HomeMy WebLinkAboutConditions of PermitCONDITIO NS OF PERMIT
BLCO-03 -24-8553
GLENWOOD SPRINGS CITADEL SELF STORAGE
NEW 2 STORY, CLIMATE CONTROLED SELF STORAGE FACILITY
CENTER DRIVE, PARCEL 218506 1 OOO42
COOPER SUBDIVISION, WEST GLENWOOD
THE APPROVED PLANS ARE TO BE ON-SITE FOR INSPECTIONS.
SANITARY FACILITIES ARE REOUIRED TO BE PROVIDED FOR WORKERS.
A LIST OF REOUIRED INSPECTIONS WILL BE ATTACHED TO THE PLANS. THE STATE
IS TO PERMIT AND APPROVE THE ELECTRICAL WORK.
UNDERGROUND UTILIry LOCATES IS THE RESPONSIBILIry OF THE OWNER OR
CONTRACTOR. 811 IS THE COLORADO UTILIry LOCATE HOT LINE.
EVALUATE THE OVER TOPPING OF THE DETENTION PONDS DURING LARGER
MAGNITUDE STORMS. IN THE INTERIM BETWEEN THE PROPOSED GRADE PLAN
AND FINAL BUILDOUT, IT'S TO BE VERIFIED THAT RUNOFF WOULD BE SAFELY
CONVEYED THROUGH THE PROJECT WITHOUT DETRIMENT TO ADJACENT
PROPERTIES.
ALL BACKFLOW PREVENTERS ARE REOUIRED TO BE TESTED AND CERTIFIED BY A
LICENSED BACKFLOW SPECIALIST AFTER INSTALLATION AND PRIOR TO ISSUANCE
OF THE CERTIFICATE OF OCCUPANCY.
SEPARATE SIGN PERMITS ARE REOUIRED FOR ANY EXTERNAL SIGNS. PLEASE SEE
THE COUNry'S WEBSITE FOR THE APPLICATION.
ELECTRICAL CODE COMPLIANCE WILL BE DETERMINED BASED ON FIELD
INSPECTIONS PERFORMED BY THE STATE ELECTRICAL INSPECTOR, (303) 869-3458.
PLEASE HAVE THE INSPECTOR SIGN THE BUILDING CARD OR PROVIDE WRITTEN
DOCUMENTATION OF THE INSPECTIONS.
THE ELECTRICAL CODE REQUIRES A SEPARATE ELECTRICAL PERMIT FOR LOW
VOLTAGE FIRE ALARMS THAT HAS AN ALARM PANEL AND SEND A NOTIFICATION
TO THE FIRE DISTRICT WHEN UNDER ALARM. A ROUGH-IN INSPECTION WITH THE
STATE ELECTRICAL INSPECTOR lS REOUIRED (303)869-3458. Please have the
inspector sign the building card or provide written documentation of the inspection.
THE FIRE SPRINKLER AND ALARM ARE REOUIRED TO BE INSPECTED AND
APPROVED BY THE LOCAL FIRE PROTECTION DISTRICT. PLEASE PROVIDE SHOP
DRAWINGS TO THE FIRE DISTRICT FOR REVIEW AND SCHEDULE THE INSPECTIONS
ACCORDINGLY. PLEASE HAVE THE FIRE MARSHAL SIGN THE INSPECTION CARD
WHEN THE ROUGH INSPECTION IS APPROVED AND WHEN THE FINAL INSPECTION
IS APPROVED.
ANY WATER SUPPLY THAT FEEDS A FIRE SUPPRESSION SYSTEM IS TO BE
INSPECTED BY THE FIRE MARSHAL FOR THAT FIRE DISTRICT PRIOR TO
BACKFILLING.
PLEASE PROVIDE SPECIAL INSPECTIONS REPORTS TO THE BUILDING DEPARTMENT
AS SPECIFIED WITHIN THE GENERAL NOTES OF THE STRUCTURAL DRAWINGS.
GEOTECHNICAL OBSERVATION IS REOUIRED WHEN THE EXCAVATION IS
COMPLETE AND WRITTEN VERIFICATION BE SUPPLIED AT FOOTING INSPECTION.
THE SOILS REPORT IS REOUIRING 18" OF STRUCTURAL FILL UNDER THE FOOTINGS
AND SLAB. IMPORTED STRUCTURAL FILL IS REOUIRED UNDER THE RETAINING
WALL FOOTTNGS (3000pSF). ON-SrrE SOrLS CAN BE USED AS STRUCTURAL FILL ON
THE REMATNDER OF THE FOOTINGS (2000PSF).
COMBUSTIBLE MATERIAL IS LIMITED IN ryPE IAND ryPE II CONSTRUCTION. SEE
IBC 603 FOR ALLOWED COMBUSTIBLE MATERIALS.
ALL EXTERIOR LIGHTING IS TO BE DOWNCAST AND SHIELDED
ANY MEMBRANE AND THROUGH PENETRATIONS OF THE FIRE RESISTIVE
CONSTRUCTION WILL BE REOUIRED TO BE FIRE-STOPPED WITH LISTED FIRE
STOPPING ASSEMBLIES. THE CONTRACTOR IS TO PROVIDE A CUT SHEET FOR THE
ASSEMBLTES AT THE FRAMING INSPECTION. (lBC 713)
A KNOX BOX IS REOUIRED TO BE MOUNTED ADJACENT TO THE FRONT DOOR.
PLEASE CONTACT THE LOCAL FIRE DISTRICT FOR EXACT LOCATION.
IF THE FIRE SPRINKLER SYSTEM REOUIRES A FIRE PUMP. THEN THE UTILITY ROOM
THAT HOUSES THE PUMP WILL BE REOUIRED TO BE ONE-HOUR CONSTRUCTION.
(rBC TABLE 508.2.s)
ALL ACCESSIBLE DOOR HARDWARE SHALL HAVE A SHAPE THAT IS EASY TO GRIP,
tNCLUDTNG POCKET AND SLIDING DOORS. (ANSI A117.1 - 404.2.6)
THE UNIT HEATERS SHOWN IN THE STAIR ENCLOSERS ARE NOT TO PROJECT INTO
THE EGRESS WTDTH. (lBC 1003.3)
AN AIR LEAKAGE TEST IS REOUIRED PRIOR TO PERFORMING THE FINAL BUILDING
r NSPECTTON. (r ECC C402.s)
THE LOUVERS IN THE MECHANICAL ROOM DOORS ARE TO BE LARGE ENOUGH TO
ACCOMMODATE THE RETURN AIR FOR THE FURNACE.
A SPRAY APPLIED THERMAL BARRIER IS BEING PROPOSED TO PROTECT THE SPRAY
FOAM INSULATION IN THE EXTERIOR WALLS. PLEASE PROVIDE THE BUILDING
INSPECTOR WITH THE PRODUCT INFORMATION AND A THIRD-PARTY SPECIAL
INSPECTION FOR THE THERMAL BARRIER.
THE SNOW MELT SYSTEMS FOR THE NORTH ENTRANCES ARE INDICATED AS
DESIGN BUILD. THE AUTOMATIC CONTROLS TO BE VERIFIED DURING
INSPECTIONS.
C.l0l.t2J Snow- rnd icr'melt rlttem cuntruls' -$nntry'
lnd ic:c-mclting lty$lrmii shall includts &llltltnrllic cotrlrultl
configurerl l$ lihrl nlT tle s!"ircm whcn tht psvrlri*nt tfln-
p€rstum is rhove qroF { l0oc} iud grrecipitation is rlot fxll-
ing, and an rutolnalic or nrtnual contrcl that it eonfigurud
to shul off when the anr&xr l€mlteralure is abnvE 4{loF
t4'Cl-