HomeMy WebLinkAboutEngineer's OWTS Design129 Cains Lane
Carbondale, CO 81623
970.309.5259
carla.ostberg@gmail.com
April 29, 2024 Project No. C1870
Dorothy Bleakley
Dbleakley14@gmail.com
Subsurface Investigation and Onsite Wastewater Treatment System Design
4-Bedroom Residence
387 Meadow Lane
Garfield County, Colorado
Dorothy,
CBO Inc. performed a subsurface investigation and completed an onsite wastewater treatment system
(OWTS) design for the subject residence. The 1.059-acre property is located outside of Glenwood
Springs, in an area where OWTSs are necessary.
Legal Description: Section: 35 Township: 6 Range: 89 Subdivision: WESTBANK RANCH SUB. #3 Lot: 28
Parcel ID: 2185-354-03-028
SITE CONDITIONS The property is currently developed with a 4-bedroom residence. The residence is served by an existing
OWTS that consists of a 1000-gallon, two-compartment concrete septic tank followed by a 12’ x 40’ pipe
and gravel soil treatment area (STA) with 3-feet of gravel under the distribution piping. Garfield County
Individual Sewage Disposal System Permit 1679 documents this system. The system was sized to
accommodate 3-bedrooms. The permit received final approval from Garfield County on December May
31, 1989.
The existing STA is experiencing slow draining and must be replaced.
The residence is served potable water from a community water system. The new STA must be at least
25-feet from any water line; however, as this is a repair and space on the property for the replacement is
limited, we may encroach slightly on the setback to the water line that runs along the eastern side of the
property. We have approximated the water line on our site plan, but the water line was located on the
property.
The proposed soil treatment area (STA) location has an approximate five percent slope to the northeast.
The proposed area is vegetated with sage and native grasses.
There should be no traffic or staging of material over the future STA site to avoid compaction of soils
prior to construction of the STA.
Page 2
Waterline as it angles into the house
Waterline as it comes up the eastern property line
Waterline middle of subdivision road Curb stop
Page 3
View of approx. water line Curb stop
View of approx. areas for STA
SUBSURFACE
The subsurface was investigated on March 18, 2024 by digging two soil profile test pit excavations (Test
Pits). A visual and tactile soil analysis was completed by Carla Ostberg at the time of excavation.1
Excavation was done in an effort to see if there was a broken sewer line after the septic tank; however, it
was evident that the STA was saturated and both excavations encountered saturation in the existing STA.
The soils are consistent with Soil Type R-0 with greater than 35% rock. A pressure-dosed, unlined sand
filter with a minimum of 3-feet of sand filter material (Secondary Sand) is proposed. A long-term
acceptance rate (LTAR) of 0.8 gallons per square foot will be used to design the STA.
1 Carla Ostberg holds a Certificate of Attendance and Examination from the CPOW Visual and Tactile
Evaluation of Soils Training.
Page 4
Inspection port between septic tank and STA / sewer line between septic tank and STA
Trench (sand and gravel)
Page 5
Excavation to trouble-shoot
Additional test pit to the east Encountered saturation 5-feet
Page 6
Test Pit #2
DESIGN SPECIFICATIONS The existing septic tank will be abandoned by pumping the tank and removing it or crushing the top,
bottom, and sides and filling in the void with onsite materials. The existing STA will be abandoned in
place.
Design Calculations:
Average Design Flow = 75 GPD x 2 people/bedroom x 3 Bedrooms + 75 GPD (4th Bedroom) = 525 GPD
LTAR = 0.8 GPD/SF
525 GPD / 0.8 GPD/SF = 656.25 SF
The OWTS design is based on 4-bedrooms. An average daily wastewater flow of 525 GPD will be used.
For the purposes of this OWTS design, Benchmark Elevation has been established as 100’ (Finished
Floor). CBO Inc. should be notified of any discrepancies or problems with grade elevations of proposed
components during installation of the OWTS.
OWTS Component Minimum Elevation
Primary Tank Inlet Invert (existing sewer line) Approximate horizontal distance 32’ / min. 2% fall /
min. 8” fall
Automatic Distributing Valve Approximate horizontal distance 6’ / min. 1% rise /
min. 0.75” rise
Infiltrative Surface Approximate horizontal distance 61’ to furthest bed
/ min. 1% fall to STA / min. 7.625” fall
*Elevations are based upon standard OWTS installation practices. Component elevations may change during
installation due to site conditions. Minimum grade refers to piping between components.
The 4-inch SDR-35 sewer line exiting the residence must have a double-sweep clean out and a minimum
2% grade to the septic tank. The existing sewer line may remain in use as long as it is in good condition.
The system installation will include a 1500-gallon, two-compartment Valley Precast concrete septic tank
with an Orenco® Biotube Pump Vault and an Orenco® PF3005 pump in the second compartment of the
septic tank. The floats should be set to dose approximately 61 gallons each pump cycle, allowing
approximately 1 gallon of drain back. The control panel for the pump must be located within line of sight
of the septic tank. An electrician will be responsible for wiring the pumping system and the contractor will be
responsible for connecting the plumbing. This office should be contacted for start up of the system to verify
its functioning and to perform a squirt test prior to use of the system.
Page 7
Pump Table
Dose Range Max = 132.25 gal. (525 GPD x
25% + 1 gallon drain back)
Min. 53 gal. (13 gal x 4) + 1 gal
drain back
Dose Setting 61 gallons/dose 1 gallon drain back (6’ / 1.5”
diameter pump line)
Float Separation 1500 gallon 2-compartment
Valley Precast concrete septic
tank
6” on/off float separation
Pump Criteria 17.6 gallons per minute (GPM) 15.3 feet total dynamic head
(TDH)
Effluent will be pumped through a 1.5-inch diameter pump line from the pump chamber to an Orenco®
automatic distributing valve (ADV), model 6402. This pump line must have a minimum 1% grade for proper
drain back into the tank after each pump cycle. The ADV must be placed at a high point in the system in an
insulated riser with access from grade. Screened rock must be placed below the ADV to support the ADV
and to assure the clear pipes exiting the ADV remain visible for future inspection and maintenance.
Effluent will be pressure dosed to through 1.5-inch diameter distribution lines to two 10’ x 33’ beds. A
minimum of 3-feet of sand filter material will be installed in the over-excavated footprints. Sand filter material
must be clean, coarse sand, all passing a screen having four meshes to the inch. The sand must have an
effective size between 0.15 and 0.60 mm. The uniformity coefficient must be 7.0 or less. Material meeting
ASTM 33, for concrete sand, with three percent or less fines passing 200 mesh sieve may be used. A
gradation of the sand media must be submitted to this office prior to obtaining the sand.
Laterals must be 1.5-inches in diameter with 5/32-inch diameter orifices facing down, spaced 2.5-feet on
center, installed on the GeoMat™ with the filter fabric over the laterals. Laterals should be placed 2-feet
from the edges of the bed with 3.0-feet between the laterals. Laterals will be connected with 1.5-inch
diameter level manifolds. Three 39” wide GeoMat™ sheets must be placed on the 10-foot wide bed. All
material associated with the GeoMat™ installation must be proprietary products associated with the
GeoMat™, including orifice shields and geotextile fabric. Manufacturer instructions must be followed
regarding installation of the GeoMat™.
Each 1.5-inch diameter lateral must end in a sweeping ell facing up with a ball valve for flushing. Valves
should be placed in a 10-inch sprinkler box for access. Laterals must be covered by a soil separation
fabric and at least 1-foot of topsoil or other suitable soil able to support vegetative growth. There shall be no
cobble-sized (>2.5”) or greater rock in final cover over the GeoMat™. Inspection ports must be placed at
each corner of each bed. Ports may be cut to grade and covered with a valve box for access.
COMPONENT SPECIFICATIONS
The component manufacturers are typical of applications used by contractors and engineers in this area.
CBO Inc. must approve alternative components prior to installation of the OWTS. Requests must
be submitted, in writing, to our office for approval prior to installation. Component technical data
sheets are available upon request.
COMPONENT MANUFACTURER MODEL NO. COMMENTS
Septic Tank Valley Precast Item # 1500T-2CP-HH 1500-gallon, 2-
compartment concrete
septic tank with high
head pump
Pump Orenco® PF300511 ½ HP
120 Volt
Page 8
Biotube ProPak Pump Package Orenco® BPP30DD Vault, Filter, Control Panel (demand dose)
Tank Risers and Lids Orenco® Double-walled PVC Risers and Lids (24” diameter)
ADV Orenco® V6402A 1.5” Inlet and Outlets
ADV Riser and Lid Orenco® Double-walled PVC Risers
and Lids (30” diameter) Flushing Assembly Orenco® 1.5” diameter (2) 45° or 90° long sweep only (8 total) GeoMat™ GeoMatrix Systems, LLC 198 linear feet 39” wide GeoMat™ and 72 orifice shields
Construction must be according to the jurisdiction’s adopted On-Site Wastewater Treatment System
Regulations, the OWTS Permit, and this design.
PERMIT APPLICATION INSTRUCTIONS
An OWTS Permit Application must be submitted to Garfield County Environmental Health Department.
https://www.garfield-county.com/environmental-health/filesgcco/sites/16/OWTS-Application-Complete-
Packet-Dec.-2019.pdf. If the OWTS Permit Application will be submitted with a Building Permit
Application, it should be submitted directly to Garfield County Building Department.
All questions regarding permit submission can be directed to Garfield County Environmental Health
Department, 970-945-6614 x8150.
INSTALLATION CONTRACTOR
CBO Inc. expects that the installer be experienced and qualified to perform the scope of work outlined in this
design. The installer must review this design thoroughly and coordinate with our office in advance of
installation. Any additional conditions in this design or county permit must be completed and documented
prior to final approval of the OWTS installation. Communication between the installer and this office is
expected throughout the installation.
INSTALLATION OBSERVATIONS CBO Inc. must view the OWTS during construction. The OWTS observation should be performed before
backfill, after placement of OWTS components. Septic tanks, distribution devices, pumps, dosing
siphons, and other plumbing, as applicable, must also be observed. CBO Inc. should be notified 48 hours
in advance to observe the installation.
In an effort to improve the accuracy of the record drawing, we request that the installer provide a
sketch of the installation, including path of the sewer lines, water line installation (if applicable),
septic tank location, STA location, and measurements from building corners or another fixed
objects on the property. This sketch is most easily provided on Sheet W2.0 of the OWTS Design
Packet. Photographs of the installation and final cover are also requested to supplement our installation
documentation.
REVEGETATION REQUIREMENTS
An adequate layer of good quality topsoil capable of supporting revegetation shall be placed over the entire
disturbed area of the OWTS installation. A mixture of native grass seed that has good soil stabilizing
characteristics (but without taproots), provides a maximum transpiration rate, and competes well with
successional species. No trees or shrubs, or any vegetation requiring regular irrigation shall be placed over
Page 9
the STA. Until vegetation is reestablished, erosion and sediment control measures shall be implemented
and maintained on site. The owner of the OWTS shall be responsible for maintaining proper vegetation
cover.
OPERATION INFORMATION AND MAINTENANCE
The property owner shall be responsible for the operation and maintenance of each OWTS servicing the
property. The property owner is responsible for maintaining service contracts for manufactured units,
alternating STAs, and any other components needing maintenance.
Geo-fabrics or plastics should not be used over the STA. No heavy equipment, machinery, or materials
should be placed on the backfilled STA. Machines with tracks (not wheels) should be used during
construction of the STA for better weight distribution. Livestock should not graze on the STA. Plumbing
fixtures should be checked to ensure that no additional water is being discharged to OWTS. For example, a
running toilet or leaky faucet can discharge hundreds of gallons of water a day and harm a STA.
If an effluent filter or screen has been installed in the OWTS, we recommend this filter or screen be cleaned
annually, or as needed. If the OWTS consists of a pressurized pump system, we recommend the laterals be
flushed annually, or as needed.
The homeowner should pump the septic tank every two years, or as needed gauged by measurement of
solids in the tank. Garbage disposal use should be minimized, and non-biodegradable materials should not
be placed into the OWTS. Grease should not be placed in household drains. Loading from a water softener
should not be discharged into the OWTS. No hazardous wastes should be directed into the OWTS.
Mechanical room drains should not discharge into the OWTS. The OWTS is engineered for domestic waste
only.
ADDITIONAL CONSTRUCTION NOTES If design includes a pump, weep holes must be installed to allow pump lines to drain to minimize risk of
freezing. The pump shall have an audible and visual alarm notification in the event of excessively high-
water conditions and shall be connected to a control breaker separate from the high-water alarm breaker
and from any other control system circuits. The pump system shall have a switch so the pump can be
manually operated.
Excavation equipment must not drive in the excavation of the STA due to the potential to compact soil.
Extensions should be placed on all septic tank components to allow access to them from existing grade.
Backfill over the STA must be uniform and granular with no material greater than minus 3-inch.
LIMITS: The design is based on information submitted. If soil conditions encountered are different from conditions
described in report, CBO Inc. should be notified. All OWTS construction must be according to the county
regulations. Requirements not specified in this report must follow applicable county regulations. The
contractor should have documented and demonstrated knowledge of the requirements and regulations of
the county in which they are working. Licensing of Systems Contractors may be required by county
regulation.
Page 10
Please call with questions.
Sincerely,
CBO Inc.
Carla Ostberg, MPH, REHS
Pump Selection for a Pressurized System - Single Family Residence Project
387 Meadow Lane
Parameters
Discharge Assembly Size
Transport Length Before Valve
Transport Pipe Class
Transport Line Size
Distributing Valve Model
Transport Length After Valve
Transport Pipe Class
Transport Pipe Size
Max Elevation Lift
Manifold Length
Manifold Pipe Class
Manifold Pipe Size
Number of Laterals per Cell
Lateral Length
Lateral Pipe Class
Lateral Pipe Size
Orifice Size
Orifice Spacing
Residual Head
Flow Meter
'Add-on' Friction Losses
1.25
6
40
1.50
6402
61
40
1.50
3
3
40
1.25
4
31
40
1.50
5/32
2.5
5
None
0
inches
feet
inches
feet
inches
feet
feet
inches
feet
inches
inches
feet
feet
inches
feet
Calculations
Minimum Flow Rate per Orifice
Number of Orifices per Zone
Total Flow Rate per Zone
Number of Laterals per Zone
% Flow Differential 1st/Last Orifice
Transport Velocity Before Valve
Transport Velocity After Valve
0.68
26
17.6
2
0.5
2.8
2.8
gpm
gpm
%
fps
fps
Frictional Head Losses
Loss through Discharge
Loss in Transport Before Valve
Loss through Valve
Loss in Transport after Valve
Loss in Manifold
Loss in Laterals
Loss through Flowmeter
'Add-on' Friction Losses
2.2
0.1
3.7
1.2
0.0
0.1
0.0
0.0
feet
feet
feet
feet
feet
feet
feet
feet
Pipe Volumes
Vol of Transport Line Before Valve
Vol of Transport Line After Valve
Vol of Manifold
Vol of Laterals per Zone
Total Vol Before Valve
Total Vol After Valve
0.6
6.5
0.2
6.6
0.6
13.2
gals
gals
gals
gals
gals
gals
17.6
15.3
gpm
feet
0 5 10 15 20 25 30 35 40
0
50
100
150
200
250
300
Net Discharge (gpm)
PumpData
PF3005 High Head Effluent Pump
30 GPM, 1/2HP
115/230V 1Ø 60Hz, 200V 3Ø 60Hz
PF3007 High Head Effluent Pump
30 GPM, 3/4HP
230V 1Ø 60Hz, 200/460V 3Ø 60Hz
PF3010 High Head Effluent Pump
30 GPM, 1HP
230V 1Ø 60Hz, 200/460V 3Ø 60Hz
PF3015 High Head Effluent Pump
30 GPM, 1-1/2HP
230V 1Ø 60Hz, 200/230/460V 3Ø 60Hz
Legend
System Curve:
Pump Curve:
Pump Optimal Range:
Operating Point:
Design Point:
Gareld County, CO
Developed by
Account
Number
R080475
Parcel
Number
218535403028
Acres 1
Land SqFt 0
Tax Area 131
2019 Mill Levy 73.2960
Physical
Address
387 MEADOW LN
GLENWOOD SPRINGS 81601
Owner
Address
BLEAKLEY, DAVID &
DOROTHY
387 MEADOW LN
GLENWOOD SPRINGS CO
81601
2019 Total Actual
Value
$1,093,240 Last 2 Sales
Date Price
7/14/2006 $525,000
3/15/1989 $37,500
Date created: 2/15/2024
Last Data Uploaded: 2/15/2024 2:11:12 AM
230 ft
Overview
Legend
Parcels
Roads
Parcel/Account
Numbers
Owner Name
Lakes & Rivers
County Boundary
Line