UDING B LOCKING AND R IM JOIST.
8 ) ALL MECHA NICA L, PLUM BING AN D EL E CTRICAL PE NET RAT IONS SH AL L B E
CAUL KE D, FOAM ED , SEAL ED OR GASK E TED .
9 ) ANY C ON DITION TH AT W IL L R EQUIRE SPECIAL KN OW LE DGE OR EFFORT DUR IN G
CONSTRU CTION .
SEC TION 4 02 .4.5 IE CC:
THE IC (INSULA TION CONTACT) RATED F IX TUR ES AN D AIR SEALIN G REQUIREMENTS
W IL L B E ADHE RED TO IF R ECESSED L IGHT IN G IS U SED B ETW EE N COND ITIONE D A ND
UNC ON DITION ED S PACES.
SEC TION 4 03 .2.2 IE CC:
IF ME CHANICAL S YS TEMS OR D UCT WORK IS L OC ATED OUTS IDE TH E THERM AL
ENV EL OPE (IE, GARAGE , UN CONDITION ED C RAW LSPAC E OR ATTIC) THEN THE
SYSTE M MU ST PA SS TOTAL DU CT LEA KA GE OR DUC T LE AKAGE TO OUTDOOR TEST.
THE TEST RESULT S SHALL BE PR OVIDE D TO/BY T HE P ROJECT EN ERGY
CONSUL TANT.
SEC TION 4 04 IE CC :
THE LIGHTING EF FIC AC Y OF 9 0 % OF A LL L IGHTING F IX TUR ES MUS T QUAL IFY A S H IGH
EFFICAY.
B. SPECIFIC 2 01 5 IRC REQUIREMENTS;
SEC TION 3 03 .4 IRC: AS HR AE STAND ARD 6 2 .2 -2 01 9 , VEN TILA TION AND ACCE PTABL E
INDOOR AIR QUALITY IN LOW-RISE RESIDENTIAL BUL DINGS -
THE HVAC SUBCONTR AC TOR WIL L A SS IST W ITH CALC ULATIONS AS NEED ED FOR
THE REQU IR ED VENTILATION SY STEM COMPON EN TS OF THE BU IL DING THA T WILL
ME E T ASHRAE S TA NDARD 6 2.2-2 01 9.
D. EQUIPMENT S PECIFICATION S. B AC K DRAFT TE S TS W IL L B E PE RFORME D A ND
PROVIDE D BY/TO THE E NERGY CONSU LTANT AND THE B UILDIN OFFICIAL FOR
POWER VENT OR OPEN COMBUSTION MECHA NICA L EQU IPME NT.
F. WHOL E HOUSE VENTILATION SY S TEM:
WH ER E THE AIR INFIL TRATION RATE OF A DWELL ING IS LESS THAN 5 AIR CHANGE S
PER H OU R, T HE DW E LLIN G UN IT SHA LL BE P ROVIDED WITH A WHOL E HOUSE
ME CHANICAL V E NTILATION SYSTEM IN ACCORD AN CE W IT H SE CTION M1 507.3
ENER GY CON SER VA TIO N CO DE N OTES1
G
LENW
OO
D SPRING
S
919 Pa
lme
r A
ve
nue
Glenwood
Springs,
CO
81601
Phone
(970)
379-9239
Palomino
Resid
entia
l D
esign
Deve
lopm
en
t
Bu
ild
ing Desi
gn
C
on
struction
jack
palo
mino
55@gmail.c
om
Copyright
Pal
omino Residen
tia
l
Design
23-0424 A5.1
date
:
re
ma
rks:
job no:
23-0424
dra
wn
by:
JP
che
cke
d by:
JP
da
te
pr
inte
d:
xx
WALL SEC
TION,
ENERG
Y NOTES
A5.1
03
-01-2
4
Permit
Su
bmit
Kennedy Resid
en
ce
Addition a
nd Altera
tions
2074 CR 109
Glenwood Springs,
Colorado
81601
GAS-FIREDBOILER24"x24"VIF
GAS-FIREDFAU24"x24"VIF
UP
2R
R=7 1/2"
T=11"
EXISTING
ELEC MAIN
DISCONNECT
PANEL
EXISTING ELEC
CONDUIT TO
EXISTING
DISCONNECT
PANEL
HOSE
BIBB
EXIST 1/2 STOP
PASS-THRU
ELEVATOR
45 DEGREE
WINDER TREAD
ENTRY LEVEL ELECTRICAL PLAN
@ 1/4"= 1'-0"NORTH
ENTRY LEVEL
ELECTRICAL PLAN
E2.2
ELE CTRICAL LEGEND
RECESSED CEILING FIXTURE
LSURFACE MOUNTED CEILING FIXTURE
SURFACE MOUNTED WALL FIXTURE (SCONCE)
LIGHT TRACK AND LENGTH
DIRECTIONAL SPOT LIGHT FIXTURE
VANITY LIGHTS
EXHAUST FAN
EXHAUST FAN WITH LIGHT
F
HEAT, LIGHT, VENT
HEATER
JUNCTION BOX FOR FAN
JUNCTION BOX FOR OWNER SUPPLIED LIGHT FIXTURE
STEP LIGHTS
RECESSED WALL MOUNT LIGHTS
GARDEN LIGHTS
FLUSH MOUNT GROUND LIGHTS
DUPLEX RECEPTACLE
T
TV
S
3 L.F.
S
3S
A,B,ETC.S
RS
4S
TS
1/2 SWITCHED RECEPTACLE
WATERPROOF RECEPTACLE
SPECIAL OUTLET - RE: PLAN
SINGLE POLE SWITCH
THREE WAY SWITCH
FOUR WAY SWITCH
RHEOSTAT (DIMMER) SWITCH
SPECIALTY SWITCH
SWITCH ON TIMER
THERMOSTAT
TELEVISION OUTLET
TELEPHONE JACK
INTERCOM
SMOKE DETECTOR
GARBAGE DISPOSAL
ELECTRICAL PANELBOARD
J JUNCTION BOX
NOTES:
1. ALL SWITCHES SHALL BE MOUNTED @ +48" A.F.F. TYP., U.N.O.
2. ALL OUTLETS SHALL BE MOUNTED @ +12" A.F.F. TYP., U.N.O.
3. OUTLETS AT COUNTERTOPS SHALL BE MOUNTED @ +44" A.F.F. TYP., U.N.O.
4. CONTRACTOR TO VERIFY WITH OWNER LOCATION AND METHOD FOR POWER TO HEAT TAPE SYSTEM
W.P.
DUPLEX FLOOR RECEPTACLE
OSS SWITCH ONOCCUPANCY SENSOR
GROUND FAULT INTERRUPTORGFI
WATERPROOF GROUND FAULTINTERRUPTOR RECEPTACLEW.P.GFI
SP 2/1 SPEAKER, "2 1N 1" TYPE
A/V AUDIO/VISUALINTERCONNECT
UNDER CABINET LIGHT
SP SPEAKER
O
SURFACE MOUNTED LIGHT
1. NO LESS THAN 90 PERCENT OF THE PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL CONTAIN ONLY HIGH EFFICACY LAMPS, R404.1.
2. ALL HIGH EFFICACY LAMPS INSTALLED WILL BE LED (LIGHT-EMITTING DIODE) TYPE.
ELECTRICAL POWER AND LIGHTING SYSTEMS NOTES
NOTE:
LOCATE NEW ELEVATOR ELEC
DISCONNECT PANEL TO MEET MIN.
CLEARANCE REQUIREMENTS FOR
SERVICE ACCESS, VERIFY EXACT
LOCATION, w/ THE EQUIPMENT
MANUFACTURER
(E)(E)(E)
W.
P.
GFI
J
KP
(E)(E)(E)
W.P.
GFI
W.
P.
GFI
(E)
(E)
(E)(E)
(E)
W.P.
GFI
(E)
(E)
S
3S
(E)(E)
S S
(E)(E)
S
3S3S3S
3S3
S
3
S3
S
3S
3S
3S
3S
3S
CEIL. MTD.
OUTLET FOR
GARAGE DOOR
OPENER
CEIL. MTD.
OUTLET FOR
GARAGE DOOR
OPENER
(E)
S
3
S(E)
4S(E)
(E)
3S(E)
PROVIDE 30 AMP/230V
OUTLET FOR R/V USE,
VERIFY EXACT PLUG TYPE
AND LOCATION IN THE
FIELD
PROVIDE AFCI/GFCI
PROTECTED OUTLET AT
THE GARAGE, TYP. U.N.O.
PROVIDE WALL MTD.
LIGHTING FIXTURES
ALONG EAST AND WEST
WALLS, VERIFY EXACT
MOUNTING HEIGHT IN THE
FIELD TYP.
NOTE:
"E" DENOTES EXISTING
ELECTRICAL FIXTURE, OUTLET
OR DEVICE AND WILL REMAIN
AS INSTALLED, TYP. U.N.O.
W.P.
GFI
3STO LOFT ABV
TO LIGHTING
CONTROL SWITCH
BELOW
3S
W.P.
GFI
W.P.
GFI
S
24-0424 A2.2
date: remarks:
job no: 24-0424
drawn by: xx
checked by: xx
date printed:xx
2 4 80
GLENW
OOD SPRINGS
815 Blake Avenue
Glenwood Springs, CO 81601
Phone (970) 947-9014
Fax (970) 947-9137
Palomino Design-Build PC
www.palominodesignbuild.com
Copyright Palomino Design-Build PC
Architecture
Development
Construction
Kennedy Residence
Addition and Alterations
2074 CR 109
Glenwood Springs, Colorado 81601
03-01-24
Permit Submit
B D
A
A4.1
D
C
A4.2
A
A4.1
B
A4.1
B
A4.1
C
A4.2
A
BA
2
7
3
5
1
C
C
4
6